Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid-interactive buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Alfalfa Virtual Building Service: Software Engineering Best Practices Applied to Runtime Interaction with Building Energy Models

Buildings are active participants in increasingly complex energy systems. Building Energy Modeling (BEM) has a key role to play in planning and de-risking an equitable energy transition, with BEM-backed "virtual buildings" critical path for diverse applications that include workforce training tools, Hardware-in-the-Loop (HIL) experimentation to study equipment performance under a range of conditions, Control-Hardware-in-the-Loop (CHIL) experimentation to de-risk commercial control implementations at equipment through grid orchestration levels, and integration of dynamic load profiles into grid modeling tools for energy system experimentation at the urban scale. Modeling requirements vary across these applications, but many software engineering tasks do not. The Alfalfa Virtual Building Service (AVBS, see https://github.com/NREL/alfalfa/wiki) is an open-source web service that solves these common tasks robustly in one place, providing a foundational platform for power users to bootstrap their own applications. AVBS abstracts the specifics of runtime interaction with OpenStudio, Modelica, and Spawn of EnergyPlus models behind a unified REST API. Additionally, AVBS provides resources for cloud deployment and scaling to 100s of parallel simulations, a growing library of modular Operational Technology (OT) integrations for emulation of real-world interfaces, and scripts to automate the population of communities of virtual buildings from URBANopt, ResStock and ComStock.

building automation↗

Practical challenges of model predictive control (MPC) for grid interactive small and medium commercial buildings

To the urgent call for mitigating climate change, substantial initiatives have been undertaken to deploy grid-interactive heating, ventilation, and air-conditioning (HVAC) controls, such as model predictive control (MPC) for buildings. These efforts typically aim to curtail peak energy demand, shift load and enhance overall energy efficiency. With the recent development of low-cost MPC technologies that don’t require extensive instrumentation or manual modeling, small and medium commercial buildings (SMCBs), which rarely utilize advanced HVAC control systems, have become candidates for grid-interactive efficient buildings (GEBs). However, despite the potential benefits and maturity of the technology itself, several practical challenges remain in real-world implementation. In this paper, we share the practical challenges that we have encountered in implementing and testing three types of MPC solutions (ON/OFF unit, dualfuel, and VRF systems) on multiple SMCB sites. We describe the MPC deployment process and discuss the lessons learned. The site selection, eligibility, and retrofit availability (e.g., utility price structure, thermostat communications, etc.) are the main discussion points at the beginning of the project. Also, the modeling automation and the best practices for interacting with endusers and handling erroneous situations are presented for successful operations.

woo Ham, Sang↗

Reducing Grid Costs while Abating Emissions: Opportunities for Flexible Building Loads

This study evaluates the value of technology-agnostic, shiftable flexible building loads in modeled 2030 and 2040 U.S. grids for four types of customers under three potential aggregated distributed energy resources programs. The value examined includes monetary value from providing grid services (e.g., energy, capacity, flexibility reserve, regulation reserve, contingency reserve) and from reducing greenhouse gas emissions. By comparing more than 845,164,800 simulated shifting opportunities, the study finds that the timing of consumption is critical for profit-driven customers. A program that is activated for 30 critical hours of system operation can result in to $73 per year in revenue for 1 kWh of shiftable load. Emission reduction, on the other hand, is best accumulated through a year-round program: 1 kWh of shiftable load can lead to up to 487.9 kg CO2e carbon reduction per year. The report also provides detailed insights on the trade-off between revenue and emissions, regional variation, short- versus medium- term value, and impacts from various building flexibility parameters, such as shifting window and dissipation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CityLearn v2: energy-flexible, resilient, occupant-centric, and carbon-aware management of grid-interactive communities

As more distributed energy resources become part of the demand-side infrastructure, quantifying their energy flexibility on a community scale is crucial. CityLearn v1 provided an environment for benchmarking control algorithms. However, there is no standardized environment utilizing realistic building-stock datasets for distributed energy resource control benchmarking without co-simulation or third-party frameworks. CityLearn v2 extends CityLearn v1 by providing a stand-alone simulation environment that leverages the End-Use Load Profiles for the U.S. Building Stock dataset to create grid-interactive communities for resilient, multi-agent, and objective control of distributed energy resources with dynamic occupant feedback. While the v1 environment used pre-simulated building thermal loads, the v2 environment uses data-driven thermal dynamics and eliminates the need for co-simulation with building energy performance software. This work details the v2 environment and provides application examples that use reinforcement learning control to manage battery energy storage system, vehicle-to-grid control, and thermal comfort during heat pump power modulation.

Nweye, Kingsley↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Energy Storage Integration and Management Platform for Buildings (SESIMP-B)

This project involved the design, development, and testing of a commercial smart service panel. It includes an innovative AI-driven control method to manage smart functions of the panel and a technical-economic feasibility assessment for enhancing building energy resilience and grid-edge technology integration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency and Demand Flexibility in Large Office Buildings

Data is associated with Report "Efficiency and Demand Flexibility in Large Office Buildings" by Joyce McLaren, Thomas Bowen, and Chioke Harris ( https://doi.org/10.2172/1989231 ). Results are created from repos GEB_ECM_Impact_Estimator ( https://github.nlr.gov/tbowen/GEB_ECM_Impact_Estimator ). Results outline the changes in building load in large office buildings based on measures from NREL's Scout, and the impacts those changes in load have on grid-induced emissions, grid operating costs, and customer bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

Rapid deployment of residential photovoltaic (PV) systems helps decarbonize our electricity supplies, but under certain circumstances, high-penetration PV may pose challenges to the electrical distribution grid. In a project funded by the U.S. Department of Energy's Solar Energy Technologies Office and Building Technologies Office, the National Renewable Energy Laboratory and its partners studied how flexible building loads and battery storage, when coordinated at home-level and community-level scales, can be used to address those challenges and enhance grid resilience. In this webinar, we will discuss the methodology, simulation and field pilot results, insights from partners, and lessons learned from the project.

artificial intelligence↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Carl T. Hayden Veterans Affairs Medical Center: Smart Buildings Case Study

The purpose of this smart buildings case study is to showcase a leading example of a GEB renovation project in the federal buildings space and provide key information on the technology and control upgrades, costs, and energy and utility bill savings. This case study also provides information and recommendations for selecting energy conservation measures (ECMs) and choosing energy and cost reduction strategies from the energy management team at the site. The findings from this successful GEB project can be used to help pave the way for additional GEB retrofits in the future. The Carl T. Hayden Veterans Affairs (VA) Medical Center in Phoenix, Arizona, demonstrates that GEB strategies and technologies can be realistically deployed today across buildings with substantial energy and cost savings. The project implemented both ECMs and grid-interactive technologies and controls strategies, making it a leading example of a smart, sustainable, and efficient commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bridging Control and Deployment: A Cross-Layer Analysis of Scalable Building Cluster Control

Building cluster control has emerged as a promising approach for enabling flexible and coordinated operation of distributed building systems, yet its transition from pilot demonstrations to routine grid-interactive operation remains limited. This paper argues that this gap cannot be explained by control algorithms alone. Instead, it arises from interacting barriers in communication infrastructure, data and semantic interoperability, uncertainty management, stakeholder participation, market design, and policy support. Accordingly, the paper reviews both technical and non-technical barriers to building cluster control. Technical challenges include heterogeneous devices and protocols, communication latency and reliability, distributed decision-making, and uncertainty propagation across aggregated loads. Non-technical barriers include user participation, stakeholder coordination, incentive allocation, and data governance. Existing solution approaches are synthesized, including semantic interoperability frameworks, edge and hierarchical communication architectures, distributed and transactive control strategies, uncertainty-aware optimization, policy mechanisms, and market reforms. Based on this analysis, two research directions are identified: testing infrastructures that can evaluate control performance under realistic multi-building conditions, and abstraction methods that allow building clusters to interact with other energy sectors through standardized flexibility representations. Overall, the paper provides a structured review of how building cluster control can move from isolated demonstrations toward reproducible, market-compatible, and grid-relevant implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Hybrid Classification-Regression Solution for High-Frequency Nonintrusive Load Monitoring

Residential buildings with the ability to monitor and control their net-load (sum of load and generation) can provide valuable flexibility to power grid operators. We present a novel multiclass nonintrusive load monitoring (NILM) approach that enables effective net-load monitoring capabilities at high-frequency with minimal additional equipment and cost. The proposed machine learning based solution provides accurate multiclass state predictions while operating at a faster timescale (able to provide a prediction for each 60- Hz ac cycle used in US power grid) without relying on event-detection techniques. We also introduce an innovative hybrid classification-regression method that allows for the prediction of not only load on/off states but also individual load operating power levels. A test bed with eight residential appliances is used for validating the NILM approach. Results show that the overall method has high accuracy, good scaling and generalization properties.

feature extraction↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Automation

In this chapter, we focus on both need-based and vision-based control innovation for building automation for HVAC systems. After providing a brief background that describes different HVAC architectures and products, we describe the control challenges and opportunities from a needs-based point of view, at the equipment level, the systems level, and the building level. At the equipment level, increased use of continuously variable actuation such as variable speed compressors and fans, requires application of robust multivariable control that must consider various types of nonlinear behavior across increasingly larger operating envelopes. The objective at this level is to achieve robust and energy efficient operation. At the system level, coupled and interactive dynamics among subsystems are increasingly important to consider, and functional integration of these subsystems, along with set points and operating schedules are designed to minimize energy consumption and improve occupant comfort. At the building level, issues such as integration among other building systems, such as the building envelope and the electric grid, offer opportunities to develop new types of demand response and grid-interactive behaviors and technologies. At the higher levels, system dynamics and robust stability are less of an issue, similar to process control applications, while optimization and integration are more important, although dynamic stability is increasing an issue at the higher levels too. From a vision-driven innovation point of view, we describe three areas that will require sustained research efforts and will eventually impact building automation: Digital Twins, Model Predictive Control, and Grid Interactive Buildings.

Bortoff, Scott↗

The first field application of a low-cost MPC for grid-interactive K-12 schools: Lessons-learned and savings assessment

K-12 schools are the largest energy consumers in the public sector, with their HVAC energy consumption representing the largest portion of their total energy use. While transitioning these schools to grid-interactive HVAC system operation through advanced controls offers significant financial and environmental benefits, and model predictive control (MPC) has been identified as a promising solution to achieve that, very few MPCs are affordable and have been deployed in K-12 schools. This situation raises concerns about the unclear real-world benefits of MPC technology among facility managers and industries. To address this gap, this paper presents a low-cost MPC solution that requires minimal control infrastructure costs and a unique field demonstration at a K-12 school, conducted for both cooling and heating seasons. This work adopted a previously developed MPC and extended it for use in the school application. The MPC aims to coordinate multiple packaged units to eliminate unnecessary peaks and shift cooling or heating loads in response to grid signals based on load conditions, while maintaining thermostat temperatures within school-defined bounds. Throughout the field tests, the MPC achieved a 24% reduction in peak demand during the cooling season and shifted cooling or heating loads by up to 16% in response to the school's utility tariff, considering load conditions, while also allowing end-users to override thermostat setpoints. Further, the paper also discusses the limitations of this study and future research directions for better performance of the MPC at K-12 schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗