Droughts in Wind and Solar Power: Assessing Climate Model Simulations for a Net‐Zero Energy Future

Abstract Understanding and predicting “droughts” in wind and solar power availability can help the electric grid operator planning and operation toward deep renewable penetration. We assess climate models' ability to simulate these droughts at different horizontal resolutions, ∼100 and ∼25 km, over Western North America and Texas. We find that these power droughts are associated with the high/low pressure systems. The simulated wind and solar power variabilities and their corresponding droughts during historical periods are more sensitive to the model bias than to the model resolution. Future climate simulations reveal varied future change of these droughts across different regions. Although model resolution does not affect the simulation of historical droughts, it does impact the simulated future changes. This suggests that regional response to future warming can vary considerably in high‐ and low‐resolution models. These insights have important implications for adapting power system planning and operations to the changing climate.

Liu, Xue [Department of Oceanography Texas A&amp,M

More land is needed for solar and wind infrastructure under a high renewables scenario in the Western US by 2050

Expanding United States electricity infrastructure to meet growing demand could require extensive power plant development footprints and land use conversion, depending on the mix of generation types chosen. Understanding where future power plant sitings are likely to take place and identifying potential conflicts and land-use tradeoffs will be key to identifying feasible and affordable investments and evaluating regional planning coordination needs. Here we use an integrated modeling framework that combines capacity expansion planning, hourly grid operations, and geospatial techno-economic analysis to develop projections (2025-2050) of power plant sitings in the Western United States (US) at a 1 km 2 resolution for a business-as-usual scenario and a high renewables penetration scenario. We find that 30% more land will be needed in the high renewables scenario as compared to business-as-usual, and that 75% of that development is projected to be located within 10 km of natural areas.

Mongird, Kendall [Pacific Northwest National Labor

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION

Optimal Control of Differentially Private EV Charging: A Scalable Learning Approach Under Uncertainty

Internet of Things (IoT)-enabled electric vehicles (IoEVs) enable intelligent charging coordination that accounts for grid congestion. However, increased data exchange raises privacy concerns, as charging patterns can reveal sensitive driver behavior to grid operators. Here, we propose a differentially private (DP) EV charging framework that enables coordinated control while protecting driver data with theoretical privacy guarantees. Nevertheless, integrating DP inevitably introduces uncertainty into the control strategy for EVs, which can lead to infeasible solutions. To tackle this challenge, we develop a feasible and scalable control algorithm based on constrained reinforcement learning (CRL) and convex hulls. While our framework is designed to handle the uncertainty introduced by DP, it is general and also applicable to other sources of uncertainty in EV charging, such as the stochastic nature of driver behavior and renewable variability. This ensures feasible and privacy-preserving coordination of EV charging at scale. Our method constructs convex hulls within the action space to guarantee feasibility under stochastic constraints and incorporates constraint reduction techniques to improve scalability. Case studies based on IEEE benchmark systems demonstrate that the proposed approach effectively balances feasibility under uncertainty, scalability, and privacy in large-scale EV charging control.

Engineering - Power transmission and distribution

Regional Inertia Estimation Using Actual Event Measurements: Florida Case

As inverter-based resources’ integration in power grids increases, their uneven distribution across the electrical network leads to the formation of local regions that are weakly coupled to the larger interconnection. This signifies the necessity of regional frequency dynamics investigation and analyzing various inertia metrics. This paper presents a practical methodology for estimating regional rate-of-change of frequency (RoCoF) using actual event recordings, which is then used to evaluate regional inertia. Florida (FL) is selected as the region of interest due to its distinct regional frequency dynamics and the rising levels of solar generation. We identify and analyze confirmed events from 2017 to 2024 that occurred in FL. The results indicate that FL contributes about 14% to the total inertia of the US Eastern Interconnection, which approximately matches its share of generation capacity. Results also highlight seasonal fluctuations in energy generation, which play a significant role in influencing inertia and thus the RoCoF levels. This emphasizes the importance of estimating regional inertia to enhance grid operations for a future that focuses on distributed generation.

Dulal, Saurav [University of Tennessee, Knoxville

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE

Electromagnetic Transient Simulation of Large-Scale Inverter-Based Resources With High-Granularity

The power grid is undergoing a significant transformation with the rapid increase in inverter-based resources (IBRs), including large-scale photovoltaic (PV) plants. Ensuring reliable and resilient grid operation in this new paradigm necessitates high-granularity electromagnetic transient (EMT) modeling that accurately captures the behavior of individual inverters and their interactions within IBR plants. Central to this approach is the detailed representation of both the IBR plant’s collector system and the dynamics of individual inverters. To achieve this, a high-granularity EMT model of a large-scale PV plant has been developed using advanced simulation algorithms, including matrix splitting and the Schur complement. These proposed techniques significantly enhance simulation speed, numerical stability, and accuracy while improving the modularity and efficiency of the collector system’s representation. The effectiveness of the proposed methods is validated through simulations of a representative large-scale PV plant consisting of 125 individual PV inverters, 25 IBR unit transformers, and a 52-bus collector system.

Choi, Jongchan [Oak Ridge National Laboratory (ORN

Enhancing Solar Power Forecasting with Regularized Constrained Quantile Regression Averaging and Bootstrapping Techniques

Probabilistic solar power forecasting (SPF) plays an essential role in optimizing power-grid operations by quantifying the forecast uncertainty. To improve the accuracy and robustness of probabilistic SPF, this paper introduces the regularized constrained quantile regression averaging (rCQRA) method to combine outputs from multiple PSPF models. In addition, a bootstrapping method was used to quantify model uncertainty, providing insights into the reliability and significance of each ensemble component. To evaluate its efficacy, the proposed rCQRA method is used to integrate four PSPF methods. The resulting SPF models are trained and validated using a real-world six-year dataset from a rooftop solar plant in the USA. The performance of the proposed rCQRA method is evaluated and compared with two benchmark methods under three categories of weather conditions. It is shown that the rCQRA method has superior performance in its forecast reliability, sharpness, and accuracy.

Ensemble learning, probabilistic solar power forec

Optimizing Grid-interactive Efficient Building Designs with Stacked Value Streams

Grid-interactive efficient buildings (GEBs) are those characterized by the combination of energy efficiency and demand flexibility with smart technologies and communications to not only deliver greater affordability and comfort to buildings, but also help utilities manage grid operations and lower system costs. This paper presents an innovative techno-economic assessment framework to effectively examine different GEB design options, explore various use cases, define technically achievable benefits, and thereby assist in informed decision-making. In particular, building load flexibility, thermal storage, and battery energy storage are considered. Advanced optimal dispatch problem is formulated to maximize the stacked value streams from multiple, competing use cases, subject to the physical capabilities and operational flexibility associated with different designs and configurations. Comprehensive case studies were performed for a real-world building to evaluate the cost-effectiveness of different GEB designs and offer in-depth insights. It was found that the proposed assessment method could effectively capture the costs and benefits linked to each GEB design option. Furthermore, the study revealed that outage mitigation and demand response are the two most significant sources of benefits for GEBs.

Ma, Xu

OpenSAMPL: An Open Source Library for Timing and Synchronization Measurements and Analytics

Today's power grid operators are implementing timing and synchronization solutions that provide resilience to Global Navigation Satellite System (GNSS) vulnerabilities. These vendor-specific solutions often come with additional software applications that are designed to monitor that vendor's synchronization performance data. However, resilient timing architectures often resulting in multi-vendor solutions, including approaches that blend terrestrial clocks with space-based subscription services. In such an environment, collecting, analyzing, and visualizing data from a variety of sources within a single platform was heretofore not possible. To address this need, the US Department of Energy's Center for Alternative Synchronization and Timing (CAST) developed OpenSAMPL, the Open Synchronized Analytics and Monitoring Platform, an open-source Python framework for processing, loading, and observing clock measurement data from distributed devices. OpenSAMPL enables the ingestion of diverse clock-probe sources into a scalable time-series database and applies robust analytics. OpenSAMPL currently supports two vendor data pipelines, and will be extended to more in the near future, enabling seamless monitoring of a variety of timing and synchronization devices in a common environment.

Grant, Josh [ORNL] (ORCID:0000000163475060)

Probability Density Function Control of Frequency Fluctuations in Renewable-Rich Power Systems

The stochastic nature of renewable energy sources (RESs) necessitates treating power system frequency response as a random process with a nonstationary probability density function (PDF). Here, based upon the stochastic distribution control theory originated by the second author, this paper proposes a novel stochastic controller to improve the frequency PDF in power grids when integrating a large amount of RESs, thereby minimizing the effects of uncertainties and enhancing overall system stability. The key idea is to manipulate the controllable power generation resources so that the frequency PDF is make to follow a target PDF by using the stochastic distribution control theory originated by the second author. The proposed method can easily be plugged into existing automatic generation controls for multi-area transmission grids. The proposed method is validated via a modified Kundar's two area system and 240-bus Western Electricity Coordinating Council systems. The simulation results show that the proposed control shapes the frequency PDF narrower and sharper, leading to a notable improvement toward minimizing the effects of randomness and uncertainty during grid operation.

frequency

Parallel-in-Time Solution of Scalar Nonlinear Conservation Laws

Here, we consider the parallel-in-time solution of scalar nonlinear conservation laws in one spatial dimension. The equations are discretized in space with a conservative finite-volume method using weighted essentially nonoscillatory (WENO) reconstructions, and in time with high-order explicit Runge–Kutta methods. The solution of the global, discretized space-time problem is sought via a nonlinear iteration that uses a novel linearization strategy in cases of nondifferentiable equations. Under certain choices of discretization and algorithmic parameters, the nonlinear iteration coincides with Newton’s method, although, more generally, it is a preconditioned residual correction scheme. At each nonlinear iteration, the linearized problem takes the form of a certain discretization of a linear conservation law over the space-time domain in question. An approximate parallel-in-time solution of the linearized problem is computed with a single multigrid reduction-in-time (MGRIT) iteration; however, any other effective parallel-in-time method could be used in its place. The MGRIT iteration employs a novel coarse-grid operator that is a modified conservative semi-Lagrangian discretization and generalizes those we have developed previously for nonconservative scalar linear hyperbolic problems. Numerical tests are performed for the inviscid Burgers and Buckley–Leverett equations. For many test problems, the solver converges in just a handful of iterations with a convergence rate independent of mesh resolution, including problems with (interacting) shocks and rarefactions.

97 MATHEMATICS AND COMPUTING

Assessment of Electric Grid Transmission System Simulator for Human Factors Research

Over the past decades, various technologies have been developed for electric grid operations to support clean energy, meet rising electricity demands, and address infrastructure concerns. However, the human factors aspect is often overlooked during rapid integration. Questions persist about how these technologies impact human performance. Simulators play a critical role in supporting investigation of human factors design concepts and conducting comprehensive usability testing to evaluate human performance and assess human reliability. This paper aims to address human factors research simulator requirements and conduct a comparative study of six different simulators. A detailed evaluation reveals that the evaluated simulators lack the ability to customize user interfaces. Additionally, their user interface designs do not fulfill the basic human factors design principles, potentially leading to increased response variability and reduced statistical power when conducting controlled experimental research. In the future, it is essential to develop scripting tools to integrate customizable user interfaces and simulation models, ensuring meeting research requirements.

Li, Ruixuan

Non-Intrusive Parallel-in-Time Solvers for Partial Differential Equations (Final Report)

Many time-dependent problems and simulations are often modeled using Partial Differential Equations. Traditional modeling approaches that use sequential time-stepping are reaching a bottleneck in optimizing efficiency. The Center of Applied Science and Computing at Lawrence Livermore National Laboratory extensively works on parallelizing these algorithms to leverage the increasing computational power from the growing number of processors in computer hardware. In particular, they aim to design non-intrusive algorithms that can generalize to a variety of problems and sizes without requiring additional information from or modifications on the original problems. Multigrid Reduction in Time (MGRIT) is a parallel-in-time algorithm that is designed to be non-intrusive. This project focuses on increasing the efficiency of MGRIT by approximating the coarse-grid operator using machine learning approaches as a means to find the most non-intrusive, or general, solution.

97 MATHEMATICS AND COMPUTING

LLGoMAX : Enhancing Industry-Standard Tools for AC Optimal Unit Commitment

In 2018, the Advanced Research Project Agency – Energy (ARPA-E) launched the Grid Optimization Competition (GOC) [1], a series of competitive challenges intended to accelerate innovation in decision support software used to schedule power grid operations, making them as efficient as possible, while respecting operational constraints of power equipment and operational security. This report covers the participation of the LLGoMAX team—a collaboration of the Lawrence Livermore National Laboratory (LLNL) and ECCO International, Inc.—in Challenge 3 of the competition.

97 MATHEMATICS AND COMPUTING

Defining a Platform Approach and Market Participation: Data Driven Business Models for Solid State Transformer-Based Synthetic Inertia and Voltage Stability Controls (CRADA Final Report, Project 1, Mod 1)

The primary objective of this project is to determine the incremental value created with the medium voltage solid-state transformer (MV SST) technology to different stakeholders in view of the updated DER grid regulations. This includes studying the benefits of the MV SST technology in a range of use cases for EV and DER penetration including (1) “corridor charging” for EVs and (2) solar plus storage (FERC 2222). The potential customers of this technology include utilities for EV charging, DER installers who must meet utility interconnection requirements, balancing authorities, and DER aggregators. The traditional transformers on the grid could be a limiting factor for the EV-grid integration as the distribution transformers were not designed to handle the dynamic and fluctuating EV charging loads. Thus, the issues such as voltage fluctuations, increased losses and reduced efficiency [1] can negatively impact the grid operation. To address these challenges, transformers with flexibility and adaptability become imperative to meet the evolving energy demands. In this regard, the concept of Medium Voltage Solid-State Transformers.

14 SOLAR ENERGY

Recovery Simulator and Analysis Formulation: Mathematical Framework for Enhanced Resilience and Resource Allocation

This report introduces recovery simulator and analysis (RSA), a framework aimed at enhancing the resilience of electrical grids post-disruption. The RSA model leverages an optimization problem formulation that focuses on maximizing the load served (or optionally customers served) through a coordinated and cooptimized recovery of non-black start generation, transmission lines, feeders and substations subject to labor budget constraints. By integrating advanced linear programming techniques, the simulator selects efficient reocovery pathways, optimizing both short-term and long-term grid recovery strategies. The mathematical framework guides decision-making through a comprehensive evaluation of potential recovery actions, factoring in the trade-offs between labor constraints and load (or optionally customer) restoration efficacy. This enables grid operators to simulate diverse outage scenarios and delineate optimal recovery pathways, thereby prioritizing critical repair tasks and ensuring resource allocation is both economical and effective. The intended use case of RSA is to allow planners to explore many recovery scenarios quickly and determine assets most critical across a wide range of scenarios, and therefore strong candidates for hardening or additional investment. RSA might also be used in an operational setting, following a single event, for exploring efficient recovery pathways.

24 POWER TRANSMISSION AND DISTRIBUTION

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION