Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

[Space Weather Impact on the Electricity Market]

Forbes & St. Cyr (2004, hereafter "FISC") have provided evidence that the electricity market can be impacted by space weather. Our analysis indicated that the estimated market impact for PJM was 3.7 % or approximately $500 million dollars over the 19 month sample period. Kappenman has taken exception to this estimate and contends that we have exaggerated the magnitude of the problem that space weather poses to PJM. There are four specific issues: (1) he claims that we have ignored relevant literature; (2) he asserts that Dst is not an appropriate proxy for GICs in PJM; (3) he charges that our findings are inconsistent with the impact of the 17 September 2000 storm; and (4) he alleges that our discussion of October 2003 storms is misleading. In our article, we have explained our methodology, multivariate regression analysis, with a particular focus on how it compares to correlation analysis. We have also explained the limitations of our analysis. We noted that "...While the Dstlprice relationship was found to be robust, the precise estimate should be treated with a relatively high degree of caution given that econometric modeling is not an exact science as well as the fact that the measure of space weather may be a poor proxy for GICs" (paragraph 96). We have also noted that additional research using local magnetometer data are needed (paragraph 97). We did not claim that that our findings for PJM are representative of the impact of space weather on other power grids. On the contrary, we noted that ... "Only analysis of other power grids will tell. " (paragraph 97). Kappenman inaccurately asserts that we have indicated that our findings . . . "imply much higher total costs are likely across the US and elsewhere in the world." He also inaccurately asserts that we have claimed that " . . . Dst is the most suited proxy for GIC in the PJM grid.. ." Moreover, he inaccurately refers to our analysis as a correlation study that uses Dst as quasi-binary indicator.

SaintCyr, O. Chris↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Requirements for Application of Risk-Based Dynamic Contingency Analysis to Evaluate Hurricane Impact to Electrical Infrastructure in Puerto Rico

This paper presents a risk-based dynamic contingency analysis framework that was used to evaluate the hurricane impact to electrical infrastructure in Puerto Rico. PNNL developed a scalable risk-based framework for identifying high-voltage transmission resilience improvements by classifying and prioritizing high-risk power grid contingencies (system failures) under hurricane impact. The risk-based framework is founded on grid outage definitions with their associated probabilities of occurrence from hurricane events, in combination with an impact assessment derived from detailed dynamic cascading failure analysis. This paper focuses on a discussion around data requirements for transmission resilience planning for hurricane events, derived from the development of the risk-based framework and its application to Puerto Rico. This paper launches an important first step in encouraging the engineering community and power system industry to move towards establishing resilience planning as a routine practice. Since actual results for Puerto Rico contain sensitive information, sample simulation results will be used to illustrate the data requirements and risk-based dynamic cascading framework on the Puerto Rico power grid, as well as demonstrate the potential for such a simulation framework. The paper includes a discussion on the lessons learned, importance and need for improved datasets that are not usually considered in traditional power system planning. The paper will also elaborate on how the scalable simulation framework and datasets might be expanded to larger footprints and leveraged for modelling other types of natural disasters.

DCAT, Puerto Rico, hurricane, Power System Stabili↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

Generating Sequential PV Deployment Scenarios for High Renewable Distribution Grid Planning

This paper introduces a novel approach for generating solar photovoltaic (PV) plant deployment scenarios for grid integration planning. The approach guarantees consistency among scenarios of the same deployment by ensuring that higher penetration scenarios contain PV units deployed in lower penetration scenarios. It also constrains the size and spatial distribution of the PV plants and considers three placement types. A case study on a real-world distribution system proves that the precepts of scenario consistency, deployment diversity, and placement are met. The study further investigates the impact of the resulting scenarios via a stochastic hosting capacity analysis. Results indicate that the ratio between PV and load sizes, referred to as the nodal PV penetration factor (NPPF), is a key driver of the grid integration impact. By reducing the NPPF from 5 to 2, the maximum hosting capacity increased by at least 112%. The study also reveals that scenarios under random placement can lead to higher hosting capacity values.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Generating Sequential PV Deployment Scenarios for High Renewable Distribution Grid Planning: Preprint

This paper introduces a novel approach for generating solar photovoltaic (PV) plant deployment scenarios for grid integration planning. The approach guarantees consistency among scenarios of the same deployment by ensuring that higher penetration scenarios contain PV units deployed in lower penetration scenarios. It also constrains the size and spatial distribution of the PV plants and considers three placement types. A case study on a real-world distribution system proves that the precepts of scenario consistency, deployment diversity, and placement are met. The study further investigates the impact of the resulting scenarios via a stochastic hosting capacity analysis. Results indicate that the ratio between PV and load sizes, referred to as the nodal PV penetration factor (NPPF), is a key driver of the grid integration impact. By reducing the NPPF from 5 to 2, the maximum hosting capacity increased by at least 112%. The study also reveals that scenarios under random placement can lead to higher hosting capacity values.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Analyzing Residential Charging Demand for Light-Duty Electric Vehicles in Colorado: Preprint

The past decade has witnessed the rapid adoption of electric vehicles (EVs). The momentum is expected to continue with strong support from the government and industry. Rapid EV adoption brings significant charging demand to the power grid, causing additional stress and non-negligible risks to the already-aging power grid. To help power grid operators understand the impacts of EV home charging on the grid and identify risk factors, this study presents a data-driven residential charging demand analysis for light-duty vehicles. This study considers two real-world grid service regions in Colorado and merges multiple data sources and state-of-the-art tools that characterize EV adoption projections, vehicle travel patterns, seasonal variations, residential charging accessibility, ambient temperature impact, EV charging behaviors, grid utility customers, vehicle registration, and household-level EV charging demand distribution. We characterize potential residential charging demand in 2030 for two regions within the state of Colorado: Boulder and Aurora. We project that EVs will be 26% of the light-duty vehicle population in Boulder and 16% in Aurora. Charging demand is characterized for ten power grid feeders (five for each study region). Across the ten feeders, peak total EV charging powers during wintertime range from less than 1 MW to more than 4 MW.

ADVANCED PROPULSION SYSTEMS↗

EVs@Scale High Power Charging Pillar

Slide deck assesses a portfolio of EVs, EVSEs, and Fleets that are expected to utilize High Power Charging (>200kW) to understand charging rates, grid impacts, and asset utilization. Provide DOE, project partners, stakeholders, and the public with analysis on the capability of HPC performance of today's charging infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

The Lithuania 100% Renewable Energy Study - Interim Results: Electricity System Scenarios for 2030 [Slides]

Lithuania's Energy Vision aims to achieve self-sufficiency in electricity generation by 2035 and transition to 100% renewable energy as soon as possible while maintaining affordability, reliability, and energy security. The Lithuania Energy Agency (LEA) is partnering with the National Renewable Energy Laboratory (NREL) to conduct the Lithuania 100% Renewable Energy Study (Lithuania 100) to provide evidence-based analysis for development of Lithuania's National Energy Independence Strategy. The Lithuania 100 Study leverages unique tools and capabilities of NREL to provide rigorous technical analysis of clean energy policies to achieve 100% renewable energy, and assess impacts on electricity grid operations, hydrogen system development, electricity distribution networks, air quality, and human health outcomes. The study is supported by a stakeholder committee chaired by the Ministry of Energy of Lithuania and implemented by four technical working groups. This report provides highlights of key interim results from modeling of Lithuania's near-term electricity grid through the year 2030. Results show that Lithuania has sufficient renewable energy potential, flexible generation capacity, and interconnection with neighboring European Union countries to reliably meet projected 2030 electricity demand with 100% renewable energy. A range of scenarios were modeled, each of which achieves at least 100% renewable energy in electricity, on average over the year, by 2030. Potential demands for hydrogen across industrial and transportation sectors were also evaluated, as well as the cost of hydrogen produced in Lithuania by 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Grid Utility Asset Vulnerability Assessment (GUAVA) Software Tool

Increasing demand and changes in generation portfolios is pushing power grid to operate towards the limit. However, due to lack of analytical tools for understanding various scales of impact on grid, it is becoming more vulnerable to wide scale power outages and blackouts. A vulnerable grid operating at its limit can be easily disrupted by asset failures caused by devastating hurricanes which has been known to damage transmission and distribution lines along its track. In this direction, researchers have focused on determining these assets by conducting Monte Carlo simulations of hurricanes with uncertainties and collected a large set of simulation data. To determine the infrastructure updates necessary for mitigating wide scale impact of hurricanes on the grid, we propose a software tool named “Grid Utility Asset Vulnerability Analysis” (GUAVA) framework. GUAVA presents a novel data-driven probabilistic analytical approach to (1) post-process hurricane failure scenarios, (2) identify/rank assets that are most vulnerable and critical to failing and are associated with highest impact/risk, and (3) to inform system upgrade decisions & prioritization. Based on the observed results and employed data-driven methodology, it is expected GUAVA can be adapted to provide power system planners with a recommendation engine for making informed decisions to improve resilience of grid.

Mahapatra, Kaveri↗

elci-scenario-modeler

A GitHub repository hosting the Python package, grid_mixer, designated for creating the link between the electricity baseline and scenarios for impact analysis.

Electric Generation and Transmission↗

Describing Function Analysis of Transformer Magnetizing Inductance for Direct Power Control of Back-to-Back Modular Multilevel Converters with Advanced Grid Support

This paper provides a detailed investigation into the application of describing function-based analysis for assessing transformer magnetizing inductance and its impact on system performance. The focus is on a back-to-back modular multilevel converter architecture, designed to interconnect systems operating at different frequencies. The study explores the implementation of a Direct Power Control strategy, examining its effects on transformer magnetizing inductance saturation and offering effective mitigation techniques. Furthermore, the integration of advanced grid support functionalities is highlighted, demonstrating how these enhancements bolster the converter's ability to improve grid stability and power quality, positioning it as a robust solution for modern power systems. The proposed approach is validated through extensive computer simulations based MAT LAB/Simulink domain, supported by significant case study results, confirming its practical effectiveness.

back-to-back modular multilevel converters (B2B- M↗

Distributed Photovoltaic Economic Impact Analysis in Indonesia

Like other countries in the region, the Government of Indonesia aims to increase its use renewable energy in the near term from various technologies, including grid-connected distributed photovoltaics (DPV). While little DPV has been installed to date, the policy landscape has been shifting over the past few years with recent pronouncements from the state-run utility Perusahaan Listrik Negara (PLN) and the Ministry of Energy and Mines (MEMR) that have begun to provide a more supportive policy framework for the deployment of DPV. Nonetheless, many questions remain as to how DPV impacts customers, the utility, and the economy as a whole. This report presents a holistic view of DPV economic impacts in the Java-Bali region of Indonesia by assessing customer economic impacts, utility revenue impacts, and jobs and economic development impacts.

14 SOLAR ENERGY↗

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

Towards Improved Decision Making for the Smarter Grid: Geomagnetic Disturbance Implicit Modeling Uncertainty Quantification

Geomagnetic disturbances can greatly disrupt the power grid operation. This is caused by low-frequency changes in the earth’s magnetic field, which upon interaction with the deep earth conductivity induces a changing electric field at the earth’s surface. This in turn induces quasi-direct currents which have the potential to cause protective devices to operate, widespread damage to high-voltage transformers, or voltage collapse due to induced reactive power losses. While these impacts have been known since the 1940s, only recently have standards for GMD response been implemented. Because these standards are heavily based on models, it is important to understand when it is appropriate to make certain modeling assumptions. In this work, implicit modeling uncertainty is quantified for the purpose of enhanced decision making for disturbance impact mitigation. Considering electromagnetic models, modeling assumptions of non-uniform grounding, imbalanced operation, transformer saturation, and geomagnetically induced currents, voltage estimation values are analyzed. Statistical characteristics of modeling uncertainty are obtained by analysis of synthetically generated data. Results statistically characterize geomagnetic disturbances modeling uncertainty, providing an important tool for impact mitigation.

grid analysis↗

Potential Impact of Flexible CHP on the Future Electric Grid in California

This presentation summarizes results from the “Modeling the Impact of Flexible CHP on the Future Electric Grid In California” report (doi:10.2172/1649545). The analysis estimated the value of flexible CHP to the gird in a somewhat decarbonized grid in California. The analysis found that advanced, flexible CHP can more than double capacity with a 6 year payback period, save site owners up to $760 million, reduce CA-ISOs operating cost by over $700 million, and eliminate hours of grid stress in CA-ISO.

CHP↗

Simulating Impacts of Extreme Events on Grids with High Penetrations of Wind Power Resources

As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems, e.g., emergency asset management. Included is an example case study: Hurricane Dolly damaging a synthetic 2000-bus test system during its landing in Southern Texas. We perform statistical analysis of damages and discuss topological effects on the example synthetic grid. Also, we include a cursory evaluation of impacts using simplified operational models. Finally, we discuss how our method can be extended to use even higher-fidelity meteorological data sets and suggest directions for future work.

contingencies↗

Distributed Solar in Tamil Nadu

With India’s ambitious renewable energy targets and decreasing rooftop solar prices, customer adoption of rooftop solar on Tamil Nadu’s distribution network is set to increase in the coming years. With that comes the challenge of how to assess the impact of these emerging distributed energy resources. In an effort to help with such an assessment, NREL has created a holistic analysis framework for Tamil Nadu Generation and Distribution Company (TANGEDCO). The Emerging technologies Management and Risk evaluation on distribution Grids Evolution (EMeRGE) analysis framework and tool will help TANGEDCO and other distribution companies (DISCOMs) in India analyze new interconnection applications and evaluate the system risk impact over time with new emerging DERs.

Children's Investment Fund Foundation↗