Coulomb scatter of diamagnetic dust particles in a cusp magnetic trap under microgravity conditions

The effect of a dc electric field on strongly nonideal Coulomb systems consisting of a large number (~10{sup 4}) of charged diamagnetic dust particles in a cusp magnetic trap are carried out aboard the Russian segment of the International Space Station (ISS) within the Coulomb Crystal experiment. Graphite particles of 100–400 μm in size are used in the experiments. Coulomb scatter of a dust cluster and the formation of threadlike chains of dust particles are observed experimentally. The processes observed are simulated by the molecular dynamics (MD) method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the possibility of placing a universal neutron diffractometer in an inclined channel of the PIK reactor

The possibility of placing a universal neutron diffractometer, which is designed for working with perfect crystals, in one of the inclined channels of the PIK reactor is discussed. It is proposed to use a double monochromator block (DMB) in the vertical plane and mounting crystals in the antiparallel position with reflection at a Bragg angle of 15 Degree-Sign . In this configuration, a set of well-known monochromator crystals (pyrolytic graphite, SiO{sub 2}, Si, Ge, Cu, and Pb) provides transmission bands of quasi-monochromatic neutrons in the range of 1-1.8 Angstrom-Sign . The angular and energy distributions of neutrons transmitted through the DMB are calculated. A scheme of the block for filtering radiations is proposed, and its parameters are calculated. The principles of instrument operation in a physical room (beyond the DMB) are determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct reuse of graphite and lithium nickel manganese cobalt oxide (NMC) recovered from ultrafast-laser ablation debris in Li-ion battery electrodes

Here we demonstrate that debris collected from the ultrafast-laser ablation of graphite anodes can be directly reused in a lithium-ion battery with little to no negative effects on electrochemical performance. Further, we show that while post-ablation NMC (LiNi 0.33 Mn 0.33 Co 0.33 O) cathode debris will require additional processing before being incorporated into an electrode, its critical materials (nickel, manganese, and cobalt) are not lost during ablation and can be recovered for recycling. Pre- and post-ablation materials are characterized with a suite of diagnostics, including SEM, TEM, X-ray CT, EDS, and XRD, to study changes in material morphology, composition and crystal structure. Graphite exhibited little to no morphological or compositional changes and a slight annealing of its crystal structure. NMC underwent profound morphological and crystallographic changes, but retained its elemental composition. Finally, post-ablation materials were re-manufactured into electrodes and cycled vs lithium metal. Graphite showed equal or better capacity and Coulombic efficiency compared to pre-ablation electrodes, while the post-ablation NMC exhibited severely reduced electrochemical performance. Furthermore, we discuss the outlook for application of this work to advanced manufacturing lines that produce next-generation, laser-patterned electrodes.

25 ENERGY STORAGE↗

Synthesis and characterization of nanocrystalline graphite from coconut shell with heating process

Graphite were synthesized and characterized by heating process of coconut shell with varying temperature (400, 800 and 1000°C) and holding time (3 and 5 hours). After heating process, the samples were characterized by X-ray diffraction (XRD) and analyzed by X'pert HighScore Plus Software, Scanning Electron Microcope-Energy Dispersive X-Ray (SEM-EDX) and Transmission Electron Microscope-Energy Dispersive X-Ray (TEM-EDX). Graphite and londsdaelite phase were analyzed by XRD. According to EDX analysis, the sample was heated in 1000°C got the highest content of carbon. The amorphous carbon and nanocrystalline graphite were observed by SEM-EDX and TEM-EDX.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility

We are developing x-ray Thomson scattering for applications in implosion experiments at the National Ignition Facility. In particular we have designed and fielded MACS, a high-efficiency, gated x-ray spectrometer at 7.5–10 keV [T. Döppner et al., Rev. Sci. Instrum. 85, 11D617 (2014)]. Here we report on two new Bragg crystals based on Highly Oriented Pyrolytic Graphite (HOPG), a flat crystal and a dual-section cylindrically curved crystal. We have performed in situ calibration measurements using a brass foil target, and we used the flat HOPG crystal to measure Mo K-shell emission at 18 keV in 2nd order diffraction. Such high photon energy line emission will be required to penetrate and probe ultra-high-density plasmas or plasmas of mid-Z elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coordinated Microstructural and Isotopic Characterization of Diamond Inclusions within the Kenna Ureilite

Introduction: The origin of diamonds in ureilitic meteorites, a major family of ultramafic achondrites, has long been debated, with various formation mechanisms inferred, including: 1) shock conversion of preexisting graphite due to a hypervelocity impact on the ureilite parent body [e.g., 1]; 2) vapor deposition during condensation of the solar nebula [e.g., 2]; or 3) static transformation in the mantle of a large planetesimal (>1000 km in diameter) [e.g., 3]. The Kenna ureilite is a 10.9 kg stone that was found in Kansas in 1972 and is dominantly composed of olivine and pigeonite (68% and 22% modal abundance, respectively), together with minor metal and carbon-rich regions. Within the carbon-rich domains researchers have identified microdiamonds up to ~10 µm in size [4]. Methods: Due to the proximity of the extremely hard microdiamonds with soft graphite and moderately hard silicates, achieving an appropriately flat surface for electron backscatter diffraction (EBSD) analysis has proven challenging. We have, therefore, employed a Hitachi ArBlade 5000 broad beam Ar ion milling system to prepare a sample with an adequately uniform surface flatness across the various minerals. The ion milling dramatically im-proved indexing of the EBSD patterns and facilitated high-resolution microstructural analysis of the carbon-rich domains. After microstructural EBSD analyses using an Oxford Symmetry detector we collected coordinated hy-perspectral cathodoluminescence (CL) analyses using a Gatan Monarc system mounted on a JEOL 7900F field emission (FE) scanning electron microscope at NASA Johnson Space Center. A focused ion beam (FIB) foil was extracted from a region of interest and analyzed using a JEOL 2500 FE scanning transmission electron microscope (STEM). In situ carbon and nitrogen isotopic analyses were collected from diamond-bearing domains using a Cameca NanoSIMS 50L at NASA JSC. Results: The carbon rich regions occur as tabular domains between polygonal olivine and pigeonite, and are composed of aggregates of micrometer-scale diamond with intermediate graphite, oxides and metal grains. Within the microdiamonds, {111} twins are abundant, many of which form ragged lamellae consistent with mechanical twinning. The microdiamond assemblages appear to pseudomorph tabular graphite habits, which together with the abundant deformation twins, support a shock transformation mechanism for microdiamond formation within the Kenna meteorite. Further supporting this observation, the diamond laths show close alignment of <111> and <110> between domains, consistent with a solid-state transformation from graphite along <0001> and <1-210>, respec-tively [5]. A FIB foil was extracted from a region with mechanical twins, and high resolution STEM analyses reveal cross-cutting veins of graphite and oriented kamacite crystals together with additional sets of {111} nano-twins formed in at least three orientations. Isotopic analyses of C and N reveal sector zoning patterns [cf. 3] that are unre-lated to the diamond substructure identified by EBSD yet consistent with hyperspectral CL images. Conclusions: These data provide new constraints on microdiamond formation within ureilites. The microdia-monds exhibit orientation variants defined by aligned <111> and <110> axes consistent with inherited crystallo-graphic orientations from transformation of a single hexagonal graphite parent crystal [5]. Crosscutting the micro-diamonds are veins of graphite and kamacite, together with additional {111} nanotwins. Taken together these data suggest that microdiamonds from ureilites formed from a solid state, diffusionless transformation from graphite, likely associated with a major shock event, which was subject to subsequent reversion either during decompression or a later deformation event. The N and C isotopic sector zoning is unrelated to diamond microstructures and likely reflects inheritance from the parent graphite crystal.

Ureilite↗

Primary magmatic carbon in ureilites - Evidence from cohenite-bearing metallic spherules

The compositions and mineralogy of metal-sulfide spherules trapped in ureilites are studied. Electron microprobe analyses of metallic phases and sulfides in spherules were conducted and backscattered electron images of metallic spherules in olivine and in ureilites are presented. It is observed that the spherules are composed of cohenite, Fe-Ni metal, troilite, and rare phosphorus-bearing minerals. The intergranular metal and graphite in the ureilites are analyzed. The phase relations of cohenite-bearing spherules are considered. Spherules represent Fe-Ni-C-S alloys that exist as immiscible metallic liquid droplets in the silicate magma from which ureilite olivine and pigeonite crystallized. The data reveal that graphite crystals occur as inclusions in olivine and ureilites and therefore graphite in ureilites is a primary magnetic component. It is hypothesized that graphite is a residue from the solid source materials that melted to produce the ureilite parent magma or crystallized from the magma.

Goodrich, C. A.↗

South pole bang-time diagnostic on the National Ignition Facility

The south pole bang-time (SPBT) diagnostic views National Ignition Facility (NIF) implosions through the lower hohlraum laser entrance hole to measure the time of peak x-ray emission (peak compression) in indirect drive implosions. Five chemical-vapor-deposition (CVD) diamond photoconductive detectors (PCD's) with different filtrations and sensitivities record the time-varying x rays emitted by the target. Wavelength-selecting highly oriented pyrolytic graphite (HOPG) crystal mirror monochromators increase the x-ray signal-to-background ratio by filtering for 11-keV emission. Diagnostic timing and the in-situ temporal instrument response function are determined from laser impulse shots on the NIF. After signal deconvolution and background removal, the bang time is determined to 45-ps accuracy. The x-ray 'yield' (mJ/sr/keV at 11 keV) is determined from the total area under the peak.

36 MATERIALS SCIENCE↗

Ratchet growth in recycled PBX 9502

PBX 9502 is a plastic-bonded high explosive (PBX) containing 95 weight% TATB (triaminotrinitrobenzene) crystals in a polymer binder. TATB crystals are graphitic in nature, with a sheet-like structure and anisotropic CTE. Although the mechanism is not understood, solid-pressed TATB composites have been observed to undergo irreversible volume change ('ratchet growth') upon thermal cycling . This phenomenon has been studied but many aspects remain elusive and uncharacterized. Engineering or performance changes associated with ratchet growth have often been attributed to changes in density alone. We propose that the density changes which accompany ratchet growth involve a unique form of micro-damage distinguishable from the pore structure associated with low-pressed density. We have performed ratchet growth studies on Recycled PBX 9502 between -54 to 80{sup o}C with density changes of about 1.5%. Specimens of the same density were obtained using a lower pressure in the manufacturing process. Comparative measurements were made using quasi-static uniaxial tension tests, as well as micro x-ray computed tomography and ultra-small angle neutron scattering experiments. Through these measurements we have shown that ratchet grown PBX 9502 has properties quite different from predictions based on density alone. The pore size distribution of ratchet grown specimens is unique and easily distinguished from parts pressed to an equivalent density.

36 MATERIALS SCIENCE↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Ion irradiation tolerance of graphene as studied by atomistic simulations

As impermeable to gas molecules and at the same time transparent to high-energy ions, graphene has been suggested as a window material for separating a high-vacuum ion beam system from targets kept at ambient conditions. However, accumulation of irradiation-induced damage in the graphene membrane may give rise to its mechanical failure. Using atomistic simulations, we demonstrate that irradiated graphene even with a high vacancy concentration does not show signs of such instability, indicating a considerable robustness of graphene windows. We further show that upper and lower estimates for the irradiation damage in graphene can be set using a simple model.

36 MATERIALS SCIENCE↗

Design and performance characterisation of the HAPG von Hámos Spectrometer at the High Energy Density Instrument of the European XFEL

The von Hámos spectrometer setup at the HED instrument of the European XFEL is described in detail. The spectrometer is designed to be operated primarily between 5 and 15 keV to complement the operating photon energy range of the HED instrument. Four Highly Annealed Pyrolitic Graphite (HAPG) crystals are characterised with thicknesses of 40 μm or 100 μm and radius-of-curvature 50 mm or 80 mm, in conjunction with either an ePix100 or Jungfrau detector. The achieved resolution with the 50 mm crystals, operated between 6.5 and 9 keV, matches that reported previously: ~8 eV for a thickness of 40 μm, whereas, with an 80 mm crystal of thickness 40 μm, the resolution exceeds that expected. Namely, a resolution of 2 eV is demonstrated between 5–6 keV implying a resolving power of 2800. Therefore, we posit that flatter HAPG crystals, with their high reflectivity and improved resolving power, are a powerful tool for hard x-ray scattering and emission experiments allowing unprecedented measurements of collective scattering in a single shot.

47 OTHER INSTRUMENTATION↗

The NASA atomic oxygen effects test program

The NASA Atomic Oxygen Effects Test Program was established to compare the low earth orbital simulation characteristics of existing atomic oxygen test facilities and utilize the collective data from a multitude of simulation facilities to promote understanding of mechanisms and erosion yield dependence upon energy, flux, metastables, charge, and environmental species. Four materials chosen for this evaluation include Kapton HN polyimide, FEP Teflon, polyethylene, and graphite single crystals. The conditions and results of atomic oxygen exposure of these materials is reported by the participating organizations and then assembled to identify degrees of dependency of erosion yields that may not be observable from any single atomic oxygen low earth orbital simulation facility. To date, the program includes 30 test facilities. Characteristics of the participating test facilities and results to date are reported.

Banks, Bruce A.↗

Status of the Stellar X-Ray Polarimeter for the Spectrum-X-Gamma mission

The Stellar X-Ray Polarimeter (SXRP) uses the polarization sensitivity of a graphite Bragg crystal and a lithium Thomsom scattering target to measure the polarization of X-rays from astrophysical sources. The SXRP is a focal plane detector for the Soviet-Danish SODART telescopes which will be launched on the Soviet Spectrum-X-Gamma mission. The SXRP will be the third orbiting stellar X-ray polarimeter, and should provide an order of magnitude increase in polarization sensitivity over its predecessors.

Kaaret, P.↗

Microstructural characterization of nuclear graphite: from the microscale to the nanoscale

Multiple reactor designs use graphite as a moderator of the nuclear reactions and as structural support. During the lifetime of the reactor, multiple aging factors such as neutron irradiation, oxidation, and temperature along with others induce changes in the microstructure and crystal lattice of graphite components. The pore morphology and crystal structure of some phases in graphite can be used to trace the evolution of irradiation defects and mechanical properties of graphite. We present a combination of results from several microscopy techniques to investigate the differences between nuclear graphite grades and the effects of neutron irradiation and oxidation at multiple length scales. This multiscale approach is needed to understand the microstructural variations caused by the raw materials and manufacturing processes as well as how the different phases of graphite are affected by the reactor environment. The results provide insight into the oxidation- and radiation-induced changes of graphite and create a robust baseline of microstructure information that can be used for the selection of materials for the next generation of nuclear power stations. Moreover, the experiments conducted in this work provide an overview of the advantages and limitations of the most common techniques used to characterize nuclear graphite and how these techniques might be applied to study other carbon-based materials used in the nuclear industry.

Arregui Mena, Jose'↗