Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gold coating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A progress report on grazing incidence optics fabrication and evaluation

The progress being made on a mirror array telescope for high energies (MARTHE) project is reported. As a first step, small mirror flats and full-size Wolter I mirrors are produced that are lacquer coated (mandrels) and then coated with gold or palladium. The up-to-date results of fabricating and testing these mirrors are presented. Currently, results can be provided on the micro-roughness, marco-figure, X-ray scattering, and reflectivity up to 8 keV from flats and Wolter I mirrors as well as optical measurements of the flats.

Teague, Peter F.↗

Analysis of volatiles present in interplanetary dust and stratospheric particles collected on large area collectors

Results are presented from an analysis of six chondritic interplanetary dust particles (IDPs) and 22 other stratospheric particles collected on large-area collector, carried out in order to obtain information on the nature, distribution, and form of volatiles in IDPs. A laser microprobe/mass spectrometer (LMMS) was used to extract volatile elements and molecules from particles larger than 10 microns, and an improved hexane rinsing technique was developed for the removal of contaminants. Results show that, because of contamination from silicone oil, freon, and hexane, most of the LMMS signal from IDPs can be interpreted as arising from contamination. Therefore, a species was not considered indigenous unless the signal was an order of magnitude greater in abundance than that released from a pure contaminant coated on gold.

Hartmetz, C. P.↗

Thin Film Solid Lubricant Development

Tribological coatings for high temperature sliding applications are addressed. A sputter-deposited bilayer coating of gold and chromium is investigated as a potential solid lubricant for protection of alumina substrates during sliding at high temperature. Evaluation of the tribological properties of alumina pins sliding against thin sputtered gold films on alumina substrates is presented.

Benoy, Patricia A.↗

Microfluidics, Chromatography, and Atomic-Force Microscopy

A Raman-and-atomic-force microscope (RAFM) has been shown to be capable of performing several liquid-transfer and sensory functions essential for the operation of a microfluidic laboratory on a chip that would be used to perform rapid, sensitive chromatographic and spectro-chemical analyses of unprecedentedly small quantities of liquids. The most novel aspect of this development lies in the exploitation of capillary and shear effects at the atomic-force-microscope (AFM) tip to produce shear-driven flow of liquids along open microchannels of a microfluidic device. The RAFM can also be used to perform such functions as imaging liquids in microchannels; removing liquid samples from channels for very sensitive, tip-localized spectrochemical analyses; measuring a quantity of liquid adhering to the tip; and dip-pen deposition from a chromatographic device. A commercial Raman-spectroscopy system and a commercial AFM were integrated to make the RAFM so as to be able to perform simultaneous topographical AFM imaging and surface-enhanced Raman spectroscopy (SERS) at the AFM tip. The Raman-spectroscopy system includes a Raman microprobe attached to an optical microscope, the translation stage of which is modified to accommodate the AFM head. The Raman laser excitation beam, which is aimed at the AFM tip, has a wavelength of 785 nm and a diameter of about 5 m, and its power is adjustable up to 10 mW. The AFM is coated with gold to enable tip-localized SERS.

Anderson, Mark↗

Nanostructures Exploit Hybrid-Polariton Resonances

Nanostructured devices that exploit the hybrid-polariton resonances arising from coupling among photons, phonons, and plasmons are subjects of research directed toward the development of infrared-spectroscopic sensors for measuring extremely small quantities of molecules of interest. The spectroscopic techniques in question are surface enhanced Raman scattering (SERS) and surface enhanced infrared absorption (SEIRA). An important intermediate goal of this research is to increase the sensitivity achievable by these techniques. The basic idea of the approach being followed in this research is to engineer nanostructured devices and thereby engineer their hybrid-polariton resonances to concentrate infrared radiation incident upon their surfaces in such a manner as to increase the absorption of the radiation for SEIRA and measure the frequency shifts of surface vibrational modes. The underlying hybrid-polariton-resonance concept is best described by reference to experimental devices that have been built and tested to demonstrate the concept. The nanostructure of each such device includes a matrix of silicon carbide particles of approximately 1 micron in diameter that are supported on a potassium bromide (KBr) or poly(tetrafluoroethylene) [PTFE] window. These grains are sputter-coated with gold grains of 40-nm size (see figure). From the perspective of classical electrodynamics, in this nanostructure, that includes a particulate or otherwise rough surface, the electric-field portion of an incident electromagnetic field becomes concentrated on the particles when optical resonance conditions are met. Going beyond the perspective of classical electrodynamics, it can be seen that when the resonance frequencies of surface phonons and surface plasmons overlap, the coupling of the resonances gives rise to an enhanced radiation-absorption or -scattering mechanism. The sizes, shapes, and aggregation of the particles determine the frequencies of the resonances. Hence, the task of designing a nanostructure to exhibit the desired radiation-absorption properties translates, in large part, to selecting particle sizes and shapes to obtain the desired enhanced coupling of energy from photons to plasmons and phonons. To broaden the spectral region(s) of enhanced absorption, one would select a distribution of particle sizes and shapes.

Anderson, Mark↗

Metal Side Reflectors for Trapping Light in QWIPs

Focal-plane arrays of quantum-well infrared photodetectors (QWIPs) equipped with both light-coupling diffraction gratings and metal side reflectors have been proposed, and prototypes are expected to be fabricated soon. The purpose served by the metal side reflectors is to increase quantum efficiency by helping to trap light in the photosensitive material of each pixel. The reasons for using diffraction gratings were discussed in several prior NASA Tech Briefs articles. To recapitulate: In an array of QWIPs, the quantum-well layers are typically oriented parallel to the focal plane and therefore perpendicular or nearly perpendicular to the direction of incidence of infrared light. By virtue of the applicable quantum selection rules, light polarized parallel to the focal plane (as normally incident light is) cannot excite charge carriers and, hence, cannot be detected. Diffraction gratings scatter normally or nearly normally incident light into directions more nearly parallel to the focal plane, so that a significant portion of the light attains a component of polarization normal to the focal plane and, hence, can excite charge carriers. Unfortunately, light scattered in directions parallel or nearly parallel to the focal plane can escape sideways from the QWIP of a given pixel, as illustrated in Figure 1. The escaped light has made only a single pass through the interior photosensitive volume of the QWIP. The quantum efficiency of the QWIP would be increased by trapping light so that it makes multiple passes through the photosensitive volume. As shown in Figure 2, the sides of the QWIP of each pixel would be coated with gold to reflect escaping light back into the interior.

Gunapala, Sarath↗

Reflectivity Around the Gold M-Edges of X-ray Reflector of the Soft X-Ray Telescope Onboard ASTRO-H

The X-ray astronomy satellite ASTRO-H are equipped with two equivalent soft X-ray telescopes (SXT-I and SXT-S) which cover the energy band 0.3-12 keV. The X-ray reflectors of the SXTs are coated with a gold monolayer by means of the replication technique. A series of gold M absorption edges in the 2-4 keV band causes complex structures in the energy response of the SXTs. In the same band, there are astrophysically important emission lines from Si, Ar and S. Since the SXS has unprecedentedly high spectral resolution, we have measured the reflectivity around the gold M-edges in an extremely fine energy pitch at the synchrotron radiation facility KEK PF BL11-B, with the 2 eV pitch in 2100 eV to 4100 eV band that covers the entire series of the absorption edges (M-I through M-V) at grazing incident angles to the reflectors of 0.5, 0.8, 1.0, 1.2, 1.4 degree, and with a finer pitch of 0.25 eV in the 2200 eV to 2350 eV band where the two deepest M-IV and M-V edges are included. In the resultant reflectivity curves, we have clearly identified the fine structures associated with all the M-edges. Using these data, we calculated atomic scattering factor f1 as a function of X-ray energy, with which we have built the mirror response function which can be applied to the Suzaku spectra. As a result, we have found that discrepancy of the spectral model to the Suzaku data of 4U1630-472 (a black hole transient) and the Crab nebula around the M-edges are significantly reduced from those with the official Suzaku response.

ASTRO-H↗

Conductor-backed coplanar waveguide resonators of Y-Ba-Cu-O and Tl-Ba-Ca-Cu-O on LaAlO3

Conductor-backed coplanar waveguide (CBCPW) resonators operating at 10.8 GHz have been fabricated from Tl-Ba-Ca-O (TBCCO) and Y-Ba-Cu-O (YBCO) thin films on LaAlO3. The resonators consist of a coplanar waveguide (CPW) patterned on the superconducting film side of the LaAlO3 substrate with a gold ground plane coated on the opposite side. These resonators were tested in the temperature range from 14 to 106 K. At 77 K, the best of our TBCCO and YBCO resonators have an unloaded quality factor (Qo) 7 and 4 times, respectively, larger than that of a similar all-gold resonator. In this study, the Qo's of the TBCCO resonators were larger than those of their YBCO counterparts throughout the aforementioned temperature range.

Miranda, F. A.↗

Application of hard coatings to substrates at low temperatures

BIRL, the industrial research laboratory of Northwestern University, has conducted unique and innovative research, under sponsorship from the NASA Marshall Space Flight Center (MSFC), in the application of hard, wear resistant coatings to bearing steels using the high-rate reactive sputtering (HRRS) process that was pioneered by Dr. William Sproul, the principal investigator on this program. Prior to this program, Dr. Sproul had demonstrated that it is possible to apply hard coatings such as titanium nitride (TiN) to alloy steels at low temperatures via the HRRS process without changing the metallurgical properties of the steel. The NASA MSFC program at BIRL had the specific objectives to: apply TiN to 440C stainless steel without changing the metallurgical properties of the steel; prepare rolling contact fatigue (RCF) test samples coated with binary hard coatings of TiN, zirconium nitride (ZrN), hafnium nitride (HfN), chromium nitride (CrN), and molybdenum nitride (MoN), and metal coatings of copper (Cu) and gold (Au); and develop new alloyed hard coatings of titanium aluminum nitride (Ti(0.5)Al(0.5)N), titanium zirconium nitride (Ti(0.5)Zr(0.5)N), and titanium aluminum vanadium nitride.

Sproul, William D.↗

Active cleaning techniques for removing contamination from optical surfaces in space

Research in developing an active cleaning technique for removing contaminants from optical surfaces in space is reported. In situ contamination/cleaning experiments were conducted on gold and platimum coated mirrors, which were contaminated by exposure to UV radiation in a 1,3, butadiene environment. Argon and oxygen plasma exposure cleaned the mirrors equally well. Silicone cleaning experiments were also conducted. Exposure of the contaminated mirrors to helium, oxygen, and hydrogen plasmas restored the reflectance at the shorter wavelengths and degraded it at the longer wavelengths.

Shannon, R. L.↗

Wolter-Schwarzschild optics for the extreme-ultraviolet - The Berkeley stellar spectrometer and the EUV Explorer

The design, fabrication and performance of two Wolter-Schwarzschild grazing incidence optics are described. Both telescopes have been figured by single point diamond turning and have achieved better than 15-arcsec on-axis imaging. The telescope for the stellar spectrometer is an f/10 Type II system with an effective area of 225 sq cm at 250 A and 300 cm2 at 500 A. The primary has a maximum diameter of 38 cm and was fabricated in three elements. The copper-plated aluminum substrate was diamond turned; following nickel plating, the surface was polished and coated with evaporated gold. The performance during a sounding rocket flight is discussed. The prototype telescope for the Extreme Ultraviolet Explorer is an f/1.24 Type I system with an effective field of view of 5.0-deg diameter. The telescope has a maximum diameter of 40 cm and was fabricated as a single element. The aluminum substrate is to be diamond turned; the nickel plated surface will be polished and electroplated with gold. The design choice and defocusing optimization aimed at maximizing the field of view and number of image pixels is examined.

Malina, R. F.↗

Electrochemical Deposition Of Thiolate Monolayers On Metals

Electrochemical method devised for coating metal (usually, gold) surfaces with adherent thiolate monolayers. Affords greater control over location and amount of material deposited and makes it easier to control chemical composition of deposits. One important potential use for this method lies in fabrication of chemically selective thin-film resonators for microwave oscillators used to detect pollutants: monolayer formulated to bind selectively pollutant chemical species of interest, causing increase in mass of monolayer and corresponding decrease in frequency of resonance. Another important potential use lies in selective chemical derivatization for purposes of improving adhesion, lubrication, protection against corrosion, electrocatalysis, and electroanalysis.

Porter, Marc D.↗

Silicon Micromachining for Terahertz Component Development

Waveguide component technology at terahertz frequencies has come of age in recent years. Essential components such as ortho-mode transducers (OMT), quadrature hybrids, filters, and others for high performance system development were either impossible to build or too difficult to fabricate with traditional machining techniques. With micromachining of silicon wafers coated with sputtered gold it is now possible to fabricate and test these waveguide components. Using a highly optimized Deep Reactive Ion Etching (DRIE) process, we are now able to fabricate silicon micromachined waveguide structures working beyond 1 THz. In this paper, we describe in detail our approach of design, fabrication, and measurement of silicon micromachined waveguide components and report the results of a 1 THz canonical E-plane filter.

Filter↗

Meteorite Sample Section Repair at NASA Johnson Space Center

Introduction: Meteorite thin and thick sections are routinely shipped from NASA Johnson Space Center to fulfill sample allocation requests from principle investigators around the world. Sections are also re-turned to JSC when researchers are finished studying them since, in most cases, they can be reused for other studies. The sections are very fragile unfortunately, and sometimes return to us needing repairs. The fol-lowing should give you an idea of how we repair sections here in the very lab where they were created. NOTE: Please do not attempt to repair ANSMET meteorite sections that are in your possession. We will perform the repairs for you at NASA JSC if you send the section back to us. Section Delamination: The majority of the meteorite sections that we produce here are secured to the glass slide using a high quality, two-part epoxy. Occasionally, we are asked to use superglue if the researcher wishes to dismount the section from the slide. Both epoxy and superglue are excellent adhesives, but they both tend to embrittle with time which results in delamination from the slide. Exposure to vacuum can also degrade the adhesion between the sample section and the glass slide. Repeated handling of the slide edges can accelerate delamination and, as a preventive measure, the outer 1-2 mm of epoxy is trimmed from newly created sections at JSC. If conductive tapes (copper, carbon, etc.) are used on the section during analysis, great care must be taken in removing the tape so that the epoxy is not pulled up with it. If in doubt, the tape can be left on the section when it is returned to JSC. Before we perform any repairs to sample sections, carbon, gold, or other coatings are removed. We accomplish this using a slurry of 0.05 micron alumina and 190 proof ethyl alcohol applied to a felt polishing pad fitted to a rotating lap wheel. Coatings are re-moved in this manner from all sections that are re-turned to JSC. The extent of the delamination determines how we proceed with the section repair. If the meteorite sample area of the section is not disturbed, then we carefully remove the delaminated epoxy. This is done using a binocular microscope with a 6X zoom, cut-proof gloves, and a very sharp, single edged razor blade. We cut the delaminated epoxy with the blade angled away from the sample area and using very light pressure. The trimmed section is then cleaned in an ultrasonic bath of 200 proof ethyl alcohol for no more than 10 seconds and carefully dried using a lint-free clean room wipe. The section is then placed into a lab oven at 110o F in preparation for epoxy. We mix the resin and hardener components of the low viscosity epoxy and very small amounts are applied to the cut edges of the section using a needle probe and the binocular microscope. Warming the epoxy helps secure the existing section by filling any voids between the glass slide and the section. After the new epoxy cures, we give the section a light polish on a lap wheel fitted with cotton polishing paper that is charged with 1 micron diamond paste. If the section has delaminated to the point of sample area being lifted from the glass, then it may be irreparable. We employ the above technique along with clamping the section in a Teflon pad arrangement in order to flatten the sample while the epoxy cures. Otherwise, the sample will tend to curl. This works to some degree, but once the sample area curls, it seldom re-turns to the original flatness without cracking or bending. Canada Balsam and Crystalbond: We repair damaged sections that had originally been prepared using Canada Balsam or Crystalbond adhesives through the gradual application of heat. We take great care with these samples since these bonding materials tend to get brittle with age. The section is heated in gradual steps (40-50o F per hour) to the melting point of the adhesive. We repair the sample while the adhesive is fluid and then the section is cooled in the same gradual manner in which it was heated. Slide Cracks and Breaks: Accidents happen. Especially with something as small and fragile as a thin/thick section. We all know someone who has driven a microscope objective into a section. As bad as the damage may look, the section can be repaired in most instances. NOTE: Please do not try to tape or glue section pieces back together prior to returning the dam-aged section. This practice usually renders the section irreparable. If the glass slide is cracked but the section is still in one piece, we repair it by infilling the crack with the low viscosity epoxy mentioned earlier. If the slide is in pieces, we can reassemble it with epoxy on a new backer slide. This is a tricky task as the pieces need to be in the correct plane with respect to each other, especially if the sample area is split among several pieces.

Meteorite↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Evidence for the negative work function associated with positrons in gold.

Observation that positrons which have been thermalized in various moderators and coated with approximately 200-A gold leave the gold surface with an energy which peaks between 0.75 and 2.90 eV. This energy is thought to be associated with a positron or 'negative' work function of gold.

Costello, D. G.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Reflection/suppression coatings for 900 - 1200 A radiation

The design and performance of multiple-layer, selective-reflection, selective-suppression coatings for the 900 - 1200 A band are described. These coatings are designed to optimize both high reflectivity at a desirable wavelength and low reflectivity at an undesirable wavelength. The minimum structure for a selective coating consists of a thin metal or metal oxide layer (50 - 150 A thickness) over an aluminum substrate protected with a semi-transparent dielectric (100 - 1000 A thickness). Predicted coating performance is strongly effected by varying the layer combination and thickness. A graphical method of optimizing the coating layer structure is developed. Aluminum, silicon, their oxides, and gold have been investigated as coating layer materials. A very simple coating with a 1026 to 1216 A reflectivity ratio greater than 100 was fabricated. Such reflection/suppression coatings may be of great utility to spaceborne EUV spectrographs.

Edelstein, Jerry↗