Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “getters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The effect of sulfur and zirconium co-doping on the oxidation of NiCrAl

The adhesion behavior of Al2O3 scales formed on NiCrAl+Zr alloys was examined as a function of both sulfur and zirconium doping levels. In general, very high levels of zirconium were required to counteract the detrimental effects of sulfur. A sulfur-zirconium adherence map was constructed, as determined from the oxidation and spalling behavior in 1100 C cyclic tests. For low sulfur alloys (less than 500 ppma), the amount of zirconium required for adherence at any given sulfur level can be described by Zr greater than 600 S(0.2) (in ppma). These results underscore the importance of sulfur to adhesion mechanisms and suggest that sulfur gettering is a first order effect of reactive element additions to MCrAl alloys.

Smialek, James L.↗

Requirements and designs for Mars Rover RTGs

A typical Rover mission, its requirements, the environment it imposes on the radionuclide thermoelectric generator (RTG), and a design approach for making the RTG operable in such an environment are described. Specific RTG designs for various thermoelectric element alternatives are presented. The results of studies show that current multifoil-insulated GPHS (general-purpose heat source) RTG and Mod-RTG designs can be modified to operate in an environment with an external atmosphere (e.g., Mars). This can be done while the helium generated by the fuel's alpha decay is vented to the external atmosphere. The use of novel selective vents and high-capacity getters is not required. The Rover RTGs can be built from standard, proven GPHS modules and standard SiGe unicouples or SiGe/GaP multicouples, using demonstrated thermoelectric material performance parameters. Rover's 500-W power requirement can be satisfied with two 250-W or four 125-W RTGs, whose sizes are compatible with currently envisaged Rover designs. An auxiliary cooling loop (e.g., water and antifreeze) will be required to cool the RTG while it is within the Rover's aeroshell during launch and transit to Mars.

Schock, A.↗

Alkali metal compatibility testing of candidate heater head materials for a Stirling engine heat transport system

The authors describe work performed as part of the 25-kWe advanced Stirling conversion system project. Liquid alkali metal compatibility is being assessed in an ongoing test program to evaluate candidate heater head materials and fabrication processes at the temperatures and operating conditions required for Stirling engines. Specific materials under evaluation are alloy 713LC, alloy 713LC coated with nickel aluminide, and Udimet 720, each in combination with Waspaloy. The tests were run at a constant 700 C. A eutectic alloy of sodium and potassium (NaK) was the working fluid. Titanium sheet in the system was shown to be an effective oxygen getter. Metallographic and microchemical examination of material surfaces, joints, and their interfaces revealed little or no corrosion after 1000 h. Tests are in progress, with up to 10,000 h exposure.

Noble, Jack E.↗

Hydrogen Annealing Of Single-Crystal Superalloys

Annealing at temperature equal to or greater than 2,200 degrees F in atmosphere of hydrogen found to increase ability of single-crystal superalloys to resist oxidation when subsequently exposed to oxidizing atmospheres at temperatures almost as high. Supperalloys in question are principal constituents of hot-stage airfoils (blades) in aircraft and ground-based turbine engines; also used in other high-temperature applications like chemical-processing plants, coal-gasification plants, petrochemical refineries, and boilers. Hydrogen anneal provides resistance to oxidation without decreasing fatigue strength and without need for coating or reactive sulfur-gettering constituents. In comparison with coating, hydrogen annealing costs less. Benefits extend to stainless steels, nickel/chromium, and nickel-base alloys, subject to same scale-adhesion and oxidation-resistance considerations, except that scale is chromia instead of alumina.

Smialek, James L.↗

Miniature X-Ray Tubes

Miniature x-ray tubes proposed for use in portable instruments used to analyze minerals. Electrons from field emitter (instead of thermionic emitter) accelerated to target to generate x-rays. Fabricated from silicon wafers, micromachined field emitters (MFEs) not subject to breakage or restrictions on lifetimes, and tolerate vacuums that filaments cannot. Miniature x-ray tubes very robust, immune to shock and vibration, and permanently sealed with getter for continued pumping. Combined with solid-state x-ray detectors for analysis of x-ray fluorescence.

Bearman, Gregory H.↗

Microstructural Development of Directionally Solidified Hg(1-x)Zn(x)Se Alloys

Hg(1-x)Zn(x)Se alloys have been studied as an alternative to HgCdTe for the detection of electromagnetic radiation, because the shorter ZnSe and HgSe bonds were predicted to improve lattice stability. Previous studies showed that optical properties were stable with time and that the microhardness was higher than for HgTe based alloys. However, for this material to be commercially viable, compositional variations must be reduced, and the distribution of defects induced by the growth process must be understood. The basic structural properties of bulk materials were characterized, and dislocation etch pit densities were measured to determine whether the addition of Zn to the HgSe lattice reduced the potential for dislocation formation. Hg(0.9)Zn(0.1)Se alloys were directionally solidified using a modified Bridgman-Stockbarger method and in an applied magnetic field. Radial compositional variations were greatly reduced when solidification occurred in an applied magnetic field. The combination of a convex liquid-solid interface shape and a method for reduced wetting produced boules that were a single crystal after reaching full diameter. Observed surface features indicated ampoule wetting could be eliminated using a graphite getter. Microstructural characteristics were greatly improved over HgCdTe alloys, In six boules, a total of only one twin was observed, and no inclusions were found. A method for polishing and producing dislocation etch pits was developed for these alloys, revealing dislocation etch pit densities one to two orders of magnitude less than HgTe based alloys. A kink in the thermal profile during processing of one boule generated more dislocations than did lattice mismatch due to compositional variations. The results of this investigation indicate this alloy has improved microstructural properties and resistance to dislocation formation compared with similar II-VI alloys, and should be further investigated for the detection of electromagnetic radiation.

Cobb, S. D.↗

Advanced far infrared blocked impurity band detectors based on germanium liquid phase epitaxy

This research has shown that epilayers with residual impurity concentrations of 5 x 10(sup 13) cm(exp -3) can be grown by producing the purest Pb available in the world. These epilayers have extremely low minority acceptor concentrations, which is ideal for fabrication of IR absorbing layers. The Pb LPE growth of Ge also has the advantageous property of gettering Cu from the epilayer and the substrate. Epilayers have been grown with intentional Sb doping for IR absorption on lightly doped substrates. This research has proven that properly working Ge BIB detectors can be fabricated from the liquid phase as long as pure enough solvents are available. The detectors have responded at reach minimum wavenumbers. Optimization of the Sb doping concentration should further decrease the photoionization energy of these detectors. Ge BIB detectors have been fabricated that respond to 60 cm(exp -1) with low responsivity. Through reduction of the minority residual impurities, detector performance has reached responsivities of 1 A/W. These detectors have exhibited quantum efficiency and NEP values that rival conventional photoconductors and are expected to provide a much more sensitive tool for new scientific discoveries in a number of fields, including solid state studies, astronomy, and cosmology.

Olsen, C. S.↗

Microstructural Development of Directionally Solidified Hg(1-x)Zn(x)Se Alloys

Hg(1-x)Zn(x)Se alloys have been studied as an alternative to Hg(1-x)Cd(x)Te for the detection of electromagnetic radiation, because the shorter ZnSe and HgSe bonds have been predicted to improve lattice stability. Several ingots with x = 0.1 were directionally solidified using a modified Bridgman-Stockbarger method; one was grown in an applied magnetic field, which greatly reduced radial compositional variations. A method was developed to reduce wetting. This, combined with the convex liquid-solid interface shape, produced boules that were single crystalline after growing about 3.5 cm. Observed surface features indicated ampoule wetting was eliminated using a graphite getter. Microstructural characteristics were greatly improved over HgCdTe alloys. In six boules, a total of only one twin was observed. A method for polishing and producing dislocation etch pits was developed for these alloys, revealing dislocation etch pit densities one to two orders of magnitude less than HgTe-based alloys. A kink in the thermal profile during processing of one boule generated more dislocations than did lattice mismatch due to compositional variations. This alloy has improved microstructural properties and resistance to dislocation formation compared with similar II-VI alloys.

Cobb, S. D.↗

Passive Gas-Gap Heat Switches for Use in Adiabatic Demagnetization Refrigerators

We have designed, built, and tested a gas gap heat switch that works passively, without the need for a separate, thermally activated getter. This switch uses He-3 condensed as a thin film on alternating plates of copper. The switch is thermally conductive at temperatures above about 0.2 K, and is insulating if either end of the switch is below about 0.15 K. The "on" conductance (7 mW/K at 0.25K) is limited by the surface area and gap between the copper leaves, the saturated vapor pressure of the He-3, and the Kapitza boundary resistance between the He-3 and the copper. The "off" conductance is determined by the helium containment shell which physically supports the two conductive ends. We have also designed and are building passive gas gap heat switches which will passively turn off near 1 K and 4 K. For these switches we rely on the rapidly changing vapor pressure of He-4 above neon or copper substrates, respectively, when the coverage is less than one monolayer. The different binding energies of the He-4 to the neon or copper give rise to the different temperatures where the switches transition between the on and off states.

Shirron, P. J.↗

Wetting Angles and Surface Tension of Ge(1-x)Si(x) Melts on Different Substrate Materials

The wetting angles and the surface tension of Ge(1-x)Si(x) melts (0.02 less than x less than 0.13) have been measured on various substrate materials using the sessile drop technique. Fused quartz, sapphire, SiC, glassy carbon, pBN, AIN, and Si3N4 have been used as substrates. The highest and most stable wetting angles were found for pBN substrates with 164 +/- 8 deg., either under forming gas with an additional carbon getter in the system or under active vacuum. The surface tension measurements resulted in a value of +2.2 x 10(exp -3) N/m.at%Si for the concentration dependence delta(gamma)/(delta)C. For the composition range measured, the temperature dependence (delt)gamma/(delta)T showed values similar to those of pure Ge, on average -0.07 x 10(exp -3) N/mK.

Croell, A.↗

The Effect of the Wall Contact and Post-Growth Cool-Down on Defects in CdTe Crystals Grown by 'Contactless' Physical Vapour Transport

A series of cadmium telluride crystals grown by physical vapor transport without contact with the ampoule walls and cooled at different rates were characterized using synchrotron X-ray topography, photoluminescence, and chemical etching. Strain from sticking to silica glass and its effect on the dislocation density is shown. It was found that very fast cool-down increases dislocation density by at least one order of magnitude. None of the samples had random dislocation distributions but coarse clumping of dislocations on the scale of more than 100 microns was more prevalent in slowly cooled crystals. Photoluminescence revealed that slow cooling favored the donor-acceptor luminescence involving complex A centers. This was diminished in fast cooled material; and effect presumed to be due to dislocation gettering. Fast cooling also enhanced the formation of shallow acceptors. Implications for Bridgman growth of CdTe and the vapor growth of CdZnTe are discussed briefly.

Palosz, W.↗

A Compact, Continuous Adiabatic Demagnetization Refrigerator with High Heat Sink Temperature

In the continuous adiabatic demagnetization refrigerator (ADR), the existence of a constant temperature stage attached to the load breaks the link between the requirements of the load (usually a detector array) and the operation of the ADR. This allows the ADR to be cycled much faster, which yields more than an order of magnitude improvement in cooling power density over single-shot ADRs. Recent effort has focused on developing compact, efficient higher temperature stages. An important part of this work has been the development of passive gas-gap heat switches that transition (from conductive to insulating) at temperatures around 1 K and 4 K without the use of an actively heated getter. We have found that by carefully adjusting available surface area and the number of He-3 monolayers, gas-gap switches can be made to operate passively. Passive operation greatly reduces switching time and eliminates an important parasitic heat load. The current four stage ADR provides 6 micro W of cooling at 50 mK (21 micro W at 100 mK) and weighs less than 8 kg. It operates from a 4.2 K heat sink, which can be provided by an unpumped He bath or many commercially available mechanical cryocoolers. Reduction in critical current with temperature in our fourth stage NbTi magnet presently limits the maximum temperature of our system to approx. 5 K. We are developing compact, low-current Nb3Sn magnets that will raise the maximum heat sink temperature to over 10 K.

Shirron, P. J.↗

Development of Ceramic Matrix Composites For High Temperature Applications

The microstructure and mechanical properties of carbon fiber reinforced silicon carbide (C/SiC) composites that incorporated molecular-level oxidation inhibitors designed to increase the material s high temperature durability were characterized. The viability of a fiber-level inhibitor incorporated as part of a layered interface system as well as a molecularly-integrated matrix-level oxidation inhibitor that is co-deposited with the SiC matrix during Chemical Vapor Infiltration (CVI) was determined. It was expected that the inhibitor would act as a glass former that will getter the oxygen and form a crack sealant to reduce further ingress of oxygen into the composite. Three composites were examined. Composite A was a baseline C(sub f)/SiC(sub m) composite that incorporated a approx. 0.4 micron pyrolytic carbon (PyC) fiber coating to promote strength and toughness, and a CVI-derived SiC matrix. Composite B was a C(sub f)/SiC(sub m) composite incorporating a approx 0.4 micron pyrolytic carbon (PyC) fiber coating to promote strength and toughness, a approx. 0.6 micron B4C fiber-level oxidation barrier coating, and a CVI-derived SiC matrix. Composite C was a C(sub f) /SiC(sub m) composite that incorporated a approx. 0.4 micron pyrolytic carbon (PyC) fiber coating to promote strength and toughness, a approx. 0.6 micron B4C fiber-level oxidation barrier coating, and a BxC-SiC oxidation-inhibited matrix produced by CVI co-deposition. All composites were reinforced with 10 plies of T-300 balanced plain weave carbon fabric with 3K tows at 12.5 ends per inch.

Heimann, Paula↗

Miniaturized Mercury Ion Clock for Ultrastable Deep Space Applications

We have recently completed a prototype ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~2-3x10-13 at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly 1.5 years with no measurable degradation of ion trapping lifetimes or clock short-term performance. Because the tube is sealed, the Hg source and Neon buffer gas are held indefinitely, for the life of the tube. There is no consumption of Hg in this system unlike in a Cs beam tube where lifetime is often limited by Cs depletion.

mercury ion clocks↗

Low temperature storage container for transporting perishables to space station

Two storage containers are disclosed within which food or biological samples may be stored for transfer in a module by the space shuttle to a space station while maintaining the food or samples at very low temperatures. The container is formed in two parts, each part having an inner shell and an outer shell disposed about the inner shell. The space between the shells is filled with a continuous wrap multi-layer insulation and a getter material. The two parts of the container have interlocking members and when connected together are sealed for preventing leakage from the space between the shells. After the two parts are filled with frozen food or samples they are connected together and a vacuum is drawn in the space between the shells and the container is stored in the module. For the extremely low temperature requirements of biological samples, an internal liner having a phase change material charged by a refrigerant coil is disposed in the space between the shells, and the container is formed from glass fiber material including honeycomb structural elements. All surfaces of the glass fiber which face the vacuum space are lined with a metal foil.

Owen, James W.↗

High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suite Gas Processing System (GPS) Carbon Dioxide Scrubber

In support of the GPS for the SAM instrument suite built by NASA/GSFC, a life test facility was developed to test the suitability of 80Ni-20Cr alloy wire, 0.0142 cm diameter, for use as a heater element for the carbon dioxide scrubber. The element would be required to operate at 1000 C in order to attain the 800 C required for regeneration of the getter. The element also would need to operate in the Mars atmosphere, which consists mostly of CO2 at pressures between 4 and 12 torr. Data on the high temperature degradation mechanism of 80Ni- 20Cr in low pressure CO2, coupled with the effects of thermal cycling, were unknown. In addition, the influence of work hardening of the wire during assembly and the potential for catastrophic grain growth also were unknown. Verification of the element reliability as defined by the mission goals required the construction of a test facility that would accurately simulate the duty cycles in a simulated Mars atmosphere. The experimental set-up, along with the test protocol and results will be described.

Hoffman, Christopher↗

Neon as a Buffer Gas for a Mercury-Ion Clock

A developmental miniature mercury-ion clock has stability comparable to that of a hydrogen-maser clock. The ion-handling components are housed in a sealed vacuum tube, wherein a getter pump is used to maintain the partial vacuum, and the evacuated tube is backfilled with mercury vapor in a buffer gas. Neon was determined to be the best choice for the buffer gas: The pressure-induced frequency pulling by neon was found to be only about two-fifths of that of helium. Furthermore, because neon diffuses through solids much more slowly than does helium, the operational lifetime of a tube backfilled with neon could be considerably longer than that of a tube backfilled with helium.

Prestage, John↗

High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suit Gas Processing System (GPS) Carbon Dioxide Scrubber

In support of the GPS for the SAM instrument suite built by GSFC, a life test facility was developed to test the suitability of 80Ni-20Cr wire, 0.0056 inches in diameter, for use as a heater element for the carbon dioxide scrubber. The wire would be required to operate at 1000 C in order to attain the 800 C required for regeneration of the getter. The wire also would need to operate in the Mars atmosphere, which consists mostly of CO2 at pressures between 4 and 12 torr. Data on the high temperature degradation mechanism of 80Ni-20Cr in low pressure CO2, together with the effects of thermal cycling, were unknown. In addition, the influence of work hardening of the wire during assembly and the potential for catastrophic grain growth also were unknown. Verification of the wire reliability as defined by the mission goals required the construction of a test facility that would accurately simulate the duty cycles in a simulated Mars atmosphere. The experimental set-up, along with the test protocol and results will be described.

Gundersen, Cynthia↗