Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “galvanic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

Mechanical and Corrosion Assessment of Friction Self-Piercing Rivet Joint of Carbon Fiber-Reinforced Polymer and Magnesium Alloy AZ31B

In the present work, thermoset carbon fiber–reinforced polymer (CFRP) was spot joined to magnesium alloy AZ31B by a friction self-piercing riveting (F-SPR) process. Lap shear tensile and cross-tension testing were used to evaluate the mechanical joint performance. An average lap shear tensile load of 5.18 kN was achieved, while an average of 2.81 kN was found from cross-tension testing. All F-SPR samples showed a pullout of AZ31B after mechanical testing, indicating good mechanical interlocking between the steel rivet and AZ31B. Corrosion potential was measured for each material to establish the galvanic corrosion characteristics. As expected, AZ31B was found to be the most active, while thermoset CFRP was the most noble. The steel rivet fell between the AZ31B (active) and the thermoset CFRP (noble). Salt fog corrosion testing (ASTM B-117) was performed to evaluate the corrosion performance of the uncoated F-SPR joint. With up to 200 h of exposure, the post-corroded F-SPR joint integrity retained 81.2% of the pre-exposure F-SPR joint strength with AZ31B pullout failure mode. From cross-sectional analysis of the F-SPR joint, extensive corrosion of AZ31B was observed at the joint and other exposure areas. However, steel rivet was not significantly corroded due to sacrificial anode effect by which AZ31B corroded first in the galvanic couple.

36 MATERIALS SCIENCE↗

MECHANICAL AND CORROSION ASSESSMENT OF FRICTION SELF-PIERCING RIVET JOINT OF CARBON FIBER-REINFORCED POLYMER AND MAGNESIUM ALLOY AZ31B

In the present work, thermoset carbon fiber–reinforced polymer (CFRP) was spot joined to magnesium alloy AZ31B by a friction self-piercing riveting (F-SPR) process. Lap shear tensile and cross-tension testing were used to evaluate the mechanical joint performance. An average lap shear tensile load of 5.18 kN was achieved, while an average of 2.81 kN was found from cross-tension testing. All F-SPR samples showed pull-out of AZ31B after mechanical testing, indicating good mechanical interlocking between the steel rivet and AZ31B. Corrosion potential was measured for each material to establish the galvanic corrosion characteristics. As expected, AZ31B was found to be the most active, while thermoset CFRP was the most noble. The steel rivet fell between the AZ31B (active) and the thermoset CFRP (noble). Salt fog corrosion testing (ASTM B-117) was performed to evaluate the corrosion performance of the uncoated F-SPR joint. With up to 200 h of exposure, the post-corroded F-SPR joint integrity retained 81.2% of the pre-exposure F-SPR joint strength with AZ31B pull-out failure mode. From cross-sectional analysis of the F-SPR joint, extensive corrosion of AZ31B was observed at the joint and other exposure areas. However, steel rivet was not significantly corroded potentially due to sacrificial anode effect by which AZ31B corroded first in the galvanic couple.

Lim, Yong Chae↗

High Temperature Optocoupler for 3D High Density Power Modules

The goal of this proposed research is to develop a reliable high-temperature optocouplers, which can operate at 250°C with at least ten-year lifetime, and replace isolation transforms as the galvanic isolation solution for the 3D integration of high density power modules. The electrification of future transportations (i.e., electric vehicles) will continuously drive the demand for high density power modules. Optocouplers (i.e., packaged light emitter and detector) as a promising candidate to replace bulky isolation transformers are highly desirable to facilitate the continuous scale-down of gate driver circuitry that will lead to 3D high density power modules and achieve disruptive performance in terms of thermal management, power density, power efficiency, reliability and operating environments. However, regular semiconductor optoelectronic materials and devices have significant difficulty functioning in the harsh environments designated for high density power module usage (such as operation at high temperatures). Ultimately, it is not the intrinsic properties of power devices that prevent their use at higher temperatures, but rather the low voltage electronics needed to drive them and the packaging that surrounds them. The typical operating temperature for optocouplers is only up to 100°C, due to the limitations of light emitting diode (LED) devices inside and packaging materials. A systematic characterization methodology will be developed to analyze the performance, lifetime and reliability of LED devices and distinguish multiple failure mechanisms at high temperatures. An original methodology of “design for reliability” will be developed to design the optoelectronic devices with high reliability and long lifetime at high temperatures. A new architecture of high temperature high reliable optocouplers will be developed, fabricated and demonstrated with continuous operating at 250°C. The development of efficient, reliable high density 3D power modules is the foundation for energy efficiency and energy reliability. Enabled with advanced 3D integration and packaging technologies, high density power module solutions can achieve much more superior performance over the conventional discrete solutions in terms of efficiency, thermal management and power density. The proposed concept of high temperature optocouplers as the galvanic isolation solution for high density power modules will bring together interdisciplinary research involving the wide bandgap materials, optoelectronics, high reliable device design, electronics packaging and power modules. A streamline of skilled personnel would be trained including graduate and undergraduate students, local engineers and scientists which are in great demand to both academia and optoelectronics industry. The proposed research topics, such as, solid state lighting and high temperature device reliability, are currently of major interest at the Department of Energy, in particular, Sandia National Laboratories. This project can enhance collaborations between the University of Arkansas (UA) and Sandia National Laboratories. The findings of the proposed research are expected to be integrated into high density 3-D power modules at the Engineering Research Center for Power Optimization for Electro-Thermal Systems (POETS).

42 ENGINEERING↗

Evaluation of inorganic zinc-rich primers using Electrochemical Impedance Spectroscopy (EIS) in combination with atmospheric exposure

This investigation explored the use of Electrochemical Impedance Spectroscopy (EIS) in combination with atmospheric exposure as a short term method for analyzing the performance of twenty-one commercially available zinc-rich primers. The twenty-one zinc-rich primers were: Carboline CZ-11, Ameron Devoe-Marine Catha-Coat 304, Briner V-65, Ameron D-21-9, Sherwin Williams Zinc Clad II, Carboline CZ-D7, Ameron D-4, Dupont Ganicin 347WB, Porter TQ-4374H, Inorganic Coatings IC-531, Subox Galvanox IV, Southern Coatings Chemtec 600, GLidden Glidzinc 5530, Byco SP-101, Tnemec 90E-75, Devoe Catha-Coat 302H, Glidden Glidzinc 5536, Koppers 701, Ameron D-21-5, Coronado 935-152, and Subox Galvanox V. Data were also collected on galvanized steel for comparison purposes. A library of Bode magnitude plots was generated for each coating including curves for the initial time and after each week of atmospheric exposure at the Beach Corrosion Test site near the Space Shuttle launch pad at the Kennedy Space Center for up to four weeks. Subsequent measurements were collected after 8 weeks and after one year of atmospheric exposure. Analysis of the impedance data was performed with the purpose of identifying parameters that could be used to predict the long-term performance of zinc-rich primers. It has been shown that there is a correlation between the long-term performance of zinc-rich primers and several parameters obtained from EIS measurements in combination with atmospheric exposure. The equivalent circuit R2(R2C(R3W)) provided a satisfactory fit for the EIS data. The corrosion potential and the R2 resistance are parameters indicative of the galvanic mechanism of protection. The capacitance of the coating is related to the barrier mechanism of protection.

Calle, Luz M.↗

Cathodic Protection Deployment on Space Shuttle Solid Rocket Boosters

Corrosion protection of the space shuttle solid rocket boosters incorporates the use of cathodic protection(anodes) in concert with several coatings systems. The SRB design has large carbon/carbon composites(motor nozzle) electrically connected to an aluminum alloy structure. Early in the STS program, the aluminum structures incurred tremendous corrosive attack due primarily to the galvanic couple to the carbon/carbon nozzle at coating damage locations. Also contributing to the galvanic corrosion problem were stainless steel and titanium alloy components housed within the aluminum structures and electrically connected to the aluminum structures. This paper will highlight the evolution in the protection of the aluminum structures, providing historical information and summary data from the operation of the corrosion protection systems. Also, data and information will be included regarding the evaluation and deployment of inorganic zinc rich primers as anode area on the aluminum structures.

Zook, Lee M.↗

Electrochemical Measurement of Atmospheric Corrosion

Corrosion of Shuttle thruster components in atmospheres containing high concentrations of nitrogen tetroxide (NTO) and water is an important issue in ground operations of bipropellant systems in humid locations. Measurements of the corrosivities of NTO-containing atmospheres and the responses of different materials to these atmospheres have been accomplished using an electrochemical sensor. The sensor is composed of alternating aluminum/titanium strips separated by thin insulating layers. Under high humidity conditions a thin film of water covers the surface of the sensor. Added NTO vapor reacts with the water film to form a conductive medium and establishes a galvanic cell. The current from this cell can be integrated with respect to time and related to the corrosion activity. The surface layer formed from humid air/NTO reacts in the same way as an aqueous solution of nitric acid. Nitric acid is generally considered an important agent in NTO corrosion situations. The aluminum/titanium sensor is unresponsive to dry air, responds slightly to humid air (> 75% RH), and responds strongly to the combination of humid air and NTO. The sensor response is a power function (n = 2) of the NTO concentration. The sensor does not respond to NTO in dry air. The response of other materials in this type of sensor is related to position of the material in a galvanic series in aqueous nitric acid. The concept and operation of this electrochemical corrosion measurement is being applied to other corrosive atmospheric contaminants such as hydrogen chloride, hydrogen fluoride, sulfur dioxide, and acidic aerosols.

DeArmond, Anna H.↗

Role of irregular otolith afferents in the steady-state nystagmus during off-vertical axis rotation

1. During constant velocity off-vertical axis rotations (OVAR) in the dark a compensatory ocular nystagmus is present throughout rotation despite the lack of a maintained signal from the semicircular canals. Lesion experiments and canal plugging have attributed the steady-state ocular nystagmus during OVAR to inputs from the otolith organs and have demonstrated that it depends on an intact velocity storage mechanism. 2. To test whether irregularly discharging otolith afferents play a crucial role in the generation of the steady-state eye nystagmus during OVAR, we have used anodal (inhibitory) currents bilaterally to selectively and reversibly block irregular vestibular afferent discharge. During delivery of DC anodal currents (100 microA) bilaterally to both ears, the slow phase eye velocity of the steady-state nystagmus during OVAR was reduced or completely abolished. The disruption of the steady-state nystagmus was transient and lasted only during the period of galvanic stimulation. 3. To distinguish a possible effect of ablation of the background discharge rates of irregular vestibular afferents on the velocity storage mechanism from specific contributions of the dynamic responses from irregular otolith afferents to the circuit responsible for the generation of the steady-state nystagmus, bilateral DC anodal galvanic stimulation was applied during optokinetic nystagmus (OKN) and optokinetic afternystagmus (OKAN). No change in OKN and OKAN was observed.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Neuroscience↗

Watching the Blue Planet from Space over Recent Decades: What's up for Science and Society?

Since the first photographs of “Earth Rise” taken by the Apollo astronauts in the 1960s galvanized the environmental movement, imaging of our planet from low Earth orbit has grown more sophisticated and diverse. Satellite and astronaut observations and imagery of the changing ocean still have the power to galvanize oceanographers and society. So what are some of the key ideas for oceanography and society that come out of out recent decades of ocean observation from space? Satellite oceanography has made fundamental contributions to our understanding and estimation of changing sea level, winds and storminess over the oceans, primary productivity of the seas, the role of the ocean in the water cycle, and the changes in the ocean known as ocean acidification. Some of these phenomena interact in complex ways and Mother Nature hides the future well. However, some things are clear. Sea level rise has been monitored from space for more than 20 years and now we have a more nuanced understanding of regional variation in sea level rise and the contributions of ocean thermal expansion and the melting of glaciers and ice sheets. Wind vectors at the ocean surface have been measured for more than 2 decades and provide evidence for shifts in wind patterns that help, for example, explain some of the regional variations in sea level rise. Chlorophyll-a has been estimated in a multi-decadal record of observations and is being used to describe the shifts and trends in ocean primary productivity. Sea surface temperature estimation from space has records going back to the 1970s and provides critical information for the interaction of the ocean with the atmosphere. Sea surface salinity has been measured from space only within the last decade and provides a novel new view of regional, seasonal, and inter-annual changes in the ocean related to precipitation, river run-off, and eddy transport. Potential changes in the Earth’s water cycle have a huge societal impact.

Blue Planet from Space↗

ECLSS Universal Waste Management System (UWMS) Metal Materials Compatibility Study - Elgiloy: Electrochemical and Crevice Corrosion Evaluation

Electrochemical evaluations were conducted on samples of Elgiloy in support of the materials compatibility program for the Environmental Control and Life Support System (ECLSS). Results were compared alongside three previously tested metals: Titanium 6Al-4V, Inconel 625, and Hastelloy C276. Titanium exhibited the best results of all the metals, indicating superior corrosive nobility and galvanic protection properties. Elgiloy demonstrated anti-corrosion behavior which appeared to be superior to the two nickel-chromium alloys. For this current effort, the results have clearly shown that Elgiloy possesses excellent corrosion protection properties and is galvanically compatible with the other three metals in the subject test media.

Lee, R. E.↗

Considerations on Electrolytic Conductivity Measurement for Monitoring of Ionic Silver Biocide Dosing

NASA interest in ionic silver (Ag+) as a biocide for spacecraft potable water systems motivates the development of Ag+ concentration sensors to ensure nominal dosing. The electrolytic conductivity change of highly-purified potable water is linearly related to the concentration of chemically-dosed Ag+ and could serve as a useful proxy measurement, while the conductivity change during electrolytic dosing may be less so, depending on the influent water chemistry and electrolytic efficiency. Understanding and mitigating the potentially deleterious effects of Ag+ interaction with conductivity measurement systems requires investigation. Issues associated with traditional conductivity cells, which rely on wetted(typically metal or graphite) electrodes, and capacitively-coupled contactless conductivity detection (C4D) for this application are considered. Traditional conductivity cells may potentially be subject to significant excitation-induced or auto-galvanic reduction of Ag+. These may result in Ag+ depletion or electrode fouling and associated measurement error. Proper selection of electrode material, excitation parameters, and cell geometry may limit such effects. C4D uses electrodes placed outside an inert, insulating material, with dielectric polarization enabling the production of an electric field and resultant current across the analyte solution. This approach could potentially mitigate problems with Ag+ depletion and fouling by eliminating the possibility of auto-galvanic deposition and reducing the Faradaic current density. However, it is necessary to confirm C4D performance at very low conductivity levels and to determine if long-term operation produces conductive deposits, which could result in measurement error. A commercial C4D system with 1/16” (1.59 mm)outer diameter flow tubing and claimed performance in the conductivity range appropriate for this application was identified, and its sensitivity in the upper parts of this range was confirmed in a preliminary experiment. A concept for a C4D detector that could allow for full rate flow-through using planar electrodes and thin-film dielectric layers is discussed.

silver↗

Advanced Material Options for the Portable Life Support System

Meeting an aggressive mass requirement is a challenge for new space suit development efforts, including that of the Exploration Extravehicular Mobility Unit Portable Life Support System (PLSS) government reference design. To reduce overall system mass, titanium was selected as the primary metal for the PLSS backplate and thermal loop. However, galvanically compatible metals (Hastelloy, Inconel, Monel) have relatively high densities and require further design complexities such as coatings and more challenging manufacturing. Efforts to reduce the mass of the government reference design for an International Space Station (ISS) or lunar mission were halted due to the government’s transition to a commercial Extravehicular Activity (EVA) services approach, but research was conducted into methodologies for mass savings using advanced materials. With the advent of a lunar Artemis mission and potential for future Mars missions, mass becomes a more critical driver going forward. Therefore, alternative materials and processes must be considered to fully close the mass requirement. There are many new materials and processes that can be considered; however, considerations must be made to ensure galvanic compatibility, radiation concerns for sensitive electronics, vacuum compatibility, tight tolerances, fluid compatibility with oxygen and water, and thread insert options. Individual PLSS components may have different requirements and need to be considered separately for reducing overall mass. This report will touch on comparisons between advanced materials, focusing on composites, additive manufacturing, and plastics. It will also address the different processes that may need to be applied when using these materials in the harsh environment of space. Lastly, it will look at specific components and make recommendations for options to reduce the mass of each one.

Ryan Ogilvie↗

Advanced Material Options for the Portable Life Support System (PLSS)

Meeting an aggressive mass requirement is a challenge for new space suit development efforts, including that of the Exploration Extravehicular Mobility Unit Portable Life Support System (PLSS) government reference design. To reduce overall system mass, titanium was selected as the primary metal for the PLSS backplate and thermal loop. However, galvanically compatible metals (Hastelloy, Inconel, Monel) have relatively high densities and require further design complexities such as coatings and more challenging manufacturing. Efforts to reduce the mass of the government reference design for an International Space Station (ISS) or lunar mission were halted due to the government’s transition to a commercial Extravehicular Activity (EVA) services approach, but research was conducted into methodologies for mass savings using advanced materials. With the advent of a lunar Artemis mission and potential for future Mars missions, mass becomes a more critical driver going forward. Therefore, alternative materials and processes must be considered to fully close the mass requirement. There are many new materials and processes that can be considered; however, considerations must be made to ensure galvanic compatibility, radiation concerns for sensitive electronics, vacuum compatibility, tight tolerances, fluid compatibility with oxygen and water, and thread insert options. Individual PLSS components may have different requirements and need to be considered separately for reducing overall mass. This report will touch on comparisons between advanced materials, focusing on composites, additive manufacturing, and plastics. It will also address the different processes that may need to be applied when using these materials in the harsh environment of space. Lastly, it will look at specific components and make recommendations for options to reduce the mass of each one.

Ryan Ogilvie↗

ZnCr and ZnNb Cold Spray Coatings

Novel cold spray zinc-based alloy coatings have been investigated for corrosion protection of API 5L low carbon steel pipelines used in transporting natural gas. These different zinc alloy coatings are designed for use to help prevent internal corrosion and improve the lifespan of steel pipelines via sacrificial anodic protection. The corrosion behavior of these cold deposited zinc alloy coatings was investigated in CO2 saturated 3.5 wt.% NaCl solutions under simulated natural gas pipeline conditions. Electrochemical tests were conducted at 25 and 40 °C to determine the polarization resistance and galvanic current between each coating and the steel substrate in the galvanic couple. Tests were conducted at atmospheric, 1 bar, pressure. The results indicate that use of these coatings has the potential to increase the lifespan of steel pipelines above what a zinc coating alone could provide.

Teeter, Lucas↗

Synthesis and Characterization of Pd-based Nanomaterials

Bimetallic nanoparticles (BNPs) consist of two different types of metals or alloys that are bonded together. Unique properties such as optical, electronic, thermal, and catalytic effects differ for each type of BNP. Important BNPs range from Au-Pd, Ag- Pt, Au-Pt, and Ag-Ni. Pd bimetallic nanoparticles are of interest due to their many applications such as catalysis and sensing. Bimetallic catalysts have increase reaction rates and have improved catalyst stability through the geometry and ligand distribution. Pd nanoparticles are considered to be a strong catalyst due to their high activity at low temperatures and high tolerance to moisture. The catalytic properties of bimetallic nanoparticles depend on the structural properties such as size and shape. Core-shell, hollow structure, and multi-shell alloy are three possible structures nanoparticles can form as bimetallic catalysts. BNPs can be synthesized through different methods to control the size, shape, and structure. To obtain different morphologies, a variety of methods can be performed. Different methods can range from the usage of the glancing angle deposition (GLAD) to the galvanic replacement reaction, but the methods all depend on the properties of the metals. The galvanic displacement reaction was the method used to obtain Pd-based nanoparticles. This reaction is best know for obtaining hollow shaped NPs. To determine what redox process was preformed, the activity series of metals was used. From the activity series of metals, silver (Ag) was selected to preform Pd-based nanoparticles. Objectives: Synthesize Ag nanoparticles and Ag-Pd nanoparticles to understand the morphology. Characterize the synthesized nanoparticles using scanning electron microscopy (SEM), phase analysis light scattering (PALS), dynamic light scattering (DLS), energy dispersive X-ray spectroscopy (EDS), and UV-Vis spectroscopy. Results: In the UV-Vis spectrum, the Ag-Pd bimetallic NP's plasmon band decreased as the volume of palladium increased. The surface charge increases as the concentration of palladium increases. The Pd{sup 2+} ions interact with the sodium citrate surface, and decrease the negative charge. Conclusion: Ag-Pd nanoparticles were successfully created and stabilized with sodium citrate. The addition of Pd decreased the prominent plasmon band of the Ag nanoparticles. The SEM analysis showed that Ag nanoparticles had a well-defined structure, while the Ag-Pd nanoparticles showed hollow and rough structure. The EDX analysis confirmed the presence of silver and palladium. This material can be used in many industrial and research fields such as organic synthesis, fuel cells, and environmental sensing and remediation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Augmented Monitoring and Condition Assessment Program for SNF Wet Storage Life Extension - 20489

Approximately 27 MTHM of spent nuclear fuel (SNF) owned and managed by the U.S. Department of Energy, Office of Environmental Management is stored in the L Basin at the Savannah River Site (SRS). This 'DOE SNF' is comprised of approximately 12,000 aluminum-clad, aluminum-based fuel assemblies (∼7 MTHM), and approximately 2000 non-aluminum fuel assemblies (∼20 MTHM). A program is in progress to perform Non-Destructive Examination (NDE) of the fuel and their storage containers to characterize the materials' condition, and to evaluate the effects of service to enable continued safe wet storage of the SNF. The Augmented Monitoring and Condition Assessment Program (AMCAP), a two-part program to develop and implement remote underwater Non-Destructive Examination of the aluminum SNF, and of the containers of the non-aluminum SNF, respectively, is aimed at the characterization and evaluation of corrosion degradation of aluminum fuel and container materials. The predominant design of the aluminum SNF (ASNF) stored in L Basin is the Materials Test Reactor (MTR) equivalent design, a plate fuel design. These SNF are stored in 5'' diameter tubes or 5'' x 5'' squares (called bundles) that are nominally 12' or up to 14' long. The SNF is de-bundled and inspected using a custom-designed MTR Fuel Inspection Table. The inspection table provides for indexed fuel positioning for a video camera examination with controlled lighting. A total of 10 of the SNF originating from foreign research and test reactors were selected for examination based on burnup, enrichment, and prior damage caused by service/storage history. A special inspection campaign of these 10 assemblies is in progress. The observed corrosion damage included minor to moderate attack from general corrosion, pitting, crevice, end grain and galvanic corrosion. Example results from the completed inspections are shown and discussed. The focus is a comparison of the as-received condition versus the as-found current storage condition that will serve to validate Water Chemistry and Corrosion Monitoring Programs. The non-aluminum SNF (NASNF) stored in L Basin are of diverse design that includes various geometries with claddings of stainless steel, Zircaloy, and Hastelloy. The fuel core materials include uranium alloys, oxides/mixed oxides, and carbides. These SNF materials, originating from early experimental and test reactors, are in various physical forms including single fuel elements and cut pieces. The fuel is stored in L Basin in various configurations including in direct bundled storage in aluminum tubes and in isolation cans that are in the bundles or in a larger over-size storage container (OSC). Concern with inside-out corrosion and the potential loss of configuration control and ability to handle the storage containers prompted the development of remote NDE methods that include visual and UT technologies to assess the condition of the containers. Candidate stored materials were selected for a special inspection campaign; the development of the NDE methods for the inspection for galvanic, crevice and sediment-induced corrosion (inside-out) are discussed. A summary of the SNF storage in L Basin at the SRS, and an overview of the AMCAP to enable continued safe storage of DOE SNF are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion behavior in aluminum/galvanized steel resistance spot welds and self-piercing riveting joints in salt spray environment

Here, this paper underlined the corrosion behavior of aluminum alloy/galvanized steel joints fabricated by resistance spot welding (RSW) and self-piercing riveting (SPR) exposed to different salt-spray cycles. It was found that the crevice generated by different joining methods has an important impact on corrosion behavior. Compared with the RSW joint, less corrosion happened on the coupled regions in SPR joints because of the higher local pH value resulted from the smaller crevice. The crevice, however, has less impact on the types of corrosion products. Galvanic corrosion happened in the coupled region for both RSW and SPR joints. The Pourbaix diagram explained the stable corrosion products of Al and Zn—Fe alloy, which are Al 2 O 3 , ZnO, and Fe 3 O 4 . Additional corrosion products observed from the experiment included α-Al(OH) 3 , Ca 4 Al 2 (CO 3 )(OH) 12 (H 2 O) 5 , Zn 5 (OH) 8 Cl 2 (H 2 O), Zn 5 (CO 3 ) 2 (OH) 6 , and Fe 2 (OH) 2 (CO 3 ), which can be understood by considering the metastable corrosion products, Pourbaix diagram, and possible chemical reactions.

36 MATERIALS SCIENCE↗

A new method for detecting abrupt changes in the dependence among multivariate hydrological series based on moving cut total correlation

Knowledge of how to define and estimate the dependence among multivariate hydrological series is essential for detecting abrupt changes in the dependence. Here, in this paper, a new method (BMCTC) is proposed to detect all possible abrupt change points in the dependence among multivariate hydrological series. The total correlation estimated by the matrix-based Renyi's alpha-order entropy functional is firstly introduced to define and measure the dependence strength among multivariate hydrological series. Then, the moving cut total correlation (MCTC) sequence is built by the moving window technique, which is used to measure changes in the dependence strength among multivariate hydrological series. Finally, the Bernaola-Galvan algorithm is used to detect all change points of the MCTC sequence. Simulations are performed to compare the effectiveness of BMCTC with Pearson correlation (BMCPC) and Spearman correlation (BMCSC), Cramer-von Mises (CvM) and copula-based likelihood-ratio (CLR). The results show that all change points are detected by BMCTC regardless of the samples size, but wrong change points or no change points are detected by other methods in most cases. BMCTC is applied to detect change points in the dependence among annual runoff, precipitation and sediment discharge series in the Xiliugou and the Kuyehe River, China. It is found that the dependence among runoff, precipitation and sediment discharge changed abruptly in 1980 and 1996 in the Kuyehe River and in 1999 in the Xiliugou River. These changes are mainly caused by human activities such as construction of water conservancy projects and coal mining.

54 ENVIRONMENTAL SCIENCES↗