Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “full stack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

NESC Ceramic Oxygen Generator (COG) Technology Development

The NASA Engineering and Safety Center (NESC) sponsored a project to accelerate the pace of technology development of a ceramic oxygen generator (COG), for NASA and COVID related medical use. NASA applications for this technology include spacesuit oxygen tank recharge, medical applications include providing medical oxygen in remote and low resource settings. During this project, five full-scale (i.e., 30 wafer) cell stacks were built and tested in prototype systems capable of producing pressurized oxygen. System testing measured oxygen product purity, delivery pressure, production rate, and energy use. This report describes ion transport membrane mechanisms, cell stack configuration, and test results.

Oxygen↗

Bringing OpenCL to Commodity RISC-V CPUs

The importance of open-source hardware has been increasing in recent years with the introduction of the RISC-V Open ISA. This has also accelerated the push for support of the open-source software stack from compiler tools to full-blown operating systems. Parallel computing with today’s Application Programming Interfaces such as OpenCL has proven to be effective at leveraging the parallelism in commodity multi-core processors and programmable parallel accelerators. However, to the best of our knowledge, there is currently no publicly available implementation of OpenCL targeting commodity RISC-V processors that is accessible to the open-source community. Besides opening RISC-V to the existing rich variety of scientific parallel applications, OpenCL also provides access to a unique genre of benchmarks useful in computer architecture research. In this work, we extended an Open-source implementation of OpenCL to target RISC-V CPUs. Our work not only cover commodity multi-core RISC-V processors, but also plethora of low- profile embedded RISC-V CPUs that often do not support atomic instructions or multi-threading.

Tine, Blaise↗

Hollow Fiber Spacesuit Water Membrane Evaporator Development and Testing for Advanced Spacesuits

The spacesuit water membrane evaporator (SWME) is being developed to perform the thermal control function for advanced spacesuits to take advantage of recent advances in micropore membrane technology in providing a robust heat-rejection device that is potentially less sensitive to contamination than is the sublimator. Principles of a sheet membrane SWME design were demonstrated using a prototypic test article that was tested in a vacuum chamber at JSC in July 1999. The Membrana Celgard X50-215 microporous hollow fiber (HoFi) membrane was selected after recent contamination tests as the most suitable candidate among commercial alternatives for HoFi SWME prototype development. A design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape, was developed into a full-scale prototype consisting 14,300 tube bundled into 30 stacks, each of which are formed into a chevron shape and separated by spacers and organized into three sectors of ten nested stacks. Vacuum chamber testing has been performed characterize heat rejection as a function of inlet water temperature and water vapor backpressure and to show contamination resistance to the constituents expected to be found in potable water produced by the distillation processes. Other tests showed the tolerance to freezing and suitability to reject heat in a Mars pressure environment.

Bue, Grant C.↗

Hollow Fiber Flight Prototype Spacesuit Water Membrane Evaporator Design and Testing

The spacesuit water membrane evaporator (SWME) is being developed to perform thermal control for advanced spacesuits and to take advantage of recent advances in micropore membrane technology. This results in a robust heat-rejection device that is potentially less sensitive to contamination than is the sublimator. The Membrana Celgard X50-215 microporous hollow-fiber (HoFi) membrane was selected after recent extensive testing as the most suitable candidate among commercial alternatives for continued SWME prototype development. The current design was based on a previous design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape. This was developed into a full-scale prototype consisting of 14,300 tube bundled into 30 stacks, each of which is formed into a chevron shape and separated by spacers and organized into three sectors of 10 nested stacks. The new design replaced metal components with plastic ones, and has a custom built flight like backpressure valve mounted on the side of the SWME housing to reduce backpressure when fully open. The spacers that provided separation of the chevron fiber stacks were eliminated. Vacuum chamber testing showed improved heat rejection as a function of inlet water temperature and water vapor backpressure compared with the previous design. Other tests pushed the limits of tolerance to freezing and showed suitability to reject heat in a Mars pressure environment with and without a sweep gas. Tolerance to contamination by constituents expected to be found in potable water produced by distillation processes was tested in a conventional way by allowing constituents to accumulate in the coolant as evaporation occurs. For this purpose, the SWME cartridge has endured an equivalent of 30 EVAs exposure and demonstrated minimal performance decline.

Bue, Grant↗

Hollow Fiber Space Water Membrane Evaporator Flight Prototype Design and Testing

The spacesuit water membrane evaporator (SWME) is being developed to perform thermal control for advanced spacesuits and to take advantage of recent advances in micropore membrane technology. This results in a robust heat-rejection device that is potentially less sensitive to contamination than is the sublimator. The current design was based on a previous design that grouped the fiber layers into stacks, which were separated by small spaces and packaged into a cylindrical shape. This was developed into a full-scale prototype consisting of 14,300 tube bundled into 30 stacks, each of which is formed into a chevron shape and separated by spacers and organized into three sectors of 10 nested stacks. The new design replaced metal components with plastic ones, eliminated the spacers, and has a custom built flight like backpressure valve mounted on the side of the SWME housing to reduce backpressure when fully open. A number of tests were performed in order to improve the strength of the polyurethane header that holds the fibers in place while the system is pressurized. Vacuum chamber testing showed similar heat rejection as a function of inlet water temperature and water vapor backpressure was similar to the previous design. Other tests pushed the limits of tolerance to freezing and showed suitability to reject heat in a Mars pressure environment with and without a sweep gas. Tolerance to contamination by constituents expected to be found in potable water produced by distillation processes was tested in a conventional way by allowing constituents to accumulate in the coolant as evaporation occurs. For this purpose, the SWME cartridge has endured an equivalent of 30 EVAs exposure and demonstrated acceptable performance decline.

Bue, Grant C.↗

Space Shuttle Upgrades: Long Life Alkaline Fuel Cell

NASA has utilized the alkaline fuel cell technology to provide electrical power for manned launch vehicles such as Gemini, Apollo, and the Space Shuttle. The current Shuttle alkaline fuel cells are procured from UTC Fuel Cells, a United Technologies Company. The alkaline fuel cells are very reliable but the operating life is limited to 2600 hours due to voltage degradation of the individual cells. The main limiting factor in the life of the cells is corrosion of the cell's fiberglass/epoxy frame by the aqueous potassium hydroxide electrolyte. To reduce operating costs, the orbiter program office approved the Long Life Alkaline Fuel Cell (LLAFC) program as a shuttle upgrade in 1999 to increase the operating life of the fuel cell powerplant to 5000 hours. The LLAFC program incorporates improving the cell by extending the length of the corrosion path, which reduces the cell frame corrosion. UTCFC performed analysis to understand the fundamental mechanisms that drive the cell frame corrosion. The analysis indicated that the corrosion path started along the bond line between the cathode and the cell frame. Analysis also showed that the oxygen available at the cathode, the catalyst on the electrode, and the electrode substrate all supported or intensified the corrosion. The new cell design essentially doubled the corrosion path to mitigate the problem. A 10-cell stack was tested for 5000 hours during the development phase of this program to verify improved cell performance. A complete 96-cell stack was then tested for 5000 hours during the full manned-space qualification phase of this program. Additional upgrades to the powerplant under this program are: replacing the aluminum body in the pressure regulator with stainless steel to reduce corrosion, improving stack insulator plate with improved resistance to stress failure and improved temperature capability, and replacing separator plate elastomer seals with a more durable material and improved seal retention.

Kerri McCurdy↗

Develop and test fuel cell powered on-site integrated total energy systems. Phase 3: Full-scale power plant development

The testing of two 25-cell stacks of the 13 inch x 23 inch cell size (about 4kW) was carried out for 7000 and 8400 hours, respectively. A 25kW stack containing 175 cells of the same size and based on the same technology was constructed and is on test. A third 4kW stack, which will contain 24 cells, will comprise several new technology features; these will be assesed for performance and durability in long-term testing.

Kaufman, A.↗

Enabling Long Term, Shelf‐Stable Perovskite Solar Cells: Alumina Barriers to Protect Perovskite Devices from Moisture and Oxygen

Current encapsulation architectures for thin-film metal halide perovskite do not adequately eliminate all ambient stressors. Here, we develop low transmission rate barrier layers using atomic layer deposited (ALD) aluminum oxide grown directly on the completed photovoltaic (PV) device stack to provide an additional seal, prior to full packaging. We investigate the effect of deposition temperature and oxidant chemistries on the barrier growth for protection of perovskite photovoltaic devices. We characterize the layers individually, then integrate into devices to detail the tradeoff between protection and deposition compatibility. To enhance compatibility and impermeability, we present an approach using water as the aluminum oxidant during nucleation and switching from water to ozone for the remainder of the growth. At 50 nm, the barrier results in a water vapor transmission rate (WVTR) of 4.5·10 −4 g/m 2 /day, and 1,000-hour device stability under 45°C with 85% relative humidity without further packaging. This barrier provides sufficient protection to enable minimal degradation of the perovskite solar cells while completely submerged in water for 140 minutes. Additionally, we characterize the oxygen transmission rate (OTR) to be 0.49 cm 3 /m 2 /day at 23°C and 0% relative humidity, which is 1.5 orders of magnitude improvement over the OTR of the current encapsulation.

14 SOLAR ENERGY↗

Deterministic fabrication of graphene hexagonal boron nitride moiré superlattices

The electronic properties of moiré heterostructures depend sensitively on the relative orientation between layers of the stack. For example, near-magic-angle twisted bilayer graphene (TBG) commonly shows superconductivity, yet a TBG sample with one of the graphene layers rotationally aligned to a hexagonal Boron Nitride (hBN) cladding layer provided experimental observation of orbital ferromagnetism. To create samples with aligned graphene/hBN, researchers often align edges of exfoliated flakes that appear straight in optical micrographs. However, graphene or hBN can cleave along either zig-zag or armchair lattice directions, introducing a 30° ambiguity in the relative orientation of two flakes. By characterizing the crystal lattice orientation of exfoliated flakes prior to stacking using Raman and second-harmonic generation for graphene and hBN, respectively, we unambiguously align monolayer graphene to hBN at a near-0°, not 30°, relative twist angle. We confirm this alignment by torsional force microscopy of the graphene/hBN moiré on an open-face stack, and then by cryogenic transport measurements, after full encapsulation with a second, nonaligned hBN layer. This work demonstrates a key step toward systematically exploring the effects of the relative twist angle between dissimilar materials within moiré heterostructures.

boron nitride↗

Scaling effects in the impact response of graphite-epoxy composite beams

In support of crashworthiness studies on composite airframes and substructure, an experimental and analytical study was conducted to characterize size effects in the large deflection response of scale model graphite-epoxy beams subjected to impact. Scale model beams of 1/2, 2/3, 3/4, 5/6, and full scale were constructed of four different laminate stacking sequences including unidirectional, angle ply, cross ply, and quasi-isotropic. The beam specimens were subjected to eccentric axial impact loads which were scaled to provide homologous beam responses. Comparisons of the load and strain time histories between the scale model beams and the prototype should verify the scale law and demonstrate the use of scale model testing for determining impact behavior of composite structures. The nonlinear structural analysis finite element program DYCAST (DYnamic Crash Analysis of STructures) was used to model the beam response. DYCAST analysis predictions of beam strain response are compared to experimental data and the results are presented.

Jackson, Karen E.↗

Results from a Si(Li) gamma ray detector stack for future Mars missions

We present Monte Carlo analysis and experimental data from a novel lithium-drifted silicon detector stack for gamma ray spectroscopy instrumentation in future Mars surface landers and other planetary missions. The Monte Carlo analysis shows full energy photopeaks even in the range of about 100 keV to 2 MeV where, in Si, Compton scattering dominates the absorption processes. Laboratory data is shown for an experimental detector stack of four planar Si(Li) devices, each 5 mm thick with an active area 2 cm in diameter. All the experimental data were collected with maximum temperature of the stack at 175 K. Background reduction is achieved by using the detector of the stack closest to the source in anticoincidence. We present a comparison of experimental data from the stack with the Monte Carlo model for Cs-137 (662 keV). Agreement is shown to be good, with a full energy photopeak clearly seen (FWHM about 10 keV). Experimental stack data is also shown for multiple peaks at 511 keV (Na-22) and 662 keV (Cs-137). The peaks are clearly resolved (FWHM 10 keV), and are compared with the results obtained using a 8 percent resolution, 3 in. x 3 in. NaI(TI) device (FWHM about 50 keV).

Hubbard, G. S.↗

Amorphization resistance of nanocrystalline 3C-SiC implanted with H2+ ions

Compared to single-crystal SiC, nanocrystalline SiC with high densities of stacking faults has been reported to be much more resistant to amorphization under self-ion and electron irradiations. This study examines H2+ ion irradiation-induced amorphization in nanocrystalline 3C-SiC with dense stacking faults using transmission electron microscopy. The results show that full amorphization at room temperature occurs at a comparable dose to that for its single-crystal SiC counterpart under the identical irradiation conditions. Both materials are amorphized as a result of local damage accumulation. The formation of the nucleation sites for amorphization is not appreciably affected by the presence of stacking faults and grain boundaries. The behavior may be attributed to the significant chemical effects that may completely immobilize the point defects in SiC at room temperature. The results suggest cautions be excised to use nanocrystalline SiC materials in high H irradiation environment at room temperature. Further studies of the H behavior at elevated temperatures are warranted.

Amorphization, ion irradiation, SiC↗

Develop and test fuel cell powered on site integrated total energy systems. Phase 3: Full-scale power plant development

The third in a series of 4kW stacks, consisting of 24 cells of the 13 inch x 23 inch cell size, has been on test for about 1600 hours. This stack is similar to the first two stacks, which ran 7000 and 8400 hours, respectively. The present stack incorporates technology improvements relating to the electrolyte-matrix, the current-collector assembly, and a reduction in the number of cooling plates. Performance is currently averaging about 0.64 per cell at 161 mA sq cm.

Kaufman, A.↗

Searching for the 3.5 keV Line in the Stacked Suzaku Observations of Galaxy Clusters

We perform a detailed study of the stacked Suzaku observations of 47 galaxy clusters, spanning a redshift range of 0.01-0.45, to search for the unidentified 3.5 keV line. This sample provides an independent test for the previously detected line. We detect a 2sigma-significant spectral feature at 3.5 keV in the spectrum of the full sample. When the sample is divided into two subsamples (cool-core and non-cool core clusters), the cool-core subsample shows no statistically significant positive residuals at the line energy. A very weak (approx. 2sigma confidence) spectral feature at 3.5 keV is permitted by the data from the non-cool-core clusters sample. The upper limit on a neutrino decay mixing angle of sin(sup 2)(2theta) = 6.1 x 10(exp -11) from the full Suzaku sample is consistent with the previous detections in the stacked XMM-Newton sample of galaxy clusters (which had a higher statistical sensitivity to faint lines), M31, and Galactic center, at a 90% confidence level. However, the constraint from the present sample, which does not include the Perseus cluster, is in tension with previously reported line flux observed in the core of the Perseus cluster with XMM-Newton and Suzaku.

dark matter↗

Data Projection of the High Temperature Electrolysis System in the Dynamic Energy Transport and Integration Laboratory using Dynamic System Scaling

For nuclear power to be flexible in a functioning Integrated Energy System (IES), excess produced heat must be stored or utilized during times of low power demand to ensure a load factor of 1 while load balancing. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility that is under development to emulate IES conditions on the engineering-scale, planned to conduct virtual real time operations with industry-scale facilities, and is currently testing thermal storage and high temperature electrolysis. As part of the study to develop a method to preprocess input signals or postprocess output signals between systems of different scales via Dynamical System Scaling (DSS), the current research is one of the continued efforts branching from the data projection activity conducted for the Thermal Energy Distribution System and currently engages the High Temperature Electrolysis (HTE) System in DETAIL. The HTE SOEC electrical, fluid, and thermal dynamics Figure of Merits (FOM) were identified, governing equations and closure relations were successfully scaled, and relations between FOM scaling ratios were determined. Setting the scaling objectives to reform existing data to project a data set that doubly accelerated the electrolysis process while preserving the produced amount of hydrogen was generated for the full transient. The calculated boundary conditions were inlet temperature, stack current, and inlet steam mass flow rate at 1470 K, 121.1 A, and 1.886 g/s, respectively. The research outcomes demonstrated an output signal postprocessing case accelerating the hydrogen production without changing geometry, number of cells, and partial pressures.

08 HYDROGEN↗

Pulsed power molten salt battery

It was concluded that carbon cathodes with chlorine work well. Lithium alloy chlorine at 450 C, 1 atm given high power capability, high energy density, DC + pulsing yields 600 pulses, no initial peak, and can go to red heat without burn-up. Electrochemical performance at the cell and cell stack level out under demanding test regime. Engineering and full prototype development for advancing this technology is warranted.

Argade, Shyam D.↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗