Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fuel stations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Providing Levelized Cost and Waiting Time Inputs for HDV Hydrogen Refueling Station Planning: A Case Study of U.S. I-75 Corridor

Widespread use of diesel fuels in freight transportation leads to greenhouse gas (GHG) emissions that play an important role in air pollution. The air pollution, as well as the energy crisis, drives the transition from diesel fuel to cleaner and more energy-efficient fuels such as hydrogen fuels. With such a transition, the strategic planning and optimization of supporting refueling infrastructure along the national highway for heavy-duty vehicles (HDVs) become a necessity. Cost and service level are two essential factors to be considered in hydrogen refueling station location and capacity optimization. The service level in this study is assessed by the delay (waiting time) at fueling stations as well as the fueling demand fulfilled. To this end, this study presents a methodology to provide waiting time (delay) and levelized hydrogen fuel cost inputs under different station configurations (number of dispensers and fill rates) for hydrogen refueling station planning. Determining the station configurations based on the trade-off between the two inputs is further discussed. Particularly, this study points out that the levelized cost and waiting time are affected by hourly demand patterns and estimates the two inputs under different peak hour fueling demand scenarios. The results suggest that, with the same daily demand, the cost, as well as the waiting time, increases obviously with the peak hour demand. In the case study, the cost grows at least 30% when the peak hour visit frequency of the daily total visits increases from 5% (evenly distributed pattern) to 10% (the most common pattern for existing diesel fueling stations along I-75). Accounting for this peak hour effect in hydrogen refueling station planning is recommended. Overall, the waiting time model and cost analysis provide key inputs for optimizing hydrogen refueling station location and configurations based on anticipated refueling demand patterns. The paper is the second in a series that aims to build a comprehensive modeling plan and optimize hydrogen refueling infrastructure along the Interstate 75 (I-75) corridor for HDVs.

Liu, Yuandong↗

Refueling Infrastructure Deployment in Low-Income and Non-Urban Communities

The U.S. National Blueprint for Transportation Decarbonization identifies the need to invest in infrastructure supporting low- and zero-emission vehicles, especially in low-income and overburdened communities, to eliminate nearly all greenhouse gas emissions from the transportation sector by 2050. The alternative fuel vehicle refueling property tax credit (26 U.S. Code § 30C) includes eligibility criteria intended to encourage investment in underserved communities based on the economic characteristics or urban character of the census tract in which the fueling infrastructure is installed. Eligible census tracts are those that qualify for the New Markets Tax Credit or that are not located within urban areas as defined by the U.S. Census Bureau. This study quantifies how many fueling-related amenities are currently located in census tracts that qualify and do not qualify for the 30C tax credit based on IRS Notice 2024-20. For existing electric vehicle charging stations, 51% of Level 2 and 60% of Direct Current Fast Charging public stations are located in eligible census tracts. 73% of natural gas, propane, and hydrogen fueling stations are in qualifying census tracts and 75% of biodiesel and renewable fuel stations are in qualifying census tracts. This compares with 73% of existing gas stations in eligible census tracts. For deploying the refueling infrastructure to satisfy future demand, this study shows that truck stops (94%), commercial truck stops (92%), and Federal Highway alternative fuel corridors (89%) are predominantly located in eligible locations. Additionally, significant percentages of the population (62%), light-duty vehicle registrations (64%), and medium- and heavy-duty vehicle registrations (68%) fall within eligible areas.

33 ADVANCED PROPULSION SYSTEMS↗

Study of Waste Generated by Retrieval of Fuel Debris at Fukushima Daiichi Nuclear Power Station - 20178

As a member of International Research Institute for Nuclear Decommissioning (IRID), we organized information on waste generated from the fuel debris retrieval, and considered containment, transport and storage processes. An important safety function to consider for these wastes is not only the handling of ordinary high-dose waste, but also the prevention of diffusion of fuel component contamination and the countermeasures against hydrogen gas generation. In order to satisfy these safety functions, we considered guideline for waste generated from the fuel debris retrieval, and proposed an example of handling process that includes generation of waste, container storage, on-site transfer and storage in a storage building. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DCFC + Hydrogen Station Design Optimization [Slides]

Both direct current fast charging (DCFC) and Hydrogen stations are working to create successful long-term business models; however, analyses for DCFC and hydrogen fueling infrastructure are almost always performed separately. This work provides a detailed exploration of the benefit of integrating DCFC and hydrogen stations to lower the total system cost from load balancing and equipment cost sharing. To achieve this we have adapted the REopt optimization framework to simultaneously optimize the design and operation of integrated DCFC and H2 fueling station. Results indicate that 1) combining hydrogen fueling and DCFC stations can significantly reduce lifetime costs compared to separated stations. 2) Co-location with additional site load reduces DCFC costs, however, integration of DCFC with hydrogen provides an even greater cost reduction. 3) Adding PV to combined stations further reduces the lifetime station cost. 4) Capital investments in station combination today can help reduce the cost of operating DCFC tomorrow and 5) product diversification acts as a hedge against variability and enables a more dynamic response to market changes.

08 HYDROGEN↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

ARC-100 Reactor Security-by-Design Summary 2025

This report applies the security-by-design methodology developed in a previous National Nuclear Security Administration–sponsored work to the ARC-100, a sodium-cooled fast reactor (SFR) being developed by ARC Clean Technology, Inc (ARC). The report contains no proprietary information specific to the ARC 100 reactor. The insights developed in this report are high-level, and generally applicable to other sodium fast reactor designs. The information presented here is the result of a qualitative safety-based analysis and would not inform any potential adversary beyond what would be found in a docketed safety analysis report. The scope of this present report covers ARC-100’s reactor core, used fuel storage, used fuel assembly wash station, cesium trap, sodium cold trap, noble gas decay tanks, used fuel dry storage facility, damaged fuel storage facility, and radioactive waste building. These systems are also compared to a generic SFR design assumed in the previous study. The security assessment results show changes in structures, systems, and components (SSCs) safety importance relative to the generic SFR SSCs. Several SSCs have higher importance rankings than others, and it is recommended that protection efforts are prioritized for these SSCs. Results from this work will furnish a technical justification for the feasibility of these solutions for the ARC reactor's design and, where applicable, identify any regulatory benefits conferred by the proactive design aspect within a risk management framework. This initiative will contribute to a more secure design of the ARC reactor and support its licensing process.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Maximizing Solar and Transportation Synergies

This report considers the technological and market pathways that will enable better use of photovoltaic (PV) electricity as fuel for future transportation demand. Most of the pathways identified will require collaborative research and development (R&D) efforts to improve the capabilities of multiple technologies, including PV, energy storage, vehicles, electrolyzers, electrofuels, and infrastructure. For plug-in electric vehicles (PEVs), technologies that enable wide-scale managed and coordinated charging are among the highest priorities for continued research, development, and deployment in the near term. Furthermore, managed and coordinated charging capabilities are foundational for future vehicle-to-grid (V2G) functionality in the long term. For hydrogen fuel cell electric vehicles (FCEVs), the use of PV electricity for electrolysis provides an opportunity to increase PV deployment. For rail, air, and maritime transportation, the feasibility of increased PV use varies in the near term; opportunities for synergies with solar include the electrification of rail, increased reliability from airport microgrids, and switching from heavy fuel oil to clean maritime electrofuels made from PV-based hydrogen. Over the longer term, battery swap stations for electric airplanes and the co-location of solar with hydrogen fueling stations at shipping ports may enable greater synergies between PV and transportation.

14 SOLAR ENERGY↗

I-80 Mid-America Clean Fuels Corridor: Deployment Plan Report

The I-80 Mid-America Clean Fuels Corridor, which spans I-80 from Fort Lee, New Jersey, to Council Bluffs, Iowa, was designated an Alternative Fuels Corridor (AFC) in Round 1 of the Alternative Fuels Corridor program administered by the U.S. Department of Transportation’s (DOT’s) Federal Highway Administration (FHWA). Originally called the “I-80 Mid-America Alternative Fuels Corridor,” it is now named the “I-80 Mid-America Clean Fuels Corridor.” As of Round 6 AFC designation, parts of the corridor have sufficient direct current fast charging (DCFC) stations to be designated Electric Vehicle (EV)-Ready and sufficient compressed natural gas (CNG) fueling stations to be designated CNG-Ready. However, much of the corridor’s approximately 1,240 miles (mi) are not yet EV- or CNG-Ready. This includes about 1,130 mi that are designated EV-Pending and 700 mi that are designated CNG-Pending. This report presents a plan to develop EV charging and CNG fueling infrastructure sufficient to convert the entire length of the corridor to EV-Ready and CNG-Ready. Specific sites are not identified for future infrastructure. Rather, priority exits are identified, and information, analysis, and additional steps are recommended to support further refinement of these locations, as well as additional outreach and deployment efforts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen and Electric Charging Infrastructure for Heavy-Duty Trucks: A Nationally Scalable Megaregion Assessment

Decarbonizing regional and long-haul freight is challenging due to the limitations of battery-electric commercial vehicles and infrastructure constraints. Hydrogen fuel cell medium- and heavy-duty vehicles (MHDVs) offer a viable alternative, aligning with the decarbonization goals of the Department of Energy and commercial entities. Historically, alternative fuels like compressed natural gas and liquefied propane gas have faced slow adoption due to barriers like infrastructure availability. To avoid similar issues, effective planning and deploying zero-emission hydrogen fueling infrastructure is crucial. This research develops deployment plans for affordable, accessible, and sustainable hydrogen refueling stations, supporting stakeholders in the decarbonized commercial vehicle freight system. It aims to benefit underserved and rural energy-stressed communities by improving air quality, reducing noise pollution, and enhancing energy resiliency. This research also provides a blueprint for replacing diesel in over-the-road Class 8 freight truck applications with hydrogen fueling solutions. The study focuses on the Texas Triangle Megaregion (I-45, I-35, and I-10), the I-10 corridor between San Antonio, TX, and Los Angeles, CA, and the I-5/CA-99 corridors between Los Angeles, CA, and San Francisco, CA. This area represents a significant portion of U.S. heavy-duty freight movement, carrying ~8.5% of the national freight volume. Using the OR-AGENT (Optimal Regional Architecture Generation for Efficient National Transport) modeling framework, the study conducts an advanced assessment of commercial vehicles, road and freight networks, and energy systems. The framework integrates data on freight mobility, traffic, weather, and energy pathways to deliver a region-specific, optimized vehicles powertrain architectures, infrastructure deployment solutions, operational logistics, and energy pathways. By considering all vehicle origin-destination pairs utilizing these corridors and all feasible fueling station location options, the framework's genetic algorithm identifies the minimum number and optimal locations of hydrogen refueling stations, ensuring no vehicle is stranded. It also determines fuel schedules and quantities at each station. A roadmap for station deployment based on multiple adoption trajectories ensures a strategic rollout of hydrogen refueling infrastructure.

Sujan, Vivek [ORNL] (ORCID:0000000269882342)↗

Connected and Learning Based Optimal Freight Management for Efficiency

The management of the future heterogenous fleet is a complex decision-making problem. The heterogenous fleet is emerging as decarbonization technologies are deployed by fleets toward lowering the freight operation emissions in Medium and Heavy-duty vehicles. Traditionally, in fleets characterized by a homogeneous Diesel Internal Combustion Engine (ICE) powertrain, the process of fleet planning and operational optimization unfolds sequentially without the necessity to account for powertrain and vehicle-specific characteristics during dispatch decisions. Fleets with trucks less than 5 years old tend to maintain stable vehicle efficiency with minimal operational reliability risks for fleet managers. However, the landscape changes with the incorporation of emerging powertrain technologies, which lack extensive operational data and service experiences. This includes technologies like hybrid, Electric, Fuel Cell, or alternative fuel ICE. Operational decisions for fleets featuring heterogeneous powertrain technologies and facing limited access to alternative fueling and charging stations become intricate, requiring careful consideration and optimization at each dispatch. The difference in efficiency characteristics of emerging technologies, their range limitations, and the restricted availability of charging/alternative fueling infrastructure, coupled with sensitivity to driving conditions (e.g., EV range reduction in low temperatures) and their impact on component aging (such as batteries), become pivotal factors influencing the reliable and efficient freight transportation. To make the path toward low emission freight transportation efficient and reliable, an AI-assisted fleet management software is developed in this project to help fleet managers in optimizing both adoption of emerging powertrain decarbonization, connected and automated technologies and also operating the fleet after such technologies are deployed as schematically. Freight transportation requirements are different depending on the cargos to be shipped, customer requirements and regions of operations. This further highlights the need for software and digital solutions to tailor deployment and operation of emerging powertrain, connectivity, and automation technologies toward the specific fleet operation requirements. The fleet management optimizer was also integrated with a model of the fleet to simulate the operation of the fleet over 1 year of the baseline fleet operation (250,000+ shipments) indicating the significance of day-to-day variations on emissions and energy consumption of a freight transportation fleet. The results demonstrate ≥20% improvement in freight efficiency in terms of WTW CO2 per ton-mile of cargo shipments while all fleet operation constraints are enforced, and the cost (CapEx and OpEx) is minimized.

33 ADVANCED PROPULSION SYSTEMS↗

Proposal for a Fusion Prototype Neutron Source at the Los Alamos Neutron Science Center

This study evaluates a target station at the Los Alamos Neutron Science Center dedicated to the mission of irradiating structural materials in an environment that is nearly prototypic of the radiation environment experienced by the first wall of a magnetically-confined fusion reactor burning D-T fuel. Such a station could be located in the existing Area A experimental hall and be driven by an 800-MeV, 1-MW proton beam delivered by the LANSCE accelerator. A neutronics assessment of a target concept shows it satisfies all of the key parameter guidelines stated in the Summary Report on the Fusion Prototypic Neutron Source Workshop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

H2Fills™ [SWR-19-67]

H2FillS: Hydrogen Filling Simulation The Hydrogen Filling Simulation (H2FillS) software is a thermodynamic model designed to track and report on the transient change in hydrogen temperature, pressure, and mass flow when filling a fuel cell electric vehicle (FCEV). H2FillS simulates gas flow from the hydrogen station to the FCEV storage system. Using empirical fueling data sets, the model has been validated over a range of fueling conditions to match common light-duty FCEV fill profiles. Overall, it provides significant benefits to the light-duty fueling market and fill knowledge gaps of the interaction between a hydrogen station and an FCEV. Capabilities Use the comprehensive H2FillS model to: Safely design and operate a hydrogen fueling station Support code refinement with readily available data Develop system and operational improvements to reduce capital or operating costs at hydrogen stations or on-board FCEVs. How It Works H2FillS uses a "drag-and-drop" graphical user interface to simulate station and vehicle systems with preset parameters for common hydrogen station components as default values. When needed, users can define their own parameters to create their own station or vehicle components. Download H2FillS in Two Steps Read the terms of the end user software license agreement. Register to download the software. There are two versions of the model: A full-station model starts the simulation at high-pressure ground storage, runs through a dispenser, and ends at a vehicle storage system. A partial-station model starts at the dispenser breakaway and consists solely of the dispenser components and the vehicle storage system. H2FillS will automatically output fill performance data from the vehicle by tracking pressure and temperature throughout the fill. Users can input their own fill profiles into the model to run a variety of simulations.

Peters, Michael↗

ARC-100 Reactor Security-by-Design Summary

This report applies the security-by-design methodology developed in a previous National Nuclear Security Administration–sponsored work to the Advanced Reactor Concepts 100 (ARC-100) sodium-cooled fast reactor (SFR) design. The report contains no proprietary information specific to the ARC 100 reactor. The insights developed in this report are high-level, and generally applicable to other sodium fast reactor designs. The information presented here is the result of a qualitative safety-based analysis and would not inform any potential adversary beyond what would be found in a docketed safety analysis report. The scope of this present report covers ARC-100’s reactor core, used fuel storage, and used fuel assembly wash station. These systems are also compared to a generic SFR design assumed in the previous study. The security assessment results show changes in structures, systems, and components (SSCs) safety importance relative to the generic SFR SSCs. However, the consequence assessment results are the similar to a previously assessed generic SFR. Several SSCs have higher importance rankings than others, and it is recommended that protection efforts are prioritized for these SSCs. This work will continue in the Fiscal Year 2025 for the remaining ARC-100 systems, including cesium trap, sodium cold trap, noble gas decay tanks (dewar bottles), and used fuel dry storage facility, to provide safety-and-security-by-design insights and recommendations on non-core systems. Results from this work will furnish a technical justification for the feasibility of these solutions for the ARC reactor's design and, where applicable, identify any regulatory benefits conferred by the proactive design aspect within a risk management framework. This initiative will contribute to a more secure design of the ARC reactor and support its licensing process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical predictions of cryogenic hydrogen vertical jets

Here, a comparison of Computational Fluid Dynamics (CFD) predictions with measurements is presented for cryo-compressed hydrogen vertical jets. The stagnation conditions of the experiments are characteristic of unintended leaks from pipe systems that connect cryogenic hydrogen storage tanks and could be encountered at a fuel cell refueling station. Jets with pressure up to 5 bar and temperatures just above the saturation liquid temperature were examined. Comparisons are made to the centerline mass fraction and temperature decay rates, the radial profiles of mass fraction and the contours of volume fraction. Two notional nozzle approaches are tested to model the under-expanded jet that was formed in the tests with pressures above 2 bar. In both approaches the mass and momentum balance from the throat to the notional nozzle are solved, while the temperature at the notional nozzle was assumed equal to the nozzle temperature in the first approach and was calculated by an energy balance in the second approach. The two approaches gave identical results. Satisfactory agreement with the measurements was found in terms of centerline mass fraction and temperature. However, for test with 3 and 4 bar release the concentration was overpredicted. Furthermore, a wider radial spread was observed in the predictions possibly revealing higher degree of diffusion using the k-ε turbulence model. An integral model for cryogenic jets was also developed and provided good results. Finally, a test simulation was performed with an ambient temperature jet and compared to the cold jet showing that warm jets decay faster than cold jets.

08 HYDROGEN↗

What Shapes Transportation Charging Infrastructure Availability? Evidence from Tennessee

This study examines how community, travel, and freight characteristics relate to public charging infrastructure availability across Tennessee ZIP codes. We link Alternative Fuels Data Center station locations with traffic, socioeconomic, demographic, commuting, and freight employment data to build a ZIP code-level dataset. Ordinary least squares regression captures variation in chargers per 10,000 residents (R2=0.311). Quantile regressions at the 25th, 50th, and 75th percentiles, with pseudo R2 values up to 0.099, show that the determinants of infrastructure availability differ across low-, medium-, and high-availability areas. Percent female, percent car commuters, average household size, and median age are negatively associated with charging availability across much of the distribution. Truck traffic is positively associated only in lower-availability ZIP codes, while vehicle miles traveled shifts from a negative association at the lower end of the distribution to a positive association at the upper end. The results provide insight into how public charging deployment aligns with community characteristics, mobility demand, and freight activity across Tennessee. Future work can distinguish charger types and power levels, incorporate land-use and temporal rollout patterns, and examine how charging infrastructure needs differ across urban and rural contexts.

Calderón, Oriana [University of Tennessee, Knoxvil↗

Hydrogen Infrastructure Modeling and Optimization

HyET, established in 2008, is a small business developing electro-chemical hydrogen compressors. HyET’s goals are for a low-cost, efficient, high-pressure compressor ready for market and installation into hydrogen infrastructure stations servicing mobile fuel cell applications. NLR has been working on hydrogen infrastructure research for over a decade and includes electrolyzer production via electrolysis, storage, compression, dispensing, safety, and performance validation. Accelerating technologies into the marketplace is one goal of NLR’s hydrogen research. Therefore, HyET and NLR have teamed up to provide one year of support for HyET’s modeling and small-scale experiments optimization efforts for HyET’s next-generation electro-chemical compressor.

08 HYDROGEN↗

Assessment of Heavy-Duty Fueling Methods and Components-Modeling and Analysis

The goal of the Assessment of Heavy-Duty Fueling Methods and Components project was to comprehensively assess heavy-duty (HD) fuel cell electric vehicle fueling protocols and their effects on techno-economic assessments (TEA) and total cost of ownership (TCO). The project leveraged and built upon ongoing international HD fueling protocols and fueling component development activities to deliver component performance assessments, modeling tools and methods evaluations, TEA of industry-selected protocol structures, and experimental validations of the strategies at the station scale. The effects of the protocols on the fueling times, station costs, and TCO were explored. Fueling time, which was influenced by temperature and protocol selection, had a large impact on the station cost due to component sizing and satisfying hourly demand. As the fleet size increased, the station cost was shown to exponentially decrease by achieving economies of scale. Technology year and fuel economy were the largest contributors to the TCO; however, the choice of fueling protocol had a minor impact on the TCO.

33 ADVANCED PROPULSION SYSTEMS↗

Federal Best Practices: Core Principles of Sustainable Fleet Management

This report helps agency fleet managers understand and implement optimal petroleum reduction strategies for fleet locations by evaluating the most appropriate combination of the four core principles of sustainable fleet management: right-sizing the fleet to agency mission by implementing a vehicle allocation methodology study; minimizing vehicle miles traveled; increasing fleet fuel efficiency by replacing inefficient vehicles with more fuel-efficient vehicles, maintaining vehicles, driving more efficiently, and avoiding excessive idling; and optimizing cost-effective alternative fuel use, including maximizing utilization of existing alternative fuel infrastructure, installing alternative fuel infrastructure where practical (including electric vehicle charging stations), and aligning deployment of alternative fuel vehicles with fueling infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗