Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Large Language Model for Determining Partial Tripping of Distributed Energy Resources

Knowing the status of individual distributed energy resources, i.e., being tripped or not, after a contingency can inform the development of an aggregated DER model. Here, this letter presents a large language model application to determine the partial tripping of distributed energy resources depending on the types, locations, and duration of faults in the transmission network. The large language model, or more specifically BERT-based approach can streamline the fault information into tokenized input, which not only reduces the complexity of the machine learning model but also demonstrates a robust performance with only limited data sets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methane Plume Emissions Associated With Puget Sound Faults in the Cascadia Forearc

Methane gas plumes have been discovered to issue from the seafloor in the Puget Sound estuary. These gas emission sites are co-located over traces of three major fault zones that fracture the entire forearc crust of the Cascadia Subduction Zone. Multibeam and single-beam sonar data from cruises conducted in 2011, 2018, 2019, 2020 and 2021 identified the acoustic signature of over 330 bubble plumes. Dissolved gas from the plumes combines to elevate seawater methane concentrations of the entire Puget Sound estuary. Fluid samples from adjacent terrestrial hot springs and deep-water wells surrounding the estuary contain a helium-3 isotope signature, indicating a deep fluid source located near the underlying Cascadia Subduction Zone. However, Puget Sound seawater emission sites lack chemical isotope signatures and elevated thermal anomalies expected from association with a deep plate-interface reservoir. The existence of vigorous marine methane plumes located in areas of thin sediment cover and above the traces of deeply-penetrating forearc fault zones – but still presenting no thermal or chemical anomalies that are found in many other similar forearc environments and remain an unresolved paradox.

54 ENVIRONMENTAL SCIENCES↗

ARETE: Accurate Error Assessment via Machine Learning-Guided Dynamic-Timing Analysis

Nanometer circuits are increasingly prone to timing errors, escalating the need for fault injection frameworks to accurately evaluate their impact on applications. Here in this paper, we propose ARETE, a novel cross-layer, fault-injection framework that combines dynamic-binary instrumentation with machine learning-guided dynamic-timing analysis. ARETE enables accurate fault-injection into any application by estimating the location of the injecting errors via dynamic-timing analysis. To accelerate fault-injection, we develop a novel, data-aware, machine learning-based mechanism that dynamically pre-selects the error-prone instructions and limits the application of the costly dynamic-timing analysis only to them. To evaluate ARETE's accuracy, our fully automated toolflow is configured to support fault-injection based on detailed post-layout gate-level simulations as well as via existing workload-agnostic error models. Our results for various workloads, including an autonomous-driving library, show that the location and time of injected errors performed by ARETE, is 89.9% consistent with fault-injection based on full gate-level simulation. On average, ARETE executes 84.6x faster than gate-level simulation and at a cost of 3.4% loss in the program output quality estimation. When compared to the existing statistical fault-injection tools that are based on workload-agnostic error models, ARETE improves the accuracy of fault-injection rate and output quality estimation by 143.9% and 40.4% on average, respectively.

97 MATHEMATICS AND COMPUTING↗

Monitoring Seismic Velocity Changes Across the San Jacinto Fault Using Train‐Generated Seismic Tremors

Abstract Microseismic noise has been used for seismic velocity monitoring. However, such signals are dominated by low‐frequency surface waves that are not ideal for detecting changes associated with small tectonic processes. Here we show that it is possible to extract stable, high‐frequency body waves using seismic tremors generated by freight trains. Such body waves allow us to focus on small velocity perturbations in the crust with high spatial resolution. We report on 10 years of seismic velocity temporal changes at the San Jacinto Fault. We observe and map a two‐month‐long episode of velocity changes with complex spatial distribution and interpret the velocity perturbation as produced by a previously undocumented slow‐slip event. We verify the hypothesis through numerical simulations and locate this event along a fault segment believed to be locked. Such a slow‐slip event stresses its surroundings and may trigger a major earthquake on a fault section approaching failure.

58 GEOSCIENCES↗

On Harmonizing Today’s Regulated Tariffs and Future Dynamic Electricity Pricing

A novel method for harmonizing the advantages of dynamic retail electricity pricing with the protections of regulated electricity tariffs is discussed and demonstrated. The method socializes and protects customers from long-term locational price variability that is unfair to those customers who are, by no fault of their own, served at congested locations on a distribution system. However, the method preserves short-term (e.g., diurnal) price variability that might induce helpful, mitigative responses from retail electricity customers. Because the method causes actual price recovery to track a customer class’s approved, regulated price recovery, the method may remove regulators’ objections to dynamic electricity pricing and thereby hasten adoption of market-based retail electricity pricing and transactive energy systems.

Consumer protection, Demand response, Market resea↗

Using discrete Bayesian networks for diagnosing and isolating cross-level faults in HVAC systems

Fault detection and diagnosis (FDD) technologies are critical to ensure satisfactory building performance, such as reducing energy wastes and negative impacts on occupant comfort and productivity. Existing FDD technologies mainly focus on component-level FDD solutions, which could lead to mis-diagnosis of cross-level faults in heating, ventilating, and air-conditioning (HVAC) systems. Cross-level faults are those faults that occur in one component or subsystem, but cause operational abnormalities in other components or subsystems, and result in a building level performance degradation. How to effectively diagnose the root cause of a cross-level fault is the focus of this study. Here, this paper presents a novel discrete Bayesian Network (DisBN)-based method for diagnosing cross-level faults in an HVAC system commonly used in commercial buildings. A two-level DisBN structure model is developed in this study. The parameters used in the DisBN model are obtained either from expert knowledge or through machine-learning strategies from normal system operation data. Meanwhile, the probability parameters are discretized to incorporate the uncertainties associated with typical expert knowledge. Thus, the developed DisBN method addresses the challenges many other BN based FDD methods face, i.e., the lack of fault data for BN parameter training. The developed DisBN represents causal relationships between a fault and its cross-level system impacts (i.e., fault symptoms or fault indicators) by considering how fault impacts propagate across different levels in an HVAC system. A weather and schedule information-based Pattern Matching (WPM) method is employed to automatically create WPM baseline data sets for each incoming real time snapshot data from the building systems. Consequently, BN inference and real-time diagnostics are achieved by comparing incoming snapshot data and the WPM baseline data set. The proposed method is evaluated using experimental fault data collected in a campus building. Fault diagnosis results demonstrate that the WPM-DisBN method is effective at locating the root causes of cross-level faults in an HVAC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding drivers of oil and gas well integrity issues in the greater wattenberg area of Colorado

Well integrity is critically important to maintain to minimize the environmental impacts of oil and gas development and other subsurface energy operations. The Wattenberg Field of Colorado—a top producing field with >40,000 wells—has one of the most robust publicly reported well integrity programs in the country. Here, in this study, we analyzed annular pressure and annular-fluid geochemical test results collected from Wattenberg wells through the end of 2019 to characterize the frequency and spatial variability of integrity issues in the field and understand their drivers. Estimated frequencies of integrity issues among tested wells were 8.2-17.1% between 1955 and 2019 and 6.1-11.4% in 2019 alone. The frequency of integrity issues was nearly four times greater in wells located above the Longmont Wrench Fault Zone. Potential drivers of integrity issues were identified using ensemble decision tree models trained with a broad set of relevant information. Models show that well integrity issues are spatially clustered on regional and sub-regional scales and suggest the relatively high frequency of integrity issues observed is likely attributed to geologic factors. These findings are valuable for regulatory agencies and operators seeking to inform well integrity monitoring, plugging, and emissions reduction efforts and design future subsurface energy projects.

03 NATURAL GAS↗

Shallow Crustal Structure and Site Response at Fort Greely, Alaska

Fort Greely, Alaska is located in proximity to numerous faults capable of generating large (MW > 6.5) and damaging earthquakes. However, little knowledge exists about the noise properties, shallow crustal structure and site response of the area. We address this by examining ambient noise conditions, Rayleigh wave group wavespeed dispersion, and site response measurements using new and existing seismic data from December 2020 – April 2021 for four sites along a north-south line—stations GREN, GRES, PS09, K24K operated by the Alaska Earthquake Center. We find that ambient noise levels are relatively high on base compared to other places in Central Alaska, especially above 1 Hz, while noise levels in the microseismic band are typical of the region. Short-period (0.5 – 2Hz) Rayleigh wave group wavespeeds appear to decrease with increasing sediment thickness and increase when going southward from GREN to K24K. The predominant site frequency related to sediment thickness is lowest beneath PS09 and highest beneath K24K. We use the group velocities and site response values to propose a rough north-south layered model for the region.

58 GEOSCIENCES↗

Seismic velocity modeling and earthquake relocations for the southern Nevada National Security Site (NNSS), with a focus on Rock Valley

The Rock Valley Direct Comparison (RV/DC) is the third phase of the Source Physics Experiment (SPE; Snelson et al., 2014), a project aimed at improving seismic discrimination between explosive sources and natural earthquakes. Phases I and II of SPE focused on studying the generation of shear waves in endmember geologies (granite and alluvium, respectively), while Phase III aims to detonate a chemical explosion co-located with the source region of the 1993 Rock Valley earthquake sequence, located in the Rock Valley Fault Zone (RVFZ), in the southern portion of the Nevada Test Site (now the Nevada National Security Site, or NNSS).

58 GEOSCIENCES↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Variable Continuous Bimaterial Interface in the San Jacinto Fault Zone Revealed by Dense Seismic Array Analysis of Fault Zone Head Waves

Key factors controlling earthquake ruptures include fault geometry, continuity, and seismic velocity structure around the fault. We present a novel tool that better informs deep bimaterial fault geometry embedded in distributed damage and seismicity, associated velocity contrasts across the fault, and their correlations with surface complexities. The method employs fault zone head and direct body waves and is applied to recordings from five spatiotemporally different seismic arrays along the complex San Jacinto fault zone (SJFZ) in southern California. We detect and distinguish these signals based on instantaneous phase coherence and relative energy in a cascading manner from one scale array to another. The analysis reveals a >70-km long continuous bimaterial interface within the SJFZ with several deep northeast dipping fault segments. The northern SJFZ, for instance, locates ~7 km northeast of its surface expression at 18-km depth. P-wave velocity contrasts range from near 0% to >15%, consistent with other bimaterial faults, and differ by a few % depending on fault-array azimuth, implying directional-dependent velocity contrasts. S-wave head waves and velocity contrasts are also imaged for the first time at the southern SJFZ, averaging to 2.9% in agreement with tomography results. The imaged geometry and continuity suggest the SJFZ initiated along remnant tectonic structures and translates to a rupture potential of M > 7.2, i.e., the sizes of its largest paleo-earthquakes. The P and S contrasts, and their ratios, have important implications for earthquake rupture speed, mode, directivity, and frictional heating along the SJFZ and other major faults globally.

58 GEOSCIENCES↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identifying geological structures through microseismic cluster and burst analyses complementing active seismic interpretation

At the Decatur carbon capture and storage site (IL, USA) CO 2 has been injected from 2011–2014 and from 2017 to present near the base of the Lower Mt. Simon Sandstone saline reservoir, resulting in microseismicity. Microseismicity is mainly located in the basement and distributed in distinct spatial clusters. The lack of significant impedance contrasts within the basement makes the interpretation of active-source seismic reflection data challenging, however, recent reprocessing allowed to resolve faults above and at the top of the basement. These faults generally do not coincide with the location of microseismic events and their continuation to the general depth of the seismic events cannot be assumed. This paper shows how the interpretation of the microseismicity can complement structural interpretations of active-source seismic reflection data. In particular, we analyze clusters and bursts (abrupt increases) of microseismicity, identify unresolved, smaller-scale weaknesses and extract statistical parameters. These parameters allow comparisons with the interpreted faults, and with fracture sets intercepted by boreholes. During injection at the Decatur site, the injection pressure was kept far below fracture pressure, nevertheless, seismic events were induced and spread far beyond the expected extent of the CO 2 plume. We argue that local stress transfers related to the CO 2 injection reactivated pre-existing fractures within the critically stressed basement. Finally, we conducted a slip tendency analysis for faults interpreted from active seismic, selected cluster, bursts and nodal planes from focal mechanisms to determine if the interpreted structures are optimally oriented with respect to the stress regime. Our results suggest that the orientation of fractures close to the injection well, generally shows slight deviations from the optimal orientation for slip. This might indicate either slight local deviations of the maximum horizontal stress azimuth from the average direction used in the analysis, or the lack of optimally oriented fractures at this location.

58 GEOSCIENCES↗

Graph-Learning-Assisted State and Event Tracking for Solar-Penetrated Power Grids with Heterogeneous Data Sources

Unlike transmission systems, distribution systems do not typically contain sufficient metering to enable real-time state estimation. The lack of sufficient real-time measurements prohibits accurate and timely monitoring of the state of distribution systems. As a result, control and optimal operation of distribution systems, especially those containing large numbers of renewable generation units are not possible without proper data and information about the current state of the system. The main motivation of this project is to address this shortcoming by developing an approach which provides “predicted” real-time measurements so that they can be used to execute a distribution system state estimator. Thus, the objective of the project is to make the distribution systems fully observable, such that the hosting capacity for solar generation can be accurately estimated, and unnecessary solar curtailments can be avoided. In order to accomplish this goal, the project investigated the use of a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams obtained from AMI meters, SCADA as well as PMU measurements and created synchronous measurement snapshots for the state estimator (SE); and developed a hybrid robust SE which provides not only accurate state estimates but also real-time feedback for the ML model refinement.

14 SOLAR ENERGY↗

Towards Automated/Semiautomated Extraction of Faults from Lidar Data

The Pajarito fault system is a complex zone of deformation and a seismically active region nestled within the Rio Grande rift in north-central New Mexico. Numerous laterally discontinuous faults and associated folds and fractures interact in a manner that has important implications for seismic hazards and risk mitigation. Previous efforts have established a foundation for the location of lineaments and structures in the Pajarito fault system; however, ensuring the completeness of the current lineament mapping is required for identifying areas for field validation, evaluating the potential for future seismic activity, and better understanding fault interaction. Assistance with this fault-mapping task via automated or semiautomated techniques as applied to lidar data over a large area of interest is highly desirable. A proof-of-concept processing flow which transforms lidar point-cloud data into a raster of surficial fault candidates is described and illustrated herein. We report these initial results hold great promise toward achieving our ultimate goal.

58 GEOSCIENCES↗

In-situ experiment reveals CO2 enriched fluid migration in faulted caprock

Abstract The sealing characteristics of the geological formation located above a CO 2 storage reservoir, the so-called caprock, are essential to ensure efficient geological carbon storage. If CO 2 were to leak through the caprock, temporal changes in fluid geochemistry can reveal fundamental information on migration mechanisms and induced fluid–rock interactions. Here, we present the results from a unique in-situ injection experiment, where CO 2 -enriched fluid was continuously injected in a faulted caprock analogue. Our results show that the CO 2 migration follows complex pathways within the fault structure. The joint analysis of noble gases, ion concentrations and carbon isotopes allow us to quantify mixing between injected CO 2 -enriched fluid and resident formation water and to describe the temporal evolution of water–rock interaction processes. The results presented here are a crucial complement to the geophysical monitoring at the fracture scale highlighting a unique migration of CO 2 in fault zones.

Science & Technology - Other Topics↗