At least 109 records · Page 6

Provider and User Perspectives on Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

The goal of this project was to understand, based on the primary reporting of AFDD providers and building owners, 1) the features currently available for RTU AFDD in the market today, 2) how RTU AFDD is used by building owners and managers, 3) how well RTU AFDD meets their needs, and 4) what barriers stand in the way of its broad industry adoption. To achieve this goal, 13 AFDD providers were asked about their products and seven building owners were questioned about their practical experience related to the automated detection, diagnosis, and communication of RTU faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Modeling of Unmanned Aerial Vehicle Electric Powertrain for Fault Detection and Diagnostics

This paper shows the application of hybrid physics-informed machine learning to a representative electric powertrain for unmanned aerial vehicles. The model is composed of physics-derived principles and empirical equations, as well as fully connected networks that are strategically placed within the model to substitute equations that are subject to large uncertainty. Polynomial fit driven by heuristics or empirical observations can be substituted by more flexible networks that can minimize the error between model predictions and observations without being restricted to a predefined functional form. This modeling strategy allows training of networks deep inside the model and unknown parameters in a single learning stage. It has already been applied to Li-ion batteries in the past, and in this work, we extend the applications to other components of an electric powertrain, namely electronic speed controller with pulse-width modulation, and brushless DC motor with connected propeller. Training and testing of the model is carried out using experimental data from Li-ion battery discharge and powertrain testing in a laboratory environment.

Physics-Informed Machine Learning↗

A simplified dynamic model of the T700 turboshaft engine

A simplified open-loop dynamic model of the T700 turboshaft engine, valid within the normal operating range of the engine, is developed. This model is obtained by linking linear state space models obtained at different engine operating points. Each linear model is developed from a detailed nonlinear engine simulation using a multivariable system identification and realization method. The simplified model may be used with a model-based real time diagnostic scheme for fault detection and diagnostics, as well as for open loop engine dynamics studies and closed loop control analysis utilizing a user generated control law.

Duyar, Ahmet↗

Identification of the open loop dynamics of the T700 turboshaft engine

A simplified model of the T700 turboshaft engine open loop dynamics valid within the normal operating range of the engine is developed. This model is obtained by linking the linearized point models obtained at five different operating conditions of the engine. The simplified model may be used with a model-based real time diagnostic scheme for fault detection and diagnostics, as well as for open loop engine dynamics studies and closed loop control analysis utilizing a user generated control law.

Duyar, Ahmet↗

A fault injection experiment using the AIRLAB Diagnostic Emulation Facility

The preparation for, conduct of, and results of a simulation based fault injection experiment conducted using the AIRLAB Diagnostic Emulation facilities is described. An objective of this experiment was to determine the effectiveness of the diagnostic self-test sequences used to uncover latent faults in a logic network providing the key fault tolerance features for a flight control computer. Another objective was to develop methods, tools, and techniques for conducting the experiment. More than 1600 faults were injected into a logic gate level model of the Data Communicator/Interstage (C/I). For each fault injected, diagnostic self-test sequences consisting of over 300 test vectors were supplied to the C/I model as inputs. For each test vector within a test sequence, the outputs from the C/I model were compared to the outputs of a fault free C/I. If the outputs differed, the fault was considered detectable for the given test vector. These results were then analyzed to determine the effectiveness of some test sequences. The results established coverage of selt-test diagnostics, identified areas in the C/I logic where the tests did not locate faults, and suggest fault latency reduction opportunities.

Baker, Robert↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ares I-X Ground Diagnostic Prototype

The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.

Schwabacher, Mark A.↗

What We Learned From Analyzing 18 Million Rows of Commercial Buildings’ HVAC Fault Data

To achieve ambitious decarbonization goals it is critical that buildings operate to their full potential. Commercial HVAC systems, however, experience a wide range of operational faults, adversely affecting energy consumption, occupant comfort, and maintenance costs. Analytical tools such as fault detection & diagnostics (FDD) software identify and help diagnose these types of sensing, mechanical, or control-related faults. While significant energy savings has been documented for FDD, along with limited-scale studies on technical capabilities, there is a lack of empirical data on faults being reported by FDD tools. With FDD deployment accelerating significantly over the past decade there is an opportunity to gather and analyze data on commercial HVAC operational problems at an unprecedented scale. Such data could address many questions such as: [a] What faults are most commonly reported?; and [b] How does fault reporting vary by time of year and other possible drivers? A recent study into FDD fault reporting amassed the largest U.S. dataset of commercial HVAC air-side fault records, drawn from multi-year monitoring across over 60,000 pieces of HVAC equipment. The results of this study provide granular data on fault reporting for over 90 unique fault types. In this paper we provide an overview of the research process and highlight key findings and lessons learned. This study presents an extraordinary level of detail on FDD fault reporting characteristics across many climate zones and building types. Armed with these new insights, commercial building industry stakeholders can make better informed decisions when designing, configuring, and operating commercial HVAC systems.

Crowe, Eliot↗

Hypothetical Scenario Generator for Fault-Tolerant Diagnosis

The Hypothetical Scenario Generator for Fault-tolerant Diagnostics (HSG) is an algorithm being developed in conjunction with other components of artificial- intelligence systems for automated diagnosis and prognosis of faults in spacecraft, aircraft, and other complex engineering systems. By incorporating prognostic capabilities along with advanced diagnostic capabilities, these developments hold promise to increase the safety and affordability of the affected engineering systems by making it possible to obtain timely and accurate information on the statuses of the systems and predicting impending failures well in advance. The HSG is a specific instance of a hypothetical- scenario generator that implements an innovative approach for performing diagnostic reasoning when data are missing. The special purpose served by the HSG is to (1) look for all possible ways in which the present state of the engineering system can be mapped with respect to a given model and (2) generate a prioritized set of future possible states and the scenarios of which they are parts.

James, Mark↗

A Framework to Debug Diagnostic Matrices

Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

Model-based↗

Fault Management Metrics

This paper describes the theory and considerations in the application of metrics to measure the effectiveness of fault management. Fault management refers here to the operational aspect of system health management, and as such is considered as a meta-control loop that operates to preserve or maximize the system's ability to achieve its goals in the face of current or prospective failure. As a suite of control loops, the metrics to estimate and measure the effectiveness of fault management are similar to those of classical control loops in being divided into two major classes: state estimation, and state control. State estimation metrics can be classified into lower-level subdivisions for detection coverage, detection effectiveness, fault isolation and fault identification (diagnostics), and failure prognosis. State control metrics can be classified into response determination effectiveness and response effectiveness. These metrics are applied to each and every fault management control loop in the system, for each failure to which they apply, and probabilistically summed to determine the effectiveness of these fault management control loops to preserve the relevant system goals that they are intended to protect.

Johnson, Stephen B.↗

A bi-level data-driven framework for fault-detection and diagnosis of HVAC systems

Long-term operation of heating, ventilation, and air conditioning (HVAC) systems will eventually lead to a range of HVAC system failures, resulting in excessive energy consumption and maintenance costs. Here, to avoid HVAC malfunctioning, fault detection diagnostic (FDD) is utilized as a common practice. Machine learning methods have lately received considerable interest for FDD analysis of HVAC systems due to their high detection accuracy. Meanwhile, HVAC malfunctions are regarded as rare occurrences, hence normal operating data samples are much more accessible than data samples in faulty and malfunctioning conditions. The dominating frequency of normal operation in HVAC datasets has also led to heavily biased classification algorithms within the literature. Moreover, the focus of previous literature has been on increasing the accuracy of the models which leads to a high number of false positives (misleading alarms) in the system. In order to enhance the performance of diagnostic procedures and fill the mentioned gaps, this study proposes a novel data-driven framework. A bi-level machine learning framework is developed for diagnosing faults in air handling units (AHUs) and rooftop units (RTUs) based on principal component analysis (PCA), time series anomaly detection, and random forest (RF). It is shown that PCA can reduce the dataset dimension with one principal component accounting for 95% of data variance. Also, the random forest could classify the faults with 89% precision for single-zone AHU, 85% precision for RTU, and 79% for multi-zone AHU. By proposing this framework, three persistent challenges are addressed: (I) minimizing false positives; (II) accounting for data imbalance; and (III) normal condition monitoring of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Fault Isolation for Health Monitoring of Electric Aircraft Propulsion by Embedding Failure Mode and Effect Analysis into Bayesian Networks

This paper describes a fault isolation approach for electric powertrains of unmanned aerial vehicles. The approach leverages the combination of failure mode and effect analysis (FMEA) and Bayesian networks, thus introducing depend-ability structures into a diagnostic framework. Faults and failure events from the FMEA are mapped within a Bayesian network, where network edges replicate the links embedded within FMEAs. This framework helps the fault isolation process by identifying the probability of occurrence of specific faults or root causes given evidence observed through sensor signals. The framework is applied to an electric power-train system of a small, rotary-wing unmanned aerial vehicle, demonstrating how a Bayesian network enhanced by FMEA helps disambiguate between root causes of incipient failures, which would otherwise be considered as equally probable.

Fault Isolation↗