Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “evaporation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Psychrometric Analysis for New NuMI Evaporator Weather Station

Tritium (H-3) is a weakly radioactive isotope of hydrogen and is a byproduct of accelerator operations at Fermi National Accelerator Laboratory (Fermilab). The Neutrinos at the Main Injector (NuMI) target produced tritiated condensate exhausted via the MI-65 building evaporators. Re-condensation of tritium evaporate was observed on the MI-65 rooftop, on nearby buildings, and on the surrounding grounds due to inefficiency of the existing evaporator system. A new evaporator system is being designed to eliminate re-condensation, and psychrometric data (temperature, humidity and dew point) plays a vital role in determining the location of a weather station to control the new evaporator system.

Alvarado-Anderson, Chase↗

Review of Dew Point Evaporative Cooling Technology for Air Conditioning Applications

Indirect evaporative cooling has the potential to significantly improve the natural environment. It follows from a significant reduction in electricity consumption in the hot period, and hence lower operating costs for cooling systems. This paper presents the current state of knowledge and research directions on dew point indirect evaporative cooling. It was found that researchers focus on the development of dew point indirect evaporative coolers (DPIEC) by improving its design, geometry, water distribution, and new porous materials implementation. To evaluate the performance of new types of DPIEC, different methods are used by the scientists. Finally, optimized devices are studied in terms of their performance in different systems, like hybrid and desiccant systems, considering different climate conditions. Potential directions of development of evaporative technologies were indicated, such as increasing the coefficient of performance of solid desiccant evaporative cooling systems, developing novel geometry, and efficient water distribution, including development of porous materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaporation in space manufacturing

'Normal evaporation' equations for predicting the compositional changes with time and temperature have been developed and correlated with actual experimental data. An evaporative congruent temperature is defined and used to explain, predict, or plan space experiments on anomalous constitutional melting (on cooling) or solidification (on heating). Uneven evaporation causes reactive jetting forces capable of initiating new convection currents, nongravitational accelerations, surface vibrations, or other disturbances. Applications of evaporation to space manufacturing are described concerning evaporative purification, surface cooling, specimen selection, particles splitting, freezing data interpretation, material loss and dimensional control, and surface contamination or compositional changes.

Li, C. H.↗

Evaporative winds in X-ray binaries

Evaporation of gas from the surface of HZ Her by Her X-1 and its implications regarding the mass transfer process are examined further. The powerful soft X-ray flux results in an evaporation rate greater than previous estimates. The evaporative flow is shown to be subsonic at first, with the result that the capture of evaporated gas by Her X-1 may be efficient, and the self-excited wind mechanism is possible. A criterion for stabilization of mass transfer by stellar wind mass loss is derived. Possible mechanisms for the long-period variability of HZ Her are discussed. Evaporative winds are also estimated for Sco X-1 and Cyg X-2 spectra.

Basko, M. M.↗

Evaporation of ice in planetary atmospheres: Ice-covered rivers on Mars

The evaporation rate of water ice on the surface of a planet with an atmosphere involves an equilibrium between solar heating and radiative and evaporative cooling of the ice layer. The thickness of the ice is governed principally by the solar flux which penetrates the ice layer and then is conducted back to the surface. Evaporation from the surface is governed by wind and free convection. In the absence of wind, eddy diffusion is caused by the lower density of water vapor in comparison to the density of the Martian atmosphere. For mean martian insolations, the evaporation rate above the ice is approximately 10 to the minus 8th power gm/sq cm/s. Evaporation rates are calculated for a wide range of frictional velocities, atmospheric pressures, and insolations and it seems clear that at least some subset of observed Martian channels may have formed as ice-chocked rivers. Typical equilibrium thicknesses of such ice covers are approximately 10m to 30 m; typical surface temperatures are 210 to 235 K.

Wallace, D.↗

Direct evidence for chromospheric evaporation in a well-observed compact flare

Observations of the solar flare of May 7, 1980 using several Solar Maximum Mission instruments are presented as an investigation of the phenomenon of chromospheric evaporation. The total amount of plasma at temperatures greater than 2 x 10 to the 6th K were determined from the X-ray data, and the amount of plasma that was evaporated from the chromosphere was determined from the H-alpha data. The H-alpha profiles indicate that for the flare as a whole, at the time of peak soft X-ray emission measure, the number of atoms evaporated from the chromosphere was 7 x 10 to the 37th. The soft X-ray emission measure of 1 x 10 to the 49th/cu cm, coupled with the flare volume estimate of 10 to the 26th cu cm, indicates that there were 3 x 10 to the 37th electrons in the soft X-ray plasma with temperatures greater than 2 x 10 to the 6th K. These results indicate that enough material had been evaporated from the chromosphere to account for the X-ray plasma. Taken together, the H-alpha, soft X-ray, and hard X-ray images indicate that chromospheric evaporation is driven both by flare-accelerated electrons during the impulsive phase and by conduction during the thermal phase.

Canfield, R. C.↗

Multi-leg heat pipe evaporator

A multileg heat pipe evaporator facilitates the use and application of a monogroove heat pipe by providing an evaporation section which is compact in area and structurally more compatible with certain heat exchangers or heat input apparatus. The evaporation section of a monogroove heat pipe is formed by a series of parallel legs having a liquid and a vapor channel and a communicating capillary slot therebetween. The liquid and vapor channels and interconnecting capillary slots of the evaporating section are connected to the condensing section of the heat pipe by a manifold connecting liquid and vapor channels of the parallel evaporation section legs with the corresponding liquid and vapor channels of the condensing section.

Alario, J. P.↗

Relating evaporative fraction to remotely sensed data at the FIFE site

Evaporative fractions at surface flux stations on the Konza Prairie are investigated by means of heat-flux estimation, evaporative fractions, and other remotely sensed parameters. Radiometric surface-temperature measurements are used to calculate sensible heat, and evaporative fraction is characterized by comparing systematic differences and consistencies at 21 stations. The evaporative fractions are related to soil and vegetation data collected concurrently with attention given to specific correlations. Little variation is found in the evaporative fraction during the day for the four periods studied, although the most significant change corresponded with the lowest values of soil moisture, leaf-area indices, and simple ratio. Uncertainties in air/surface temperature differences and in small wind speeds affect the reliability of estimates of the surface fluxes.

Gurney, R. J.↗

The dynamics of dense and dilute clusters of drops evaporating in large, coherent vortices

The behavior of evaporating clusters of drops embedded into large, coherent vortices is described using a formulation which is valid for both dense and dilute clusters. Drops and gas interact both dynamically and thermodynamically. Dynamic coupling occurs through a force on the drops due to drag resulting from a slip velocity between the two phases. The net interaction force on the gas with drops is due to a source thrust from evaporation plus drag on each drop. The drag coefficient accounts for blowing from the drop surface. Thermodynamic coupling is a result of drop heating and evaporation. Limitations due to drop proximity on heating and evaporation are taken into account. The vortical motion of the drops in the cluster results in the formation of a core region devoid of drops at the center of the vortex, and a shell region containing the drops and surrounding the inner core. Results are presented showing the dependence of the evaporation time, the final to initial volume ratio and the final to initial shell thickness ratio upon the initial air/fuel mass ratio and as a function of the initial tangential velocities, upon the initial Stokes number, initial drop radius and initial outer cluster radius. Differences in behavior between and control parameters of dense and dilute clusters are pointed out by these new results. It is found that for dense clusters the final to initial volume ratio and final to initial shell thickness scale with the initial Stokes number, a new result which must be validated experimentally.

Bellan, J.↗

Application of self-preservation in the diurnal evolution of the surface energy budget to determine daily evaporation

Evaporation from natural land surfaces often exhibits a strong variation during the course of a day, mostly in response to the daily variation of radiative energy input at the surface. This makes it difficult to derive the total daily evaporation, when only one or a few instantaneous estimates of evaporation are available. It is often possible to resolve this difficulty by assuming self-preservation in the diurnal evolution of the surface energy budget. Thus if the relative partition of total incoming energy flux among the different components remains the same, the ratio of latent heat flux and any other flux component can be taken as constant through the day. This concept of constant flux ratios is tested by means of data obtained during the First ISLSCP Field Experiment; the instantaneous evaporation values were calculated by means of the atmospheric boundary layer bulk similarity approach with radiosonde profiles and radiative surface temperatures. Good results were obtained for evaporative flux ratios with available energy flux, with net radiation, and with incoming shortwave radiation.

Brutsaert, Wilfried↗

An Experimental Study of Pressure Oscillation in a Capillary Pumped Loop with Multiple Evaporators and Condensers

The heat transport capability of a capillary pumped loop (CPL) is limited by the pressure drop that its evaporator wick can sustain. The pressure drop in a CPL is not constant even under seemingly steady operation, but rather exhibits an oscillatory behavior. A hydrodynamic theory based on a mass-spring-dashpot model was previously developed to predict the pressure oscillation in a CPL with a single evaporator and a single condenser. The theory states that the pressure oscillation is a function of physical dimensions of the CPL components and operating conditions. Experimental data agreed very well with theoretical predictions. The hydrodynamic stability theory has recently been extended to predict the pressure oscillations in CPLs with multiple evaporators and multiple condensers. Concurrently, an experimental study was conducted to verify the theory and to investigate the effects of various parameters on the pressure oscillation. Four evaporators with different wick properties were tested using a test loop containing two condenser plates. The test loop allowed the four evaporators to be tested in a single-pump, two-pump or four-pump configuration, and the two condenser plates to be plumbed either in parallel or in series. Test conditions included varying the power input, the reservoir set point temperature, the condenser sink temperature, and the flow resistance between the reservoir and the loop. Experimental results agreed well with theoretical predictions.

Ku, Jen-Tung↗

Evaporative Cooling Membrane Device

An evaporative cooling membrane device is disclosed having a flat or pleated plate housing with an enclosed bottom and an exposed top that is covered with at least one sheet of hydrophobic porous material having a thin thickness so as to serve as a membrane. The hydrophobic porous material has pores with predetermined dimensions so as to resist any fluid in its liquid state from passing therethrough but to allow passage of the fluid in its vapor state, thereby, causing the evaporation of the fluid and the cooling of the remaining fluid. The fluid has a predetermined flow rate. The evaporative cooling membrane device has a channel which is sized in cooperation with the predetermined flow rate of the fluid so as to produce laminar flow therein. The evaporative cooling membrane device provides for the convenient control of the evaporation rates of the circulating fluid by adjusting the flow rates of the laminar flowing fluid.

Lomax, Curtis↗

Testing of a Loop Heat Pipe with Two Evaporators and Two Condensers

Most existing Loop Heat Pipes (LHPs) consist of one single evaporator and one single condenser. LHPs with multiple evaporators will be very desirable for cooling multiple heat sources or a heat source with large thermal footprints. Extending the LHP technology to include multiple evaporators and multiple condensers faces some challenges, including the interaction between individual compensation chambers, operating temperature stability, and adaptability to rapid power and sink temperature transients. This paper describe extensive testing of an LHP with two evaporators and two condensers. Tests performed include start-up, power cycle, sink temperature cycle, reservoir temperature cycle, and capillary limit. Test results showed that the loop could operate successfully under various heat load and sink conditions. The loop operating temperature is a function of the total heat load, the heat load distribution between the two evaporators, and temperatures of the two condenser sinks. Under most conditions, only one reservoir contained two-phase fluid and the other reservoir was completely liquid filled. Moreover, control of the loop operating temperature could shift from one reservoir to the other as the test condition changed.

Ku, Jentung↗

Active Control of the Operating Temperature in a Loop Heat Pipe with Two Evaporators and Two Condensers

The operating temperature of a loop heat pipe (LHP) with multiple evaporators is a function of the total heat load, heat load distribution among evaporators, condenser temperature and ambient temperature. Because of the many variables involved, the operating temperature also showed more hystereses than an LHP with a single evaporator. Tight temperature control can be achieved by controlling its compensation chamber (CC) temperatures at the desired set point. This paper describes a test program on active control of the operating temperature in an LHP with two evaporators and two condensers. Temperature control was achieved by heating one or both CC's. Tests performed included start-up, power cycle, sink temperature cycle, CC temperature cycle, and capillary limit. Test results show that, regardless one or two CC's were heated to the set point temperature, one of CC's was always flooded with liquid. The loop could operate successfully at the desired set point temperature under most conditions, including some fast transients. At low heat loads, however, the CC temperature could suddenly increase above the set point temperature, possibly due to a sudden change of the vapor content inside the evaporator core.

Ku, Jentung↗

Theoretical and Experimental Investigation of the Stability of an Evaporating Constrained Vapor Bubble

The major accomplishments of the experimental portion of the research were documented in Ling Zheng's doctoral dissertation. Using Pentane, he obtained a considerable amount of data on the stability and heat transfer characteristics of an evaporating meniscus. The important points are that experimental equipment to obtain data on the stability and heat transfer characteristics of an evaporating meniscus were built and successfully operated. The data and subsequent analyses were accepted by the Journal of Heat Transfer for publication in 2004 [PU4]. The work was continued by a new graduate student using HFE-7000 [PU3] and then Pentane at lower heat fluxes. The Pentane results are being analyzed for publication. The experimental techniques are currently being used in our other NASA Grant. The oscillation of the contact line observed in the experiments involves evaporation (retraction part) and spreading. Since both processes occur with finite contact angles, it is important to derive a precise equation of the intermolecular forces (disjoining pressure) valid for non-zero contact angles. This theoretical derivation was accepted for publication by Journal of Fluid Mechanics [PU5]. The evaporation process near the contact line is complicated, and an idealized micro heat pipe has been proposed to help in elucidating the detailed evaporation process [manuscripts in preparation].

Wayner, P. C., Jr.↗

Marangoni Convection and Deviations from Maxwells' Evaporation Model

We investigate the convective dynamics of evaporating pools of volatile liquids using an ultra-sensitive thermal imaging camera. During evaporation, there are significant convective flows inside the liquid due to Marangoni forces. We find that Marangoni convection during evaporation can dramatically affect the evaporation rates of volatile liquids. A simple heat balance model connects the convective velocities and temperature gradients to the evaporation rates.

Segre, P. N.↗

Testing of the Multi-Fluid Evaporator Engineering Development Unit

Hamilton Sundstrand is under contract with the NASA Johnson Space Center to develop a scalable, evaporative heat rejection system called the Multi-Fluid Evaporator (MFE). It is being designed to support the Orion Crew Module and to support future Constellation missions. The MFE would be used from Earth sea level conditions to the vacuum of space. The current Shuttle configuration utilizes an ammonia boiler and flash evaporator system to achieve cooling at all altitudes. The MFE system combines both functions into a single compact package with significant weight reduction and improved freeze-up protection. The heat exchanger core is designed so that radial flow of the evaporant provides increasing surface area to keep the back pressure low. The multiple layer construction of the core allows for efficient scale up to the desired heat rejection rate. The full scale MFE prototype will be constructed with four core sections that, combined with a novel control scheme, manage the risk of freezing the heat exchanger cores. A sub-scale MFE engineering development unit (EDU) has been built, and is identical to one of the four sections of a full scale prototype. The EDU has completed testing at Hamilton Sundstrand. The overall test objective was to determine the thermal performance of the EDU. The first set of tests simulated how each of the four sections of the prototype would perform by varying the chamber pressure, evaporant flow rate, coolant flow rate and coolant temperature. A second set of tests was conducted with an outlet steam header in place to verify that the outlet steam orifices prevent freeze-up in the core while also allowing the desired thermal turn-down ratio. This paper discusses the EDU tests and results.

Quinn, Gregory↗

Importance of Rain Evaporation and Continental Convection in the Tropical Water Cycle

Atmospheric moisture cycling is an important aspect of the Earth's climate system, yet the processes determining atmospheric humidity are poorly understood. For example, direct evaporation of rain contributes significantly to the heat and moisture budgets of clouds, but few observations of these processes are available. Similarly, the relative contributions to atmospheric moisture over land from local evaporation and humidity from oceanic sources are uncertain. Lighter isotopes of water vapour preferentially evaporate whereas heavier isotopes preferentially condense and the isotopic composition of ocean water is known. Here we use this information combined with global measurements of the isotopic composition of tropospheric water vapour from the Tropospheric Emission Spectrometer (TES) aboard the Aura spacecraft, to investigate aspects of the atmospheric hydrological cycle that are not well constrained by observations of precipitation or atmospheric vapour content. Our measurements of the isotopic composition of water vapour near tropical clouds suggest that rainfall evaporation contributes significantly to lower troposphere humidity, with typically 20% and up to 50% of rainfall evaporating near convective clouds. Over the tropical continents the isotopic signature of tropospheric water vapour differs significantly from that of precipitation, suggesting that convection of vapour from both oceanic sources and evapotranspiration are the dominant moisture sources. Our measurements allow an assessment of the intensity of the present hydrological cycle and will help identify any future changes as they occur.

Worden, John↗