SEARCH · Engineering Papers
Results for “error localization”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Hierarchical Multi-Agent Based Anomaly Detection for Wide-Area Protection in Smart Grid
Future smart grid capabilities provide assurance to expand the advanced information and communication technologies to evolve into densely interconnected cyber physical system. Remedial Action Scheme (RAS), widely used for wide-area protection, relies on the interconnected networks and data sharing devices, which are exposed to the multitude of vulnerabilities. This paper presents our proposed approach to developing multi-agent based RAS scheme against the system-aware stealthy cyber-attacks. Specifically, we propose the two-level hierarchical architecture which consists of distributed local RAS controllers (RAScs) as local agents, operating at different zones/ areas, which are constantly monitored by an overseer, the central agent. The local controllers receive local and randomly changing outside zonal measurements and cyclically forwards to the overseer. The overseer identifies the corrupted controller using the anomaly detection algorithm which processes the measurements coming from the local controllers, compute measurement errors using local and outside zonal measurements, perform validation checks, and finally detect anomalies based on the two-step verification. Next, as a proof of concept, we have implemented and validated the proposed methodology in cyber physical environment at Iowa State’s PowerCyber testbed. We have also implemented the coordinated attack vectors which involve corrupting the local controller and later performing stealthy attacks on the system’s generator. We have evaluated its performance during the online testing in terms of detection rate and Iatency. The experimental results show that it is efficient in detecting different classes of attacks, including ramp and pulse attacks.
Error Analysis on Numerical Integration Algorithms in a Hypoelasticity Framework
This report determines local truncation errors for common stress integration algorithms used in explicit finite element codes with hypoelastic material models. The hypoelastic integration algorithms in question utilize an operator splitting procedure in a rotation neutralized configuration, where the stress response is determined from de- coupling the total deformation into rotational and strain dependent components. This document analyzes the error in evolving the stress given a one-step time increment Δt and compares the errors associated with both the rotational and strain components of the operator splitting method. A slight modification to a traditional algorithm is proposed and studied, where the rate of deformation is appropriately rotated from the midstep configuration at t n+1/2 to the end step configuration at t n+1 before the constitutive evaluation. The proposed modification either completely eliminates the error associated with the rotation rate or is of the same order of magnitude as the original algorithm for the three test cases considered in this report. These cases consist of an unaxial stretch with a constant true strain rate with a rigid body rotation, an uniaxial stretch with a constant engineering strain rate with a rigid body rotation, and a simple shear deformation. All three cases are compared to a closed form solution, and in almost every test case the alternative algorithm yields the most accurate one-step local truncation error.
Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position
Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived from a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.
Error containment for enabling local checkpoint and recovery
Various embodiments include a parallel processing computer system that detects memory errors as a memory client loads data from memory and disables the memory client from storing data to memory, thereby reducing the likelihood that the memory error propagates to other memory clients. The memory client initiates a stall sequence, while other memory clients continue to execute instructions and the memory continues to service memory load and store operations. When a memory error is detected, a specific bit pattern is stored in conjunction with the data associated with the memory error. When the data is copied from one memory to another memory, the specific bit pattern is also copied, in order to identify the data as having a memory error.
Stochastic goal-oriented error estimation with memory
We propose a stochastic dual-weighted error estimator for the viscous shallow-water equation with boundaries. For this purpose, previous work on memory-less stochastic dual-weighted error estimation is extended by incorporating memory effects. The memory is introduced by describing the local truncation error as a sum of time-correlated random variables. The random variables itself represent the temporal fluctuations in local truncation errors and are estimated from high-resolution information at near-initial times. The resulting error estimator is evaluated experimentally in two classical ocean-type experiments, the Munk gyre and the flow around an island. In these experiments, the stochastic process is adapted locally to the respective dynamical flow regime. Our stochastic dual-weighted error estimator is shown to provide meaningful error bounds for a range of physically relevant goals. We prove, as well as show numerically, that our approach can be interpreted as a linearized stochastic-physics ensemble.
Interior energy error estimates for the weak Galerkin finite element method
Consider the Poisson equation in a polytopal domain ΩRC d (d=2,3) as the model problem. In this paper, we study interior energy error estimates for the weak Galerkin finite element approximation to elliptic boundary value problems. In particular, we show that the interior error in the energy norm is bounded by three components: the best local approximation error, the error in negative norms, and the trace error on the element boundaries. This implies that the interior convergence rate can be polluted by solution singularities on the domain boundary, even when the solution is smooth in the interior region. Numerical results are reported to support the theoretical findings. Lastly, to the best of our knowledge, this is the first local energy error analysis that applies to general meshes consisting of polytopal elements and hanging nodes.
Nonlinear registration of serial coronary CT angiography (CCTA) for assessment of changes in atherosclerotic plaque
Purpose: Coronary CT angiography (CCTA) is a high-resolution three-dimensional imaging technique for the evaluation of coronary arteries in suspected or confirmed coronary artery disease (CAD). Coregistration of serial CCTA scans would allow precise superimposition of images obtained at two different points in time, which could aid in recognition of subtle changes and precise monitoring of coronary plaque progression or regression. To this end, the authors aimed at developing a fully automatic nonlinear volume coregistration for longitudinal CCTA scan pairs. Methods: The algorithm combines global displacement and local deformation using nonlinear volume coregistration with a volume-preserving constraint. Histogram matching of intensities between two serial scans is performed prior to nonlinear coregistration with dense nonparametric local deformation in which sum of squared differences is used as a similarity measure. The approximate segmentation of coronary arteries obtained from commercially available software provides initial anatomical landmarks for the coregistration algorithm that help localize and emphasize the structure of interest. To avoid possible bias caused by incorrect segmentation, the authors convolve the Gaussian kernel with the segmented binary coronary tree mask and define an extended weighted region of interest. A multiresolution approach is employed to represent coarse-to-fine details of both volumes and the energy function is optimized using a gradient descent method. The authors applied the algorithm in ten paired CCTA datasets (20 scans in total) obtained within 10.7{+-}5.7 months from each other on a dual source CT scanner to monitor progression of CAD. Results: Serial CCTA coregistration was successful in 9/10 cases as visually confirmed. The global displacement and local deformation of target registration error obtained from four anatomical landmarks were 2.22{+-}1.15 and 1.56{+-}0.74 mm, respectively, and the inverse consistency error of local deformation was 0.14{+-}0.06 mm. The observer variability between two expert observers was 1.31{+-}0.91 mm. Conclusions: The proposed coregistration algorithm demonstrates potential to accurately register serial CCTA scans, which may allow direct comparison of calcified and noncalcified atherosclerotic plaque changes between the two scans.
Sci—Thur AM: YIS - 10: Use of the Microsoft Kinect for applications of patient surface data to radiotherapy
Current techniques to acquire patient surface data are often very expensive and lack flexibility. In this study, the use of the Microsoft Kinect to reliably acquire 3D scans of patient surface is investigated. A design is presented to make the system easily applicable to the clinic. Potential applications of the device to radiotherapy are also presented. Scan reproducibility was tested by repeatedly scanning an anthropomorphic phantom. Scan accuracy was tested by comparing Kinect scans to the surface extracted from a CT dataset of a Rando® anthropomorphic phantom, which was considered as the true reference surface. Average signed distances of 0.12 ± 2.34 mm and 0.13 ± 2.04 mm were obtained between the compared surfaces for reproducibility and accuracy respectively. This is conclusive, since it indicates that the variations observed come largely from noise distributed around an average distance close to 0 mm. Moreover, the range of the noise is small enough for the system to reliably capture a patient's surface. A system was also designed using two Kinects used together to acquire 3D surfaces in a quick and stable way that is applicable to the clinic. Finally, applications of the device to radiotherapy are demonstrated. Its use to detect local positioning errors is presented, where small local variations difficult to see with the naked eye are clearly visible. The system was also used to predict collisions using gantry and patient scans and thus ensure the safety of unconventional trajectories.
Extended Forward Sensitivity Analysis for Uncertainty Quantification
Verification and validation (V&V) are playing more important roles to quantify uncertainties and realize high fidelity simulations in engineering system analyses, such as transients happened in a complex nuclear reactor system. Traditional V&V in the reactor system analysis focused more on the validation part or did not differentiate verification and validation. The traditional approach to uncertainty quantification is based on a 'black box' approach. The simulation tool is treated as an unknown signal generator, a distribution of inputs according to assumed probability density functions is sent in and the distribution of the outputs is measured and correlated back to the original input distribution. The 'black box' method mixes numerical errors with all other uncertainties. It is also not efficient to perform sensitivity analysis. Contrary to the 'black box' method, a more efficient sensitivity approach can take advantage of intimate knowledge of the simulation code. In these types of approaches equations for the propagation of uncertainty are constructed and the sensitivities are directly solved for as variables in the simulation. This paper presents the forward sensitivity analysis as a method to help uncertainty qualification. By including time step and potentially spatial step as special sensitivity parameters, the forward sensitivity method is extended as one method to quantify numerical errors. Note that by integrating local truncation errors over the whole system through the forward sensitivity analysis process, the generated time step and spatial step sensitivity information reflect global numerical errors. The discretization errors can be systematically compared against uncertainties due to other physical parameters. This extension makes the forward sensitivity method a much more powerful tool to help uncertainty qualification. By knowing the relative sensitivity of time and space steps with other interested physical parameters, the simulation is allowed to run at optimized time and space steps without affecting the confidence of the physical parameter sensitivity results. The time and space steps forward sensitivity analysis method can also replace the traditional time step and grid convergence study with much less computational cost. Several well defined benchmark problems with manufactured solutions are utilized to demonstrate the extended forward sensitivity analysis method. All the physical solutions, parameter sensitivity solutions, even the time step sensitivity in one case, have analytical forms, which allows the verification to be performed in the strictest sense.
Extended Forward Sensitivity Analysis for Uncertainty Quantification
This paper presents the extended forward sensitivity analysis as a method to help uncertainty qualification. By including time step and potentially spatial step as special sensitivity parameters, the forward sensitivity method is extended as one method to quantify numerical errors. Note that by integrating local truncation errors over the whole system through the forward sensitivity analysis process, the generated time step and spatial step sensitivity information reflect global numerical errors. The discretization errors can be systematically compared against uncertainties due to other physical parameters. This extension makes the forward sensitivity method a much more powerful tool to help uncertainty qualification. By knowing the relative sensitivity of time and space steps with other interested physical parameters, the simulation is allowed to run at optimized time and space steps without affecting the confidence of the physical parameter sensitivity results. The time and space steps forward sensitivity analysis method can also replace the traditional time step and grid convergence study with much less computational cost. Two well-defined benchmark problems with manufactured solutions are utilized to demonstrate the method.
11-th order of accuracy for numerical solution of 3-D Poisson equation with irregular interfaces on unfitted Cartesian meshes
For the first time the optimal local truncation error method (OLTEM) with 125-point stencils and unfitted Cartesian meshes has been developed in the general 3-D case for the Poisson equation for heterogeneous materials with smooth irregular interfaces. The 125-point stencils equations that are similar to those for quadratic finite elements are used for OLTEM. The interface conditions for OLTEM are imposed as constraints at a small number of interface points and do not require the introduction of additional unknowns, i.e., the sparse structure of global discrete equations of OLTEM is the same for homogeneous and heterogeneous materials. The stencils coefficients of OLTEM are calculated by the minimization of the local truncation error of the stencil equations. These derivations include the use of the Poisson equation for the relationship between the different spatial derivatives. Such a procedure provides the maximum possible accuracy of the discrete equations of OLTEM. In contrast to known numerical techniques with quadratic elements and third order of accuracy on conforming and unfitted meshes, OLTEM with the 125-point stencils provides 11-th order of accuracy, i.e., an extremely large increase in accuracy by 8 orders for similar stencils. The numerical results show that OLTEM yields much more accurate results than high-order finite elements with much wider stencils. The increased numerical accuracy of OLTEM leads to an extremely large increase in computational efficiency. Additionally, a new post-processing procedure with the 125-point stencil has been developed for the calculation of the spatial derivatives of the primary function. The post-processing procedure includes the minimization of the local truncation error and the use of the Poisson equation. It is demonstrated that the use of the partial differential equation (PDE) for the 125-point stencils improves the accuracy of the spatial derivatives by 6 orders compared to post-processing without the use of PDE as in existing numerical techniques. At an accuracy of 0.1% for the spatial derivatives, OLTEM reduces the number of degrees of freedom by 900 - 4∙10 6 times compared to quadratic finite elements. The developed post-processing procedure can be easily extended to unstructured meshes and can be independently used with existing post-processing techniques (e.g., with finite elements).
A data-driven framework for error estimation and mesh-model optimization in system-level thermal-hydraulic simulation
We report over the past decades, several computer codes have been developed for simulation and analysis of thermal-hydraulics and system response in nuclear reactors under operating, abnormal transient, and accident conditions. However, simulation errors and uncertainties still inevitably exist even while these codes have been extensively assessed and used. In this work, a data-driven framework (Optimal Mesh/Model Information System, OMIS) is formulated and demonstrated to estimate simulation error and suggest optimal selection of computational mesh size (i.e., nodalization) and constitutive correlations (e.g., wall functions and turbulence models) for low-fidelity, coarse-mesh thermal-hydraulic simulation, in order to achieve accuracy comparable to that of high-fidelity simulation. Using results from high-fidelity simulations and experimental data with many fast-running low-fidelity simulations, an error database is built and used to train a machine learning model that can determine the relationship between local simulation error and local physical features. This machine learning model is then used to generate insight and help correct low-fidelity simulations for similar physical conditions. The OMIS framework is designed as a modularized six-step procedure and accomplished with state-of-the-art methods and algorithms. A mixed-convection case study was performed to illustrate the entire framework.
A Description of the Full Particle Orbit Following SPIRAL Code for Simulating Fast-ion Experiments in Tokamaks
The numerical methods used in the full particle-orbit following SPIRAL code are described and a number of physics studies performed with the code are presented to illustrate its capabilities. The SPIRAL code is a test-particle code and is a powerful numerical tool to interpret and plan fast-ion experiments in Tokamaks. Gyro-orbit effects are important for fast ions in low-field machines such as NSTX and to a lesser extent in DIII-D. A number of physics studies are interlaced between the description of the code to illustrate its capabilities. Results on heat loads generated by a localized error-field on the DIII-D wall are compared to measurements. The enhanced Triton losses caused by the same localized error-field are calculated and compared to measured neutron signals. MHD activity such as tearing modes and Toroidicity-induced Alfven Eigenmodes (TAEs) have a profound effect on the fast-ion content of Tokamak plasmas and SPIRAL can calculate the effects of MHD activity on the confined and lost fast-ion population as illustrated for a burst of TAE activity in NSTX. The interaction between Ion Cyclotron Range of Frequency (ICRF) heating and fast ions depends solely on the gyro-motion of the fast ions and is captured exactly in the SPIRAL code. A calculation of ICRF absorption on beam ions in ITER is presented. The effects of high harmonic fast wave heating on the beam-ion slowing-down distribution in NSTX is also studied.
Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer
Purpose: The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comprised of a helical plane of diodes in a volumetric phantom. Methods: We describe the methods and derivations of new corrections that account for repetition rate dependence, intrinsic relative sensitivity per diode, field size dependence based on the dynamic field size determination, and positional correction. Required and described is an accurate ''virtual inclinometer'' algorithm. The system allows for calibrating the array directly against an ion chamber signal collected with high angular resolution. These enhancements are quantitatively validated using several strategies including ion chamber measurements taken using a ''blank'' plastic shell mimicking the actual phantom, and comparison to high resolution dose calculations for a variety of fields: static, simple arcs, and VMAT. A number of sophisticated treatment planning algorithms were benchmarked against ion chamber measurements for their ability to handle a large air cavity in the phantom. Results: Each calibration correction is quantified and presented vs its independent variable(s). The virtual inclinometer is validated by direct comparison to the gantry angle vs time data from machine log files. The effects of the calibration are quantified and improvements are seen in the dose agreement with the ion chamber reference measurements and with the TPS calculations. These improved agreements are a result of removing prior limitations and assumptions in the calibration methodology. Average gamma analysis passing rates for VMAT plans based on the AAPM TG-119 report are 98.4 and 93.3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.
10-th order of accuracy for numerical solution of 3-D elasticity equations for heterogeneous materials on unfitted Cartesian meshes
We have developed the Optimal Local Truncation Error Method (OLTEM) with 10-th order of accuracy on unfitted Cartesian meshes for a system of 3-D elasticity equations with smooth irregular interfaces. 5 x 5 x 5 = 125-point stencils (similar to those for quadratic finite elements) for elastic heterogeneous materials are used for OLTEM. There are no unknowns at the interface points between different materials; the structure of the global discrete equations is the same for homogeneous and heterogeneous materials. The calculation of unknown stencil coefficients is based on the minimization of the local truncation error of the stencil equations and yields the optimal 10-th order of accuracy for OLTEM on unfitted Cartesian meshes, i.e., the increase by 7 orders in accuracy compared to quadratic finite elements on conformal meshes. A new post-processing procedure provides the 9-th order of accuracy for stresses in the 3-D case. Similar to basic computations it uses OLTEM with the 125-point stencils, the interface conditions and the elasticity equations. It was shown that the use of the elasticity equations for post-processing improves the accuracy of 0.1% stresses by 6 orders compared to post-processing without the use of PDEs. At an accuracy of for stresses, OLTEM with the new post-processing procedure reduces the number of degrees of freedom by 360 - 8000 times compared to quadratic finite elements with similar stencils. OLTEM with the 125-point stencils yields even more accurate results than high-order finite elements with much wider stencils. OLTEM provides accurate numerical results for compressible and nearly incompressible materials.
MeV Au Ion Irradiation in Silicon and Nanocrystalline Zirconia Film Deposited on Silicon Substrate
Nanocrystalline zirconia (ZrO2) film with thickness of 305 nm deposited on a silicon substrate was irradiated with 2 MeV Au ions to different fluences at different temperatures. The implanted ion profiles were measured by time-of-flight secondary ion mass spectrometry (ToF-SIMS) and simulated using the stopping and range of ions inmatter (SRIM) code, respectively. The experimental results show that a large fraction of the incident Au ions penetrates through the ZrO2 film and are deposited into the Si substrate. At the interface of ZrO2 and Si, a sudden decrease of Au concentration is observed due to the much larger scattering cross section of Au in ZrO2 than in Si. The depth profile of the Au ions is measured in both the ZrO2 films and the Si substrates, and the results show that the Au distribution profiles do not exhibit a dependence on irradiation temperature. The local Au concentration increases proportionally with the irradiation fluence, suggesting that no thermal or irradiation-induced redistribution of the implanted Au ions. However, the Au concentration in the ZrO2 films, as determined by SIMS, is considerably lower than that predicted by the SRIM results, and the penetration depth from the SIMS measurements is much deeper than that from the SRIM predictions. These observations can be explained by an overestimation of the electronic stopping power, used in the SRIM program, for heavy incident ions in light targets. Over-estimation of the heavy-ion electronic stopping power may lead to errors in local dose calculation and underestimation of the projected range of slow heavy ions in targets that contain light elements. A quick estimate based on a reduced target density may be used to compensate the overestimation of the electronic stopping power in the SRIM program to provide better ion profile prediction.