Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Soft Syndrome Decoding of Quantum LDPC Codes for Joint Correction of Data and Syndrome Errors

Quantum errors are primarily detected and corrected using the measurement of syndrome information which itself is an unreliable step in practical error correction implementations. Typically, such faulty or noisy syndrome measurements are modeled as a binary measurement outcome flipped with some probability. However, the measured syndrome is in fact a discretized value of the continuous voltage or current values obtained in the physical implementation of the syndrome extraction. In this paper, we use this "soft" or analog information without the conventional discretization step to benefit the iterative decoders for decoding quantum low-density parity-check (QLDPC) codes. Syndrome-based iterative belief propagation (BP) decoders are modified to utilize the syndrome-soft information to successfully correct both data and syndrome errors simultaneously, without repeated measurements. We demonstrate the advantages of extracting the soft information from the syndrome in our improved decoders, not only in terms of comparison of thresholds and logical error rates for quasi-cyclic lifted-product QLDPC code families, but also for faster convergence of iterative decoders. In particular, the new BP decoder with noisy syndrome performs as good as the standard BP decoder under ideal syndrome.

97 MATHEMATICS AND COMPUTING↗

Exploring the Early Lightning Notification of an Electric Field Mill at the Savannah River Site

At the Savannah River Site (SRS), employees receive automated broadcast notification about lightning only after three strikes have already occurred near the site boundary. To increase employee safety, it is preferential to give employees lead time before lightning strikes occur. We compared measurements from an on-site electric field mill to lightning detection data from the National Lightning Detection Network and the Geostationary Lightning Mapper. Using a difference threshold, we determined that the electric field mill provided a lead time greater than 6 minutes for 95% of lightning events from 2009-2020, with an average lead time of 56 minutes. Detection of events were limited to a 7-mile radius around the field mill. We also identified that the field mill threshold generated many false detections not clearly identified. False detections and detections from only precipitation can be reduced by using a second threshold without creating too many missed detections (Type II errors). The two thresholds used together provide the best information about rapidly changing electric fields and aid in advanced detection necessary to improve the lightning warning system used at SRS.

42 ENGINEERING↗

Leveraging Qubit Loss Detection in Fault-Tolerant Quantum Algorithms

Qubit loss errors constitute a dominant source of noise in many quantum hardware systems, particularly in neutral-atom quantum computers. We develop a theoretical framework to effectively detect and correct loss errors in logical algorithms and leverage such loss information in decoding. Considering general quantum error correction codes and logical circuits, we introduce a delayed-erasure decoder for experimentally motivated error models which leverages information from delayed loss detection to accurately correct loss errors, even when the precise moment of the error is unknown. Using this decoder, we identify strategies for detecting and correcting loss errors based on the logical circuit structure. For deep circuits prior to logical measurement, we explore methods to integrate loss detection into syndrome extraction with minimal overhead, identifying optimal strategies depending on the qubit loss fraction in the noise and hardware capabilities. In contrast, we find that many key algorithmic subroutines involve frequent gate teleportation, shortening the circuit depth before logical measurement and naturally replacing qubits with no additional experimental overhead. We simulate this setting using a toy model algorithm for small-angle synthesis and find a significant performance improvement as the loss fraction increases. These results provide a path forward for advancing large-scale fault-tolerant quantum computation in systems with loss error detection.

atoms↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Detecting macroevolutionary genotype–phenotype associations using error-corrected rates of protein convergence

On macroevolutionary timescales, extensive mutations and phylogenetic uncertainty mask the signals of genotype–phenotype associations underlying convergent evolution. To overcome this problem, we extended the widely used framework of non-synonymous to synonymous substitution rate ratios and developed the novel metric ω C , which measures the error-corrected convergence rate of protein evolution. While ω C distinguishes natural selection from genetic noise and phylogenetic errors in simulation and real examples, its accuracy allows an exploratory genome-wide search of adaptive molecular convergence without phenotypic hypothesis or candidate genes. Using gene expression data, we explored over 20 million branch combinations in vertebrate genes and identified the joint convergence of expression patterns and protein sequences with amino acid substitutions in functionally important sites, providing hypotheses on undiscovered phenotypes. We further extended our method with a heuristic algorithm to detect highly repetitive convergence among computationally non-trivial higher-order phylogenetic combinations. Our approach allows bidirectional searches for genotype–phenotype associations, even in lineages that diverged for hundreds of millions of years.

59 BASIC BIOLOGICAL SCIENCES↗

Study of Classifiers for U-235 Source Signatures Using Gamma Spectral Measurements

Signatures associated with low-level U-235 sources are studied from a classification analytics perspective, using NaI gamma-ray spectral measurements from detectors located at various distances from the source. Data sets collected at a shielded facility are utilized, wherein the source is introduced via a conduit into a formation of 21 NaI detectors deployed over 6 x 6 meters area in a formation of two concentric circles and one spiral. The activity levels in the spectral regions associated with potential U-235 signatures are estimated as counts at 1 second intervals, and are used as features to train classifiers for detecting the presence of the source. Eight different classifiers are trained and tested using the background and source measurements collected over multiple experimental runs. As expected, the classifier performance improved overall as measurements from the detectors closer to source are used, but also revealed unexpectedly low performance by two detectors that are identically produced and configured as others. Six of eight classifiers have an overall comparable performance, for example, three of them achieved zero training error and 99% detection at 4% false alarm rate for a detector located 1.3 meters away from the source. Also, larger training sets led to improved classification performance across all classifiers, and interestingly, the classifiers with the minimum training error did not necessarily achieve the highest classification performance on test data.

Rao, Nageswara↗

Local Truncation Error-Informed Code Verification

The method of manufactured solutions (MMS) has become increasingly popular in conducting code verification studies on predictive codes, such as nuclear power system codes and computational fluid dynamic codes. The reason for the popularity of this approach is that it can be used when an analytical solution is not available. Using MMS, code developers are able to verify that their code is free of coding errors that impact the observed order of accuracy. While MMS is still an excellent tool for code verification, it does not identify coding errors that are of the same order as the numerical method. This paper presents a method that combines MMS with modified equation analysis (MEA), which calculates the local truncation error (LTE) to identify coding error up to and including the order of the numerical method. This method is referred to as modified equation analysis methd of manufactured solutions (MEAMMS). MEAMMS is then applied to a custom-built code, which solves the shallow water equations, to test the performance of the code verification method. MEAMMS is able to detect all coding errors that impact the implementation of the numerical scheme. To show how MEAMMS is different than MMS, they are both applied to the same first-order numerical method test problem with a first-order coding error. When there are first-order coding errors, only MEAMMS is able to identify them. Finally, this shows that MEAMMS is able to identify a larger set of coding errors while still being able to identify the coding errors MMS is able to identify.

42 ENGINEERING↗

Comparative Analysis of Imaging and Measurements of Micrometer-Scale Fracture Aperture Fields Within a Heterogeneous Rock Using PET and X-ray CT

Knowledge of the spatial distribution of fracture apertures is essential for reliable characterization of flow and transport processes in fractured systems and for better understanding of physicochemical matrix–fracture interactions. Here, we propose and test two image-based methods, thereby extending the current experimental capabilities to characterize aperture size distribution in structurally heterogeneous geologic porous media noninvasively. The first approach utilizes an inversion method based on the dataset acquired from positron emission tomography (PET) and the second approach considers an extension of the classic missing attenuation technique that relies on clinical X-ray computed tomography (X-ray CT). Independent sets of imaging experiments are conducted on a fractured basalt core with heterogeneous matrix properties and aperture distributions to compare the two methodologies. A repeat of each experiment is conducted to verify the proposed workflows. The performance of these two imaging techniques is systematically evaluated through the analysis of signal-to-noise ratio, minimum fracture size detectability, and measurement errors. While both approaches provide a reliable estimation of fracture aperture distributions, PET yields a signal-to-noise ratio that is substantially higher than the corresponding X-ray CT measurements. Furthermore, uncertainties of the aperture values for PET are considerably lower ($\bar {\sigma}_{\text {d}} = 15\%$) compared to those obtained from X-ray CT ($\bar {\sigma}_{\text {d}} = 29\%$), allowing for the detection of minimum aperture sizes of 20 $\mu$m with 70% confidence level. Finally, these approaches provide key experimental tools for better understanding dynamic hydromechanical fracture properties in geologic systems.

58 GEOSCIENCES↗

Solving k –SAT problems with generalized quantum measurement

We generalize the projection–based quantum measurement–driven k –SAT algorithm of Benjamin, Zhao, and Fitzsimons to arbitrary strength quantum measurements, including the limit of continuous monitoring. In doing so, we clarify that this algorithm is a particular case of the measurement–driven quantum control strategy elsewhere referred to as “Zeno dragging”. We argue that the algorithm is most efficient with finite time and measurement resources in the continuum limit, where measurements have an infinitesimal strength and duration. Moreover, for solvable k -SAT problems, the dynamics generated by the algorithm converge deterministically towards target dynamics in the long–time (Zeno) limit, implying that the algorithm can successfully operate autonomously via Lindblad dissipation, without detection. We subsequently study both the conditional and unconditional dynamics of the algorithm implemented via generalized measurements, quantifying the advantages of detection for heralding errors. These strategies are investigated first in a computationally–trivial 2-qubit 2-SAT problem to build intuition, and then we consider the scaling of the algorithm on 3-SAT problems encoded with 4–10 qubits. We numerically investigate the scaling of 3-SAT with respect to algorithmic runtime and find that the optimized time to solution scales with qubit number n as λ n , where λ is slightly larger than $\sqrt{2}$ for unconditional dynamics and less than $\sqrt{2}$ for conditional dynamics. We assess the implications for using this analog measurement–driven approach to quantum computing in practice.

quantum information↗

Low-overhead transversal fault tolerance for universal quantum computation

Fast, reliable logical operations are essential for realizing useful quantum computers. By redundantly encoding logical qubits into many physical qubits and using syndrome measurements to detect and correct errors, we can achieve low logical error rates. However, for many practical quantum error correction codes such as the surface code, owing to syndrome measurement errors, standard constructions require multiple extraction rounds—of the order of the code distance d—for fault-tolerant computation, particularly considering fault-tolerant state preparation. Here we show that logical operations can be performed fault-tolerantly with only a constant number of extraction rounds for a broad class of quantum error correction codes, including the surface code with magic state inputs and feedforward, to achieve ‘transversal algorithmic fault tolerance’. Through the combination of transversal operations7 and new strategies for correlated decoding, despite only having access to partial syndrome information, we prove that the deviation from the ideal logical measurement distribution can be made exponentially small in the distance, even if the instantaneous quantum state cannot be made close to a logical codeword because of measurement errors. We supplement this proof with circuit-level simulations in a range of relevant settings, demonstrating the fault tolerance and competitive performance of our approach. Furthermore, our work sheds new light on the theory of quantum fault tolerance and has the potential to reduce the space–time cost of practical fault-tolerant quantum computation by over an order of magnitude.

Zhou, Hengyun [QuEra Computing, Boston, MA (United↗

The H I absorption zoo: JVLA extension to z ~ 0.4

Here, we present an H I 21 cm absorption study of a sample of 26 radio-loud active galactic nuclei (AGN) at 0.25 < z < 0.4 carried out with the Karl G. Jansky Very Large Array. Our aim was to study the rate of incidence of H I in different classes of radio AGN, the morphology and kinematics of the detected H I, and the nature of the interaction between the H I and the radio source at these redshifts. Our sample consists of 14 sources with sizes of up to tens of kpc and 12 compact sources (< a few kpc) in the radio-power range 10 25.7 W Hz –1 –10 26.5 W Hz –1 . We detect H I in five sources, corresponding to a detection rate of ~19%. Within the error bars, this agrees with the detection rate found at lower redshifts. We find that the rest-frame UV luminosities of most of the sources in the sample, including all the detections, are below the proposed threshold above which the H I is supposed to have been ionised. An analysis of the optical emission-line spectra of the sources shows that despite their high radio powers, about one-third of the sample, including two detections, are low-ionisation sources. The radio continuum emission from the sources detected in H I is unresolved at ~5 to 10 kpc scales in our observations, but shows extended structure on parsec scales. We analysed the H I 21 cm absorption spectra of the detections to understand the morphology and kinematics of H I. The absorption profiles are mostly complex with widths between the nulls ranging from ~60 km s –1 to 700 km s –1 . These detections also exhibit remarkably high H I column densities in the range ~10 21 cm –2 –10 22 cm –2 for T spin = 100 K and unit covering factor. Our modelling of the H I 21 cm absorption profiles suggests that in two sources the gas appears to be disturbed, and in three cases, including one with disturbed H I, the majority of the absorption is consistent with it arising from an H I disc. Despite the high radio power of our sources, we do not detect fast outflows. However, the optical emission lines in these detections show the presence of significantly disturbed gas in the nuclear regions in the form of very wide and highly blueshifted emission-line components. Since some of our detections are also low-ionisation AGN, it is quite possible that this disturbance is caused by the radio jets. Overall, our findings point towards a continuation of the low-z trends in the H I detection rate and the incidence of H I in radio AGN up to z ~ 0.4.

79 ASTRONOMY AND ASTROPHYSICS↗

Observing Quantum Measurement Collapse as a Learnability Phase Transition

During a quantum measurement, superpositions of states with different observable properties probabilistically collapse into one with a sharp value of the measured observable. In macroscopic quantum systems, this collapse arises via a continuous measurement-induced phase transition (MIPT) at a critical value of the strength of interaction with the measurement apparatus. MIPTs lie outside established paradigms for equilibrium or nonequilibrium critical phenomena and delineate distinct, stable dynamical and computational phases of matter. Quantum computers enable programmable simulation of the interaction of a measurement apparatus with a dynamical quantum system, to explore MIPT phenomena over a range of system sizes while retaining quantum coherence. Yet, existing experimental protocols rely on fundamentally nonscalable postselection techniques or direct classical simulation of quantum circuits. Here, we report the scalable observation of finite-size scaling evidence for an observable-sharpening MIPT in monitored quantum circuits in a chain of Yb + 171 ions in Quantinuum’s H1-1 trapped-ion quantum processor. By leveraging an equivalent description as a statistical physics problem, we implement scalable classical algorithms to infer the value of the measured observable from a single experimental shot. This technique enables a truly scalable protocol to observe observable-sharpening MIPTs in generic classes of circuits that cannot be directly classically simulated and also provides enhanced means to detect and suppress errors in the quantum simulation. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated pipeline framework for processing of large-scale building energy time series data

Commercial buildings account for one third of the total electricity consumption in the United States and a significant amount of this energy is wasted. Therefore, there is a need for “virtual” energy audits, to identify energy inefficiencies and their associated savings opportunities using methods that can be non-intrusive and automated for application to large populations of buildings. Here we demonstrate virtual energy audits applied to large populations of buildings’ time-series smart-meter data using a systematic approach and a fully automated Building Energy Analytics (BEA) Pipeline that unifies, cleans, stores and analyzes building energy datasets in a non-relational data warehouse for efficient insights and results. This BEA pipeline is based on a custom compute job scheduler for a high performance computing cluster to enable parallel processing of Slurm jobs. Within the analytics pipeline, we introduced a data qualification tool that enhances data quality by fixing common errors, while also detecting abnormalities in a building’s daily operation using hierarchical clustering. We analyze the HVAC scheduling of a population of 816 buildings, using this analytics pipeline, as part of a cross-sectional study. With our approach, this sample of 816 buildings is improved in data quality and is efficiently analyzed in 34 minutes, which is 85 times faster than the time taken by a sequential processing. The analytical results for the HVAC operational hours of these buildings show that among 10 building use types, food sales buildings with 17.75 hours of daily HVAC cooling operation are decent targets for HVAC savings. Overall, this analytics pipeline enables the identification of statistically significant results from population based studies of large numbers of building energy time-series datasets with robust results. These types of BEA studies can explore numerous factors impacting building energy efficiency and virtual building energy audits. This approach enables a new generation of data-driven buildings energy analysis at scale.

36 MATERIALS SCIENCE↗

Processing and Archiving Camera Data Effectively for Operando Neutron Measurement of Metal Additive Manufacturing

As the name suggests, The Operando Neutron Measurement of Metal Additive Manufacturing project conducted by ORNL’s Manufacturing Demonstration Facility (MDF) is experimenting with advanced additive metal manufacturing techniques while analyzing the process using the Spallation Neutron Source’s (SNS) beamline. As part of this experiment, the MDF is seeking to employ 2 XIMEA visible light cameras and a single infrared camera to analyze and correct manufacturing in real-time. The MDF requires a solution for capturing the high-resolution data feed from the cameras with compression while preserving enough detail for their software to detect and correct errors in real time. Our solution was to develop a Robot Operating System (ROS) driver to feed the camera data into ROS. From ROS, the feed is compressed and temporarily stored locally to a stripped 4 NVMe SSD RAID array. Post-experiment, the data is transitioned to long-term storage for archival purposes.

36 MATERIALS SCIENCE↗

Random Forest Regressor-Based Approach for Detecting Fault Location and Duration in Power Systems

Power system failures or outages due to short-circuits or “faults” can result in long service interruptions leading to significant socio-economic consequences. It is critical for electrical utilities to quickly ascertain fault characteristics, including location, type, and duration, to reduce the service time of an outage. Existing fault detection mechanisms (relays and digital fault recorders) are slow to communicate the fault characteristics upstream to the substations and control centers for action to be taken quickly. Fortunately, due to availability of high-resolution phasor measurement units (PMUs), more event-driven solutions can be captured in real time. In this paper, we propose a data-driven approach for determining fault characteristics using samples of fault trajectories. A random forest regressor (RFR)-based model is used to detect real-time fault location and its duration simultaneously. This model is based on combining multiple uncorrelated trees with state-of-the-art boosting and aggregating techniques in order to obtain robust generalizations and greater accuracy without overfitting or underfitting. Four cases were studied to evaluate the performance of RFR: 1. Detecting fault location (case 1), 2. Predicting fault duration (case 2), 3. Handling missing data (case 3), and 4. Identifying fault location and length in a real-time streaming environment (case 4). A comparative analysis was conducted between the RFR algorithm and state-of-the-art models, including deep neural network, Hoeffding tree, neural network, support vector machine, decision tree, naive Bayesian, and K-nearest neighborhood. Experiments revealed that RFR consistently outperformed the other models in detection accuracy, prediction error, and processing time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward Autonomous Field Inspection of CSP Collectors With a Polarimetric Imaging Drone

We developed a polarimetric imaging drone to perform field inspections of heliostats and carried out field tests at Sandia’s National Solar Thermal Test Facility (NSTTF). The preliminary results show that Degree of Linear Polarization (DOLP) and Angle of Polarization (AOP) images greatly enhanced the edge detection results compared with the conventional visible images, supporting fast and accurate detection of heliostat mirror edges and cracks. The system holds the promise to enable future automated detection of heliostats optical errors and mirror defects.

14 SOLAR ENERGY↗

Quantum computer-enabled receivers for optical communication

Abstract Optical communication is the standard for high-bandwidth information transfer in today’s digital age. The increasing demand for bandwidth has led to the maturation of coherent transceivers that use phase- and amplitude-modulated optical signals to encode more bits of information per transmitted pulse. Such encoding schemes achieve higher information density, but also require more complicated receivers to discriminate the signaling states. In fact, achieving the ultimate limit of optical communication capacity, especially in the low light regime, requires coherent joint detection of multiple pulses. Despite their superiority, such joint detection receivers are not in widespread use because of the difficulty of constructing them in the optical domain. In this work we describe how optomechanical transduction of phase information from coherent optical pulses to superconducting qubit states followed by the execution of trained short-depth variational quantum circuits can perform joint detection of communication codewords with error probabilities that surpass all classical, individual pulse detection receivers. Importantly, we utilize a model of optomechanical transduction that captures non-idealities such as thermal noise and loss in order to understand the transduction performance necessary to achieve a quantum advantage with such a scheme. We also execute the trained variational circuits on an IBM-Q device with the modeled transduced states as input to demonstrate that a quantum advantage is possible even with current levels of quantum computing hardware noise.

97 MATHEMATICS AND COMPUTING↗