Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “equivalent circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Outdoor Deployment Data for a Four-Terminal GaAs//Si Tandem Solar Mini-Module

This dataset contains the complete outdoor measurement and analysis data for a mechanically stacked, four-terminal (4T) gallium arsenide (GaAs)//silicon (Si) tandem solar mini-module deployed from October 2019 to January 2021 at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado, USA. The data support a performance modeling and degradation analysis framework for tandem photovoltaic devices, as described in the accompanying publication. The dataset includes: (1) current–voltage (J–V) characteristics of each sub-cell measured approximately every five minutes, with extracted performance parameters; (2) spectral irradiance from an EKO MS-710 WISER spectroradiometer, along with derived spectral mismatch ratios (SMR) and average photon energy (APE); (3) one-minute resolution meteorological data from the co-located SRRL weather station and GPS-derived precipitable water vapor (PWV); (4) pre-deployment laboratory characterization (external quantum efficiency, J–V curves, standard test conditions parameters); (5) outdoor-extracted temperature and PWV correction coefficients; and (6) PVcircuit equivalent-circuit simulation outputs used for model validation. Degradation rates of −4.1 ± 0.2 %/year (GaAs) and −2.5 ± 0.9 %/year (Si) were determined using a filtering and normalization methodology adapted for fixed-tilt tandem modules. All data are provided in open, portable formats (Apache Parquet, CSV, JSON) to enable full reproducibility of the published analysis.

14 SOLAR ENERGY↗

Operating Stresses and Their Effects on Degradation of LSM-Based SOFC Cathodes

The performance of solid oxides fuel cells (SOFCs) with four different Mn excess of lanthanum strontium manganite (LSM) -based cathodes were examined under different temperatures (1,000 °C, 900 °C), current densities (0, 380, and 760 mA cm -2 ), and cathode atmospheres (p O 2 )=0.1,0.15,0.21) for durations ranging from 58 to 1,008 h. Each yttria-stabilized zirconia (YSZ) electrolyte-supported “button” cell had a porous Ni/YSZ composite anode and a porous LSM/YSZ composite cathode. The cells’ output voltage versus time were recorded and electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) measurements were performed every 24 hours. The total area specific resistance (ASR) was calculated from these measurements. The values of ASR from both EIS and LSV were comparable between each other but lower than that from durability test. Distribution of relaxation times (DRT) analysis was performed to investigate the electrochemical processes and their corresponding relaxation frequencies as well as their attributions to the total ASR. The series resistance and parallel resistance that obtained from the equivalent circuit fit of the Nyquist plot were higher at low temperature and low p O 2 regardless of LSM compositions. The area of the peaks derived from DRT analysis increased with time during individual tests. The microstructures of the tested cells were examined using scanning electron microscopy and energy-dispersive x-ray spectroscopy (SEM/EDS). Manganese oxide particles were observed near the cathode-electrolyte interface after prolonged (1,008 h) testing in air of a cell with LSM of 11% manganese excess, and after a short test (58 h) under low oxygen (p O 2 = 0.10) in a cell with LSM of 5% manganese excess. However, the role of MnOx in cell degradation is still unknown.

08 HYDROGEN↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Biconjugate Impedance Matching Control of the HERO WEC: Preprint

Effective control strategies are essential for maximizing the power output of wave energy converters (WECs). In this study, we explore the methodology of port-based modelling which can be used for bi-conjugate impedance matching, a type of reactive control that involves maximizing power transfer by setting the load (PTO) impedance to be the complex conjugate of the source impedance (WEC). Despite its foundational role in electrical engineering, this method has seen limited application in wave energy and has not yet been demonstrated in wave-powered desalination systems. We represent our complex multidisciplinary system as an equivalent circuit to explore frequency-based relations. The HERO WEC, a small-scale, modular point absorber (PA) designed for reverse osmosis desalination is used as a case study to demonstrate port-based modelling for control applications. Improving the performance of wave-powered water desalination systems could play a critical role in addressing freshwater scarcity for coastal communities, especially those in remote or disaster-prone regions.

16 TIDAL AND WAVE POWER↗

Grid Strength Assessment for High Levels of Inverter-based Resources in the Puerto Rico Power

A system-wide assessment of the Puerto Rico power system grid strength is studied when considering high levels of inverter-based resource penetration. This study is carried out in PSSE and assesses the impact of inverter-based resource (IBR) contributions in response to three-phase ground faults. A hypothetical 100% inverter-based generation scenario is created to assess the extreme impact on short circuit levels and a realistic scenario is considered to assess the impact to short circuit ratios. The overall conclusion is that short circuit capacity and current will drastically decrease in a high IBR scenario, an effect that is quantified in this paper. The short circuit ratio metric is typically used to assess the impact of IBR but generally overestimates grid strength due to not accounting for the impact from multiple IBRs. Other methods such as equivalent circuit based short circuit ratio and weighted short circuit ratio offer a more comprehensive consideration for multiple IBRs and can better account for their mutual interactions. The work presented in this paper is part of the PR100 study.

inverter based resources, PR100, grid strength↗

Time-resolved electrical potential pump – X-ray photoelectron spectroscopy probe developments for investigating dynamic processes occurring at electrochemical interfaces

Electrode–electrolyte interfaces are of critical importance in several fields, including renewable energy, corrosion, and environmental chemistry. However, investigating these interfaces under operational conditions poses considerable challenges due to the limitations of the instrumentation employed. While recent advancements in in situ and operando techniques have enhanced our comprehension of the steady-state properties of solid-liquid interfaces, the dynamic behaviors of these systems remain inadequately explored. This study introduces a time-resolved X-ray photoelectron spectroscopy (XPS) technique designed to capture transient reaction intermediates and charging dynamics at electrified interfaces. The presented proof-of-principle study demonstrates that electrochemical processes, represented by an equivalent electrical circuit (EEC) model, can be probed and understood using square wave voltage pulses of a potentiostat synchronized to the modified data acquisition of an XPS setup. This method offers a valuable alternative to traditional pump–probe techniques, facilitating the investigation of a broader range of electrochemical systems. A dedicated software package for analyzing time- and energy-resolved XPS with a focus on extracting parameters of the EEC is geared towards benchmarking different EECs in future real-world electrochemical experiments.

Electrochemistry↗

State Preparation of Antisymmetrized Geminal Power on a Quantum Computer without Number Projection

The antisymmetrized geminal power (AGP) is equivalent to the number projected Bardeen–Cooper–Schrieffer (PBCS) wave function. It is also an elementary symmetric polynomial (ESP) state. We generalize previous research on deterministically implementing the Dicke state to a state preparation algorithm for an ESP state, or equivalently AGP, on a quantum computer. Our method is deterministic and has polynomial cost, and it does not rely on number symmetry breaking and restoration. We also show that our circuit is equivalent to a disentangled unitary paired coupled cluster operator and a layer of unitary Jastrow operator acting on a single Slater determinant. Here, the method presented herein highlights the ability of disentangled unitary coupled cluster to capture nontrivial entanglement properties that are hardly accessible with traditional Hartree–Fock based electronic structure methods.

97 MATHEMATICS AND COMPUTING↗

Destructive reverse bias pinning in perovskite/silicon tandem solar modules caused by perovskite hysteresis under dynamic shading

In this work, we demonstrate how perovskite hysteresis can result in permanent reductions in power output in perovskite/silicon tandem modules—including irreversible hotspot-induced damage—from only brief periods of shading. We show that reverse bias events in which a perovskite cell is biased above a threshold voltage—which in this work we find to be as low as –1.1 V—produces a temporary reduction in power output that is of sufficient magnitude to keep the cell pinned in reverse bias after the shading event ends. As a hysteretic phenomena, this crucial failure mode may be overlooked by static models of perovskite-based solar cells. Higher reverse bias voltages exacerbate the temporary reduction in short-circuit photocurrent, which is also sensitive to the level of illumination under reverse bias. Numerical device modelling demonstrates that this effect is consistent with our understanding of perovskite hysteresis as a consequence of mobile ion-electron coupling controlling rates of non-radiative recombination over time. Measurements of the dynamic response of single-junction perovskite cells are extrapolated to two-terminal and four-terminal perovskite/silicon tandem module modelling. We validate these models with measurements from an equivalent electronic circuit that represents a two-terminal perovskite–silicon tandem mini module. Two module-level solutions are discussed that address this issue, which includes increasing the number of bypass diodes and choosing better suited silicon bottom cells with higher shunter resistance in two-terminal tandem modules.

14 SOLAR ENERGY↗

Electrically controlling and optically observing the membrane potential of supported lipid bilayers

Supported lipid bilayers are a well-developed model system for the study of membranes and their associated proteins, such as membrane channels, enzymes, and receptors. These versatile model membranes can be made from various components, ranging from simple synthetic phospholipids to complex mixtures of constituents, mimicking the cell membrane with its relevant physiochemical and molecular phenomena. In addition, the high stability of supported lipid bilayers allows for their study via a wide array of experimental probes. In this work, we describe a platform for supported lipid bilayers that is accessible both electrically and optically, and demonstrate direct optical observation of the transmembrane potential of supported lipid bilayers. We show that the polarization of the supported membrane can be electrically controlled and optically probed using voltage-sensitive dyes. Membrane polarization dynamics is understood through electrochemical impedance spectroscopy and the analysis of an equivalent electrical circuit model. In addition, we describe the effect of the conducting electrode layer on the fluorescence of the optical probe through metal-induced energy transfer, and show that while this energy transfer has an adverse effect on the voltage sensitivity of the fluorescent probe, its strong distance dependency allows for axial localization of fluorescent emitters with ultrahigh accuracy. We conclude with a discussion on possible applications of this platform for the study of voltage-dependent membrane proteins and other processes in membrane biology and surface science.

59 BASIC BIOLOGICAL SCIENCES↗

How reliable is distribution of relaxation times (DRT) analysis? A dual regression-classification perspective on DRT estimation, interpretation, and accuracy

The distribution of relaxation times (DRT) has gained increasing attention and adoption in recent years as a versatile method for analyzing electrochemical impedance spectroscopy (EIS) data obtained from complex devices like fuel cells, electrolyzers, and batteries. The DRT deconvolutes the impedance without a priori specification of a generative model, which is especially useful for interpretation and model selection when the governing principles of the system under study are not fully understood. However, DRT estimation is an ill-posed inversion problem that must be addressed with a subjective choice of regularization and tuning, which leaves substantial risk of misleading interpretations of EIS data. In this work, we suggest a new classification view of the DRT inversion to clarify DRT estimation and interpretation. We introduce a dual regression-classification framework that unifies the classification and regression views of the DRT inversion with wide-reaching implications for DRT analysis. The dual framework is employed to demonstrate a new kind of DRT inversion algorithm and develop novel evaluation metrics that capture previously ignored aspects of DRT accuracy. These approaches are applied to both synthetic data and experimental spectra collected from a protonic ceramic fuel cell and a lithium-ion battery to illustrate their broad utility. The dual inversion algorithm shows promising performance for accurate DRT estimation and autonomous model identification, while the dual evaluation approach produces metrics that meaningfully assess the strengths and risks of DRT algorithms. Here this work provides valuable insight for both practical application of the DRT to experimental data and further development of EIS analysis methods.

36 MATERIALS SCIENCE↗

Characterization of multiterminal tandem photovoltaic devices and their subcell coupling

Three-terminal (3T) and four-terminal (4T) tandem photovoltaic (PV) devices using various materials have been increasingly reported in the literature, but measurement standards are lacking. Here, multiterminal devices measured as functions of two load variables are characterized unambiguously as functions of three device voltages or currents on hexagonal plots. We demonstrate these measurement techniques using two GaInP/GaAs tandem solar cells, with a middle contact between the two subcells, as example 3T devices with both series-connected and reverse-connected subcells. Coupling mechanisms between the subcells are quantified within the context of a simple equivalent optoelectronic circuit. Electrical and optical coupling mechanisms are most clearly revealed using coupled dark measurements. These measurements are sensitive enough to observe very small luminescent coupling from the bottom subcell to the top subcell in the prototype 3T device. Quick simplified measurement techniques are also discussed within the context of the complete characterization.

14 SOLAR ENERGY↗

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE↗

Harnessing Photoelectrochemistry for Wastewater Nitrate Treatment Coupled with Resource Recovery

Wastewater is a misplaced resource well suited to recover nutrients, value-added chemicals, energy, and clean water. A photoelectrochemical device is proposed to transform wastewater nitrates to ammonia and nitrous oxide, coupled with water oxidation. Numerical models were developed to quantify the dependence of process efficiencies and nitrogen-removal rates on light absorber band gaps, electrocatalytic kinetic parameters, competing oxygen reduction and hydrogen evolution reactions, and the reacting nitrate species concentrations that affect the mass-transfer limited current densities. With a single light-absorber and state-of-the-art catalysts, optimal solar-to-chemical efficiencies of 7% and 10% and nitrogen-removal rates of 260 and 395 gN m -2 day -1 are predicted for nitrate reduction to ammonia and nitrous oxide, respectively. The influence of competing reactions on the performance depends on the nitrate concentration and band gap of the light absorber modeled. Oxygen reduction is more dominant than hydrogen evolution to compete with the nitrate reduction reaction, but it is mass-transfer limited. Even with kinetic parameters that enhanced the driving forces for the competing reactions, the performance is only minimally affected by these reactions for optimally selected band gaps and nitrate concentrations larger than 100 mM. Here, theoretically predicted peak nitrogen removal rates and specific energy intensities are competitive with reported estimates for electrochemical and Sharon-Anammox processes for ammonia recovery and nitrogen removal, respectively. This result, together with the added benefit of harnessing sunlight to produce value-added products, indicates promise in the photoelectrochemical approach as a tertiary pathway to recover nutrients and energy from wastewater nitrates.

25 ENERGY STORAGE↗

Modeling and Validation of Offset Cancellation for Hybrid Photonic-Electronic Transimpedance Amplifier Using All-Electronic Circuits

Hybrid photonic-electronic circuits involving crossdomain feedback signals are difficult to validate and troubleshoot. This paper describes an approach to model and validate an offset-cancellation loop for a hybrid transimpedance amplifier (TIA) using all-electronic circuits. An equivalent electrical model is developed for the tunable interferometer attenuators used for offset trimming, and it includes test features to extract the system performance. The stability analysis of the system shows 75 ◦ of phase margin and 102 dB of gain margin. Measurement results demonstrate good agreement with analysis and successful TIA offset cancellation.

Marchant, Jared↗

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Effect of a Reduction in the Catalyst Loading on a Mini Passive Direct Methanol Fuel Cell

Mini passive direct methanol fuel cells (mpDMFCs) appear to be a promising alternative for powering portable devices, since they use a liquid fuel, have a fast refuelling time, have a high efficiency and have a low environmental impact. However, some issues need to be solved before their commercialization, such as methanol crossover, short lifetime and high costs. The present work studies the effect of reducing the anode and cathode catalyst loading on the performance of a mpDMFC towards a reduction in the system costs and the characterization of the system losses. The undesirable losses that affect the fuel cell performance were identified and quantified using the electrochemical impedance spectroscopy (EIS) technique. Accordingly, a novel equivalent electric circuit (EEC) was proposed, accurately reproducing the mini pDMFC. In this work, a maximum power density of 7.07 mW cm−2 was obtained, with a methanol concentration of 5 M, using 2 mg cm−2 Pt-RuB and 4 mg cm−2 PtB. The mpDMFC allowed the cell to work with high methanol concentrations and reduced anode catalyst loadings.

Moreira, C. S.↗

Initial-State Dependent Optimization of Controlled Gate Operations with Quantum Computer

There is no unique way to encode a quantum algorithm into a quantum circuit. With limited qubit counts, connectivity, and coherence times, a quantum circuit optimization is essential to make the best use of near-term quantum devices. We introduce a new circuit optimizer called AQCEL, which aims to remove redundant controlled operations from controlled gates, depending on initial states of the circuit. Especially, the AQCEL can remove unnecessary qubit controls from multi-controlled gates in polynomial computational resources, even when all the relevant qubits are entangled, by identifying zero-amplitude computational basis states using a quantum computer. As a benchmark, the AQCEL is deployed on a quantum algorithm designed to model final state radiation in high energy physics. For this benchmark, we have demonstrated that the AQCEL-optimized circuit can produce equivalent final states with much smaller number of gates. Moreover, when deploying AQCEL with a noisy intermediate scale quantum computer, it efficiently produces a quantum circuit that approximates the original circuit with high fidelity by truncating low-amplitude computational basis states below certain thresholds. Our technique is useful for a wide variety of quantum algorithms, opening up new possibilities to further simplify quantum circuits to be more effective for real devices.

97 MATHEMATICS AND COMPUTING↗

HEMP Testing of Substation Yard Circuit Breaker Control and Protective Relay Circuits

There are concerns about the effects of High-Altitude Electromagnetic Pulses (HEMP) on the electric power grid. Activities to date tested and analyzed vulnerability of digital protective relays (DPRs) used in power substations, but the effect of HEMP on the greater substation environment is not well known. This work establishes a method of testing the vulnerability of circuit breaker control and protective relay circuits to the radiated E1 pulse associated with HEMP based on coupling to the cables in a substation yard. Two DPRs from Schweitzer Engineering Laboratories, Inc. were independently tested. The test setup also included a typical cable in a substation yard with return plane to emulate the ground grid and other ground conductors near the yard cable, cabinetry housing the installed DPRs, station battery and battery charger, terminal block elements, and a breaker simulator to emulate a substation yard configuration. The DPRs were powered from the station battery and the transformer inputs energized with a three-phase source to maintain typical operating conditions during the tests. Vulnerability testing consisted of a conducted E1 pulse injected into the center of the yard cable of the DPR circuits. Current measurements on the yard cable and DPR inputs indicated significant attenuation of the conducted pulse arriving at the control house equipment from the emulated substation yard. This reduction was quantified with respect to the equivalent open-circuit voltage on the yard cable. No equipment damage or undesired operation occurred on the tested circuits for values below 180 kV, which is significantly higher than the anticipated coupling to a substation yard cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗