Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Energy and Nutrient Intake Monitoring

A passive system to determine the in-flight intake of nutrients is developed. Nonabsorbed markers placed in all foods in proportion to the nutrients selected for study are analyzed by neutron activation analysis. Fecal analysis for each market indicates how much of the nutrients were eaten and apparent digestibility. Results of feasibility tests in rats, mice, and monkeys indicate the diurnal variation of several markers, the transit time for markers in the alimentary tract, the recovery of several markers, and satisfactory use of selected markers to provide indirect measurement of apparent digestibility. Recommendations are provided for human feasibility studies.

Luckey, T. D.↗

(abstract) Low Energy Flux and Spectral Monitoring of Cen A and NGC 4151

We present available BATSE Earth-occultation observations of Cen A (the brightest extragalactic hard X-ray source) and NGC 4151 (the archetypical Seyfert I) from 1991 May through 1992 February, in the 20 keV to 1.5 MeV range. We compare the results with those obtained by OSSE during viewing periods 4 (NGC 4151) and 12 (Cen A). In general Earth-occultation sensitivities achieved by BATSE are a few times poorer than those attainable by OSSE, but sources are observable almost continuously, during all CGRO viewing periods. Data from the two instrumants are thus nicely complementary.

Cen A NGC 4151 X-ray spectra Earth-occultation↗

Raising the Bar in High Performance Laboratory Design

Laboratory facilities are expensive to build and operate, they consume energy at high rates compared to other types of buildings, and modifications are frequently required to accommodate ever-changing research activities. PNNL sought ways to address these issues in the design and construction of a 14,700 sq. ft. new laboratory building. To improve adaptability to change a high roof structure was used that allows raising the ceiling when needed with minimal disruption to installed HVAC and electrical utilities. Also, HVAC equipment was located on a mezzanine above the central corridor rather than above ceilings. This eliminates the need for maintenance personnel to routinely access lab spaces, reducing disruption to research staff and improving maintenance access. To improve the reliability of operations while reducing energy consumption, heat pipe heat recovery with evaporative cooling, zoned heating/cooling coils, high-efficiency condensing boilers, district cooling, VAV fume hoods, DDC controls, energy use monitoring, and implementation of the US Department of Energy’s Guiding Principles for Federal Leadership in Sustainable Buildings were all used. The energy model developed during design projected energy use at 2,840 MBtu/yr, a 13.5% savings over ASHRAE Standard 90.1-2010. The first full year of operation resulted in actual energy use of 2,661 MBtu, a savings of 19% over Standard 90.1. As a result of the project design’s demonstrated success, these strategies will be incorporated into a significantly larger (125,000 sq ft), $65 million lab facility to be constructed on the PNNL campus in 2020.

Scott, Jeffery M.↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Groundwater Monitoring Report, U.S. Department of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

This report contains the groundwater and surface water monitoring data obtained during calendar year (CY) 2019 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) on the DOE Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee. The monitoring data were obtained from wells, springs, and surface water sampling locations in three hydrogeologic regimes at Y-12. The Bear Creek Hydrogeologic Regime (Bear Creek Regime) encompasses a section of Bear Creek Valley (BCV) between the west end of Y-12 and the west end of the Bear Creek Watershed (directions are in reference to the Y-12 grid system, shown as Plant North. The Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime) encompasses the Y-12 industrial facilities and support structures in BCV. The Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime) encompasses a section of Chestnut Ridge directly south of Y-12. Background information in Section 2 of this report outlines the hydrogeologic framework for groundwater and surface water quality monitoring at Y-12 and includes an overview of the groundwater contamination in each hydrogeologic regime. Section 3 provides details regarding the groundwater and surface water sampling and analysis activities implemented under the Y-12 GWPP, including sampling locations and frequency, sample collection and handling, field measurements and laboratory analytes, quality assurance (QA)/quality control (QC) sampling, data management, and data quality assessment (DQA). However, the equivalent QA/QC or DQA information for the groundwater and surface water data associated with the monitoring programs implemented by UCOR are not included in this report and instead are deferred to referenced programmatic plans and reports issued by OREM and UCOR. Section 4 of this report presents a summary evaluation of the CY 2019 monitoring data with regard to the respective objectives of surveillance monitoring and exit pathway/perimeter monitoring. The evaluation is based primarily on the analytical results for the following principal groundwater contaminants at Y-12: nitrate, uranium, gross alpha activity, gross beta activity, and volatile organic compounds (VOCs). Section 5 summarizes the most significant findings with respect to the principal contaminants along with recommendations for any proposed changes to the ongoing groundwater and surface water quality monitoring performed under the Y-12 GWPP. Technical reports and plans cited in the narrative sections of the report are listed in Section 6. Narrative sections of this report reference several appendices. Figures (maps and diagrams) and data tables (excluding data summary tables incorporated in the narrative sections) are in Appendix A and Appendix B, respectively. Appendix C contains construction details for each well sampled during CY 2019 by either the Y-12 GWPP or UCOR, along with schematic diagrams for wells equipped with Westbay™ multiport sampling equipment or Barcad® pump systems. Appendix D supports the background summary discussion in Section 2 and provides more detailed information about the hydrogeologic framework for groundwater and surface water monitoring at Y-12, including the primary sources of groundwater contamination in each hydrogeologic regime. Results for all field measurements and laboratory analyses obtained by the Y-12 GWPP and UCOR are presented in Appendix E, which also includes the sample numbers for the QA/QC samples associated with groundwater and surface water monitoring performed by the Y-12 GWPP.

54 ENVIRONMENTAL SCIENCES↗

Multiparameter optical fiber sensing for energy infrastructure through nanoscale light–matter interactions: From hardware to software, science to commercial opportunities

Monitoring of energy infrastructure through robust yet economical sensing platforms is becoming an area of increased importance, with ubiquitous applications including the electrical grid, natural gas and oil transportation pipelines, H2 infrastructure (storage and transportation), carbon storage, power generation, and subsurface environments. Plasmonic and functional nanomaterial enabled fiber optic sensors show excellent promise for a wide range of sensing applications due to their versatility to be engineered for specific analytes of interest while retaining inherent advantages of the optical fiber sensor platform. Through the design of novel sensing layers, the optical transduction mechanism and wavelength dependence can also be tailored for ease of integration with low-cost interrogation systems enabling an inexpensive yet highly functional optical fiber sensing platform. In addition, recent advances in artificial intelligence and machine learning theoretical methods have been leveraged to simultaneously extract multiple parameters through multi-wavelength interrogation such that unique wavelengths can also serve as unique sensing elements, analogous to electronic nose sensor technologies. The concept of an optical fiber based “photonic nose” via multiple interrogation wavelengths and/or sensor nodes offers a compelling platform technology to realize multiparameter speciation of chemical analytes within complex gas mixtures. In this Perspective, we further generalize the notion of multiparameter sensing through the novel “photonic nervous system” concept based upon low-cost, functionalized optical fiber sensor probes monitoring a variety of distinct analyte classes (physical, chemical, electromagnetic, etc.) simultaneously to provide broad situational awareness via integrated sensors.

Su, Yang-Duan (ORCID:0000000214820902)↗

TPSAS-NF1676L-33912-DND

The agricultural, renewable energy management, and science communities need global surface and top-of-atmosphere (TOA) radiative fluxes on a near real-time basis for uses such as building energy performance monitoring and seasonal crop yield modeling. The Clouds and Earth's Radiant Energy System (CERES) FLASHFlux (Fast Longwave and SHortwave radiative Flux) data products address this need by enhancing the speed of CERES processing using simplified calibration, averaging techniques and fast radiation parameterizations to produce global fluxes within a week of satellite observations. The CERES FLASHFlux provides two data products: 1) an hourly Level 2 Single Scanner Footprint (SSF) data separately for Aqua and Terra observations, and 2) a daily Level 3 Time Interpolated and Spatially Averaged (TISA) 1degree x 1degree gridded data that combines Aqua and Terra observations. The CERES FLASHFlux Version4A includes an update to process MODIS Collection 6.1 in an improved cloud retrieval algorithm, and an update to the CERES Edition 4 angular distribution models. We inter-compared FLASHFlux Version4A, FLASHFlux Version3C, and CERES EBAF (Energy Balanced and Filled) Top-of-Atmosphere fluxes to evaluate these improvements. We also compare both SSF overpass and TISA radiative flux products to a set of surface measurement sites that are globally distributed and assess agreement. FLASHFlux TISA and CERES EBAF are used in the analysis of TOA anomalies for the annual State of Climate report. This also poster highlights the methodology use to merge the two data products by correcting the bias in FLASHFlux TISA and inter-calibrate to CERES EBAF.

Parnchai K Sawaengphokhai↗

Detection of very-high-energy gamma-ray transients with monitoring facilities

ABSTRACT The observation of very-high-energy γ-rays (VHE γ-rays, $E \gt 100\,$ GeV) has ledto the identification of extremely energetic processes and particle-acceleration sites both within our Galaxy and beyond. It is expected that VHE facilities, such as the Cherenkov Telescope Array, will explore these sources with an unprecedented level of detail. However, the transient and unpredictable nature of many important processes means that their observation requires the development of proper monitoring strategies. In this study, we estimate the properties of VHE transients that can be effectively detected by monitoring facilities. We use data collected by the Fermi-LAT instrument during its monitoring campaign to select events that are probably associated with VHE emission. We use this sample to estimate the frequency, the luminosity and the time-scales of various transients, focusing on blazar flares and gamma-ray bursts. We discuss how the balance between the field of view, sensitivity and duty cycle of an observatory affects the likelihood of detecting transients that occur at the inferred rates, and we conclude by describing the contribution that current and near-future monitoring facilities can make to the identification and study of VHE transient emission.

La Mura, G.↗

Triton Field Trials - Changes in Habitats, a Literature Review of Monitoring Technologies

Marine energy devices are installed in highly dynamic environments and have the potential to affect benthic and pelagic habitats around them. Regulatory bodies often require baseline characterization and/or post-installation monitoring to determine whether changes in these habitats are being observed. However, a great diversity of technologies is available for surveying and sampling marine habitats. Selecting the most suitable instrument to identify and measure changes in habitats at marine energy sites can become a daunting task. We conducted a thorough review of journal articles, survey reports, and grey literature to extract information about the technologies used, the data collection and processing methods, and the performance and effectiveness of these instruments. We examined documents related to marine energy development, offshore wind farms, oil and gas offshore sites, and other marine industries around the world over the last 20 years, as well as national and international guidelines for surveying habitats around offshore activities. A total of 120 different technologies were identified across six main habitat categories: seafloor, sediment, infauna, epifauna, pelagic, and biofouling. The technologies were organized into 12 broad technology classes: acoustic, corer, dredge, grab, hook and line, net and trawl, plate, remote sensing, scrape samples, trap, visual, and others. Visual was the most common and the most diverse technology class, with applications across all six habitat categories. Sampling designs varied considerably among the reviewed studies but transect was the predominant design for surveying seafloor, epifauna, and pelagic habitats. The most common data analyses were univariate and multivariate statistical analyses aimed at calculating and comparing biodiversity indices, characterizing faunal assemblages or sediment classes, or modeling the distribution of animals related to abiotic parameters. Technologies and sampling methods adaptable and designed to work efficiently in energetic environments have greater success at marine energy sites. In addition, sampling designs and statistical analyses should be carefully thought through to identify differences in faunal assemblages and spatiotemporal changes in habitats.

16 TIDAL AND WAVE POWER↗

Detecting Tooth Damage in Geared Drive Trains

This paper describes a method that was developed to detect gear tooth damage that does not require a priori knowledge of the frequency characteristic of the fault. The basic idea of the method is that a few damaged teeth will cause transient load fluctuations unlike the normal tooth load fluctuations. The method attempts to measure the energy in the lower side bands of the modulated signal caused by the transient load fluctuations. The method monitors the energy in the frequency interval which excludes the frequency of the lowest dominant normal tooth load fluctuation and all frequencies above it. The method reacted significantly to the tooth fracture damage results documented in the Lewis data sets which were obtained from tests of the OH-58A transmission and tests of high contact ratio spiral bevel gears. The method detected gear tooth fractures in all four of the high contact ratio spiral bevel gear runs. Published results indicate other detection methods were only able to detect faults for three out of four runs.

Nachtsheim, Philip R.↗

A Unified Data Infrastructure for Biological and Environmental Research: A Report from the BER Advisory Committee

The Biological and Environmental Research (BER) program within the U.S. Department of Energy (DOE) Office of Science supports large-scale data generation efforts across its two divisions: Biological Systems Science and Earth and Environmental Systems Sciences. These efforts include user facilities in atmospheric radiation measurements, genomics, metabolomics, proteomics, compute, and imaging. In addition, BER supports the development of plant-based fuels; research in biosystems design, environmental microbiomes, and atmospheric systems; energy flux monitoring; climate-based ecosystem experiments; pathogen biopreparedness; and modeling of climate, urban interfaces, and interactions between people and energy resources. For data access, BER supports community data services at its user facilities, along with specialized data initiatives for Earth and environmental science, climate modeling, genomic and microbial analysis, and multisector dynamics modeling.

54 ENVIRONMENTAL SCIENCES↗

Leveraging Environmental Monitoring Results from Department of Energy Sites for Research on the Food-Energy-Water Nexus

The Annual Site Environmental Report (ASER) from a U.S. Department of Energy (DOE) Site summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and restoration and surveillance monitoring programs. The Savannah River Site (SRS) produces ASERs that include results of monitoring mercury levels in fish samples obtained in the vicinity of SRS. Mercury is a toxic trace metal and the methylated organic form is a neurotoxin that bioaccumulates in the food web, endangering humans and other organisms. In United States, power plants are the largest source of mercury emissions. Research Objective: To determine the patterns of mercury levels in fish samples reported in the SRS environmental monitoring reports. We developed box plot visualizations to make sense of the data as well as identify fish species, dates and location with outlier mercury content. The integration and visual representation of multi-year datasets can support decision making processes on environmental compliance and environmental sustainability conducted at U.S. DOE Sites. We are constructing datasets from textual, image and multivariable data sources in the multi-year ASERs of the U.S. DOE Savannah River Site (SRS https://www.srs.gov/general/pubs/ERsum/index.html). The Fish Surveillance for mercury presents a case study for the intersection of food, energy and water systems. The dataset of 864 records (2008 and 2009) of mercury levels includes water location of fish, fish species, collection date and mercury content of fish sample. The patterns of mercury levels in the fish species as well as locations provide knowledge for further investigations. A research area for future studies is the composition of microbial communities in fish guts of varying levels of mercury.

54 ENVIRONMENTAL SCIENCES↗

Laser-induced fluorescence of CN/X2 Sigma +/ produced by photolysis of C2N2 at 160 nm

The paper reports laser-induced fluorescence measurements of the initial product state distributions of CN(X2 Sigma +) produced during the photolysis of C2N2 at a wavelength of 160 nm. The parent molecules were photodissociated by an argon flash lamp, and saturated solutions of BBD in p-dioxane were used as a laser dye to produce radiation that excited CN radicals in the (upsilon-double-prime, N-prime) vibrational-rotational sublevels of the X state to the B-state sublevels. Spectral-line identification is discussed along with the observed rotational, electronic, and vibrational energy partitionings. The effect of added buffer gas (N2 or He) on the observed product state distributions is examined in order to monitor collisional energy transfer from CN(A2 Pi, upsilon = 0) to CN(X2 Sigma +, upsilon-double-prime = 4). It is found that both buffer gases produce population inversion between the upsilon-double-prime = 4 and upsilon-double-prime = 3 levels of the X state.

Cody, R. J.↗