Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy management systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Integrated Energy Systems Program Management Plan

In 2012, the U.S. Department of Energy (DOE) Office of Nuclear Energy (NE) initiated the Nuclear Energy Enabling Technology Program, which includes the Crosscutting Technology Development (CTD) portfolio of subprograms, to conduct research, development, and demonstration (RD&D) to support existing, new and advanced reactor designs and fuel cycle technologies. This program plan describes the Integrated Energy Systems (IES) Program, an element of the CTD portfolio since 2016 that seeks to improve the economic competitiveness, efficiency and environmental performance of nuclear energy systems by expanding their potential application space beyond electricity and optimizing their utilization in the context of the larger U.S. electric and non-electric energy system.

08 HYDROGEN↗

A Primer on Organizational Use of Energy Management and Information Systems (EMIS), Second edition

The document provides a high-level overview of Energy Management and Information Systems (EMIS), which are combined hardware and software products that comprise a broad family of tools and services to manage commercial building energy use. It provides a common reference that can be used to understand key distinguishing factors and core attributes of different solutions within the family of EMIS technologies. This is a 2021 update to the original 2015 edition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comprehensive Review of Practical Issues for Interoperability Using the Common Information Model in Smart Grids

Smart grids with interoperability improve grid reliability by collecting system information and transferring it to an energy management system and associated applications through a seamless end-to-end connection. To achieve interoperability, it is required to exchange the semantic information within the different domains. The international electrotechnical commission has established the Common Information Model (CIM) tool, which is a standard application programming interface for the exchange of semantic information in power systems. CIM provides a robust framework for accurate data sharing, merging, and transformation into reusable information. However, as CIM provides a basic framework for information exchange, various practical issues arise in establishing an energy management system capable of exchanging information using CIM. This paper aims to offer a comprehensive understanding by summarizing and categorizing the research on the practical use of CIM for interoperability in smart grids. Many papers are analyzed and the issues are classified into CIM extension, harmonization, and validation to address the issues that arise when establishing an integrated information exchange system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fiber Optic Sensing Technologies for Battery Management Systems and Energy Storage Applications

Applications of fiber optic sensors to battery monitoring have been increasing due to the growing need of enhanced battery management systems with accurate state estimations. The goal of this review is to discuss the advancements enabling the practical implementation of battery internal parameter measurements including local temperature, strain, pressure, and refractive index for general operation, as well as the external measurements such as temperature gradients and vent gas sensing for thermal runaway imminent detection. A reasonable matching is discussed between fiber optic sensors of different range capabilities with battery systems of three levels of scales, namely electric vehicle and heavy-duty electric truck battery packs, and grid-scale battery systems. The advantages of fiber optic sensors over electrical sensors are discussed, while electrochemical stability issues of fiber-implanted batteries are critically assessed. This review also includes the estimated sensing system costs for typical fiber optic sensors and identifies the high interrogation cost as one of the limitations in their practical deployment into batteries. Finally, future perspectives are considered in the implementation of fiber optics into high-value battery applications such as grid-scale energy storage fault detection and prediction systems.

25 ENERGY STORAGE↗

Packetized energy management control systems and methods of using the same

Aspects of the present disclosure include anonymous, asynchronous, and randomized control schemes for distributed energy resources (DERs). Such control schemes may include packetized energy management (PEM) control schemes for managing DERs that may provide near-optimal tracking performance under imperfect information and consumer quality of service (QoS) constraints.

Frolik, Jeffrey↗

K-anonymity applied to the energy grid of things distributed energy resource management system

Smart grid infrastructure relies on information exchange between multiple actors in order to ensure system reliability. These actors include but are not limited to smart loads, grid control, and energy management technologies. As information exchange between these actors is susceptible to cyber-attacks, security and privacy issues are indispensable to ensure a reliable and stable grid. This position paper proposes a privacypreserving, trust-augmented secure scheme for a smart grid implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyberattacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyberattack scenarios on matrix completion. Realistic cyberattack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation: Preprint

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyber attacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyber attack scenarios on matrix completion. Realistic cyber attack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Tangible Solutions for Grid Operation Upgrade

Many countries worldwide are setting clean energy targets to decarbonize the energy sector and add higher wind and solar capacities. Given their distributed nature, variable renewable energy (VRE) assets can have unique grid integration considerations, and require grid operation practices to be modernized. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage renewable energy resource operation in the system control center. Further, system operation planning is conducted with VRE and load forecasting to enable reliable real-time system operation. NREL has partnered with many system operators in the region to identify appropriate technology and grid modernization solutions. NREL and partners from system operators in the region will present on the challenges and some solutions that have been applied and share best practices such as energy management system upgrades, VRE forecasting framework, grid flexibility improvements, and staff training.

emerging economies↗

Sustainable Campus with PEV and Microgrid

Market penetration of electric vehicles (EVs) is gaining momentum, as is the move towards increasingly distributed, clean and renewable electricity sources. EV charging shifts a significant portion of transportation energy use onto building electricity meters. Hence, integration strategies for energy-efficiency in buildings and transport sectors are of increasing importance. This paper focuses on a portion of that integration: the analysis of an optimal interaction of EVs with a building-serving transformer, and coupling it to a microgrid that includes PV, a fuel cell and a natural gas micro-turbine. The test-case is the Nanyang Technological University (NTU), Singapore campus. The system under study is the Laboratory of Clean Energy Research (LaCER) Lab that houses the award winning Microgrid Energy Management System (MG-EMS) project. The paper analyses three different case scenarios to estimate the number of EVs that can be supported by the building transformer serving LaCER. An approximation of the actual load data collected for the building into different time intervals is performed for a transformer loss of life (LOL) calculation. The additional EV loads that can be supported by the transformer with and without the microgrid are analyzed. The numbers of possible EVs that can be charged at any given time under the three scenarios are also determined. The possibility of using EV fleet at NTU campus to achieve demand response capability and intermittent PV output leveling through vehicle to grid (V2G) technology and building energy management systems is also explored.

Singh, Reshma↗

Energy Management and Information Systems (EMIS) Specification and Procurement Support Materials

This annotated Request for Proposal (RFP) template includes an Energy Management and Information System (EMIS) technology specification, an ongoing services specification, RFP evaluation criteria, and more. It is designed to guide building professionals through the specification, procurement, and selection of an EMIS or related building performance monitoring and diagnostic technology.

building performance↗

Voltage Regulation Performance Evaluation of Distributed Energy Resource Management via Advanced Hardware-in-the-Loop Simulation

This paper evaluates the performance of coordinated control across advanced distribution management systems (ADMS), distributed energy resources (DERs), and distributed energy resource management systems (DERMS) using an advanced hardware-in-the-loop (HIL) platform. This platform provides a realistic laboratory testing environment, including accurate dynamic modeling of a real-world distribution system from a utility partner, real controllers (ADMS and DERMS), physical power hardware (DERs), and standard communications protocols. One grid service—voltage regulation—is evaluated to show the performance of the coordinated grid automation system. The testing results demonstrate that the coordinated DERMS and ADMS system can effectively regulate system voltages within target operation limits using DERs. The realistic laboratory HIL testing results give utilities confidence in adopting the grid automation systems to manage DERs to achieve system-level control and operation objectives (e.g., voltage regulation). This helps utilities mitigate potential risks (e.g., instability) prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Roles of Dynamic State Estimation in Power System Modeling, Monitoring and Operation

—Power system dynamic state estimation (DSE) remains an active research area. This is driven by the absence of accurate models, the increasing availability of fast-sampled, time synchronized measurements, and the advances in the capability, scalability, and affordability of computing and communications. This paper discusses the advantages of DSE as compared to static state estimation, and the implementation differences between the two, including the measurement configuration, modeling framework and support software features. The important roles of DSE are discussed from modeling, monitoring and operation aspects for today’s synchronous machine dominated systems and the future power electronics-interfaced generation systems. Several examples are presented to demonstrate the benefits of DSE on enhancing the operational robustness and resilience of 21st century power system through time critical applications. Future research directions are identified and discussed, paving the way for developing the next generation of energy management systems.

Zhao, Junbo↗

Energy Management and Product Sustainability Standards – A Key Link to Sustainable Supply Chains

Reducing supplier energy consumption can be critical to creating more sustainable and resilient supply chains, and can be achieved by embedding criteria for energy management systems into product sustainability standards. Manufacturers across the globe are taking steps to reduce their greenhouse gas emissions and become more sustainable. Large industrial corporations rightly tout their efforts and successes. However, their upstream emissions, that is, the emissions from companies supplying components, are more difficult to address. These supplier companies are often smaller manufacturers with limited awareness or incentives to reduce emissions. Within the electronics industry, a diverse group of stakeholders is seeking to make the electronics sector more sustainable and resilient through product sustainability standards. The U.S. Department of Energy is engaged in these endeavors, including efforts to reduce supplier energy consumption by incorporating criteria into these sustainability standards that encourage the adoption of energy management systems and practices. Such activity within the electronics sector can be a significant component of a broader resilience roadmap for the sector’s supply chain. This paper highlights the efforts to embed energy management practices into electronics products supply chains to build resilience, and presents a business case using examples from U.S. manufacturers that can be replicable to other manufacturing sectors.

Tutterow, Vestal↗

Turbulence flight director analysis and preliminary simulation

A control column and trottle flight director display system is synthesized for use during flight through severe turbulence. The column system is designed to minimize airspeed excursions without overdriving attitude. The throttle system is designed to augment the airspeed regulation and provide an indication of the trim thrust required for any desired flight path angle. Together they form an energy management system to provide harmonious display indications of current aircraft motions and required corrective action, minimize gust upset tendencies, minimize unsafe aircraft excursions, and maintain satisfactory ride qualities. A preliminary fixed-base piloted simulation verified the analysis and provided a shakedown for a more sophisticated moving-base simulation to be accomplished next. This preliminary simulation utilized a flight scenario concept combining piloting tasks, random turbulence, and discrete gusts to create a high but realistic pilot workload conducive to pilot error and potential upset. The turbulence director (energy management) system significantly reduced pilot workload and minimized unsafe aircraft excursions.

Johnson, D. E.↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗