Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT)

The National Renewable Energy Laboratory (NREL) developed the Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT) to allow stakeholders to estimate the long-term aggregate electricity consumption impacts of various energy efficiency measures in Puerto Rico’s residential, commercial, and industrial sectors. PREESAT is an energy accounting framework that addresses electricity use. This report provides an overview of the tool and serves as a user manual with instructions for users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pathway to Decarbonization Through Industrial Energy Efficiency: Micro and Macro Perspectives from Compressed Air Usage

Abstract Energy audits directly provided the industrial sector with reduced energy costs and avoided emissions. Still, they also lead to far-reaching indirect and induced local, regional, and national benefits. This paper aims to present the techno-economic-environmental analysis to achieve decarbonization through implementing industrial energy efficiency at micro and macro levels. An integrated techno-economic-environmental methodology is developed. Case studies of micro-level carbon reduction efforts through industrial energy efficiency technologies are presented. The broader macroeconomic and environmental effects of technology on society are analyzed using data from 206 energy audits of industrial compressed air systems conducted over 13 years. The impacts show that energy-efficient improvements lead to direct cost savings for manufacturers, boost economic activity across sectors, and affect carbon dioxide emissions both short-term and long-term in the region. Given their extensive benefits, energy audits significantly influence policymaking. We devised a methodology to link micro-level energy audit data with macroeconomic and environmental analyses to quantify these cascading benefits. The economic scenario analysis shows that $228 M has been saved from direct industrial energy savings from implementing all compressed air recommendations in the studied periods and the region. In addition, the investment made through manufacturers would create 2,025 jobs and $383 M annually, cascading regional economic impacts. The environmental analysis shows that the regional manufacturers have directly avoided about 2.8 M metric tons of carbon dioxide emissions.

Engineering↗

Optical networking within the Lightwave Energy-Efficient Datacenter project [Invited]

The Lightwave Energy-Efficient Datacenter (LEED) project within the ARPA-e ENLITENED program is developing novel energy-efficient multichannel lightwave networks. These networks are enabled by a new optical “rotor” switch that can reconfigure the network topology in less than 20 µs and a field-programmable-gate-array-based network interface controller called Corundum that can provide precise network-wide synchronization of packets admitted into the lightwave network. Here we review the optical networking research within LEED and discuss future directions.

Mellette, William M.↗

Energy Efficiency: What Has Research Delivered in the Last 40 Years?

This article presents a critical assessment of 40 years of research that may be brought under the umbrella of energy efficiency, spanning different aggregations and domains—from individual producing and consuming agents to economy-wide effects to the role of innovation to the influence of policy. After 40 years of research, energy efficiency initiatives are generally perceived as highly effective. Innovation has contributed to lowering energy technology costs and increasing energy productivity. Energy efficiency programs in many cases have reduced energy use per unit of economic output and have been associated with net improvements in welfare, emission reductions, or both. Rebound effects at the macro level still warrant careful policy attention, as they may be nontrivial. Complexity of energy efficiency dynamics calls for further methodological and empirical advances, multidisciplinary approaches, and granular data at the service level for research in this field to be of greatest societal benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applying Value at Risk Analysis towards Energy Efficiency Investments

Value at Risk (VaR) is a measure of risk for potential losses within a portfolio of investments. Investments in energy efficiency in a manufacturing environment compete in terms of payback period, ease of investment, and transaction costs with other investments (production, safety, engineering, etc.). Because manufacturers have limited amounts of capital to allocate, investments in productivity tend to be prioritized over energy efficiency projects that offer similar paybacks. Value at Risk (VaR) can be used to quantify how risk-weighted expenditures change over time. Energy efficiency investments are often believed to offer relatively stable payoffs compared to changes in production and other assets, particularly when evaluated using methodologies such as simple payback. Incorporating methodologies such as VaR can provide a stronger business case for energy efficiency investments by quantifying value beyond what is captured in other Return on Investment calculations.In this paper we outline a methodology for applying VaR in the context of the variety of investments made by manufacturing organizations. Additionally, we profile the stability of energy efficiency (EE) and renewable energy (RE) investments compared to other types of investments made in manufacturing. By applying VaR to these investments, energy managers can better translate the financial benefits of energy-related capital projects in a way that is more compelling to Corporate Finance and Treasury departments. This common language also allows Corporate Finance and Treasury departments to support large, strategic deployments of capital for such projects based on a targeted objective – the management of financial risk for the organization’s shareholders.

Levine, Eli↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Akiachak Energy Efficiency Retrofit Project

The goal of the project is to reduce the overall energy use of the Akiachak Native Community (ANC) by implementing energy efficiency measures in five high-use Tribal buildings. This project will have the following outcomes: Projected annual energy savings of $17,369; projected annual reduction in fuel oil #1 of 1,200 gallons and electricity of 17,751 kWh; annual reduction in carbon dioxide emissions of approximately 60,340 pounds/year. ANC will install energy efficiency measures in the Laundry, Tribal Indian Reorganization Act (IRA) Office, Clinic, Daycare, and Police Station. ANC obtained energy audits on these buildings in 2018, and this project will implement high-payback recommendations such as replacing lighting with LEDs, installing setback thermostats and occupancy sensors, replacing furnaces with more efficient models, replacing the circulation pumps with variable speed ones, air tightening, and adding insulation. Buildings will see energy cost reductions from 15% to 40%. These retrofits will help build ANC’s long-term vision for sustainable energy usage and address the first goal of the Tribal IRA Council’s Energy Efficiency and Conservation Strategy, to “create and maintain functionally appropriate, sustainable, accessible, high quality tribal infrastructure and facilities.” ANC intends to replicate this project by using the resulting energy savings to address audit recommendations in other buildings as well as to demonstrate the value of energy efficiency to community members. Other outcomes will include an increase in community resiliency, reduced dependence on outside shipments of fuel oil, training for maintenance staff, and no-touch control of building appliances to reduce transmission of diseases such as COVID-19.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residential Home Repairs, Energy Efficiency, and Electrification in the Hill District of Pittsburgh [Slides]

Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies. This report summarizes the insights from stakeholder engagement with organizations that provide home repair services, weatherization, and residential energy efficiency in the Hill District as well as from a building analysis to characterize Hill District housing stock and the potential costs and benefits of energy efficiency and electrification measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing Residential Energy Usage Baselines and Energy Efficiency Options

FCPC has been a leader in energy conservation not only in the State of Wisconsin, but nationally, as well. In 2016, the Environmental Protection Agency (EPA) ranked FCPC 11th in its Top 30 Local Government List as a result of the extensive measures the Tribe has taken toward its goal of achieving 100% carbon-neutral energy independence. Some of these efforts include the reduction of the Tribal government workweek to four days instead of five, the purchase of renewable energy certificates to more than offset the Tribe’s annual energy consumption, the installation of solar photovoltaic systems, and the completion of energy audits of Tribal government facilities. Until now, FCPC has focused on energy efficiency options for government and enterprise buildings, but it is now time to broaden the scope of energy efficiency to include the Tribe’s residential community. The Tribe’s Energy Working Group has identified the completion of home energy audits as one of its more imminent goals, as formal energy evaluations have yet to be completed on residential dwellings on the FCPC reservation. Tribal leadership is already looking ahead to the anticipated outcome of these energy audits and has taken steps to develop a cost sharing program that will assist Tribal homeowners to implement identified efficiency options as a result of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MFVI Energy Efficiency Audit Training - Module 1.1: Introduction to Efficient Lighting [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing lighting systems. As such, it will assist its user in determining the optimal lighting for a given space and then identifying the most efficient means of delivering that lighting.

21CPP↗

Design approaches to more energy efficient engines

The status of NASA's Energy Efficient Engine Project, a comparative government-industry effort aimed at advancing the technology base for the next generation of large turbofan engines for civil aircraft transports is summarized. Results of recently completed studies are reviewed. These studies involved selection of engine cycles and configurations that offer potential for at least 12% lower fuel consumption than current engines and also are economically attractive and environmentally acceptable. Emphasis is on the advancements required in component technologies and systems design concepts to permit future development of these more energy efficient engines.

Saunders, N. T.↗

Novel Energy-Efficient Drying Technologies for Food, Pulp and Paper, and other Energy Intensive Manufacturing Industries

The purpose of this project was to develop innovative dryer technologies for the food and pulp & paper industry sectors to reduce their corresponding drying energy by at least 25%. By working on these novel drying technologies and the aid of smart sensors and a physics-based artificial intelligence methodology, the foundation for the next generation energy efficient smart dryers for the food and pulp & paper industry sectors have been developed. The innovative dryer technologies developed are applicable to other energy intensive industries as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions on building stock modeling to inform energy efficiency and sustainability

To enhance economic competitiveness and ensure energy efficiency, resilience, and security, cities and governments are adopting technologies and strategies to improve their existing building stocks. This approach aims to reduce energy use, improve energy affordability, and ensure a reliable power supply while safeguarding occupants during extreme weather events that may disrupt energy services. The effectiveness of these solutions will depend on building stock characteristics, use patterns, weather conditions, evolving technologies and their markets, and a city’s socio-economic conditions. This paper presents ten questions and answers that highlight the most important issues regarding the use of building stock modeling as a powerful tool to provide insights for informing stakeholders’ actions and decision-making on energy efficiency, costs reduction, and resilience of buildings in cities. Building stock modeling should build upon the fit-for-purpose framework, balancing the use case accuracy requirements, level of complexity, and needed resources (expertise, compute). The advancements in Artificial Intelligence (AI), the increasingly available open dataset of building stock in cities, and the more affordable powerful computing will accelerate the adoption of building stock modeling across scales by researchers and practitioners to inform decision making on sustainability and efficiency.

AI↗

Air transportation energy efficiency - Alternatives and implications

Results from recent studies of air transportation energy efficiency alternatives are discussed, along with some of the implications of these alternatives. The fuel-saving alternatives considered include aircraft operation, aircraft modification, derivative aircraft, and new aircraft. In the near-term, energy efficiency improvements should be possible through small improvements in fuel-saving flight procedures, higher density seating, and higher load factors. Additional small near-term improvements could be obtained through aircraft modifications, such as the relatively inexpensive drag reduction modifications. Derivatives of existing aircraft could meet the requirements for new aircraft and provide energy improvements until advanced technology is available to justify the cost of a completely new design. In order to obtain significant improvements in energy efficiency, new aircraft must truly exploit advanced technology in such areas as aerodynamics, composite structures, active controls, and advanced propulsion.

Williams, L. J.↗

Energy Efficient Engine: Control system component performance report

An Energy Efficient Engine (E3) program was established to develop technology for improving the energy efficiency of future commercial transport aircraft engines. As part of this program, General Electric designed and tested a new engine. The design, fabrication, bench and engine testing of the Full Authority Digital Electronic Control (FADEC) system used for controlling the E3 Demonstrator Engine is described. The system design was based on many of the proven concepts and component designs used on the General Electric family of engines. One significant difference is the use of the FADEC in place of hydromechanical computation currently used.

Beitler, R. S.↗

Energy efficient transport technology: Program summary and bibliography

The Energy Efficient Transport (EET) Program began in 1976 as an element of the NASA Aircraft Energy Efficiency (ACEE) Program. The EET Program and the results of various applications of advanced aerodynamics and active controls technology (ACT) as applicable to future subsonic transport aircraft are discussed. Advanced aerodynamics research areas included high aspect ratio supercritical wings, winglets, advanced high lift devices, natural laminar flow airfoils, hybrid laminar flow control, nacelle aerodynamic and inertial loads, propulsion/airframe integration (e.g., long duct nacelles) and wing and empennage surface coatings. In depth analytical/trade studies, numerous wind tunnel tests, and several flight tests were conducted. Improved computational methodology was also developed. The active control functions considered were maneuver load control, gust load alleviation, flutter mode control, angle of attack limiting, and pitch augmented stability. Current and advanced active control laws were synthesized and alternative control system architectures were developed and analyzed. Integrated application and fly by wire implementation of the active control functions were design requirements in one major subprogram. Additional EET research included interdisciplinary technology applications, integrated energy management, handling qualities investigations, reliability calculations, and economic evaluations related to fuel savings and cost of ownership of the selected improvements.

Middleton, D. B.↗