Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An implicit, conservative and asymptotic-preserving electrostatic particle-in-cell algorithm for arbitrarily magnetized plasmas in uniform magnetic fields

Here, we introduce a new electrostatic particle-in-cell algorithm capable of using large timesteps compared to particle gyro-period under a uniform external magnetic field. The algorithm extends earlier electrostatic fully implicit PIC implementations with a new asymptotic-preserving particle-push scheme that allows timesteps much larger than particle gyroperiods. In the large-timestep limit, the integrator preserves all particle drifts, while recovering the full orbit for small timesteps. The scheme allows for a seamless, efficient treatment of particles with coexisting magnetized and unmagnetized species, and conserves energy and charge exactly without spoiling implicit solver performance. We demonstrate by numerical experiment with several problems of variable species magnetization (diocotron instability, modified two-stream instability, and drift instability) that orders of magnitude wall-clock-time speedups vs. the standard fully implicit electrostatic PIC algorithm are possible without sacrificing solution accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Best Practices for Smart Grid-Interactive Efficient Building Ready Performance Contracts

Grid-interactive efficient building (GEB) measures reduce costs and optimize energy use for additional grid services by coordinating building energy loads and providing continuous demand management. Incorporating GEB energy conservation measures (ECMs) in performance contracts is reliant upon multiple factors. These factors include site selection with utility tariffs and incentives favorable to GEB, the identification of GEB as a priority in the initial stages of the contracting process, integration of GEB within comprehensive performance contracts with multiple other ECMs, and careful consideration of GEB measurement and verification (M&V) for energy savings performance contracts (ESPCs) and performance assurance for utility energy service contracts (UESCs).

building energy loads↗

A Fundamentally New Coupled Approach to Contact Mechanics via the Dirichlet‐Neumann Schwarz Alternating Method

Contact phenomena are crucial for understanding the behavior of mechanical systems. However, existing computational approaches for simulating mechanical contact often face numerical challenges, such as inaccurate physical predictions, energy conservation errors, and unwanted oscillations. Here, we introduce an alternative technique for simulating dynamic contact based on the non‐overlapping Schwarz alternating method, originally developed for domain decomposition. In multibody contact scenarios, this method treats each body as a separate, non‐overlapping domain and prevents interpenetration using an alternating Dirichlet–Neumann iterative process. This approach has a strong theoretical foundation, eliminates the need for contact constraints, and offers flexibility, making it ideal for multiscale and multiphysics applications. We conducted a numerical comparison between the Schwarz method and traditional methods, such as the Lagrange multiplier and penalty methods, focusing on a benchmark impact problem. Our results indicate that the Schwarz alternating method outperforms traditional methods in several key areas: it provides more accurate predictions for various measurable quantities and demonstrates exceptional energy conservation capabilities. To address unwanted oscillations in contact velocities and forces, we explored various algorithms and stabilization techniques, ultimately opting for the naïve‐stabilized Newmark scheme for its simplicity and effectiveness. Additionally, we validated the efficiency of the Schwarz method in a three‐dimensional impact problem, highlighting its inherent capacity to accommodate different mesh topologies, time‐integration schemes, and time steps for each interacting body.

Schwarz alternating method↗

A New State of the Art: Zero Energy Modular Multifamily Construction

In 2020, the U.S. Department of Energy's Building Technologies Office (BTO) launched the Advanced Building Construction (ABC) Initiative. This initiative aimed to integrate energy efficiency into high-production construction practices. One focus area of the initiative is off-site construction, an approach that may achieve scalable, efficient, and high-performing construction buildings through process standardization. This report presents the findings and recommendations from our ABC Initiative project: A New State of the Art: Zero-Energy Modular Multifamily Construction System. The objectives of the BTO-funded project are to: 1) Achieve energy performance 50% better than the 2018 International Energy Conservation Code (IECC). 2) Achieve this level of energy performance at no additional cost VEIC worked with Louisiana State University (LSU), National Renewal Energy Lab (NREL), [the project team], and industry partners at the Mod Coach, KBS, and Solar Home Factory to identify and analyze multifamily business designs and modular construction practices. These designs and processes hold the promise of achieving the goals set out by the DOE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Assessment for a Microgrid in the Community of Castañer, Puerto Rico

The Cooperativa Hidroeléctrica de la Montaña (Cooperativa) and the Interstate Renewable Energy Council office in Puerto Rico (IREC) are leading the development of a community solar photovoltaic (PV) microgrid comprised of a 225 kWDC photovoltaic system tied to a 500 kWh storage system in the Community of Castañer, in the town of Lares in Puerto Rico. This microgrid will support the electricity needs of eight essential businesses and four homes. The Cooperativa and IREC requested technical assistance to help conduct a comprehensive energy efficiency assessment for the commercial buildings to maximize the impact of the solar PV microgrid. The goal was to identify energy conservation measures that would have the highest impact in terms of reducing electricity demand in order to; reduce the size and cost of the PV microgrid; and reduce the annual operating costs for building owners.

14 SOLAR ENERGY↗

Building Performance Standards and Energy Code Alignment: Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Performance Standards and Energy Code Alignment - Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets. However, some new buildings may struggle with meeting the BPS for the following reasons: 1. Energy codes focus on the design of the building and its projected ability to perform efficiently, while BPS compliance is dependent on the actual ongoing performance of the building, considering variables like occupancy, operation, and maintenance. 2. There are significant differences in the methodologies used to determine BPS compliance versus code compliance, including how each handles compliance metrics, handling of building amenities, and renewable energy generation. 3. The prescriptive compliance path in the energy code is based on performance of individual building components, as opposed to the performance compliance path which accounts for holistic building design strategies and interdependent building systems. This can result in a significant variability in post-occupancy performance for buildings built using the prescriptive path. Designs on the lower end of the permitted efficiency range may struggle with meeting the BPS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FINAL TECHINICAL REPORT THUNDERING BUFFALO HEALTH AND WELLNESS CENTER

This U.S. Department of Energy, Office of Indian Energy supported project consists of energy conservation measures (ECMs) and a solar photovoltaic (PV) system to reduce cost of utility bills in a newly constructed Fort Peck Wellness Center, for use by tribal members in improving their physical and mental wellness. Construction of the building was outside the scope of the DOE supported project. A new 2-story wellness center was designed and constructed in Poplar, Montana. The wellness center is comprised of fitness areas, gymnasium, pool and spa, offices, and BOH support areas. The building was completed and has been operational for more than a year. A final measurement and verification of energy savings was completed after one year of operation and the results are presented herein, showing an energy savings 20% higher than the originally models indicated.

14 SOLAR ENERGY↗

Household energy resilience in extreme weather events: An investigation of energy service importance, HVAC usage behaviors, and willingness to pay

Household energy resilience, particularly maintaining essential energy services within an acceptable and affordable level, is critical during extreme weather events (e.g., winter storms, heat waves) with power shortages or outages. However, the research on the importance and acceptable compromise levels of energy services, HVAC usage behavior changes, and willingness to pay (WTP) for energy services during disasters is limited. Therefore, this study investigates the importance and compromise of household energy services, HVAC usage behaviors, and WTP, as three key dimensions of household energy resilience, in both normal days and disaster scenarios through surveys (n=485). First, 12 common residential end-uses are grouped into high, mid, and low-priority services using hierarchical clustering, in which high-priority services (perceived as important and un-compromisable) include food cooking and storage (refrigerator and freezer) and thermal comfort (space heating and cooling), mid-priority services involve water heating and lighting, while low-priority services are mostly related to entertainment and housework (e.g., TV, laundry). Also, HVAC use patterns demonstrate that occupants become more energy conservative during disasters, e.g., reducing durations of running HVAC and adjusting temperature setpoints to save energy. In terms of energy cost, approximately 60% of respondents are willing to pay more to maintain energy services during disasters, although only 13% are prepared to pay over double the normal energy prices. The regression models further reveal that household energy resilience varies across different sociodemographic groups (e.g., age, income, family size) and is impacted by disaster experience and beliefs in clean energy and climate. In conclusion, these research findings provide important perspectives to understand household energy resilience and inform measures for disaster adaptation of households in extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of Photovoltaic Shading on Rooftop Heat Transfer, Building Energy Loads, and Photovoltaic Power Output

Photovoltaic (PV) modules on building rooftops provide shade from summer heating, leading to a reduction in cooling load during hot seasons. However, PV shading also reduces passive solar heating during winter months, leading to an increase in the building heating load during cold seasons. In this study, the heat transfer performance of an enclosure formed by adjacent PV modules is analyzed for three locations in the United States, comparing the daily heat flux through rooftops for the case of a PV-shaded rooftop as well as an unshaded roof. Several result metrics are developed as part of this work, including the saved energy load (SEL), or the energy conserved by adding PV-shading to the rooftop, and the additional energy load (AEL), or the supplemental building energy required to replace shaded solar heating. Lastly, this work calculates the utility factor, being the ratio of SEL and PV power output to AEL as a metric of PV effectiveness. SELs are 5.2, 6.2, and 11.7 kWh/m 2 · year for Dayton, Boise, and Phoenix, respectively, while the AELs for the same locations are 1.6, 1.5, and 2.1 kWh/m 2 · year. The utility factors for the same three locations are 61, 71, and 79. In general, locations with hot, non-cloudy summers and clear skies in winter see the largest utility factor. Further, it is shown that PV shading can conserve building energy during the winter months by preventing radiative losses to cold winter skies.

13 HYDRO ENERGY↗

Quantum Mpemba effect without global symmetries

The Mpemba effect, where a system initially farther from equilibrium relaxes faster than one closer to equilibrium, has been extensively studied in classical systems and recently explored in quantum settings. While previous studies of the quantum Mpemba effect (QME) have largely focused on isolated systems with global symmetries, we argue that the QME is ubiquitous in generic, nonintegrable many-body systems lacking such symmetries, including U(1) charge conservation, spatial symmetries, and even energy conservation. Using paradigmatic models such as the quantum Ising model with transverse and longitudinal fields, we show that the QME can be understood through the energy density of initial states and their inverse participation ratio in the energy eigenbasis. Our findings provide a unified framework for the QME, linking it with classical thermal relaxation.

Bhore, Tanmay [University of Leeds (United Kingdom↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integration of a Smart Outlet-Based Plug Load Management System with a Building Automation System

The growth of and reliance on renewable energy necessitate a multi-pronged approach to achieve grid reliability and economics. As they represent a notable portion of U.S. energy consumption, commercial buildings must play an active role in this effort. Conserving energy and responding to grid conditions through demand flexibility can be achieved through the integration of major building systems. Integration of plug and process loads with lighting and heating, ventilation, and air conditioning systems maximizes the effectiveness of integrated building energy management. In this research, we demonstrate the integration of smart outlets into a building automation system. We cover the installation process as well as the architecture required for smart outlets to communicate data to the building automation system and to receive commands back. After recording power measurements for one week as a baseline, we configured the building automation system to turn the smart outlets on and off according to a set schedule. This resulted in energy savings of 66% during 1 week on 25 plug loads. This work demonstrates that grid-interactive efficient buildings are achievable through building system integration.

building automation system↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Should We Conserve Entropy or Energy when Computing CAPE with Mixed-Phase Precipitation Physics?

Abstract The rapidly increasing resolution of global atmospheric reanalysis and climate model datasets necessitates finding methods for computing convective available potential energy (CAPE) both efficiently and accurately. To this end, this article compares two common methods for computing CAPE which conserve either energy or entropy. Inaccuracies in these computations arise from both physical and numerical errors. For instance, computing CAPE with entropy conserved results in physical errors from nonequilibrium phase transitions but minimizes numerical errors because solutions are analytic at each height. In contrast, computing CAPE with energy conserved avoids these physical errors, but accumulates numerical errors that are grid-resolution-dependent because the numerical integration of a differential equation is required. Analysis of CAPE computed with large databases of soundings from the tropical Amazon and midlatitude storm environments shows that physical errors from the entropy method are typically 1%–3% as large as CAPE, which is comparable to the numerical errors from conserving energy with grid spacing of 25 and 250 m using explicit first-order and second-order integration schemes, respectively. Errors in entropy-based CAPE calculations are also insensitive to vertical grid spacing, in contrast to energy-based calculations whose error strongly scales with the grid spacing. It is shown that entropy-based methods are advantageous when intercomparing datasets with differing vertical resolution because they produce accurate and reasonably fast results that are insensitive to grid resolution, whereas a second-order energy-based method is advantageous when analyzing data with a consistent vertical resolution because of its superior computational efficiency. Significance Statement Convective available potential energy (CAPE) is a measure of instability in the atmosphere that helps forecasters and researchers understand when and where thunderstorms will form. The purpose of this article is to identify the most efficient and accurate methods for computing CAPE. Two methods are considered here, one that relates to the entropy (a measure of thermodynamic disorder) of an air parcel and one that relates to the energy of an air parcel. Results indicate that the entropy method is most accurate and insensitive to the resolution of the data used for the calculation (which can vary considerably), whereas the energy method uses the least computation time.

Peters, John M.↗