Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Multiplexed Readout for an Experiment with a Large Number of Channels Using Single-Electron Sensitivity Skipper-CCDs

This paper presents the implementation of a multiplexed analog readout electronics system that can achieve single-electron counting using Skipper-CCDs with non-destructive readout. The proposed system allows the best performance of the sensors to be maintained, with sub-electron noise-level operation, while maintaining low-bandwidth data transfer, a minimum number of analog-to-digital converters (ADC) and low disk storage requirement with zero added multiplexing time, even for the simultaneous operation of thousands of channels. These features are possible with a combination of analog charge pile-up, sample and hold circuits and analog multiplexing. The implementation also aims to use the minimum number of components in circuits to keep compatibility with high-channel-density experiments using Skipper-CCDs for low-threshold particle detection applications. Performance details and experimental results using a sensor with 16 output stages are presented along with a review of the circuit design considerations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensing performance of sub-100-nm vanadium oxide films for room temperature thermal detection applications

Vanadium oxide films are widely employed as thermal detectors in uncooled infrared detection systems due to their high temperature coefficient of resistance near room temperature. One strategy toward maximizing detectivity and reducing the thermal time constant in these systems is to minimize the system platform dimensions. This approach necessitates thinner film thicknesses ([Formula: see text]100 nm), for which there is little information regarding thermal sensing performance. Herein, we report on the sensitivity of reactively sputtered vanadium oxide thin film resistive thermometers nominally ranging from 100 to 25 nm and assess the influence of thermal annealing. Here we demonstrate that films in this minimum limit of thickness maintain a high temperature coefficient while additionally providing an enhancement in characteristics of the noise equivalent power.

36 MATERIALS SCIENCE↗

Multidimensional four-wave-mixing spectroscopy with squeezed light

A set of nonlinear spectroscopic measurements with quantum light is presented here. It involves a strong pump with frequency ω pu and a weak probe atω pr interacting with a solid state target to generate a conjugated beam ω c =2ω pu -ω pr via nondegenerate four-wave mixing. The $\chi^{(3)}$ susceptibility can be measured by the noise spectra of the intensity difference of the squeezed beams. We discuss three spectroscopic setups based on squeezed light: first, single four-wave mixing in a single crystal; second, cascading scheme involving two crystals; third, an $\textit{SU}$(1, 1) interferometer based on two separate four-wave mixing processes. We further investigate the microscopic noise and optical losses in all three setups. Simulations are presented for silicon-vacancy color centers in diamond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel 2D velocity estimation method for large transient events in plasmas

Dynamics of fast transient events are challenging to be analyzed with high time resolution. Such events can occur in fusion plasmas such as the filaments during edge-localized modes (ELMs). Here, we present a robust method—the spatial displacement estimation—for estimating the displacements of structures with fast dynamics from high spatial and time resolution imaging diagnostics [e.g., gas-puff imaging (GPI)] with sampling time temporal resolution. First, a background suppression method is shown, which suppresses the slowly time-evolving and spatially non-uniform background in the signal. In the second step, a two-dimensional polynomial trend subtraction method is presented to tackle the remaining polynomial order trend in the signal. After performing these pre-processing steps, the spatial displacement of the propagating structure is estimated from the two-dimensional spatial cross-correlation coefficient function calculated between consecutive frames. The method is tested for its robustness and accuracy by simulated Gaussian events and spatially displaced random noise. An example application of the method is presented on propagating ELM filaments measured by the GPI system on the National Spherical Torus Experiment spherical tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-frequency noise characteristics of GaN vertical PIN diodes—Effects of design, current, and temperature

We report low-frequency noise characteristics of vertical GaN PIN diodes, focusing on the effects of the diode design, current, and temperature. The as-grown and regrown diodes, with and without surface treatment, have been studied. The noise in most of the GaN devices had a characteristic 1/f spectrum at high and moderate currents, while some devices revealed generation-recombination bulges at low currents (f is the frequency). The predominant trend of the noise spectral density, S I , dependence on the current was S I ~ I. All tested GaN PIN diodes had rather low normalized noise spectral densities of 10 –18 –10 –16 cm 2 /Hz (f = 10 Hz) at the current density J = 1 A/cm 2 at room temperature. The noise temperature dependences at different currents revealed peaks at T = 375–400 K. Temperature, current, and frequency dependences of noise suggest that the noise mechanism is of the recombination origin. Here, we argue that the noise measurements at low currents can be used to efficiently assess the quality of GaN PIN diodes.

36 MATERIALS SCIENCE↗

Density reconstruction in convergent high-energy-density systems using x-ray radiography and Bayesian inference

X-ray radiography is a technique frequently used to diagnose convergent high-energy-density (HED) systems, such as inertial confinement fusion implosion, and provides unique information that is not available through self-emission measurements. In this work, we investigate the scope and limits of that information using a radiography simulation combined with the Bayesian inference workflow. The accuracy of density reconstruction from simulated radiographs of spherical implosions driven with 27 kJ laser energy is assessed, including the increase or decrease in accuracy due to the addition of Lagrangian marker layers, Poisson noise, and improved prior information. This work is the first to present the full uncertainty distributions inferred from radiography analysis in HED systems and demonstrates the importance of constructing the full posterior probability density, as opposed to a point estimate, due to the modal structure of the likelihood surface introduced by typical experimental noise sources. This general methodology can be used both for robust analysis of radiographic data and for an improved design of radiography experiments by modeling the full experimental system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of ion velocity distributions in a large scale laser-produced plasma

Laser-produced plasma velocity distributions are an important, but difficult quantity to measure. In this work, we present a noninvasive technique for measuring individual charge state velocity distributions of laser-produced plasmas using a high temporal and spectral resolution monochromator. The novel application of this technique is its ability to detect particles up to seven meters from their inception (significantly larger than most laboratory plasma astrophysics experiments, which take place at or below the millimeter scale). The design and assembly of this diagnostic is discussed in terms of maximizing the signal to noise ratio, maximizing the spatial and temporal resolution, and other potential use cases. The analysis and results of this diagnostic are demonstrated by directly measuring the time-of-flight velocity of all ion charge states in a laser produced carbon plasma.

47 OTHER INSTRUMENTATION↗

An exploration of anomalous electrical noise in shocked cyclotrimethylenetrinitramine (RDX)-based explosives

Gas gun shock experiments on cyclotrimethylenetrinitramine (RDX)-based explosive compositions that employ embedded gauge particle velocity tracers have noted a significant amount of electrical noise when compared to other explosive formulations. This paper reexamines previously published embedded gauge data on Cyclotols (60–80 wt. % RDX) to quantify the electromagnetic behavior of these materials. The primary observation is a fourfold increase in the electrical noise when Cyclotols are shocked above 4.22 ± 0.08 GPa. Electromagnetic gauge noise is also observed within particle velocity traces in reactive growth and off-Hugoniot shocks, although at higher pressures than the direct shock case, suggesting a temperature- or kinetically dependent transition. In all cases, the electrical noise disappears upon detonation. By comparing with the static high-pressure phase diagram of RDX, we interpret this change in electromagnetic behavior to be a change in the RDX crystal structure to a piezoelectric phase, although it is uncertain whether the γ or ε phase is responsible for the observed behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radio frequency electrical resistance measurement under destructive pulsed magnetic fields

We developed a resistance measurement using radio frequency reflection to investigate the electrical transport characteristics under destructive pulsed magnetic fields above 100 T. A sample stage consisting of a homemade flexible printed circuit reduced the noise caused by the induced voltage from the pulsed magnetic fields, improving the accuracy of the measurements of the reflected waves. From the obtained reflectance data, the absolute value of the magnetoresistance was successfully determined by analyzing the phase with admittance charts. In conclusion, these developments enable more accurate and comprehensive measurements of electrical resistance in pulsed magnetic fields.

47 OTHER INSTRUMENTATION↗

Accurate numerical simulations of open quantum systems using spectral tensor trains

Decoherence between qubits is a major bottleneck in quantum computations. Decoherence results from intrinsic quantum and thermal fluctuations as well as noise in the external fields that perform the measurement and preparation processes. With prescribed colored noise spectra for intrinsic and extrinsic noise, we present a numerical method, Quantum Accelerated Stochastic Propagator Evaluation (Q-ASPEN), to solve the time-dependent noise-averaged reduced density matrix in the presence of intrinsic and extrinsic noise. Q-ASPEN is arbitrarily accurate and can be applied to provide estimates for the resources needed to error-correct quantum computations. We employ spectral tensor trains, which combine the advantages of tensor networks and pseudospectral methods, as a variational ansatz to the quantum relaxation problem and optimize the ansatz using methods typically used to train neural networks. Here, the spectral tensor trains in Q-ASPEN make accurate calculations with tens of quantum levels feasible. We present benchmarks for Q-ASPEN on the spin-boson model in the presence of intrinsic noise and on a quantum chain of up to 32 sites in the presence of extrinsic noise. In our benchmark, the memory cost of Q-ASPEN scales as a low-order polynomial in the size of the system once the number of system states surpasses the number of basis functions used in the spectral expansion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A practical approach to calculating magnetic Johnson noise for precision measurements

Magnetic Johnson noise is an important consideration for many applications involving precision magnetometry, and its significance will only increase in the future with improvements in measurement sensitivity. The fluctuation–dissipation theorem can be utilized to derive analytic expressions for magnetic Johnson noise in certain situations, but when used in conjunction with finite element analysis tools, the combined approach is particularly powerful as it provides a practical means to calculate the magnetic Johnson noise arising from conductors of arbitrary geometry and permeability. In this paper, we demonstrate this method to be one of the most comprehensive approaches presently available to calculate thermal magnetic noise. In particular, its applicability is shown to not be limited to cases where the noise is evaluated at a point in space but also can be expanded to include cases where the magnetic field detector has a more general shape, such as a finite-size loop, a gradiometer, or a detector that consists of a polarized atomic species trapped in a volume. Furthermore, some physics insights gained through studies made using this method are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Nernst–Ettingshausen effect in thin Pt and W films at low temperatures

As spin caloritronic measurements become increasingly common techniques for characterizing material properties, it is important to quantify potentially confounding effects. We report measurements of the Nernst–Ettingshausen response from room temperature to 5 K in thin film wires of Pt and W, metals commonly used as inverse spin Hall detectors in spin Seebeck characterization. Johnson–Nyquist noise thermometry is used to assess the temperature change in the metals with heater power at low temperatures, and the thermal path is analyzed via finite-element modeling. The Nernst–Ettingshausen response of W is found to be approximately temperature-independent, while the response of Pt increases at low temperatures. Furthermore, these results are discussed in the context of theoretical expectations and the possible role of magnetic impurities in Pt.

36 MATERIALS SCIENCE↗

Optimizing time integration for accurate recovery of shockwave interface location in radiography

We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.

Bremsstrahlung↗

Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors

In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sources of error and methods to improve accuracy in interface state density analysis using quasi-static capacitance–voltage measurements in wide bandgap semiconductors

Characterizing interface trap states in commercial wide bandgap devices using frequency-based measurements requires unconventionally high probing frequencies to account for both fast and slow traps associated with wide bandgap materials. The C - ψs technique has been suggested as a viable quasi-static method for determining the interface trap state densities in wide bandgap systems, but the results are shown to be susceptible to errors in the analysis procedure. Here this work explores the primary sources of errors present in the C - ψs technique using an analytical model that describes the apparent response for wide bandgap MOS capacitor devices. Measurement noise is shown to greatly impact the linear fitting routine of the 1/C$^{*2}_s$ vs Ψ s plot to calibrate the additive constant in the surface potential/gate voltage relationship, and an inexact knowledge of the oxide capacitance is also shown to impede interface trap state analysis near the band edge. In addition, a slight nonlinearity that is typically present throughout the 1/C$^{*2}_s$ vs Ψ s plot hinders the accurate estimation of interface trap densities, which is demonstrated for a fabricated n-SiC MOS capacitor device. Methods are suggested to improve quasi-static analysis, including a novel method to determine an approximate integration constant without relying on a linear fitting routine.

42 ENGINEERING↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗