Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Report of the sensor readout electronics panel

The findings of the Sensor Readout Electronics Panel are summarized in regard to technology assessment and recommended development plans. In addition to two specific readout issues, cryogenic readouts and sub-electron noise, the panel considered three advanced technology areas that impact the ability to achieve large format sensor arrays. These are mega-pixel focal plane packaging issues, focal plane to data processing module interfaces, and event driven readout architectures. Development in each of these five areas was judged to have significant impact in enabling the sensor performance desired for the Astrotech 21 mission set. Other readout issues, such as focal plane signal processing or other high volume data acquisition applications important for Eos-type mapping, were determined not to be relevant for astrophysics science goals.

Fossum, Eric R.↗

A 6 degree-of-freedom Lorentz force vibration isolator with nonlinear controller

This program demonstrated the technical feasibility of constructing large-stroke magnetic suspensions that can meet the active vibration isolation requirements of Space Station. These requirements include: (1) strokes over 1 cm in all directions, (2) actuator bandwidths over 100 Hz, (3) isolator roll-off frequencies below 10(exp -2) Hertz, and (4) force capability over 1 Newton in all axes. The 100 Hz actuator bandwidth allows the suspension to reject any direct force disturbances that act on the microgravity experiment, for example forces created by cable connections. The low isolator roll-off frequency and large stroke allow the magnetic suspension to isolate the microgravity experiment from Space Station vibrations above the roll-off frequency. The capability to meet these requirements was demonstrated by designing, constructing and testing a six-degree-of-freedom, prototype magnetic suspension system that featured high-performance, Lorentz-force actuators and full multi-input, multi-output control. This prototype suspension is designed to isolate large orbiter locker experiments under typical spacecraft constraints of size, weight, and power. Suspension in the full six-degrees-of-freedom was successfully demonstrated in this program while using a gravity-force unload mechanism to simulate a space environment. The prototype isolator is capable of space-based isolation service with relatively minor modification. The use of advanced, nonlinear control algorithms were investigated on a specially designed single-degree-of-freedom testbed. This low acceleration test facility simulates the Space Station vibration isolation problem in a single horizontal axis with low-friction, air-slide support. This allowed testing at the desired microgravity levels, without the gravity bias effects that are seen in a full six-degrees-of-freedom suspension. Precision components were used to reduce residual accelerations to microgravity levels so that the effects of sensor, actuator, and electronic noise could be evaluated. During the Phase 2 program, this testbed was used to demonstrate the advantages of nonlinear control algorithms to provide increased vibration isolation performance.

Fenn, Ralph↗

Analyses of On-orbit Determinations of the Clouds and the Earth Radiant Energy System (CERES) Thermistor Bolometer Sensor Zero-radiance Effects

The Clouds and Earth's Radiant Energy System (CERES) missions were designed to measure broadband earth-reflected shortwave solar (0.3 micrometers to less than 5.0 micrometers) and earth-emitted longwave (5.0 micrometers to greater than 100 micrometers) radiances as well as earth-emitted narrow-band radiances in the water vapor window region between 8 micrometers and 12 micrometers. However, the CERES scanning thermistor bolometer sensor zero-radiance offsets were found to vary as much as 1.0 Wm (exp -2) sr (exp -1) with the scan angle measurement geometry due to gravitational forces and systematic electronic noise. To minimize the gravitational effects, the Tropical Rainfall Measuring Mission (TRMM) Spacecraft CERES sensors' offsets were derived on-orbit as functions of scan elevation and azimuth angles from the January 7-8, 1998 radiometric observations of deep cold space, representative of a 3 K blackbody. In this paper, the TRMM/CERES six orbit data base of on-orbit derived offsets is presented and analyzed to define the sampling requirements for the CERES sensors located on the Earth Science Enterprise (ESE) Terra Spacecraft and on the Earth Observing System (EOS) Afternoon (PM-1) Spacecraft, scheduled for launches in 1999 and 2000, respectively. Analyses of the TRMM/CERES shortwave sensor earth radiance measurements indicate that offsets can be determined on-orbit at the plus or minus 0.02 Wm (exp -2) sr (exp -1) precision level. Offset measuring techniques and sampling requirements are discussed for the TRMM and ESE missions. Ground, pre-launch Terra CERES cross-track scan offsets are presented and described which were measured as a function of scan angle.

Lee, Robert B., III↗

Aerosol Profile Retrievals from Integrated Dual Wavelengths Space Lidar ESSP3-CENA and Spectral Radiance MODIS Data

The ESSP3-CENA space mission (formally PICASSO-CENA) will provide continues global observations with a two wavelength lidar. The attenuated backscattering coefficients measured by the lidar, have valuable information about the vertical distribution of aerosol particles and their sizes. However the information cannot be mapped into unique aerosol physical properties. Infinite number of physical solutions with different attenuations through the atmosphere can reconstruct the same two wavelength backscattered profile measured from space. Spectral radiance measured by MODIS simultaneously with the ESSP3 data can constrain the problem and resolve this ambiguity to a large extent. Sensitivity study shows that inversion of the integrated MODIS+ESSP3 data can derive the vertical profiles of the fine and coarse modes mixed in the same atmospheric column in the presence of moderate calibration uncertainties and electronic noise (approx. 10%). We shall present the sensitivity study and results from application of the technique to measurements in the SAFARI-2000 and SHADE experiments.

Kaufman, Yoram↗

Results From Cs Activated GaN Photocathode Development for MCP Detector Systems at GSFC

We describe the development of high quantum efficiency W photocathodes for use in large area two dimensional microchannel plate based detector arrays to enable new W space astronomy missions. Future W missions will require improvements in detector sensitivity, which has the most leverage for cost-effective improvements in overall telescope/instrument sensitivity. We use new materials such as p-doped GaN, AIGaN, ZnMgO, Sic and diamond. We have currently obtained QE values > 40 % at 185 nm with Cesiated GaN, and hope to demonstrate higher values in the future. By using controlled internal fields and nano-structuring of the surfaces, we plan to provide field emission assistance for photoelectrons while maintaining their energy distinction from dark noise electrons. We will transfer these methods from GaN to ZnMgO, a new family of wide band-gap materials more compatible with microchannel plates. We also are exploring technical parameters such as doping profiles, internal and external field strengths, angle of incidence, field emission assistance, surface preparation, etc.

Norton, Tim↗

On-Wafer Measurement of a Silicon-Based CMOS VCO at 324 GHz

The world s first silicon-based complementary metal oxide/semiconductor (CMOS) integrated-circuit voltage-controlled oscillator (VCO) operating in a frequency range around 324 GHz has been built and tested. Concomitantly, equipment for measuring the performance of this oscillator has been built and tested. These accomplishments are intermediate steps in a continuing effort to develop low-power-consumption, low-phase-noise, electronically tunable signal generators as local oscillators for heterodyne receivers in submillimeter-wavelength (frequency > 300 GHz) scientific instruments and imaging systems. Submillimeter-wavelength imaging systems are of special interest for military and law-enforcement use because they could, potentially, be used to detect weapons hidden behind clothing and other opaque dielectric materials. In comparison with prior submillimeter- wavelength signal generators, CMOS VCOs offer significant potential advantages, including great reductions in power consumption, mass, size, and complexity. In addition, there is potential for on-chip integration of CMOS VCOs with other CMOS integrated circuitry, including phase-lock loops, analog- to-digital converters, and advanced microprocessors.

Samoska, Lorene↗

Phytoplankton-Fluorescence-Lifetime Vertical Profiler

A battery-operated optoelectronic instrument is designed to be lowered into the ocean to measure the intensity and lifetime of fluorescence of chlorophyll A in marine phytoplankton as a function of depth from 0 to 300 m. Fluorescence lifetimes are especially useful as robust measures of photosynthetic productivity of phytoplankton and of physical and chemical mechanisms that affect photosynthesis. The knowledge of photosynthesis in phytoplankton gained by use of this and related instruments is expected to contribute to understanding of global processes that control the time-varying fluxes of carbon and associated biogenic elements in the ocean. The concentration of chlorophyll in the ocean presents a major detection challenge because in order to obtain accurate values of photosynthetic parameters, the intensity of light used to excite fluorescence must be kept very low so as not to disturb the photosynthetic system. Several innovations in fluorometric instrumentation were made in order to make it possible to reach the required low detection limit. These innovations include a highly efficient optical assembly with an integrated flow-through sample interface, and a high-gain, low-noise electronic detection subsystem. The instrument also incorporates means for self-calibration during operation, and electronic hardware and software for control, acquisition and analysis of data, and communications. The electronic circuitry is highly miniaturized and designed to minimize power demand. The instrument is housed in a package that can withstand the water pressure at the maximum depth of 300 m. A light-emitting diode excites fluorescence in the sample flow cell, which is placed at one focal point of an ellipsoidal reflector. A photomultiplier tube is placed at the other focal point. This optical arrangement enables highly efficient collection of fluorescence emitted over all polar directions. Fluorescence lifetime is measured indirectly, by use of a technique based on the same principle as the one described in "Fluorometer for Analysis of Photosynthesis in Phytoplankton" (SSC-00110), NASA Tech Briefs, Vol. 24, No. 1 (November 2000), page 79. The excitation is modulated at a frequency of 70 MHz, and the phase shift between the excitation light and the emitted fluorescence is measured by a detection method in which the 70 MHz signal is down-converted to a 400 Hz signal. The fluorescence lifetime can be computed from the known relationship among the fluorescence lifetime, phase shift, and modulation frequency

Fernandez, Salvador M.↗

Making Precise Resonators for Mesoscale Vibratory Gyroscopes

An alternative approach to the design and fabrication of vibratory gyroscopes is founded on the use of fabrication techniques that yield best results in the mesoscopic size range, which is characterized by overall device dimensions of the order of a centimeter. This approach stands in contradistinction to prior approaches in (1) the macroscopic size range (the size range of conventional design and fabrication, characterized by overall device dimensions of many centimeters) and (2) the microscopic size range [the size range of microelectromechanical systems (MEMS), characterized by overall device dimensions of the order of a millimeter or less]. The mesoscale approach offers some of the advantage of the MEMS approach (sizes and power demands smaller than those of the macroscale approach) and some of the advantage of the macroscale approach (the possibility of achieving relative dimensional precision greater than that of the MEMS approach). Relative dimensional precision is a major issue in the operation of a vibratory gyroscope. The heart of a vibratory gyroscope is a mechanical resonator that is required to have a specified symmetry in a plane orthogonal to the axis about which rotation is to be measured. If the resonator could be perfectly symmetrical, then in the absence of rotation, a free vibration of the resonator could remain fixed along any orientation relative to its housing; that is, the gyroscope could exhibit zero drift. In practice, manufacturing imprecision gives rise to some asymmetry in mass, flexural stiffness or dissipation, resulting in a slight drift or beating motion of an initial vibration pattern that cannot be distinguished from rotation. In the mesoscale approach, one exploits the following concepts: For a given amount of dimensional error generated in manufacturing, the asymmetry and hence the rate-of-rotation drift of the gyroscope can be reduced by increasing the scale. The decrease in asymmetry also reduces coupling of vibrations to the external environment. Mechanical thermal noise and electronic measurement noise and drift can also be reduced by increasing the size of the resonator and its associated sensors.

Yang, Eui-Hyeok↗

High-Fidelity Flash Lidar Model Development

NASA's Autonomous Landing and Hazard Avoidance Technologies (ALHAT) project is currently developing the critical technologies to safely and precisely navigate and land crew, cargo and robotic spacecraft vehicles on and around planetary bodies. One key element of this project is a high-fidelity Flash Lidar sensor that can generate three-dimensional (3-D) images of the planetary surface. These images are processed with hazard detection and avoidance and hazard relative navigation algorithms, and then are subsequently used by the Guidance, Navigation and Control subsystem to generate an optimal navigation solution. A complex, high-fidelity model of the Flash Lidar was developed in order to evaluate the performance of the sensor and its interaction with the interfacing ALHAT components on vehicles with different configurations and under different flight trajectories. The model contains a parameterized, general approach to Flash Lidar detection and reflects physical attributes such as range and electronic noise sources, and laser pulse temporal and spatial profiles. It also provides the realistic interaction of the laser pulse with terrain features that include varying albedo, boulders, craters slopes and shadows. This paper gives a description of the Flash Lidar model and presents results from the Lidar operating under different scenarios.

Hines, Glenn D.↗

Fine-Scale Fluctuations in the Corona Observed with Hi-C

The High Resolution Coronal Imager(HiC) flew aboard a NASA sounding rocket on 2012 July11 and captured roughly 345 s of high spatial and temporal resolution images of the solar corona in a narrowband 193 Angstrom channel. We have analyzed the fluctuations in intensity of Active Region11520.We selected events based on a lifetime greater than 11s (twoHiC frames)and intensities greater than a threshold determined from the average background intensity in a pixel and the photon and electronic noise. We find fluctuations occurring down to the smallest timescale(~11s).Typical intensity fluctuations are 20% background intensity, while some events peaka t100%the background intensity.Generally the fluctuations are clustered in solar structures, particularly the moss.We interpret the fluctuations in the moss as indicative of heating events. We use the observed events to model the active region core.

Winebarger, Amy↗

Event Selection and Background Rejection in Time Projection Chambers Using Convolutional Neural Networks and a Specific Application to the AdEPT Gamma-ray Polarimeter Mission

The Advanced Energetic Pair Telescope gamma-ray polarimeter uses a time projection chamber for measuring pair production events and is expected to generate a raw instrument data rate four orders of magnitude greater than is transmittable with typical satellite data communications. GammaNet, a convolutional neural network, proposes to solve this problem by performing event classification on-board for pair production and background events, reducing the data rate to a level that can be accommodated by typical satellite communication systems. In order to train GammaNet, a set of 1.1 × 10(exp 6) pair production events and 10(exp 6) background events were simulated for the Advanced Energetic Pair Telescope using the Geant4 Monte Carlo code. An additional set of 10(exp 6) pair production and 10 background events were simulated to test GammaNet’s capability for background discrimination. With optimization, GammaNet has achieved the proposed background rejection requirements for Galactic Cosmic Ray proton events. Given the best case assumption for downlink speeds, signal sensitivity for pair production ranged between 1.1 ± 0.5% to 69 ± 2% for 5 and 250 MeV incident gamma rays. This range became 0.1 ± 0.1% to 17 ± 2% for the worst case scenario of downlink speeds. The application of a feature visualization algorithm to GammaNet demonstrated decreased response to electronic noise and events exiting or entering the frame and increased response to parallel tracks that are close in proximity. GammaNet has been successfully implemented and shows promising results.

Richard L. Garnett↗

Methods for Passive Optical Detection and Relative Navigation for Rendezvous with a Non-Cooperative Object at Mars

Long-range passive optical detection of an orbiting inert sphere by a robotic Mars orbiter is investigated and trades are described in terms of detectability via reflected visible light in the presence of orbit uncertainty, gravitational perturbations, and camera electronics noise. A new approximate equation for signal-tonoise ratio (SNR) is developed to include most relevant camera imperfections, diffraction, and stray light from the Mars limb as relevant to this scenario. Using this method, a notional camera suite is designed to meet detection, navigation, and redundancy requirements for an example mission scenario. Results from a simulation tool demonstrate the long-range initial detection strategy in the presence of perturbations from various sources. Finally, navigation analysis shows that the information gathered using passive optical detection is sufficient to begin orbit matching.

Woolley, Ryan C.↗

High Contrast Imaging With MEMS Deformable Mirrors in the Decadal Survey Testbed

Deformable mirrors (DMs) are an essential part of any coronagraphic, high contrast instrument. They mitigate optical aberrations in the system and can even be used to generate contrast for the coronagraph. MEMS DMs from Boston Micromachines have been selected as the baseline for two flagship space telescopes proposed to the 2020 Decadal Survey. Although MEMS DMs have over a decade of heritage on ground-based telescopes and in in-air testbeds around the globe, they have not been tested in vacuum down to the ∼10−10 contrast level needed to image terrestrial exoplanets. In this paper, we describe vacuum tests of MEMS DMs in the Decadal Survey Testbed at the Jet Propulsion Laboratory. The first challenge was a bright, temporally incoherent signal, which was identified as electronics noise and removed with a low-pass filter. After that, the contrast has been limited in broadband light by the strong print-through on the DM surfaces. We performed numerical simulations to confirm that conclusion and to characterize the improvements needed to the MEMS DM surfaces and the testbed layout to attain our goal of 10−10 contrast.

Seo, Byoung-Joon↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

3D superconducting radio-frequency resonators for quantum computing

Superconducting radiofrequency (SRF) technology is being used not only in discovery science programs and basic research but also for several applications that benefit society more directly. The advantage of superconducting resonators over those made of normal-conducting metal is their ability to store electromagnetic energy with much lower dissipation. The high quality factor and longer dissipation time provided by these superconducting resonators can deliver superior performance. Currently, the quantum processing architecture uses resonators and interconnecting circuits operating in the microwave regime with superconducting strip-line technology and low noise electronic devices for switching and communication. The performance of these devices can be enhanced by embedding them in 3D SRF cavity resonators to prolong the coherence time, which improves the utility of the device by reducing error rates and allowing more manipulations (calculations) before the quantum state decays. In this presentation, I will review the current technology and progress towards the three dimensional SRF cavities to enhance the coherence time.

Dhakal, Pashupati↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105.This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Generation of high-frequency broadband electrostatic noise - The role of cold electrons

Broadband electrostatic noise (BEN) is commonly observed in the plasma sheet boundary layer in association with ion beams. The generation of these waves in a plasma consisting of an ion beam and a background of hot ions, hot electrons, and cold electrons is investigated. The cold electrons are of ionospheric origin. A complete, systematic study of electrostatic ion beam instabilities, including cold electrons, has been done, and it is shown that for the plasma configuration described, four instabilities can be excited: (1) ion acoustic, (2) Buneman, (3) beam resonant, and (4) electron acoustic instabilities. A low and high beam temperature division is shown to exist that separates when different instabilities can be excited. For typically observed parameters in the plasma sheet boundary layer, the ion beams lie in the high-temperature regime. In this regime, the beam resonant and electron acoustic instabilities are excited, and these instabilities can account for the high-frequency (higher than 500 Hz), low-power portion of the BEN spectrum. In the absence of cold electrons, no such wave growth occurs.

Schriver, David↗