Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A reduced model for the ITER divertor based on SOLPS solutions for ITER Q = 10 baseline conditions: B. A reduced model based on reversed-direction two point modeling

Edge codes such as SOLPS coupled to neutral codes such as EIRENE have become so comprehensive and sophisticated that they now constitute, in effect, 'code-experiments' that, as for actual experiments, can benefit from interpretation using simple models and conceptual frameworks, i.e. reduced models. The first task is the identification of options for the reduced model control parameters that are best suited for control of the action of the divertor, i.e. for control of target power loading and sputter–erosion, primarily. A strong correlation between the electron temperature at the divertor target, T e,t , and the neutral deuterium D 2 density at the target, n D2,t , flux-tube resolved, has recently been reported for a number of code studies including SOLPS-4.3 modeling of a set of ~50 ITER baseline cases: Q DT = 10, q 95 = 3, P SOL = 100 MW, metallic walls, and Ne seeding (Pitts et al 2019). Part A of the present study reports new results for largely the same ITER cases, confirming the strong correlation reported earlier between local values of T e,t , and (i) n D2,t , and (ii) normalized volumetric losses of power and pressure in the divertor. Strong correlations have now also been found, and are reported here for the first time, between T e,t and all of the divertor target quantities of practical interest. A physical explanation for this surprising result has not as yet been fully identified; nevertheless it has encouraging implications for reduced modeling of the ITER divertor. For such ITER conditions, (i) the global Ne injection rate, Inj Ne (Ne s –1 ), and (ii) the electron temperature at the location on the target where the peak power deposition occurs, T e,t @q ⊥,pk (eV), are found to be promising reduced model control parameters. In this part B, a reduced model for the ITER divertor is developed and described in detail, based on reversed-direction two point modeling, Rev2PM. The input to the reduced model is a value of the variable pair (T e,t @q ⊥,pk , Inj Ne )for a chosen case and the output are values of the various target as well as divertor-entrance quantities of practical interest, e.g. q ⊥,pk , the electron density at the X-point, n e,Xpt , etc. The reduced model was quantitatively characterized using one half of the code cases; it was then used to successfully predict (replicate) the code values of e.g. n e,Xpt for the other half.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pressure Response Optimization of an Eddy Current-Driven Flyer Plate Valve for the ITER Shattered Pellet Injection System

One technique for mitigating disruptions in a tokamak is shattered pellet injection (SPI). SPI is a process in which a large solid pellet consisting of deuterium, neon, or argon is desublimated in a pipe gun barsrel and launched downstream. Pellets are shattered just before entering the plasma by an impact with an angled tube. Injection of these materials into the plasma radiates stored thermal energy, limits current decay rates, suppresses the generation of runaway electrons, and dissipates runaway electrons if necessary. A critical element of the SPI system is a fast-acting valve that releases high-pressure gas to dislodge and accelerate pellets directly, or indirectly via a mechanical punch. A prototype valve sized for the ITER SPI system has been designed and fabricated. A pulsed high-voltage power supply energizes the valve’s internal magnetic coil, which induces eddy currents in the adjacent flyer plate resulting in a repulsive force between the flyer plate and the coil. The flyer plate action lifts a valve seat, allowing high-pressure gas to flow from the valve plenum to the downstream (breech) location of the pellet or mechanical punch. All of the valve’s internal components are designed to operate in ITER-level static background magnetic fields. Here, a study was conducted to optimize the downstream pressure response for a range of valve sizes and operating pressures. In particular, the study analyzes the breech pressure response associated with varying plenum pressures as well as varying breech volumes. A computational fluid dynamics simulation was built in STAR-CCM+ and validated against data from laboratory experiments. The resulting simulation outputs, in the form of downstream responses for a variety of initial plenum pressures and breech volumes, will be used as a complement to experimental data to ensure the pressure pulse is suitable for pellet survivability. These data, combined with studies on pellet shear strength and shock response, will be applied to optimization of overall operating parameters of the ITER SPI system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A High Voltage Distribution System for the Mu2e Electron Tracker

This paper describes the design and development of a High Voltage distribution system (Smart Switch - SS) which distributes one input high voltage (HV) into six High Voltage channels (HVDS) of a straw detector plane. The SS independently sets, controls, and monitors the HV to each individual channel of a straw-detector plane in the Mu2E Electron Tracking Detector. Each straw plane is composed of three 120 deg crescent-shaped panels, and each panel is composed of 96 straw-tube detectors. Each output channel of the SS has independent, ON-OFF, current and HV monitoring, as well as filtration, isolation, and a crowbar to provide overcurrent protection for in that channel. The inter-communication system is based on TCP/IP protocol using a Raspberry Pi. The HVDS meets all required specifications including long term stability, accurate monitoring of the HV and current, and overcurrent trip. The performance of the HVDS was found to be comparable to, if not better than, commercial HV power supplies.

42 ENGINEERING↗

Phase separation during the direct powder bed fusion of SiC

Powder bed fusion (PBF) is an attractive additive manufacturing option for fabrication of SiC object with complex geometries. However, the density and microstructure controls remain a challenge. This study is aimed at understanding laser–SiC interactions, with emphasis on microstructure-processing relationships, to identify potential solutions for the process improvement. SiC tubes were fabricated by PBF of pure SiC powders without sintering additives. Further, comprehensive analysis by X-ray diffraction, Raman spectroscopy, and electron microscopy indicated that binding of SiC particles was achieved by incongruent melting of SiC to a Si/C mixture containing SiC micro- and nanocrystallites. The phase evolution under laser irradiation of SiC was explained by phase diagrams. This study uncovered the PBF SiC microstructure at different length scales and the relationship between the microstructure and the processing parameters.

36 MATERIALS SCIENCE↗

Low Mass Straw Tube Tracker for the Mu2e Experiment

The Mu2e Tracker is a state of the art low mass straw tube detector that will look for charged lepton flavor violation (CLFV) by measuring the position and the momentum of the monochromatic 105 MeV/c electron from the $\mu^- N\rightarrow e^- N$ neutrinoless electron conversion in the presence of aluminum nucleus. To achieve this goal, the tracker needs to have momentum resolution of less than 180 keV/c \cite{TDR} for the conversion electron spectrum. The tracker is still under construction with the joint effort of several institutes. This paper will detail technical information about the Mu2e tracker and show early cosmics data taken with a production tracker plane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metamaterial-Inspired Vacuum Electron Devices and Accelerators

Metamaterials (MTMs) are structured materials with subwavelength features that can be engineered to have some unique properties not found in nature, such as negative refractive index, reversed Doppler effect, and reversed Cherenkov radiation. Based on these novel MTMs, several important research groups have made great attempts to develop novel MTM-inspired vacuum electron devices (VEDs) and accelerators. Just as solid-state power devices are innovated by incessant emerging of new semiconductor materials, VEDs can also be inspired by MTMs to have very remarkable advantages, such as smaller size, higher power, higher efficiency, and/or larger gain relative to conventional VEDs, such as traveling-wave tubes, backward-wave oscillators, and klystrons. Similarly, relative to conventional accelerators, MTM-inspired accelerators have obvious advantages, such as smaller size and higher accelerating gradient. Furthermore, MTM-inspired devices have promising applications in areas such as radar, communication, electronic warfare, microwave heating, and imaging.

43 PARTICLE ACCELERATORS↗

Assessing Manufacturability of the Oxide Dispersion Strengthened (ODS) 14YWT Alloy Fuel Cladding Tube Using SolidStir™ Technology

The 14YWT (Fe–14Cr–3W–0.4Ti–0.3Y2O3 (wt.%)) alloy is a potential candidatematerial for fabricating fuel cladding tubes and other structural components to be used in next-generation advanced nuclear reactors. Due to inherent limitations of current processing routes, this research explored a new variant of friction stir processing, commercially referred to as SolidStir™ Extrusion (patent pending) technology from Enabled Engineering to consolidate and extrude 14YWT powder into a fuel cladding tube. Several single-layer and multiple-layer consolidation experiments were carried out in an Inconel 625 die to determine the suitable processing parameters for SolidStir™ extrusion of the 14YWT alloy cladding tube. With these processing parameters, a 16–18 mm long tube of the 14YWT alloy with no visible defects was successfully extruded using this novel technology. Microstructural characterization results obtained using optical microscopy, scanning electron microscopy, energy dispersive spectroscopy, electron backscatter diffraction, and transmission electron microscopy will be presented.

Advanced Materials and Manufacturing Technology↗

Graphite crystals in catalytically-graphitized glass-like carbon

Catalytic graphitization of glass-like carbon leads to enhanced growth of micro-sized graphitic crystals with unusual shapes of wires, filaments, tubes, rods, whiskers, and spirals. Similar particles with axial symmetry are also found in pure glass-like carbon heat-treated at high temperatures. Nonetheless, the presence of a graphitization catalyst, Si in this case, in the heat-treatment process supports the transformation of porous, disordered carbon structure towards the graphitic atomic order and the formation of manifold peculiar polyhedral wires and particles of geometry distinct from the plate-like shape typical for conventional graphite. In contrast to conventional carbon nanotubes and fibers, the graphene layers are stacked perpendicular to the tube axis, while the size of the most common tube fibers can reach up to 10 μm in diameter and 100 μm in length. X-ray diffraction, Raman spectroscopy, scanning and transmission electron microscopy, small-angle X-ray scattering combined with complementary techniques have been used to characterize the structure of the glass-like carbon derived from furfuryl alcohol catalytically-graphitized using Si particles at 3000 °C. Finally, since control of graphite shape is vital to achieving the level of performance required in contemporary applications, the obtained results demonstrate that the catalytic graphitization method may be employed to produce filamentous graphite crystals.

36 MATERIALS SCIENCE↗

Characterization and Evaluation of Scintillating Fiber System Components

Idaho National Laboratory is studying long scintillation fibers (SF) in a project called “TRIPWIRE” which aims to verify containment in inaccessible nuclear waste repositories. This system will continuously monitor ionizing radiation, electromagnetic fields, and seismic activity in the vicinity of nuclear waste. Previous experiments have determined a better alternative to long SF is to couple shorter SF to kilometer scale optical fiber (OF) to reach electronics far outside of the repository. Minor signal attenuation from coupling these fibers has been observed using optical spectrometry. This experiment characterized two photomultiplier tubes (PMT) to reduce this loss by matching their spectral response characteristics to the SF’s emission spectrum. The experiment created a comparison between the two PMTs showing results that suggest other characteristics are playing a major role in improving signal attenuation when the SF is coupled to OF.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si 3 N 4 ) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T e ) and density (n e ). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of ~1 μm thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n e ~ 10 9 cm –3 ) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. Here, we describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calorimeter calibration and performance for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the charged lepton flavour-violating conversion of a muon into an electron, aiming to reach a sensitivity of $R_{\mu e} \sim 10^{-17}$, an improvement of four orders of magnitude over previous limits. To reach this goal, Mu2e will use an intense pulsed muon beam and a detector system composed of a high-precision straw tube tracker and a pure CsI crystal calorimeter. The calorimeter plays a crucial role in the experiment, as it provides particle identification capabilities that are necessary for background suppression. To perform its tasks, the detector must achieve an energy resolution better than 10% and a timing resolution below 500 ps for 100 MeV electrons. Cosmic-ray data and laser pulses are used to equalize the response of each channel, to calibrate the energy scale and to monitor the system's stability over time. This poster reports on the calibration and analysis techniques developed to ensure that the calorimeter requirements for precise energy and time measurements are met. Results for the calorimeter performance obtained during the commissioning phase will be discussed, and an overview of the current status in the Mu2e experimental hall will be presented.

Salamino, Sabrina [Frascati]↗

Nozzle-Free Printing of CNT Electronics Using Laser-Generated Focused Ultrasound

Printed electronics have made remarkable progress in recent years and inkjet printing (IJP) has emerged as one of the leading methods for fabricating printed electronic devices. However, challenges such as nozzle clogging, and strict ink formulation constraints have limited their widespread use. To address this issue, a novel nozzle-free printing technology is explored, which is enabled by laser-generated focused ultrasound, as a potential alternative printing modality called Shock-wave Jet Printing (SJP). Specifically, the performance of SJP-printed and IJP-printed bottom-gated carbon nanotube (CNT) thin film transistors (TFTs) is compared. While IJP required ten print passes to achieve fully functional devices with channel dimensions ranging from tens to hundreds of micrometers, SJP achieved comparable performance with just a single pass. For optimized devices, SJP demonstrated six times higher maximum mobility than IJP-printed devices. Furthermore, the advantages of nozzle-free printing are evident, as SJP successfully printed stored and unsonicated inks, delivering moderate electrical performance, whereas IJP suffered from nozzle clogging due to CNT agglomeration. Moreover, SJP can print significantly longer CNTs, spanning the entire range of tube lengths of commercially available CNT ink. The findings from this study contribute to the advancement of nanomaterial printing, ink formulation, and the development of cost-effective printable electronics.

47 OTHER INSTRUMENTATION↗

The Mu2e experiment — Searching for charged lepton flavor violation

The Mu2e experiment will search for a Standard Model violating rate of neutrinoless conversion of a muon into an electron in the presence of an aluminum nucleus. Observation of this charged lepton flavor violating process would be an unambiguous sign of new physics. Mu2e will improve upon previous searches for this process by four orders of magnitude. This requires the world’s highest-intensity muon beam, a detector system capable of efficiently reconstructing the 105 MeV/c conversion electron signal, and minimizing sensitivity to background events. A pulsed 8 GeV proton beam strikes a target, producing pions that decay into muons. Beam outside the pulse must be suppressed to < 1 0 – 10 to reduce beam-related backgrounds. The muon beam is guided from the production target along the transport system and onto the aluminum stopping target. Conversion electrons leave the stopping target and propagate inside a solenoidal magnetic field to the tracker and electromagnetic calorimeter. The tracker is a system of straw tube panels filled with Ar/CO 2 at 1 atm that tracks particles inside of a solenoidal B-field and measures their momenta with ~ 100 keV/c resolution to resolve signal events from decay-in-orbit backgrounds. The CsI calorimeter provides E / p and is used to seed the track reconstruction algorithm with σ E / E ~ 10 % and σ t < 500 ps . Additionally, a novel cosmic ray veto with greater than 99.99% efficiency brings the expected number of background events to fewer than one over three years of running. Finally, to normalize the experiment, the stopping target monitor measures the rate of capture photons from muons incident on the stopping target by using a system of high-purity germanium and lanthanum bromide scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-State Welding of the Nanostructured Ferritic Alloy 14YWT Using a Capacitive Discharge Resistance Welding Technique

Joining nanostructured ferritic alloys (NFAs) has proved challenging, as the nano-oxides that provide superior strength, creep resistance, and radiation tolerance at high temperatures tend to agglomerate, redistribute, and coarsen during conventional fusion welding. In this study, capacitive discharge resistance welding (CDRW)—a solid-state variant of resistance welding—was used to join end caps and thin-walled cladding tubes of the NFA 14YWT. The resulting solid-state joints were found to be hermetically sealed and were characterized across the weld region using electron microscopy (macroscopic, microscopic, and nanometer scales) and nanoindentation. Microstructural evolution near the weld line was limited to narrow (~50–200 μm) thermo-mechanically affected zones (TMAZs) and to a reduction in pre-existing component textures. Dispersoid populations (i.e., nano-oxides and larger oxide particles) appeared unchanged by all but the highest energy and power CDRW condition, with this extreme producing only minor nano-oxide coarsening (~2 nm → ~5 nm Ø). Despite a minimal microstructural change, the TMAZs were found to be ~10% softer than the surrounding base material. These findings are considered in terms of past solid-state welding (SSW) efforts—cladding applications and NFA-like materials in particular—and in terms of strengthening mechanisms in NFAs and the potential impacts of localized temperature–strain conditions during SSW.

36 MATERIALS SCIENCE↗

Corrosion Behavior of a Reactive Bond Between Stainless Steel and a Cast AlCeMg Alloy

Corrosion is a longstanding issue for metal components, especially those used in heat exchanger applications. Al–Ce–Mg alloys may provide a potential solution to this problem due to their good mechanical properties and potential reaction bonding with other metals. The reaction bonding involves a “reactive” bond that occurs upon casting of Al–Ce–Mg alloy over stainless steel (SS). Here this study examined the corrosion response of Al–2Ce–6Mg (atomic percent)/(SS) reactive bond interfaces after samples were completely submerged in nitric, sulfuric, formic, and mixed acids for 267 h. Scanning electron microscopy revealed that in the as-cut condition, reactive bond formations were seen frequently throughout the length of the casting and maintained a secure bond between the alloy and the SS tubes. Furthermore, the nitric, sulfuric, and the mixed acids did not have a deleterious effect on the reactive bond structure. However, formic acid did produce changes in both the microstructural appearance and the elemental profile across the bond due to the formation of corrosion reaction products on the acid-exposed surface.

36 MATERIALS SCIENCE↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗