A solid state detector experiment for electron measurements on OGO-F.
Solid state detector system for electron measurements on OGO-F
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Solid state detector system for electron measurements on OGO-F
Ultraheavy cosmic rays have been measured by both passive and electronic detectors. These detectors are reviewed, and the requirements are given for the next major step in detector design.
The importance of Lead and Uranium group abundances in cosmic rays is discussed in understanding their evolution and propagation. The electronic detectors can provide good charge resolution but poor data statistics. The plastic detectors can provide somewhat better statistics but charge resolution deteriorates. The extraterrestrial crystals can provide good statistics but with poor charge resolution. Recent studies of extraterrestrial crystals regarding their calibration to accelerated uranium ion beam and track etch kinetics are discussed. It is hoped that a charge resolution of two charge units can be achieved provided an additional parameter is taken into account. The prospects to study abundances of Lead group, Uranium group and superheavy element in extraterrestrial crystals are discussed, and usefulness of these studies in the light of studies with electronic and plastic detectors is assessed.
Explore the source record for details and available documents.
A new microwave-enhanced synthesis method for the production of tellurium nanostructures is reported here—with control over products from the 1D regime (sub-5 nm diameter nanowires), to nanoribbons, to the 2D tellurene regime—along with a new methodology for local statistical quantification of the crystallographic parameters of these materials at the nanometer scale. Using a direct electron detector and image-corrected microscope, large and robust 4D scanning transmission electron microscopy datasets for accurate structural analysis are obtained. These datasets allow the adaptation of quantitative techniques originally developed for X-ray diffraction (XRD) refinement analyses to transmission electron microscopy, enabling the first demonstration of sub-picometer accuracy lattice parameter extraction while also obtaining both the size of the coherent crystallite domains and the nanostrain, which is observed to decrease as nanowires transition to tellurene. This new local analysis is commensurate with global powder XRD results, indicating the robustness of both the new synthesis approach and new structural analysis methodology for future scalable production of 2D tellurene and characterization of nanomaterials.
The Electron–Ion Collider (EIC) will be a novel experimental facility to explore the properties of gluons in nucleons and nuclei, shedding light on their structure and dynamics. The EIC community outlined the physics program of the EIC in a White Paper, and the demanding detector re quirements and potential technologies to deploy at an EIC detector were published in a comprehensive Yellow Report. The general-purpose detector resulting from these efforts, ePIC, is designed to perform a broad physics program. At the same time, the wider EIC community is strongly in favor of a second detector at the EIC. Having two general-purpose collider detec tors to support the EIC science program allows us to have cross-checks and control of systematic uncertainties for potential scientific discoveries. The second detector should feature complementary technologies where possible. It can also focus on specific measurements that are less well-addressed by ePIC. The second interaction region provides potentially improved forward detector acceptance at low pT and a secondary beam focus that enables to enhance the exclusive, tagging, and diffractive physics program. Hereby, I will present the potential capabilities of the second detector and discuss studies related to its diffractive physics program.
A sounding rocket-borne electron detector of high time resolution is used to search for modulation of auroral electron fluxes in the frequency range 50 kHz to 10 MHz and energy range 5-7 keV. Data were telemetered to ground via a 93-kHz subcarrier. A cross-correlation analysis of the data collected indicates low-level modulation near the detection threshold of the instrument. Two U-1 events are observed which are interpreted as indications of modulation. The two modulation events occur during a period of increasing flux for a region marking the boundary between two current sheets detected by the payload magnetometer. The strongest argument against interference contamination is the lack of any observable modulation at times other than those mentioned in the study.
Late in 1980, specifications were prepared for detail design definition of a six band solid state multispectral instrument having three visible (VIS), one near infrared (NIR), and two short wave infrared (SWIR) bands. This instrument concept, known as the Multispectral Linear Array (MLA), also offered increased spatial resolution, on board gain and offset correction, and additional operational modes which would allow for cross track and stereoscopic viewing as well as a multialtitude operational capability. A description is presented of a summary of some of the salient features of four different MLA design concepts, as developed by four American companies. The designs ranged from the use of multiple refractive telescopes utilizing three groups of focal plane detectors electronic correlation processing for achieving spatial registration, and incorporating palladium silicide (PdSi) SWIR detectors, to a four-mirror all-reflective telecentric system utilizing a beam splitter for spatial registration.
At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or other failures in those systems. In another type of envisioned application, chemochromic detectors of this type could be optoelectronically instrumented for monitoring to provide measured digital indications of color changes indicative of the presence of hydrogen.
Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.
Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-𝛽 decay detector (∼5 metric ton, 90% 136 Xe, 10% 134 Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY’s predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector’s efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5–8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.
Explore the source record for details and available documents.
To understand the dynamic structure–function relationship of soft- and biomolecules, the determination of the three-dimensional (3D) structure of each individual molecule (nonaveraged structure) in its native state is sought-after. Cryo-electron tomography (cryo-ET) is a unique tool for imaging an individual object from a series of tilted views. However, due to radiation damage from the incident electron beam, the tolerable electron dose limits image contrast and the signal-to-noise ratio (SNR) of the data, preventing the 3D structure determination of individual molecules, especially at high-resolution. Although recently developed technologies and techniques, such as the direct electron detector, phase plate, and computational algorithms, can partially improve image contrast/SNR at the same electron dose, the high-resolution structure, such as tertiary structure of individual molecules, has not yet been resolved. Here, we review the cryo-electron microscopy (cryo-EM) and cryo-ET experimental parameters to discuss how these parameters affect the extent of radiation damage. This discussion can guide us in optimizing the experimental strategy to increase the imaging dose or improve image SNR without increasing the radiation damage. With a higher dose, a higher image contrast/SNR can be achieved, which is crucial for individual-molecule 3D structure. With 3D structures determined from an ensemble of individual molecules in different conformations, the molecular mechanism through their biochemical reactions, such as self-folding or synthesis, can be elucidated in a straightforward manner.
Electronic image sensors based on charge coupled devices operated in electron-bombarded mode, yielding real-time, remote-readout, photon-limited UV imaging capability are being developed. The sensors also incorporate fast-focal-ratio Schmidt optics and opaque photocathodes, giving nearly the ultimate possible diffuse-source sensitivity. They can be used for direct imagery of atmospheric emission phenomena, and for imaging spectrography with moderate spatial and spectral resolution. The current state of instrument development, laboratory results, planned future developments and proposed applications of the sensors in space flight instrumentation is described.
This grant was originally awarded for the flight of the AMICIST sounding rocket. However, upon launch failure of the PHAZE rocket, additional resources were placed in this grant to cover the launch of the PHAZE II rocket. AMICIST was successfully launched from the Poker Flat Range on February 24, 1995, and the PHAZE II was successfully launched also from the Poker Flat Range on February 10, 1997. The major objective of the AMICIST flight was to investigate the bursts of transverse ion acceleration occurring during aurora, commonly known as Lower Hybrid Solitary Structures, with the flight of two scientific payloads to unravel space from time effects. The data clearly showed that the structures of ion acceleration were a spatial phenomena having a scale size transverse to the local magnetic field of about 100 m. On the other hand, structures in the auroral electrons were generally observed on this flight to be temporal features that occurred at the same time at the two payloads separated by a few kilometers. The primary objective of the PHAZE rocket flight was to further study the temporal features of auroral electron precipitation having many electron detectors, some fixed in energy, that could study the distribution function of the auroral electrons on time scales of a fraction of a millisecond. A important paper on this topic has just been submitted for publication which uses the PHAZE data to show that the potential structure (electric field parallel to the magnetic field) that accelerates the auroral electrons within one Earth radius of the ground, is not static, but rather fluctuates with frequencies close to the local proton and hydrogen gyrofrequencies. The fluctuation appears to be an actual turning on and off of the electric field at these frequencies. When the potential is turned off, ambient electrons can enter the region and be accelerated along B when the potential is on creating field- aligned bursts which manifest themselves as flickering aurora seen from the ground. The on/off model can explain many of the dynamic features of the aurora which have been unexplained since man first looked up at the visual display. Much needs to be done yet to understand how ions couple into this process.
Electron detectors on the Echo 7 active sounding rocket experiment measured 'conjugate echoes' resulting from artificial electron beam injections. Analysis of the drift motion of the electrons after a complete bounce leads to measurements of the magnetospheric convection electric field mapped to ionospheric altitudes. The magnetospheric field was highly variable, changing by tens of mV/m on time scales of as little as hundreds of millisec. While the smallest-scale magnetospheric field irregularities were mapped out by ionospheric conductivity, larger-scale features were enhanced by up to 50 mV/m in the ionosphere. The mismatch between magnetospheric and ionspheric convection fields indicates a violation of the equipotential field line condition. The parallel fields occurred in regions roughly 10 km across and probably supported a total potential drop of 10-100 V.
An arrangement for calibrating a photon detector particularly applicable for the ultraviolet and vacuum ultraviolet regions is based on electron photon coincidence utilizing crossed electron beam atom beam collisions. Atoms are excited by electrons which lose a known amount of energy and scatter with a known remaining energy, while the excited atoms emit photons of known radiation. Electrons of the known remaining energy are separated from other electrons and are counted. Photons emitted in a direction related to the particular direction of scattered electrons are detected to serve as a standard. Each of the electrons is used to initiate the measurements of a time interval which terminates with the arrival of a photon exciting the photon detector. Only the number of time intervals related to the coincidence correlation and of electrons scattered in the particular direction with the known remaining energy and photons of a particular radiation level emitted due to the collisions of such scattered electrons are counted. The detector calibration is related to the number of counted electrons and photons.
Relativistic electron precipitation spikes were observed in the quasi-trapped population at midlatitudes by an array of electron detectors aboard the low-altitude polar-orbiting satellite 1972-076B. The fluxes of electrons of energies not less than 4 MeV may undergo pronounced enhancements, while the intensities of electrons in the few hundred keV range may not be significantly affected. Energy spectra and pitch angle distributions were measured over the energy range 160 keV to 2.4 MeV with a combination of three spectrometers. Fluxes of energetic electrons (greater than 4 MeV) were measured with high sensitivity in each of two large plastic scintillator anticoincidence counters surrounding a germanium spectrometer.