Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electricity generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Task 12 PV Sustainability - Environmental Life Cycle Assessment of Residential PV and Battery Storage Systems

Using a life cycle assessment (LCA), the environmental impacts from generating 1 kWh of electricity for self-consumption via a photovoltaic-battery system are determined. The system includes a 10 kWp multicrystalline-silicon photovoltaic (PV) system (solar irradiation about 1350 kWh/m2/year and annual yield 1000 kWh/kWp), an iron phosphate lithium-ion (LiFePO4) battery, and other components such as the control system, battery housing, and two inverters (one for the PV system and one for the battery system). Three options for the AC-coupled system with changing battery capacities (5, 10, or 20 kWh nominal capacity) are investigated. The environmental impacts are assessed using the indicators greenhouse gas emissions and cumulative energy demand (separated into total and non-renewable cumulative energy demand). In addition, the four most important impact categories for PV electricity - respiratory inorganics (particulate matter), acidification, energy carrier resource use, and minerals and metals resource use - are assessed according to the environmental footprint (EF) method. Data are drawn from the DETEC data DQRv2:2018, recent literature, and product details provided by manufacturers. The results show larger environmental impacts of PV-battery systems with increasing battery capacity; for capacities of 5, 10, and 20 kWh, the cumulative greenhouse gas emissions from 1 kWh of electricity generation for self-consumption via a PV-battery system are 80, 84, and 88 g CO 2- eq/kWh, respectively. The cumulative greenhouse gas emissions of PV electricity consumed directly or fed into the grid are 54 g CO 2 -eq/kWh. The corresponding total cumulative energy demands are 5.27, 5.40, and 5.50 MJ oil-eq/kWh, with non-renewable energy carriers contributing 1.16, 1.22, and 1.29 MJ oil-eq/kWh. In the investigated EF impact categories, we similarly observe a larger environmental burden with increasing battery capacity, except in the use of minerals and metals. Our sensitivity analyses show that using a nickel cobalt manganese oxide (NCM) lithium-ion battery, instead of an LiFePO 4 battery, leads to a comparable environmental impact in terms of greenhouse gas emissions and cumulative energy demand. However, the NCM battery increases the impact in the EF categories of acidification and respiratory inorganics by 7 and 10%, respectively, whereas energy carrier resource use decreases by 4% and minerals and metals resource use decrease by 1%. Using a copper indium selenium (CIS) PV panel instead of a multicrystalline-silicon decreases greenhouse gas emissions by 24%, non-renewable cumulative energy demand by 13%, and particulate matter emissions by 60% (the largest decrease). Furthermore, the calculated environmental impacts are sensitive to the assumed battery lifetime. A decrease from 5000 to 3000 charge cycles increases non-renewable cumulative energy demand by 24% and greenhouse gas emissions by 16%. Increasing from 5000 to 7000 charge cycles decreases the environmental impacts by 6% and 7% in terms of non-renewable cumulative energy demand and greenhouse gas emissions, respectively. A utility-scale battery system case study shows that using batteries to store PV electricity overproduction reduces greenhouse gas emissions compared to using natural gas backup electricity generation.

14 SOLAR ENERGY↗

Assessment of the impacts of renewable energy variability in long-term decarbonization strategies

To meet the nationally determined contributions proposed by the countries that signed the Paris Agreement, investments must be made in renewable generation technologies such as solar and wind. However, due to their high variability, these technologies pose challenges in terms of meeting demand or generating excess electricity. For this reason, energy system models are designed to capture this variability by considering flexibility technologies. Nevertheless, it is important to note that some energy system models lack integration with other sectors. Therefore, integrated assessment models have been employed to evaluate mitigation strategies, as they endogenously consider the linkages between energy and non-energy sectors. In addition, due to their complexity, these models do not account for the variability of renewable resources. Hence, this research aims to address this issue. Here, this work represents the first attempt to evaluate how the introduction of hourly resolution affects the outcomes of integrated assessment models, specifically focusing on the Global Change Analysis Model (GCAM). We employ a soft-linking approach between the GCAM and the Highway to Renewable Energy Systems model (H2RES, an hourly level energy system model) to accomplish this. The proposed approach is tested using Chile’s Nationally Determined Contributions under different hydrological profiles in the power sector. The results show that it is possible to use the capacity obtained from the Global Change Analysis Model and implement it on an hourly scale. However, the feasibility of implementation depends on high levels of flexibility technologies, such as battery energy storage. When given the choice of investments in renewable sources and flexible technologies, the optimal dispatch of the H2RES model show small differences than those obtained by GCAM-Chile. H2RES differs from GCAM-Chile in approximately 5% for wind and 3% for solar electricity generation in the year 2050. However, feasible integration of significant renewable sources is obtained with relatively high Critical Excess Electricity Production levels, reaching 20% in 2050. This excess electricity is attributed to the necessity for flexible technologies to manage the intermittency of renewables sources when hourly profiles of such sources are considered.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

A Technical-Economic Assessment of Brackish Water Treatment for Fossil Power Plant Cooling with Reduced Environmental Impact

The power sector accounts for approximately 40% of freshwater use in the U.S. Reusing non-traditional water resources is critical for alleviating water stress in the western United States. The purpose of this study is to conduct a techno-economic system analysis to evaluate the potential of brackish water treatment for wet cooling towers at existing thermo-electric generating units (EGUs). It aims to address current knowledge gaps in support of non-traditional water resources planning and the electric power industry's water decision- and policy making. An engineering-economic model was developed and combined with DuPont's water application value engine (WAVE) v1.82 to evaluate the viability of retrofitting reverse osmosis-based brackish water treatment systems to individual existing EGUs and then aggregating the unit-level results to the fleet level. In the base case, brackish water treatment can reduce freshwater consumption of electric generation units by 94–100% while increasing the cost of electric generation by approximately 10% and have marginal impacts on the units' parasitic loads. When zero liquid discharge systems are applied to brackish water brine treatment, the cost of electric generation and freshwater consumption savings and energy penalty to the power plant significantly increase. These costs are even higher than dry cooling deployment in lieu of wet cooling towers. The choice of freshwater savings between brackish water desalination and dry cooling deployment depends greatly on how the concentrated brines are managed. Multiple factors must be considered when supporting decision-making in water management and planning in power sectors, which include non-traditional water quantity and quality as well as trade-offs among technical performance, economics, and environmental impacts.

Wu, Zitao↗

TEAMER: Biofouling Analysis for Wave Energy Piston Design - Load Cell Data

Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton has developed the concept of a biofouling mitigation seal as part of the piston sealing assembly for the Triton Wave Energy Converter (TSI-WEC). This mitigation seal has the purpose of preventing the formation of a biofilm on the inside of the piston cylinder. It is hypothesized that the prevention of a biofilm will reduce the amount of macro-biofouling that can occur in the piston assembly. The mitigation seal can also reduce the wear on the main dynamic seal, helping to maintain smooth operation and water-tightness. The cylinder is made from a thermoset composite epoxy, which is resistant to corrosion. However, no studies have researched the material's performance with biofouling. Triton placed two prototype Power Take-Off (PTO) assemblies in a PNNL biofouling tank, one with a biofouling mitigation seal and one without, allowing for an evaluation of seal effectiveness at the prevention of biofouling. In actual WEC operation, wave action would react against the piston, which would drive the linear actuator and electric generator, providing electrical power. In the test setup, this was reversed; a linear actuator was powered to drive the piston in a consistent motion within the cylinder. There are two assemblies: one has a biofouling mitigation seal, the other (control) does not. The following data encompasses a 4 month test period, with load cells being used to monitor piston friction force. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation. This project is part of the TEAMER RFTS 3 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Cyber-Attack Detection and Accommodation for the Energy Delivery System

The goals of this project were to create a software system with a suite of key algorithms for cyber-attack detection and accommodation providing domain layer protection for critical power generation assets. Example assets included gas and steam turbines, heat recovery steam generators, and electrical generators. The aggressive algorithm goals were aimed at reducing the false positive rates in threat detection to <1% using learnings from many evolving disciplines (power turbine and generator physics, power system modeling, modern control theory, system identification, machine learning, deep learning, mathematics and data science). Additional goals for the algorithms involved localizing threats on-the-fly to know in which monitoring node the effects of attacks are present, and then providing accommodation to keep the system running uninterrupted much of the time in the presence of the attack. Accommodation had a performance goal of providing resiliency when up to 50% of monitoring nodes are in an attack state.

cybersecurity, cyber-physical↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of Power Take-Off Architectures for Wave-Powered Reverse Osmosis Desalination of Seawater with Co-Production of Electricity

Several power take-off (PTO) architectures for wave-powered reverse osmosis (RO) desalination of seawater are introduced and compared based on the annual average freshwater production and the size of the components, which strongly relate to the costs of the system. The set of architectures compared includes a novel series-type PTO architecture not previously considered. These seawater hydraulic PTO architectures are composed of a WEC-driven pump, an RO module, an intake charge pump driven by an electric motor, and a hydraulic motor driving an electric generator for electric power production. This study is performed using an efficient two-way coupled steady-state model for the average performance of the system in a given sea state, including freshwater permeate production, electric power production, and electric power consumption. A multi-objective design problem is formulated for the purposes of this comparative study, with the objectives of maximizing annual freshwater production, minimizing the displacement of the WEC-driven pump, and minimizing the installed RO membrane area. This establishes a framework for comparison in the absence of a mature techno-economic model. The requirement that the system produces enough electric power to meet its consumption is applied as a constraint on the operation of the system. The oscillating wave surge converter Oyster 1 is assumed as the WEC. Weights on performance of the system in a given sea state are based on historical data from Humboldt Bay, CA. This study finds that (1) architectures in a series configuration allow for a reduction in the WEC-driven pump size of 59–92% compared to prior work, (2) varying the displacement of the WEC-driven pump between sea conditions does not provide any significant advantage in performance, and (3) varying the active RO membrane area between sea condition offers improvements between 7% and 41% in each design objective.

Energy & Fuels↗

Impacts of the Inflation Reduction Act on Consumer Energy Expenditures

The Inflation Reduction Act introduced or expanded a suite of federal tax credits for clean electricity generation and customer adoption of electric (and other highly efficient) end-use equipment. These incentives are expected to drive changes in both the electricity generation mix and demand for electricity (especially for space heating and light-duty vehicles), which are highly interconnected. In this session, Caitlin Murphy, Group Manager and Senior Analyst in NREL's Strategic Energy Analysis Center, will present findings from her team's recent state-level analysis on the combined effects of various IRA incentives on customer expenditures for electricity, natural gas, and gasoline. She will present and explain the regional variations observed in their analysis, based on interactions between end-use equipment cost and performance and projections for future energy prices.

air source heat pump↗

Waveform emission location determination systems and associated methods

Waveform emission location determination systems and associated methods are described. According to one aspect, a waveform emission location determination system includes a plurality of detectors configured to receive a waveform emitted by a source and to generate electrical signals corresponding to the waveform, processing circuitry configured to access data corresponding to the electrical signals generated by the detectors, use the data to determine a plurality of spheres, and wherein a surface of each of the spheres contains a location of the source when the waveform was emitted by the source, determine an intersection of the spheres, and use the intersection of the spheres to determine the location of the source when the waveform was emitted by the source.

Hughes, Michael S.↗

Innovative Technologies for a Low Carbon Electricity System

The electricity sector represents the centerpiece of decarbonization pathways for the state. Decrease in the cost of renewable electricity generation, combined with ample solar energy, wind and other renewable resources, presents a realistic way to achieve electricity generation that is nearly free of CO 2 emissions by mid-century. Expansion of renewable electricity supply could allow replacement of many CO 2 -emitting technologies with ones that use electricity—in transportation, buildings, and possibly industry. Key elements of the path for California’s electricity sector are: restrain electricity demand through higher efficiency, rapidly expand renewable electricity generation, develop electricity storage to complement renewable electricity, manage flexible electricity loads for a low-carbon electricity system, electrify where appropriate to reduce CO 2 emissions, and maintain reliable and resilient electricity supply. This report provides an overview of a multitude of innovative technologies in each of the above areas that have the potential to help the state meet its decarbonization goals, while lowering costs and promoting greater reliability. The information presented provides a portrait of the landscape of technology innovation that can help policymakers, state agencies, and interested parties develop strategies to meet the state’s goals and to target efforts to support and nurture technology innovation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Environmental and Societal Analysis of the US Electrical Energy Industry Based on the Water–Energy Nexus

To meet rising energy demands, power plant operations will expand, influencing the interactions between the water–energy nexus and society. However, a major challenge is integration of social dimensions within electricity generation. To address this, we generate a baseline dataset using US public data (2014–2019) from the Energy Information Administration and US Bureau of Labor Statistics. We identify the rate of energy consumed, CO 2 , SO 2 and NO x emissions generated, and water used per MWh net electricity as well as employee wellbeing per unit MW capacity during electricity generation. Rates of energy consumption (MMBtu/MWh) decreased 4.9%, but water consumption and withdrawal (m 3 /MWh) both increased 0.93% and 0.31%, respectively. Emissions of CO 2 , SO 2 and NO x decreased 22.64%, 75% and 25% MT/MWh, respectively. Thermoelectric cooling withdrawal and consumption is led by natural gas (50.07%, 38.31%), coal (29.61%, 25.07%), and nuclear energies (13.55%, 18.99%). Electric power generation contributes 0.06 injuries–illnesses/TWh and 0.001 fatalities/TWh, of which fossil fuels contributed 70% and 15%, respectively. Fossil fuels led in average annual employment (0.02 employees/MW) with low cost salaries (USD 0.09/MW) likely due to high collective capacity, which is declining. Estimated rates in this study and framework will aid power industry transition and operational decision makers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DC electric field generation and distribution in magnetized plasmas

Very large DC and AC electric fields cannot be sustained between conducting electrodes because of volume gas breakdown and/or surface field emission. However, very large potential fields are now routinely generated in plasma structures, such as laser generated wake in unmagnetized plasmas. In magnetized plasmas, large DC fields can also be sustained and controlled perpendicular to the magnetic field, but the metallic end plates limiting the plasma, terminating the magnetic field lines, and usually providing the voltage drop feed between the field lines impose severe restrictions on the maximum field. However, it is shown that very large radial DC voltage drops can be sustained by injecting waves of predetermined frequencies and wave vectors, traveling along the azimuthal direction of an axially magnetized plasma cylinder, or by injecting fast neutral particles beams along this azimuthal direction. The large conductivity along the magnetic field lines and the small conductivity between the field lines then distribute this voltage drop. Furthermore, the global power balance and control parameters of wave and beam generated large DC electric fields in magnetized plasmas are identified, described, and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonality and trade in hydro-heavy electricity markets: A case study with the West Africa Power Pool (WAPP)

Hydroelectric power plants account for 25% of West Africa's total installed capacity. In general, electricity generated by these plants is seasonal and intra-annual fluctuation has a considerable impact on electricity supply and cross-border electricity trade. We soft-linked a global hydrologic model to a multi-region capacity expansion and planning model for the West Africa Power Pool (WAPP) to examine the effects of seasonality in hydropower electricity generation on electricity trade, as well as the economic benefits of unconstrained cross-border electricity trade. We found that transitioning from rainy to dry season decreases hydroelectricity generation by an average of 40% in a normal year across the region. Between 2018 and 2050, satisfying the region's electricity demand will require significant capital investment; nevertheless, extending from current bilateral electricity trade agreements to a fully competitive cross-border electricity trade will result in net annual savings of $3 billion in 2015 USD. To achieve year-round energy security, countries should plan ahead and diversify their energy sources to ensure that supply reliability can be maintained in the case of lower supply during the dry season.

13 HYDRO ENERGY↗

Spatiotemporally resolved measurements of electric field around a piezoelectric transformer using electric-field induced second harmonic (E-FISH) generation

When a piezoelectric transformer (PT) is actuated at its second harmonic frequency by a low input voltage, the generated electric field at the distal end can be sufficient to breakdown the surrounding gas, making them attractive power sources for non-equilibrium plasma generation. Understanding the potential and electric fields produced in the surrounding medium by the PT is important for effectively designing and using PT plasma devices. In this work, the spatiotemporally resolved characteristics of the electric field generated by a PT operating in open air have been investigated using the femtosecond electric field-induced second harmonic generation (E-FISH) method. Here, electric field components were determined by simultaneously conducting E-FISH measurements with the incident laser polarized in two orthogonal directions relative to the PT crystal. Results of this work demonstrate the spatial distribution of electric field around the PT’s output distal end and how it evolves as a function of time. Notably, the strongest electric field appears on the face of the PT’s distal surface, near the top and bottom edges and decreases by approximately 70% over 3 mm. The time delay between the PT’s input voltage and measured electric field indicates that there is an about 0.45 phase difference between the PT’s input voltage and output signal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Achieving American Leadership in the Hydropower Supply Chain

In 2020, hydropower accounted for 36.7% of U.S. renewable electricity generation and 7.3% of total electricity generation. While the existing U.S. supply chain effectively supports the nation’s hydropower fleet—the fourth-largest in the world, alongside the third-largest pumped storage hydropower (PSH) fleet—refurbishments, upgrades, and new development are required to modernize and expand the fleet and facilitate a clean, emissions-free U.S. electricity grid by 2035. To achieve these goals, researchers compiled a report examining the U.S. hydropower energy supply chain, including raw materials, processed materials, components, subcomponents, and recycling.

Source record↗