Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Deep-Learning-Based Multi-Timescale Load Forecasting in Buildings: Opportunities and Challenges from Research to Deployment

Electricity load forecasting for buildings and campuses is becoming increasingly important as the penetration of distributed energy resources (DERs) grows. Efficient operation and dispatch of DERs require reasonably accurate predictions of future energy consumption in order to conduct near-real-time optimized dispatch of on-site generation and storage assets. Electric utilities have traditionally performed load forecasting for load pockets spanning large geographic areas, and therefore, forecasting has not been a common practice by buildings and campus operators. Given the growing trends of research and prototyping in the grid-interactive efficient buildings domain, characteristics beyond simple algorithm forecast accuracy are important in determining the algorithm's true utility for smart buildings. Other characteristics include the overall design of the deployed architecture and the operational efficiency of the forecasting system. In this work, we present a deep-learning-based load forecasting system that predicts the building load at 1-hour intervals for 18 hours in the future. We also discuss challenges associated with the real-time deployment of such systems as well as the research opportunities presented by a fully functional forecasting system that has been developed within the National Renewable Energy Laboratory's Intelligent Campus program.

building load forecasting↗

High-power ac/dc variable load simulator

Design of medium-power dynamic electrical load simulator has been extended to permit simulation of ac as well as dc loads and to provide for operation at higher power levels. Simulator is internally protected against reverse voltage, overvoltage, overcurrent, and overload conditions.

Joncas, K. P.↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Siamese CNN + KNN-Based Classification Framework for Non-intrusive Load Monitoring

Through the development of smart grids, programs such as demand side response, have been presented as auxiliary services to the real-time operation of distributed networks. In order to provide consumers information on their energy consumption, so that a modulation in consumption is possible, non-intrusive load monitoring has been introduced as an solution to this pattern recognition problem. Non-intrusive load monitoring enables the modeling of electrical loads connected to the low-voltage system, considering only a single measurement point. Presented state-of-the-art solutions though, consider availability of data as well as representation of all possible classes of the environment. This is of course a most conservative hypothesis, since in real-life applications availability of such data is much difficult, as well as the dynamic behavior of models is implicitly evolving in time. Here, a framework that uses neural Siamese networks with k-nearest neighbor clustering is presented toward non-intrusive load monitoring. Online learning feature is implemented, which relaxes the hypothesis of data requirements as well addresses the evolving nature of load profile. k-nearest clustering allows nonlinear characteristic space modelling. Test results using synthetics and real-life data show that the solution, besides obtaining a good generalizability in the classification, also obtained results with an accuracy of 95.77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovative Technologies for a Low Carbon Electricity System

The electricity sector represents the centerpiece of decarbonization pathways for the state. Decrease in the cost of renewable electricity generation, combined with ample solar energy, wind and other renewable resources, presents a realistic way to achieve electricity generation that is nearly free of CO 2 emissions by mid-century. Expansion of renewable electricity supply could allow replacement of many CO 2 -emitting technologies with ones that use electricity—in transportation, buildings, and possibly industry. Key elements of the path for California’s electricity sector are: restrain electricity demand through higher efficiency, rapidly expand renewable electricity generation, develop electricity storage to complement renewable electricity, manage flexible electricity loads for a low-carbon electricity system, electrify where appropriate to reduce CO 2 emissions, and maintain reliable and resilient electricity supply. This report provides an overview of a multitude of innovative technologies in each of the above areas that have the potential to help the state meet its decarbonization goals, while lowering costs and promoting greater reliability. The information presented provides a portrait of the landscape of technology innovation that can help policymakers, state agencies, and interested parties develop strategies to meet the state’s goals and to target efforts to support and nurture technology innovation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Drive Train Normal Modes Analysis for the ERDA/NASA 100-Kilowatt Wind Turbine Generator

Natural frequencies, as a function of power were determined using a finite element model. Operating conditions investigated were operation with a resistive electrical load and operation synchronized to an electrical utility grid. The influence of certain drive train components on frequencies and mode shapes is shown. An approximate method for obtaining drive train natural frequencies is presented.

Sullivan, T. L.↗

Development of Electronic Load Controllers for Free-Piston Stirling Convertors Aided by Stirling Simulation Model

The free-piston Stirling convertor end-to-end modeling effort at the NASA Glenn Research Center has produced a software-based test bed in which free-piston Stirling convertors can be simulated and evaluated. The simulation model includes all the components of the convertor: the Stirling cycle engine, heat source, linear alternator, controller, and load. So far, it has been used in evaluating the performance of electronic controller designs. Three different controller design concepts were simulated using the model: 1) Controllers with parasitic direct current loading. 2) Controllers with parasitic alternating current loading. 3) Controllers that maintain a reference current. The free-piston Stirling convertor is an electromechanical device that operates at resonance. It is the function of the electronic load controller to ensure that the electrical load seen by the machine is always great enough to keep the amplitude of the piston and alternator oscillation at the rated value. This is done by regulating the load on the output bus. The controller monitors the instantaneous voltage, regulating it by switching loads called parasitic loads onto the bus whenever the bus voltage is too high and removing them whenever the voltage is too low. In the first type of controller, the monitor-ing and switching are done on the direct-current (dc) bus. In the second type, the alternating current bus is used. The model allows designers to test a controller concept before investing time in hardware. The simulation code used to develop the model also offers detailed models of digital and analog electronic components so that the resulting designs are realistic enough to translate directly into hardware circuits.

Regan, Timothy F.↗

Magnetostrictive Vibration Damper and Energy Harvester for Rotating Machinery

Vibrations generated by machine driveline components can cause excessive noise and structural damage. Magnetostrictive materials, including Galfenol (iron-gallium alloys) and Terfenol-D (terbium-iron-dysprosium alloys), are able to convert mechanical energy to magnetic energy. A magnetostrictive vibration ring is proposed, which generates electrical energy and dampens vibration, when installed in a machine driveline. A 2D axisymmetric finite element (FE) model incorporating magnetic, mechanical, and electrical dynamics is constructed in COMSOL Multiphysics. Based on the model, a parametric study considering magnetostrictive material geometry, pickup coil size, bias magnet strength, flux path design, and electrical load is conducted to maximize loss factor and average electrical output power. By connecting various resistive loads to the pickup coil, the maximum loss factors for Galfenol and Terfenol-D due to electrical energy loss are identified as 0.14 and 0.34, respectively. The maximum average electrical output power for Galfenol and Terfenol-D is 0.21 W and 0.58 W, respectively. The loss factors for Galfenol and Terfenol-D are increased to 0.59 and 1.83, respectively, by using an L-C resonant circuit.

Magnetostrictive↗

Energy use of residential safety, security, and health devices

Miscellaneous electrical loads (MELs) are responsible for a significant fraction of energy consumption in buildings. This paper addresses one category of MELs: Safety, Security, and Health Devices (SSHDs). Common SSHDs include: electrical life safety equipment, smoke alarms, radon mitigation fans, and home oxygen concentrators. The installation or use of these devices is dictated by building codes, health providers, insurance companies, and other entities—none of which would ordinarily consider energy efficiency a priority. For this project, the most important residential devices were explored in terms of their governing regulations, functions, technologies, and energy use. The power consumption of 41 life safety SSHDs were measured. Individual power consumption of life safety devices is very small but many are typically required in every home. Devices performing the same functions have wide ranges in power use. Opportunities for reducing SSHD energy use were investigated, the results are summarized, and recommendations are made for further actions that could be taken to reduce SSHD energy use. Finally, SSHDs identified in this paper are responsible for at least one percent of current U.S. residential electricity consumption, but that number will climb steadily as existing buildings are upgraded and new types of SSHDs appear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

Impedance Measurements of Motor Drives and Supply in SPEED Testbed

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. To enable these measurements, personnel at NASA’s Glenn research Center have designed and built the Scaled Power ElEctrified Drivetrain (SPEED) Testbed. This paper will present data taken in the SPEED lab, including impedance measurements of a DC supply (source) and a motor drive and electric machine (load) under a number of conditions. Impacts of load power, drive controller tuning, and field weakening on load impedance are measured, presented, and discussed; as are source impedance data, and DC bus current spectra at different loading levels.

electrified aircraft propulsion↗

Impedance Measurements of Motor Drive and Supply in SPEED Testbed

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. To enable these measurements, personnel at NASA’s Glenn Research Center have designed and built the Scaled Power ElEctrified Drivetrain (SPEED) Testbed. This paper will present data taken in the SPEED lab, including impedance measurements of a DC supply (source) and a motor drive and electric machine (load) under a number of conditions. Impacts of load power, drive controller tuning, and field-weakening on load impedance are measured, presented, and discussed; as are source impedance data, stability, and DC bus current spectra at different loading levels.

electrified aircraft propulsion↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

High-Energy-Density Electrolytic Capacitors

Reductions in weight and volume make new application possible. Supercapacitors and improved ultracapacitors advanced electrolytic capacitors developed for use as electric-load-leveling devices in such applications as electric vehicle propulsion systems, portable power tools, and low-voltage pulsed power supplies. One primary advantage: offer power densities much higher than storage batteries. Capacitors used in pulse mode, with short charge and discharge times. Derived from commercially available ultracapacitors. Made of lightweight materials; incorporate electrode/electrolyte material systems capable of operation at voltages higher than previous electrode/electrolyte systems. By use of innovative designs and manufacturing processes, made in wide range of rated capacitances and in rated operating potentials ranging from few to several hundred volts.

Yen, Shiao-Ping S.↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Simulating dispatchable grid services provided by flexible building loads: State of the art and needed building energy modeling improvements

End-use electrical loads in residential and commercial buildings are evolving into flexible and cost-effective resources to improve electric grid reliability, reduce costs, and support increased hosting of distributed renewable generation. This article reviews the simulation of utility services delivered by buildings for the purpose of electric grid operational modeling. We consider services delivered to (1) the high-voltage bulk power system through the coordinated action of many, distributed building loads working together, and (2) targeted support provided to the operation of low-voltage electric distribution grids. Although an exhaustive exploration is not possible, we emphasize the ancillary services and voltage management buildings can provide and summarize the gaps in our ability to simulate them with traditional building energy modeling (BEM) tools, suggesting pathways for future research and development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impedance Measurements of Motor Drives and Supplies in NASA NEAT Facility

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. This paper discusses impedance measurements made on the NASA Electric Aircraft Testbed (NEAT) Electrical Power System (EPS) at NASA Glenn Research Center. First, an overall discussion of the NEAT facility configuration during testing is presented; then details of the impedance measurement approach and the various testing configurations are discussed. Next, input impedance measurements at NEAT, including sources (DC supplies) and loads (multiple motor drives, electric machines, and resistive load banks, with long interconnecting cable leads), are performed under a number of conditions, and results, including load model comparisons and stability analysis, are presented and discussed.

electrified aircraft propulsion↗