Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “effusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Thermodynamic Measurements Using the Knudsen Cell Technique

The Knudsen cell technique has been used for over a century and is a valuable tool for measurement of vapor pressures and thermodynamic properties. It is based on a small enclosure (~1 cm long x 1 cm diameter) in which a condensed phase/vapor equilibria can be established. A small (<1 mm) orifice on the cell allows sampling of the vapor via a variety of techniques including weight loss, torsion effusion, target collection, and mass spectrometry. Many excellent measurements based on these methods have been reported. However in order to obtain reliable measurements, a variety of factors must be considered. They include proper cell material selection, accurate and uniform temperature control and measurement, and proper sampling of the vapor. Each of these factors are discussed in detail in this chapter. Typically these studies are conducted at high temperatures and it is a challenge to select an inert container material. Recommended materials are discussed and in some cases the container may be used as part of the system under study. Temperature control and measurement is perhaps the most important issue. In most systems, the furnace must be compact yet there can be no temperature gradient in the cell. Temperatures are measured with either a thermocouple or pyrometer and the relative advantages of each are discussed. Sampling method considerations depend on the particular technique. It is essential that all of the vapor or a representative portion of the vapor be sampled. The distribution of the effusate from a Knudsen cell is discussed and sampling positions discussed. Mass spectrometry is often used to study the effusing vapor and the relations between ion current and vapor pressure are discussed.

mass spectrometry↗

Soft ionization of thermally evaporated hypergolic ionic liquid aerosols

Isolated ion pairs of a conventional ionic liquid, 1-Ethyl-3-Methyl-Imidazolium Bis(trifluoromethylsulfonyl)imide ([Emim+][Tf2N?]), and a reactive hypergolic ionic liquid, 1-Butyl-3-Methyl-Imidazolium Dicyanamide ([Bmim+][Dca?]), are generated by vaporizing ionic liquid submicron aerosol particles for the first time; the vaporized species are investigated by dissociative ionization with tunable vacuum ultraviolet (VUV) light, exhibiting clear intact cations, Emim+ and Bmim+, presumably originating from intact ion pairs. Mass spectra of ion pair vapor from an effusive source of the hypergolic ionic liquid show substantial reactive decomposition due to the internal energy of the molecules emanating from the source. Photoionization efficiency curves in the near threshold ionization region of isolated ion pairs of [Emim+][Tf2N?]ionic liquid vapor are compared for an aerosol source and an effusive source, revealing changes in the appearance energy due to the amount of internal energy in the ion pairs. The aerosol source has a shift to higher threshold energy (~;;0.3 eV), attributed to reduced internal energy of the isolated ion pairs. The method of ionic liquid submicron aerosol particle vaporization, for reactive ionic liquids such as hypergolic species, is a convenient, thermally ?cooler? source of isolated intact ion pairs in the gas phase compared to effusive sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transport thermal properties of LiTaO 3 pyroelectric sensor from 15 K to 400 K and its application to the study of critical behavior in EuCo 2 As 2

ac photopyroelectric calorimeters in the standard back configuration, where LiTaO 3 is one of the most popular materials to be used as a detector, are commonly used to study phase transitions in solids and liquids. In order to extract the specific heat of a studied sample, a good knowledge of the thermal effusivity of the sensor as a function of temperature is needed. This function has been obtained for the first time in the range 15 K to 400 K by independently measuring LiTaO 3 thermal diffusivity and specific heat and combining both of them to give thermal effusivity. Using this photopyroelectric setup and LiTaO 3 as sensor, we have carried out the study of the critical behavior of the antiferromagnetic ordering of the Eu 2+ spins in EuCo 2 As 2 (a compound with similar structure as EuFe 2 As 2 , from which superconductors have been developed) at low temperature by measuring its specific heat. Furthermore, the critical parameters found for EuCo 2 As 2 (α=–0.017,A + /A – =1.06) agree with the 3D-XY universality class, indicating that the spins present an in-plane arrangement for Eu 2+ , in agreement with magnetic measurements in the literature.

47 OTHER INSTRUMENTATION↗

Persistent energy harvesting in the harsh desert environment using a thermal resonance device: Design, testing, and analysis

Thermal fluctuations in the environment are a ubiquitous, yet untapped energy source for harvesting. Our laboratory has introduced the concept of a thermal resonance device for this purpose, with potential to power wireless sensor networks (WSNs), devices embedded into structural elements, and electronics deployed in relatively inaccessible areas. This approach has particular advantages for the desert environment, where conventional energy harvesting devices are severely confounded by frequent sandstorms, extreme temperature and high solar fluence. Herein, we design, fabricate, and test a thermal resonator for the conversion of diurnal temperature fluctuations to electrical power in a harsh desert environment using a thermally conductive phase change composite as a high thermal effusivity material, specifically tuned to the temperature fluctuating environment of Thuwal, Saudi Arabia (22.3095°N, 39.1047°E). The composite consists of a highly porous and thermally conductive nickel foam impregnated with eicosane as a phase change material for enhanced thermal capacity. The high thermal effusivity material is incorporated into a rationally-designed thermal resonance device, which is tested for a period of two weeks in Saudi Arabia, extracting as high as 2 mW from approximately 10 °C diurnal temperature fluctuations. These experimental data provide a test of the theoretical model for the design and operation of the device. Overall, these results highlight the opportunity of employing thermal resonance devices for energy harvesting, particularly in the desert environment.

30 DIRECT ENERGY CONVERSION↗

Ash production and dispersal from sustained low-intensity Mono-Inyo eruptions

Recent rhyolitic volcanism has demonstrated that prolonged low-intensity ash venting may accompany effusive dome formation. In this work, we examine the possibility and some consequences of episodes of extended, weak ash venting at the rhyolitic Mono-Inyo chain in Eastern California. We describe ash-filled cracks within one of the youngest domes, Panum Crater, which provide a textural record of ash venting during dome effusion. We use synchrotron-based X-ray computed tomography to characterize the particles in these tuffisites. Particle sizes in well-sorted tuffisite layers agree well with grain size distributions observed during weak ash venting at Soufrière Hills Volcano, Montserrat, and yield approximate upper and lower bounds on gas velocity and mass flux during the formation of those layers. We simulate ash dispersal with Ash3d to assess the consequences of long-lived Mono-Inyo ash venting for ash deposition and the accompanying volcanic hazards. Finally, our results highlight the sensitivity of large-scale outcomes of volcanic eruptions to small-scale processes.

54 ENVIRONMENTAL SCIENCES↗

Prognostic Factors and Outcome in Askin-Rosai Tumor: A Review of 104 Patients

Purpose: To evaluate the prognostic factors and treatment outcome of patients with Askin-Rosai tumor of the chest wall treated at a single institution. Methods and Materials: Treatment comprised multiagent chemotherapy and local therapy, which was either in the form of surgery alone, radical external-beam radiotherapy (EBRT) alone, or a combination of surgery and EBRT. Thirty-two patients (40%) were treated with all three modalities, 21 (27%) received chemotherapy and radical EBRT, and 19 (24%) underwent chemotherapy followed by surgery only. Results: One hundred four consecutive patients aged 3-60 years were treated at the Tata Memorial Hospital from January 1995 to October 2003. Most (70%) were male (male/female ratio, 2.3:1). Asymptomatic swelling (43%) was the most common presenting symptom, and 25% of patients presented with distant metastasis. After a median follow-up of 28 months, local control, disease-free survival, and overall survival rates were 67%, 36%, and 45%, respectively. Median time to relapse was 25 months, and the median survival was 76 months. Multivariate analysis revealed age {>=}18 years, poor response to induction chemotherapy, and presence of pleural effusion as indicators of inferior survival. Fifty-six percent of patients with metastatic disease at presentation died within 1 month of diagnosis, with 6-month and 5-year actuarial survival of 14% and 4%, respectively. Conclusion: Primary tumor size, pleural effusion, response to chemotherapy, and optimal radiotherapy were important prognostic factors influencing outcome. The combination of neoadjuvant chemotherapy, surgery, and radiotherapy resulted in optimal outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of High-Risk Computed Tomography Features for Detection of Local Recurrence After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

Purpose: Fibrotic changes after stereotactic body radiation therapy (SBRT) for stage I non-small cell lung cancer (NSCLC) are difficult to distinguish from local recurrences (LR), hampering proper patient selection for salvage therapy. This study validates previously reported high-risk computed tomography (CT) features (HRFs) for detection of LR in an independent patient cohort. Methods and Materials: From a multicenter database, 13 patients with biopsy-proven LR were matched 1:2 to 26 non-LR control patients based on dose, planning target volume (PTV), follow-up time, and lung lobe. Tested HRFs were enlarging opacity, sequential enlarging opacity, enlarging opacity after 12 months, bulging margin, linear margin disappearance, loss of air bronchogram, and craniocaudal growth. Additionally, 2 new features were analyzed: the occurrence of new unilateral pleural effusion, and growth based on relative volume, assessed by manual delineation. Results: All HRFs were significantly associated with LR except for loss of air bronchogram. The best performing HRFs were bulging margin, linear margin disappearance, and craniocaudal growth. Receiver operating characteristic analysis of the number of HRFs to detect LR had an area under the curve (AUC) of 0.97 (95% confidence interval [CI] 0.9-1.0), which was identical to the performance described in the original report. The best compromise (closest to 100% sensitivity and specificity) was found at ≥4 HRFs, with a sensitivity of 92% and a specificity of 85%. A model consisting of only 2 HRFs, bulging margin and craniocaudal growth, resulted in a sensitivity of 85% and a specificity of 100%, with an AUC of 0.96 (95% CI 0.9-1.0) (HRFs ≥2). Pleural effusion and relative growth did not significantly improve the model. Conclusion: We successfully validated CT-based HRFs for detection of LR after SBRT for early-stage NSCLC. As an alternative to number of HRFs, we propose a simplified model with the combination of the 2 best HRFs: bulging margin and craniocaudal growth, although validation is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermodynamic studies on lithium ferrites

Thermodynamic studies on ternary oxides of Li-Fe-O systems were carried out using differential scanning calorimetry, Knudsen effusion mass spectrometry, and solid-state electrochemical technique based on fluoride electrolyte. Heat capacities of LiFe{sub 5}O{sub 8}(s) and LiFeO{sub 2}(s) were determined in the temperature range 127-861 K using differential scanning calorimetry. Gibbs energies of formation of LiFe{sub 5}O{sub 8}(s) and LiFeO{sub 2}(s) were determined using Knudsen effusion mass spectrometry and solid-state galvanic cell technique. The combined least squares fits can be represented as {Delta}{sub f}G{sub m}{sup o}(LiFe{sub 5}O{sub 8},s,T)/kJ mol{sup -1} ({+-}6)=-2341+0.6764(T/K) (588{<=}T/K{<=}971) {Delta}{sub f}G{sub m}{sup o}(LiFeO{sub 2},s,T)/kJ mol{sup -1} ({+-}3)=-708+0.1656(T/K) (569{<=}T/K{<=}1021) The temperature independent term of the above equations represents {Delta}{sub f}H{sup o}{sub m}(T{sub av}) and temperature dependent term represents negative change in entropy of the respective compounds. Thermodynamic analysis shows that LiFe{sub 5}O{sub 8}(s) is more stable compared to LiFeO{sub 2}(s). -- Graphical abstract: Comparison of {Delta}{sub f}G{sub m}{sup o}(T) of lithium ferrites determined using different techniques. Display Omitted Highlights: {yields} Thermodynamic studies on Li-Fe-O system using DSC, KEQMS and galvanic cell. {yields} Heat capacities of LiFe{sub 5}O{sub 8}(s) and LiFeO{sub 2}(s) were determined using DSC 127-861 K. {yields} {Delta}{sub f}G{sup o}{sub m} of these compounds were determined and compared. {yields} Thermodynamic tables for LiFe{sub 5}O{sub 8}(s) and LiFeO{sub 2}(s) were constructed.

36 MATERIALS SCIENCE↗

Self-irradiation enhanced tritium solubility in hydrogenated amorphous and crystalline silicon

Experimental results on tritium effusion, along with the tritium depth profiles, from hydrogenated amorphous silicon (a-Si:H) and crystalline silicon (c-Si) tritiated in tritium (T{sub 2}) gas at various temperatures and pressures are presented. The results indicate that tritium incorporation is a function of the material microstructure of the as-grown films, rather than the tritium exposure condition. The highest tritium concentration obtained is for a-Si:H deposited at a substrate temperature of 200 deg. C. The tritium content is about 20 at. % on average with a penetration depth of about 50 nm. In contrast, tritium occluded in the c-Si is about 4 at. % with penetration depth of about 10 nm. The tritium concentration observed in a-Si:H and c-Si is much higher than the reported results for the post-hydrogenation process. {beta} irradiation appears to catalyze the tritiation process and enhance tritium dissolution in the silicon matrix. The combination of tritium decay and {beta}-induced ionizations results in formation of reactive species of tritium (tritium atoms, radicals, and ions) that readily adsorb on silicon. The electron bombardment of the silicon surface and subsurface renders it chemically active thereby promoting surface adsorption and subsurface diffusion of tritium, thus leading to tritium occlusion in the silicon matrix. Gaussian deconvolution of tritium effusion spectra yields two peaks for a-Si:H films tritiated at high temperature (250 deg. C), one low temperature (LT) peak which is attributed to tritiated clusters and higher order tritides, and another high temperature peak which is attributed to monotritides. Activation energy of 2.6-4.0 eV for the LT peak was found.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-destructive thermal wave method applied to study thermal properties of fast setting time endodontic cement

The thermal wave method is applied for thermal properties measurement in fast endodontic cement (CER). This new formula is developed upon using Portland cement in gel and it was successfully tested in mice with good biocompatibility and stimulated mineralization. Recently, thermal expansion and setting time were measured, conferring to this material twice faster hardening than the well known Angelus Mineral trioxide aggregate (MTA) the feature of fast hardening (∼7 min) and with similar thermal expansion (∼12 μstrain/ °C). Therefore, it is important the knowledge of thermal properties like thermal diffusivity, conductivity, effusivity in order to match thermally the tissue environment upon its application in filling cavities of teeth. Photothermal radiometry technique based on Xe illumination was applied in CER disks 600 μm thick for heating, with prepared in four particle sizes (25, 38, 45, and 53) μm, which were added microemulsion gel with variation volumes (140, 150, 160, and 170) μl. The behavior of the thermal diffusivity CER disks shows linear decay for increase emulsion volume, and in contrast, thermal diffusivity increases with particles sizes. Aiming to compare to MTA, thermal properties of CER were averaged to get the figure of merit for thermal diffusivity as (44.2 ± 3.6) × 10{sup −3} cm{sup 2}/s, for thermal conductivity (228 ± 32) mW/cm K, the thermal effusivity (1.09 ± 0.06) W s{sup 0.5}/cm{sup 2} K and volume heat capacity (5.2 ± 0.7) J/cm{sup 3} K, which are in excellent agreement with results of a disk prepared from commercial MTA-Angelus (grain size < 10 μm using 57 μl of distilled water)

36 MATERIALS SCIENCE↗

Facility for low-temperature spin-polarized-scanning tunneling microscopy studies of magnetic/spintronic materials prepared in situ by nitride molecular beam epitaxy

Based on the interest in, as well as exciting outlook for, nitride semiconductor based structures with regard to electronic, optoelectronic, and spintronic applications, it is compelling to investigate these systems using the powerful technique of spin-polarized scanning tunneling microscopy (STM), a technique capable of achieving magnetic resolution down to the atomic scale. However, the delicate surfaces of these materials are easily corrupted by in-air transfers, making it unfeasible to study them in stand-alone ultra-high vacuum STM facilities. Therefore, we have carried out the development of a hybrid system including a nitrogen plasma assisted molecular beam epitaxy/pulsed laser epitaxy facility for sample growth combined with a low-temperature, spin-polarized scanning tunneling microscope system. The custom-designed molecular beam epitaxy growth system supports up to eight sources, including up to seven effusion cells plus a radio frequency nitrogen plasma source, for epitaxially growing a variety of materials, such as nitride semiconductors, magnetic materials, and their hetero-structures, and also incorporating in situ reflection high energy electron diffraction. The growth system also enables integration of pulsed laser epitaxy. The STM unit has a modular design, consisting of an upper body and a lower body. The upper body contains the coarse approach mechanism and the scanner unit, while the lower body accepts molecular beam epitaxy grown samples using compression springs and sample skis. The design of the system employs two stages of vibration isolation as well as a layer of acoustic noise isolation in order to reduce noise during STM measurements. This isolation allows the system to effectively acquire STM data in a typical lab space, which during its construction had no special and highly costly elements included, (such as isolated slabs) which would lower the environmental noise. The design further enables tip exchange and tip coating without breaking vacuum, and convenient visual access to the sample and tip inside a superconducting magnet cryostat. A sample/tip handling system is optimized for both the molecular beam epitaxy growth system and the scanning tunneling microscope system. The sample/tip handing system enables in situ STM studies on epitaxially grown samples, and tip exchange in the superconducting magnet cryostat. The hybrid molecular beam epitaxy and low temperature scanning tunneling microscopy system is capable of growing semiconductor-based hetero-structures with controlled accuracy down to a single atomic-layer and imaging them down to atomic resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-corrected Sensors Based On Atomic Absorption Spectroscopy For Atom Flux Measurements In Molecular Beam Epitaxy

A high sensitivity atom flux sensor based on atomic absorption spectroscopy has been designed and implemented to control electron beam evaporators and effusion cells in a molecular beam epitaxy system. Using a high-resolution spectrometer and a two-dimensional charge coupled device (CCD) detector in a double-beam configuration, we employ a non-resonant line or a resonant line with lower absorbance from the same hollow cathode lamp as the reference for nearly perfect background correction and baseline drift removal. This setup also significantly shortens the warm-up time needed compared to other sensor technologies and drastically reduces the noise coming from the surrounding environment. In addition, the high-resolution spectrometer allows the most sensitive resonant line to be isolated and used to provide excellent signal-to-noise ratio.

Environmental Molecular Sciences Laboratory↗

Optical layer development for thin films thermal conductivity measurement by pulsed photothermal radiometry

Measurement of thermal conductivity and volumetric specific heat of optically transparent thin films presents a challenge for optical-based measurement methods like pulsed photothermal radiometry. We present two approaches: (i) addition of an opaque optical layer to the surface and (ii) approximate correction of the mathematical model to incorporate semitransparency of the film. Different single layer and multilayer additive optical layers were tested. The materials of the optical layers were chosen according to analysis and measurement of their optical properties: emissivity and absorption coefficient. Presented are thermal properties’ measurement results for 6 different thin films with wide range of thermal conductivity in three configurations of surface: as deposited, added Ti layer, and added Ti/TiAlSiN layer. Measurements were done in dependence on temperature from room temperature to 500 °C. The obtained thermal effusivity evolution in time after the laser pulse shows different effects of the surface layers: apparent effusivity change and time delay. Suitability of different measurement configurations is discussed and results of high temperature testing of different optical layers are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of CsK{sub 2}Sb photocathode lifetime with antimony thickness

CsK{sub 2}Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for the alkali.

36 MATERIALS SCIENCE↗

Accessing a growth window for SrVO{sub 3} thin films

Stoichiometric SrVO{sub 3} thin films were grown over a range of cation fluxes on (001) (La{sub 0.3}Sr{sub 0.7})(Al{sub 0.65}Ta{sub 0.35})O{sub 3} substrates using hybrid molecular beam epitaxy, where a thermal effusion cell was employed to generate a Sr flux and V was supplied using the metal-organic precursor vanadium oxytriisopropoxide (VTIP). By systematically varying the VTIP flux while keeping the Sr flux constant, a range of flux ratios were discovered in which the structural and electronic properties of the SrVO{sub 3} films remained unaltered. The intrinsic film lattice parameter and residual resistivity were found to be the smallest inside the growth window, indicating the lowest defect concentration of the films, and rapidly increased for cation flux ratios deviating from ideal growth condition. Reflection high-energy electron diffraction showed that films grown within this range had smooth surfaces and diffraction patterns were free of additional spots, while otherwise the growing surface was rough and contained additional crystalline phases. Results show the existence of a SrVO{sub 3} growth window at sufficiently high growth temperature, in which high-quality, stoichiometric films can be grown in a robust, highly reproducible manner that is invulnerable to unintentional flux variation.

36 MATERIALS SCIENCE↗

Modulation calorimetry in diamond anvil cells. II. Joule-heating design and prototypes

Here, Part I shows that quantitative measurements of heat capacity are theoretically possible inside diamond anvil cells via high-frequency Joule heating (100 kHz–10 MHz), opening up the possibility of new methods to detect and characterize transformations at high-pressure such as the glass transitions, melting, magnetic orderings, and the onset of superconductivity. Here, we test the possibility outlined in Part I, using prototypes and detailed numerical models. First, a coupled electrical-thermal numerical model shows that specific heat of metals inside diamond cells can be measured directly using ~1 MHz frequency, with <10% accuracy. Second, we test physical models of high-pressure experiments, i.e., diamond-cell mock-ups. Metal foils of 2–6 μm-thickness are clamped between glass insulation inside diamond anvil cells. Fitting data from 10 Hz to ~30 kHz, we infer the specific heat capacities of Fe, Pt, and Ni with ±20%–30% accuracy. The electrical test equipment generates -80 dBc spurious harmonics, which overwhelm the thermally induced harmonics at higher frequencies, disallowing the high precision expected from numerical models. An alternative Joule-heating calorimetry experiment, on the other hand, does allow absolute measurements with < 10% accuracy, despite the -80 dBc spurious harmonics: the measurement of thermal effusivity, $ \sqrt{ρck}$ (ρ, c , and k being density, specific heat, and thermal conductivity), of the insulation surrounding a thin-film heater. Using a ~50 nm-thick Pt heater surrounded by glass and 10 Hz–300 kHz frequency, we measure thermal effusivity with ±6% accuracy inside the sample chamber of a diamond anvil cell.

42 ENGINEERING↗

Classification of computed thermal tomography images with deep learning convolutional neural network

Thermal tomography (TT) is a computational method for the reconstruction of depth profile of the internal material defects from Pulsed Infrared Thermography (PIT) nondestructive evaluation. Here, the PIT method consists of recording material surface temperature transients with a fast frame infrared camera, following thermal pulse deposition on the material surface with a flashlamp and heat diffusion into material bulk. TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of the subsurface internal defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to the heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify the size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. The performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shapes imported from scanning electron microscopy images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on the TT images of elliptical defects is capable of classifying the shape and orientation of irregular defects.

42 ENGINEERING↗

REACTIONS OF COLD TRAPPED CH{sup +} IONS WITH SLOW H ATOMS

The destruction of CH{sup +} ions in collisions with H atoms has been studied in a temperature-variable 22 pole ion trap (22PT) combined with a cold effusive H-atom beam. The stored ions are relaxed to temperatures of T{sub 22PT} {>=} 12 K. The hydrogen atoms, produced in a radio frequency discharge, are slowed down to various temperatures of T{sub ACC} {>=} 7 K. They are formed into an effusive beam. The effective density of the hydrogen atoms in the trap as well as the H{sub 2} background are determined in situ using chemical probing with CO{sub 2}{sup +}. The experimental arrangement allows us not only to measure thermal rate coefficients (T{sub 22PT} = T{sub ACC}), but also to extract state-specific rate coefficients k(J,T{sub t}) at selected translational temperatures T{sub t} and for the CH{sup +} rotational states J = 0, 1, and 2. The measured thermal rate coefficients have a maximum at 60 K, k = (1.2 {+-} 0.5)x10{sup -9} cm{sup 3} s{sup -1}. Toward higher temperatures, they fall off in accordance with previous measurements and the trend predicted by phase space theory. Toward lower temperatures, the rate coefficients decrease significantly, especially if the rotation of the ions is cooled. At the coldest conditions achieved (beam: 7.3 K; trap: 12.2 K), a value as low as (5 {+-} 4) x 10{sup -11} cm{sup 3} s{sup -1} has been measured. This leads to the conclusion that non-rotating CH{sup +} is protected against attacks of H atoms. This surprising result is not yet understood. It is most probably due to quantum-dynamical effects already occurring at large distances.

79 ASTRONOMY AND ASTROPHYSICS↗