Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “effect measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Vibration analysis utilizing Mossbauer effect

Measuring instrument analyzes mechanical vibrations in transducers at amplitudes in the range of a few to 100 angstroms. This instrument utilizes the Mossbauer effect, the phenomenon of the recoil-free emission and resonant absorption of nuclear gamma rays in solids.

Roughton, N. A.↗

Electronic heterodyne moire deflectometry: A method for transient and three dimensional density fields measurements

Effects of diffraction and nonlinear photographic emulsion characteristics on the performance of deferred electronic heterodyne moire deflectometry are investigated. The deferred deflectometry is used for measurements of nonsteady phase objects where it is difficult to complete the analysis of the field in real time. The sensitivity, accuracy and resolution of the system are calculated and it is shown that they are weakly affected by diffraction and by nonlinear recording. The feactures of the system are significantly improved compared with the conventional deferred intensity moire technique, and are comparable with the online heterodyne moire. The system was evaluated experimentally by deferred measurements of the refractive index gradients of a weak phase object consisting of a large KD*P crystal. This was done by photographing the phase object through a Ronchi grating and analyzing the tranparency with the electronic heterodyne readout system. The results are compared with the measurements performed on the same phase object with online heterodyne moire deflectometry and with heterodyne holographic interferometry methods. Some practical considerations for system improvement are discussed.

Stricker, Josef↗

Deferred electronic heterodyne moire deflectometry: A method for transient density fields measurement

Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.

Stricker, Josef↗

Atmospheric aerosols: Their Optical Properties and Effects

Measured properties of atmospheric aerosol particles are presented. These include aerosol size frequency distribution and complex retractive index. The optical properties of aerosols are computed based on the presuppositions of thermodynamic equilibrium and of Mie-theory.

Source record↗

FBI fingerprint identification automation study: AIDS 3 evaluation report. Volume 8: Measures of effectiveness

The development of both quantitative criteria that were used to evaluate conceptional systems for automating the functions for the FBI Identification Division is described. Specific alternative systems for automation were compared by using these developed criteria, defined as Measures of Effectiveness (MOE), to gauge system's performance in attempting to achieve certain goals. The MOE, essentially measurement tools that were developed through the combination of suitable parameters, pertain to each conceivable area of system operation. The methods and approaches used, both in selecting the parameters and in using the resulting MOE, are described.

Mulhall, B. D. L.↗

The effect of measurement errors and computational approximations on a perspective ILM radar image

The effect was examined of aircraft position and attitude, of measurement errors, and of computational approximations on the size, shape, and position of a perspective radar image of an airport runway as might be displayed by an independent landing monitor in transport aircraft. The effect on runway image geometry was examined for different aircraft attitudes and different aircraft positions relative to a standard three degree glide slope. Measurement errors investigated were errors in radar azimuth angle and range, and errors in those aircraft parameters supplied to the radar for use in converting the radar image into a perspective format (namely pitch, roll, and altitude). Also investigated were the effects of using certain mathematical approximations, such as small angle, in the coordinate transformation which converts the image to a perspective format.

Bundick, W. T.↗

A Step Towards Electric Propulsion Testing Standards: Pressure Measurements and Effective Pumping Speeds

The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Existing practices are fallible and result in testing variations which leads to suspicious results, large margins in application, or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration and on-orbit performance. A preliminary step to progress towards universally applicable testing standards is outlined for facility pressure measurements and effective pumping speed calculations. The standard has been applied to multiple facilities at the NASA Glenn Research Center. Test results and analyses of universality of measurements are presented herein.

Dankanich, John W.↗

Fluids and their Effect on Measurements on Lunar Soil Particle size Distribution

From the late 1960s until now, lunar soil particle size distributions have typically been determined by sieving sometimes dry, and at other times with fluids such as water or Freon. Laser diffraction instruments allow rapid assessment of particle size distribution, and eventually may replace sieve measurements. However, when measuring lunar soils with laser diffraction instruments, care must be taken in choosing a carrier fluid that is compatible with lunar material. Distilled water is the fluid of choice for laser diffraction measurements of substances when there is no concern about adverse effects of water on the material being measured. When we began our analyses of lunar soils using laser diffraction, our first measurements were made with distilled water. Although the medians that we measured were comparable to earlier sieve data, the means tended to be significantly larger than expected. The effect of water vapor on lunar soil has been studied extensively. The particles interact strongly with water vapor, and subsequent adsorptions of nitrogen showed that the specific surface area increased as much as threefold after exposure to moisture. It was observed that significant porosity had been generated by this exposure to water vapor. The possibility of other physical changes in the surfaces of the grains was not studied.

Cooper, B. L.↗

Investigation of a moving-model technique for measuring ground effect

A ground-based testing technique is under development for the measurement of dynamic or time-dependent ground effects which may be present during aircraft approach and landing. The technique utilizes a model moving horizontally over an upwardly-inclined ground plane to simulate rate of descent. Results were obtained in the Langley Research Center (LaRC) Vortex Research Facility (VRF) for a generic 60 delta wing and for an F-18 configuration, both with and without thrust reversing, at forward speeds up to 100 ft/sec. These same models and support hardware were also tested in the LaRC 14 by 22 Foot Subsonic Tunnel at identical conditions (but without rate of descent) with and without a moving-belt ground plane to obtain data for comparison.

Kemmerly, Guy T.↗

Misalignment Effect Function Measurement for Oblique Rotation Axes: Counterintuitive Predictions and Theoretical Extensions

The Misalignment Effect Function (MEF) describes the decrement in manual performance associated with a rotation between operators' visual display frame of reference and that of their manual control. It now has been empirically determined for rotation axes oblique to canonical body axes and is compared with the MEF previously measured for rotations about canonical axes. A targeting rule, called the Secant Rule, based on these earlier measurements is derived from a hypothetical process and shown to describe some of the data from three previous experiments. It explains the motion trajectories determined for rotations less than 65deg in purely kinematic terms without the need to appeal to a mental rotation process. Further analysis of this rule in three dimensions applied to oblique rotation axes leads to a somewhat surprising expectation that the difficulty posed by rotational misalignment should get harder as the required movement is shorter. This prediction is confirmed. Geometry underlying this rule also suggests analytic extensions for predicting more generally the difficulty of making movements in arbitrary directions subject to arbitrary misalignments.

rotated control frames↗

Atmospheric correlation-time measurements and effects on coherent Doppler lidar

The time for which the backscatter from an ensemble of atmospheric aerosol particles remains coherent was studied by using a pulsed TEA CO2 lidar with coherent detection. Experimental results are compared with predictions by using model pulse shapes appropriate for TEA CO2 laser transmitters. The correlation time of the backscatter return signal is important in studies of atmospheric turbulence and its effects on optical propagation and backscatter. Techniques for its measurement are discussed and evaluated.

Ancellet, Gerard M.↗

Solar Contamination in Extreme-precision Radial-velocity Measurements: Deleterious Effects and Prospects for Mitigation

Solar contamination, due to moonlight and atmospheric scattering of sunlight, can cause systematic errors in stellar radial velocity (RV) measurements that significantly detract from the ~10 cm/s sensitivity required for the detection and characterization of terrestrial exoplanets in or near habitable zones of Sun-like stars. The addition of low-level spectral contamination at variable effective velocity offsets introduces systematic noise when measuring velocities using classical mask-based or template-based cross-correlation techniques. Here we present simulations estimating the range of RV measurement error induced by uncorrected scattered sunlight contamination. We explore potential correction techniques, using both simultaneous spectrometer sky fibers and broadband imaging via coherent fiber imaging bundles, that could reliably reduce this source of error to below the photon-noise limit of typical stellar observations. We discuss the limitations of these simulations, the underlying assumptions, and mitigation mechanisms. We also present and discuss the components designed and built into the NEID (NN-EXPLORE Exoplanet Investigations with Doppler spectroscopy) precision RV instrument for the WIYN 3.5m telescope, to serve as an ongoing resource for the community to explore and evaluate correction techniques. We emphasize that while “bright time” has been traditionally adequate for RV science, the goal of 10 cm/s precision on the most interesting exoplanetary systems may necessitate access to darker skies for these next generation instruments.

Arpita Roy↗

Effect of measured material properties on the finite element analysis of an OH-58 composite tail boom

A static and dynamic finite element analysis is conducted on a U.S. Army OH-58 composite tail boom and compared with test data. The tail boom is a filament-wound graphite/epoxy monocoque structure. The structural design of the composite tail boom skin is based on 50-percent graphite fiber volume. However, material tests on representative samples of the tail boom skin reveal that the graphite fiber-volume fraction varied from 44.6 to 49.3 percent. To determine the effect of using measured material properties, static and dynamic finite element analyses are conducted for three fiber-volume conditions of 45, 48, and 50 percent. The static and dynamic model with the 45-percent fiber-volume graphite skins gives the closest agreement with test data.

Bowman, L. M.↗