Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “edge sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Antenna-coupled TES bolometers used in BICEP2, Keck Array, and Spider

We have developed antenna-coupled transition-edge sensor bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including Bicep2, Keck Array, and the balloon borne Spider. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%–30% bandwidth at 95, 150, or 230 GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ∼0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET ∼ 300 μK{sub CMB}√s. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ∼9 μK{sub CMB}√s, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the Spider instrument, and development of this technology is ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D active edge silicon sensors: Device processing, yield and QA for the ATLAS-IBL production

3D silicon sensors, where plasma micromachining is used to etch deep narrow apertures in the silicon substrate to form electrodes of PIN junctions, were successfully manufactured in facilities in Europe and USA. In 2011 the technology underwent a qualification process to establish its maturity for a medium scale production for the construction of a pixel layer for vertex detection, the Insertable B-Layer (IBL) at the CERN-LHC ATLAS experiment. The IBL collaboration, following that recommendation from the review panel, decided to complete the production of planar and 3D sensors and endorsed the proposal to build enough modules for a mixed IBL sensor scenario where 25% of 3D modules populate the forward and backward part of each stave. The production of planar sensors will also allow coverage of 100% of the IBL, in case that option was required. This paper will describe the processing strategy which allowed successful 3D sensor production, some of the Quality Assurance (QA) tests performed during the pre-production phase and the production yield to date.

47 OTHER INSTRUMENTATION↗

Pulse Tube Interference in Cryogenic Sensor Resonant Circuits (Final Paper)

Transition edge sensors (TES) are extremely sensitive superconducting sensors, operating at 100 mK, which can be used to detect X-rays and Cosmic Microwave Background. The goal of our project is to design the electronics to read out an array of 10000 of these sensors by using microwave signals. However, we noticed the pulse tube used to maintain cryogenic temperatures caused interference in our readout. To determine the cause of the signal distortions, we used a detector with a 370 MHz sampling rate to collect and analyze sensor data. Although this data provided little information towards the nature of the noise, it was determined through a maintenance procedure than the 0.3 mm stainless steel wires were being vibrated due to acoustic waves, which distorted the signal. Replacing this wire appeared to cease the interference from the sensor data.

42 ENGINEERING↗

Developing AlMn Films for Argonne TES Fabrication

The reference design for the next-generation cosmic microwave background (CMB) experiment, CMB-S4, relies on large arrays of transition-edge sensor (TES) bolometers coupled to Superconducting Quantum Interference Device (SQUID)-based readout systems. Mapping the CMB to near cosmic variance limits will enable the search for signatures of inflation and constrain dark energy and neutrino physics. AlMn TESes provide simple film manufacturing and highly uniform arrays over large areas to meet the requirements of the CMB-S 4 experiment. TES parameters such as critical temperature and normal resistance must be tuned to experiment specifications and can be varied based on geometry and steps in the fabrication process such as deposition layering, geometry, and baking time and temperature. Using four-terminal sensing, we measured T C and R N of AlMn 2000 ppm films and devices of varying thicknesses fabricated at Argonne National Laboratory to motivate device geometries and fabrication processes to tune T C to 150–200 mK and R N to ~10 mΩ. Furthermore, measurements of IV curves and time constants for the resulting devices of varying leg length were made using time-division SQUID multiplexing and determined TC, G, k, f 3db , and RN. We present the results of these tests along with the geometries and fabrication steps used to tune the device parameters to the desired limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ~2 m 2 of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

47 OTHER INSTRUMENTATION↗

Experimental Validation of Calorimetric Electron Capture Spectral Theory with 193 Pt

Using microcalorimeters, a high statistics, high-resolution calorimetric spectrum of electron capture in 163 Ho can be used to determine the neutrino mass. The spectral shape can be calculated from first principles with various assumptions and approximations. To determine the validity of these choices, the theoretical calculations must be compared to data from multiple isotopes. In this work, new calorimetric data for a 193 Pt-in-Pt absorber measured with a transition edge sensor are presented and compared to theoretical calculations and values from the literature.

74 ATOMIC AND MOLECULAR PHYSICS↗

Light Dark Matter Detection with Hydrogen-Rich Targets and Low-$T_c$ TES Detectors

Direct detection of nuclear scatterings of sub-GeV dark matter (DM) particles favors low-Z nuclei. Hydrogen nucleus, which has a single proton, provides the best kinematic match. The characteristic nuclear recoil energy is boosted by a factor of a few tens from those for larger nuclei used in traditional Weakly Interacting Massive Particles searches. Furthermore, hydrogen is optimal for detecting spin-dependent nuclear scatterings of sub-GeV DM, where large parameter space still remains unconstrained yet. In this paper, we first introduce several hydrogen-rich targets, which emit two classes of signals under kinetic excitations. One class of the signals is infrared photons, which are from fundamental vibrational and rotational modes of molecules and at several characteristic wavelengths. Another is acoustic phonons and optical phonons that decay into acoustic phonons. Then we discuss the technical status and future researches of low-T c transition-edge sensor (TES) detectors, which measure the infrared photons and acoustic phonons with desirable sensitivities. Utilization of hydrogen-rich targets and ultra-sensitive low-T c TES detectors for light DM detection requires both theoretical modeling and experimental prototyping.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic gamma detectors enable direct detection of 236 U and minor actinides for non-destructive assay [Cryogenic gamma detectors enable direct detection of minor actinides for non-destructive assay]

Here, we demonstrate the utility of a superconducting transition edge sensor (TES) γ-ray detector with high energy resolution and low Compton background for non-destructive assay (NDA) of a uranium sample from reprocessed nuclear fuel. We show that TES γ-detectors can separate low energy actinide γ-emissions from the background and nearby lines, even from minor isotopes whose signals are often obscured in NDA with conventional Ge detectors. Superconducting γ detectors may therefore bridge the gap between high-accuracy destructive assay (DA) and easier to-use NDA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Devices for Thermal Conductivity Measurements of Electroplated Bi for X-ray TES Absorbers

Electroplated bismuth (Bi) is commonly used in transition-edge sensors (TESs) for X-rays because of its high stopping power and low heat capacity (Collan in Phys Rev B 1:2888, 1970, Yan in Appl Phys Lett 111:192602, 2017). Electroplated Bi is usually grown on top of another metal that acts as seed layer, typically gold (Au), making it challenging to extrapolate its thermoelectric properties. In this work, we present four-wire resistance measurement structures that allow us to measure resistance as a function of temperature of electroplated Bi independently of Au. The results show that the thermal conductivity of the Bi at 3 K is high enough to ensure the correct thermalization of X-ray photons when used as an absorber for TESs.

Bismuth↗

Low Noise Frequency-Domain Multiplexing of TES Bolometers Using SQUIDs at Sub-Kelvin Temperature

Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of transition edge sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3 G with multiplexing factors as high as 68, and is the baseline readout technology for the planned satellite mission LiteBIRD. Here, we present recent work focused on improving DfMux readout noise, reducing parasitic impedance, and improving sensor operation. We have achieved a substantial reduction in stray impedance by integrating the sensors, resonators, and SQUID array onto a single-carrier board operated at 250 mK. This also drastically simplifies the packaging of the cryogenic components and leads to better-controlled crosstalk. We demonstrate a low readout noise level of 8.6 pA/Hz1 1/2 , which was made possible by operating the SQUID array at a reduced temperature and with a low dynamic impedance. This is a factor of two improvement compared to the achieved readout noise level in currently operating Cosmic Microwave Background experiments using DfMux and represents a critical step toward maturation of the technology for the next generation of instruments.

47 OTHER INSTRUMENTATION↗

Optically induced quantum transitions in direct probed mesoscopic NbSe 2 for prototypical bolometers

Superconducting transition-edge sensors (TES) have emerged as fascinating devices to detect broadband electromagnetic radiation with low thermal noise. The advent of metallic transition metal dichalcogenides, such as NbSe 2 , has also created an impetus to understand their low-temperature properties, including superconductivity. Interestingly, NbSe 2 -based sensor within the TES framework remains unexplored. In this work, direct-probed superconducting NbSe 2 absorbers led to a proof-of-concept demonstration for the transduction of incoming light to heat, where a thermodynamic superconducting phase transition in NbSe 2 was evident to switch it to the normal-state, when biased below its superconducting transition temperature. A wavelength-dependent response of its optical absorption properties was observed, based on the incident optical excitation source used. Furthermore, extensive optical characterization studies were conducted using Raman spectroscopy, where the in-plane and out-of-plane thermal conductivity was empirically determined. Our results open new possibilities for the use of NbSe 2 in superconducting radiation detectors, including in a TES framework

47 OTHER INSTRUMENTATION↗

Count Rate Optimizations for TES Detectors at a Femtosecond X-ray Laser

Transition-edge sensor microcalorimeters have found success as X-ray detectors at synchrotron light-sources, due to a unique combination of high collecting area and good energy resolution. However, the upcoming generation of free-electron lasers (FELs), such as the Linac Coherent Light Source II, is designed to deliver more than 10 10 photons in a 100 fs pulse at a 100 kHz rate, potentially leading to severe pulse-pileup issues. Here we will demonstrate that, for most relevant science cases, it is possible to mitigate pulse pile-up using simple X-ray filters in a way that takes advantage of the substantial increase in X-ray flux at modern FELs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthesis and Characterization of MoNb Films Superconducting at 100-200 mK

We have developed a new transition-edge sensor material with critical temperature (T-c) in the range 100-200 mK. The new material is a solid solution of two superconducting components, MoxNb1-x, co-sputtered from two high-purity single-component targets (Mo and Nb). The T-c has a minimum (dT(c)/dx = 0) at an intermediate concentration of the components. We have optimized the deposition parameters and composition to provide films with a sharp superconducting transition at ~ 150 mK. We investigated structural features of the films and surface morphology using X-ray diffraction (XRD) and scanning electron microscopy. The XRD measurements indicate that the grown films are polycrystalline, with a preferred orientation along the (110) crystal direction and a clear correlation between superconducting properties and film microstructure.

superconducting alloys↗

Performance of a low-parasitic frequency-domain multiplexing readout

Frequency-domain multiplexing is a readout technique for transition-edge sensor bolometer arrays used on modern cosmic microwave background experiments, including the SPT-3G receiver. Here, we present design details and performance measurements for a low-parasitic frequency-domain multiplexing readout. Reducing the parasitic impedance of the connections between cryogenic components provides a path to improve both the crosstalk and noise performance of the readout. Reduced crosstalk will in turn allow higher-multiplexing factors. We have demonstrated a factor of two improvement in parasitic resistance compared to SPT-3G hardware. Reduced parasitics also permits operation of lower-resistance bolometers optimized for improved readout noise performance. We demonstrate that a module in the prototype system has comparable readout noise performance to an SPT-3G module when operated with dark TES bolometers in the laboratory.

frequency-domain multiplexing↗

Measurement of 227 Ac impurity in 225 Ac using decay energy spectroscopy

225 Ac is a valuable medical radionuclide for targeted $\alpha$ therapy, but 227 Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227 Ac, with the 227 Ac/ 225 Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small changes in temperature. By embedding 225 Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and 100% detection efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from $\alpha$ decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss in this paper. Using this technique we measured the EOB 227 Ac impurity to be (0.142 ± 0.005)% for a single production sample. This demonstration has shown that DES is a useful tool for quantitative measurements of complicated spectra.

07 ISOTOPE AND RADIATION SOURCES↗

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗