Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Using Dynamic Quantum Clustering to Analyze Hierarchically Heterogeneous Samples on the Nanoscale

Dynamic Quantum Clustering (DQC) is an unsupervised, high visual data mining technique. DQC was tested as an analysis method for X-ray Absorption Near Edge Structure (XANES) data from the Transmission X-ray Microscopy (TXM) group. The TXM group images hierarchically heterogeneous materials with nanoscale resolution and large field of view. XANES data consists of energy spectra for each pixel of an image. It was determined that DQC successfully identifies structure in data of this type without prior knowledge of the components in the sample. Clusters and sub-clusters clearly reflected features of the spectra that identified chemical component, chemical environment, and density in the image. DQC can also be used in conjunction with the established data analysis technique, which does require knowledge of components present.

99 GENERAL AND MISCELLANEOUS↗

Laser Based In Situ Techniques: Novel Methods for Generating Extreme Conditions in TEM Samples

The Dynamic Transmission Electron Microscope (DTEM) is introduced as a novel tool for in situ processing of materials. Examples of various types of dynamic studies outline the advantages and differences of laser-based heating in the DTEM in comparison to conventional (resistive) heating in situ TEM methods. We demonstrate various unique capabilities of the drive laser, namely, in situ processing of nanoscale materials, rapid and high temperature phase transformations, and controlled thermal activation of materials. These experiments would otherwise be impossible without the use of the DTEM drive laser. Thus, the potential of the DTEM to as a new technique to process and characterize the growth of a myriad of micro and nanostructures is demonstrated.

36 MATERIALS SCIENCE↗

Structure of amorphous GeSe{sub 9} by neutron diffraction and first-principles molecular dynamics: Impact of trajectory sampling and size effects

The structure of glassy GeSe{sub 9} was investigated by combining neutron diffraction with density-functional-theory-based first-principles molecular dynamics. In the simulations, three different models of N = 260 atoms were prepared by sampling three independent temporal trajectories, and the glass structures were found to be substantially different from those obtained for models in which smaller numbers of atoms or more rapid quench rates were employed. In particular, the overall network structure is based on Se{sub n} chains that are cross-linked by Ge(Se{sub 4}){sub 1/2} tetrahedra, where the latter are predominantly corner as opposed to edge sharing. The occurrence of a substantial proportion of Ge–Se–Se connections does not support a model in which the material is phase separated into Se-rich and GeSe{sub 2}-rich domains. The appearance of a first-sharp diffraction peak in the Bhatia-Thornton concentration-concentration partial structure factor does, however, indicate a non-uniform distribution of the Ge-centered structural motifs on an intermediate length scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A stochastic covariance shrinkage approach to particle rejuvenation in the ensemble transform particle filter

Rejuvenation in particle filters is necessary to prevent the collapse of the weights when the number of particles is insufficient to properly sample the high-probability regions of the state space. Rejuvenation is often implemented in a heuristic manner by the addition of random noise that widens the support of the ensemble. This work aims at improving canonical rejuvenation methodology by the introduction of additional prior information obtained from climatological samples; the dynamical particles used for importance sampling are augmented with samples obtained from stochastic covariance shrinkage. A localized variant of the proposed method is developed. Numerical experiments with the Lorenz '63 model show that modified filters significantly improve the analyses for low dynamical ensemble sizes. Furthermore, localization experiments with the Lorenz '96 model show that the proposed methodology is extendable to larger systems.

54 ENVIRONMENTAL SCIENCES↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

Quantification of in-contact probe-sample electrostatic forces with dynamic atomic force microscopy

Here, atomic force microscopy (AFM) methods utilizing resonant mechanical vibrations of cantilevers in contact with a sample surface have shown sensitivities as high as few picometers for detecting surface displacements. Such a high sensitivity is harnessed in several AFM imaging modes. Here, we demonstrate a cantilever-resonance-based method to quantify electrostatic forces on a probe in the probe-sample junction in the presence of a surface potential or when a bias voltage is applied to the AFM probe. We find that the electrostatic forces acting on the probe tip apex can produce signals equivalent to a few pm of surface displacement. In combination with modeling, the measurements of the force were used to access the strength of the electrical field at the probe tip apex in contact with a sample. We find an evidence that the electric field strength in the junction can reach ca. 1 V nm –1 at a bias voltage of a few volts and is limited by non-ideality of the tip-sample contact. This field is sufficiently strong to significantly influence material states and kinetic processes through charge injection, Maxwell stress, shifts of phase equilibria, and reduction of energy barriers for activated processes. Besides, the results provide a baseline for accounting for the effects of local electrostatic forces in electromechanical AFM measurements as well as offer additional means to probe ionic mobility and field-induced phenomena in solids.

36 MATERIALS SCIENCE↗

Use of continuous sample translation to reduce radiation damage for XPCS studies of protein diffusion

An experimental setup to measure X-ray photon correlation spectroscopy during continuous sample translation is presented and its effectiveness as a means to avoid sample damage in dynamics studies of protein diffusion is evaluated. X-ray damage from focused coherent synchrotron radiation remains below tolerable levels as long as the sample is translated through the beam sufficiently quickly. Here it is shown that it is possible to separate sample dynamics from the effects associated with the transit of the sample through the beam. By varying the sample translation rate, the damage threshold level, D thresh = 1.8 kGy, for when beam damage begins to modify the dynamics under the conditions used, is also determined. Signal-to-noise ratios, R sn ≥ 20, are obtained down to the shortest delay times of 20 µs. The applicability of this method of data collection to the next generation of multi-bend achromat synchrotron sources is discussed and it is shown that sub-microsecond dynamics should be obtainable on protein samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A test cassette for x-ray-exposure experiments at the National Ignition Facility

We present the design and operation of a test cassette for exposure of samples to radiation environments at the National Ignition Facility. The cassette provides options for square and round samples and exposure areas; the cassette provides for multiple levels of filtration on a single sample, which allows dynamic range in experiments. The samples had normal lines of sight to the x-ray source in order to have uniform x-ray illumination. The incident x-radiation onto the samples was determined by the choice of filter thicknesses and materials. The samples were held at precise locations, accurate to within a few hundred microns, in the target chamber in order to have a known fluence incident. In the cassette, the samples were held in place in such a way that a minimal ''line contact'' allows them to have the maximal mechanical response to the x-ray load. We present postshot images of the debris found on films used for filters, and pre- and postexposure specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Supercomputer-Based Ensemble Docking Drug Discovery Pipeline with Application to Covid-19

In this work, we present a supercomputer-driven pipeline for in silico drug discovery using enhanced sampling molecular dynamics (MD) and ensemble docking. Ensemble docking makes use of MD results by docking compound databases into representative protein binding-site conformations, thus taking into account the dynamic properties of the binding sites. We also describe preliminary results obtained for 24 systems involving eight proteins of the proteome of SARS-CoV-2. The MD involves temperature replica exchange enhanced sampling, making use of massively parallel supercomputing to quickly sample the configurational space of protein drug targets. Using the Summit supercomputer at the Oak Ridge National Laboratory, more than 1 ms of enhanced sampling MD can be generated per day. We have ensemble docked repurposing databases to 10 configurations of each of the 24 SARS-CoV-2 systems using AutoDock Vina. Comparison to experiment demonstrates remarkably high hit rates for the top scoring tranches of compounds identified by our ensemble approach. We also demonstrate that, using Autodock-GPU on Summit, it is possible to perform exhaustive docking of one billion compounds in under 24 h. Finally, we discuss preliminary results and planned improvements to the pipeline, including the use of quantum mechanical (QM), machine learning, and artificial intelligence (AI) methods to cluster MD trajectories and rescore docking poses.

60 APPLIED LIFE SCIENCES↗

Computational Fluid Dynamics Modeling to Facilitate Qualification of Stack Sampling Probe Location

Computational fluid dynamics (CFD) modeling was used to help evaluate modifications to a radiological effluent stack and assist with establishing a stack sampling location that met the mixing criteria for qualification. Requirements for stack sampling location are listed in the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-2021 standard. Modeling was performed to help develop a suitable design for increasing building ventilation for the radiological effluent stack. The ANSI/HPS N13.1-2021 criteria for the air monitoring probe location are that the coefficient of variation of velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20 degrees. The ANSI/HPS N13.1-2021 standard allows for models (physical or computational) to be employed to perform the full suite of qualification tests, followed by a more limited set of verification tests on the actual stack to qualify the stack sampling location. Here, a series of computational model simulations were employed to evaluate the stack qualification criteria. Significant time and re-source savings are achieved using CFD modeling. CFD modeling demonstrated that the stack meets the criteria at the sample probe location. Verification tests were performed on the modified stack to measure the velocity uniformity and flow angle at the stack sampling location, and results demonstrated that the CFD model results may be used to support the qualification of the stack sampling location.

Air Monitoring↗

Single-pulse x-ray diffraction using polycapillary optics for in situ dynamic diffraction

Diagnostic use of single-pulse x-ray diffraction (XRD) at pulsed power facilities can be challenging due to factors such as the high flux and brightness requirements for diffraction and the geometric constraints of experimental platforms. By necessity, the x-ray source is usually positioned very close, within a few inches of the sample. On dynamic compression platforms, this puts the x-ray source in the debris field. We coupled x-ray polycapillary optics to a single-shot needle-and-washer x-ray diode source using a laser-based alignment scheme to obtain high-quality x-ray diffraction using a single 16 ns x-ray pulse with the source >1 m from the sample. Additionally, the system was tested on a Mo sample in reflection geometry using 17 keV x-rays from a Mo anode. We also identified an anode conditioning effect that increased the x-ray intensity by 180%. Quantitative measurements of the x-ray focal spot produced by the polycapillary yielded a total x-ray flux on the sample of 3.3 ± 0.5 × 10 7 molybdenum Kα photons.

47 OTHER INSTRUMENTATION↗

Chaotic neural dynamics facilitate probabilistic computations through sampling

Cortical neurons exhibit highly variable responses over trials and time. Theoretical works posit that this variability arises potentially from chaotic network dynamics of recurrently connected neurons. Here, we demonstrate that chaotic neural dynamics, formed through synaptic learning, allow networks to perform sensory cue integration in a sampling-based implementation. We show that the emergent chaotic dynamics provide neural substrates for generating samples not only of a static variable but also of a dynamical trajectory, where generic recurrent networks acquire these abilities with a biologically plausible learning rule through trial and error. Furthermore, the networks generalize their experience in the stimulus-evoked samples to the inference without partial or all sensory information, which suggests a computational role of spontaneous activity as a representation of the priors as well as a tractable biological computation for marginal distributions. These findings suggest that chaotic neural dynamics may serve for the brain function as a Bayesian generative model.

60 APPLIED LIFE SCIENCES↗

HYDROSTATIC GAS CONSTRAINTS ON SUPERMASSIVE BLACK HOLE MASSES: IMPLICATIONS FOR HYDROSTATIC EQUILIBRIUM AND DYNAMICAL MODELING IN A SAMPLE OF EARLY-TYPE GALAXIES

We present new mass measurements for the supermassive black holes (SMBHs) in the centers of three early-type galaxies. The gas pressure in the surrounding, hot interstellar medium (ISM) is measured through spatially resolved spectroscopy with the Chandra X-ray Observatory, allowing the SMBH mass (M {sub BH}) to be inferred directly under the hydrostatic approximation. This technique does not require calibration against other SMBH measurement methods and its accuracy depends only on the ISM being close to hydrostatic, which is supported by the smooth X-ray isophotes of the galaxies. Combined with results from our recent study of the elliptical galaxy NGC 4649, this brings the number of galaxies with SMBHs measured in this way to four. Of these, three already have mass determinations from the kinematics of either the stars or a central gas disk, and hence join only a handful of galaxies with M {sub BH} measured by more than one technique. We find good agreement between the different methods, providing support for the assumptions implicit in both the hydrostatic and the dynamical models. The stellar mass-to-light ratios for each galaxy inferred by our technique are in agreement with the predictions of stellar population synthesis models assuming a Kroupa initial mass function (IMF). This concurrence implies that no more than {approx}10%-20% of the ISM pressure is nonthermal, unless there is a conspiracy between the shape of the IMF and nonthermal pressure. Finally, we compute Bondi accretion rates (M-dot{sub bondi}), finding that the two galaxies with the highest M-dot{sub bondi} exhibit little evidence of X-ray cavities, suggesting that the correlation with the active galactic nuclei jet power takes time to be established.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid sampling of stochastic displacements in Brownian dynamics simulations

Here, we present a new method for sampling stochastic displacements in Brownian Dynamics (BD) simulations of colloidal scale particles. The method relies on a new formulation for Ewald summation of the Rotne-Prager-Yamakawa (RPY) tensor, which guarantees that the real-space and wave-space contributions to the tensor are independently symmetric and positive-definite for all possible particle configurations. Brownian displacements are drawn from a superposition of two independent samples: a wave-space (far-field or long-ranged) contribution, computed using techniques from fluctuating hydrodynamics and non-uniform fast Fourier transforms; and a real-space (near-field or short-ranged) correction, computed using a Krylov subspace method. The combined computational complexity of drawing these two independent samples scales linearly with the number of particles. The proposed method circumvents the super-linear scaling exhibited by all known iterative sampling methods applied directly to the RPY tensor that results from the power law growth of the condition number of tensor with the number of particles. For geometrically dense microstructures (fractal dimension equal three), the performance is independent of volume fraction, while for tenuous microstructures (fractal dimension less than three), such as gels and polymer solutions, the performance improves with decreasing volume fraction. This is in stark contrast with other related linear-scaling methods such as the force coupling method and the fluctuating immersed boundary method, for which performance degrades with decreasing volume fraction. Calculations for hard sphere dispersions and colloidal gels are illustrated and used to explore the role of microstructure on performance of the algorithm. In practice, the logarithmic part of the predicted scaling is not observed and the algorithm scales linearly for up to 4×10 6 particles, obtaining speed ups of over an order of magnitude over existing iterative methods, and making the cost of computing Brownian displacements comparable to the cost of computing deterministic displacements in BD simulations. Finally, a high-performance implementation employing non-uniform fast Fourier transforms implemented on graphics processing units and integrated with the software package HOOMD-blue is used for benchmarking.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Level Understanding of the Free Energy Landscape in Early Stages of Metal-Organic Framework Nucleation

The assembly mechanism of hierarchical materials controlled by the choice of solvent and presence of spectator ions. In this paper, we use enhanced sampling molecular dynamics methods to investigate these effects on the configurational landscape of metal-linker interactions in the early stages of synthesis, using MIL-101(Cr) as a prototypical example. Microsecond-long well-tempered metadynamics (WTmetaD) uncover a complex free energy structural landscape, with distinct crystal (C) and non-crystal (NC) like configurations and their equilibrium population. In presence of ions (Na+, F-), we observe a complex effect on the crystallinity of secondary building units (SBUs), by encouraging/suppressing salt bridges between C configurations and consequently controlling the percentage of defects. Solvent effects are assessed by introducing N, N-dimethylformamide (DMF) instead of water, where SBU adducts are appreciably more stable and compact. These results shed light on how solvent nature and ionic strength impact the free energy of nucleation phenomena that ultimately control materials synthesis and defect formation. The work described in this publication was supported by the US Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences and performed at Pacific Northwest National Laboratory (PNNL). The authors acknowledge the use of the UCL Legion High Performance Computing Facility (Legion @ UCL) and associated support services in the completion of this work. This research used resources of the National Energy Research Scientific Computing Centre, a DOE Office of Science User Facility. Battelle operates PNNL for DOE under Contract DE-AC05-76RL01830.

Kollias, Loukas↗

Electrical conductivity of Sn at high pressure and temperature

To date, temperature and conductivity have many outstanding implications in extreme environments but are yet to be fully understood under high pressure and temperature dynamic conditions. Here, we introduce an approach to provide high quality electrical conductivity results under dynamic loading conditions. Emphasis is given to address the skin depth effect's influence in a dynamic loading experiment by using thin films. The thin film samples in this study were at least 100 times thinner than previous samples in dynamic electrical conductivity experiments, increasing the current density to its full potential across the sample's entire cross section. Consideration of the skin depth accounts for at minimum a 4× scaling factor to the final electrical conductivity result that has been neglected in previous dynamic electrical conductivity studies. We also obtained improved signal-to-noise ratio with custom diagnostics optimized for better electrical impedance matching. Furthermore, these considerations were applied to Sn to assess electrical conductivity at elevated pressure and temperature. The high signal-to-noise ratio with reduced skin depth influence results in Sn allowing observation of the conductivity changes related to solid-to-solid and solid-to-liquid phase transitions. Additionally, we calculate the Sn thermal conductivity using the Wiedemann-Franz law for our experiments and compare against thermal transport dependent temperature measurements from previous work.

36 MATERIALS SCIENCE↗

Development of a Data Acquisition System for Kinetic Inductance Detectors: Wide Dynamic Range and High Sampling Rate for Astronomical Observation

Microwave kinetic inductance detectors have a variety of potential applications in astronomical observations. We built a data acquisition system for kinetic inductance detectors combining a dedicated analog board and a commercially available digital board to meet the requirements of astronomical measurements, such as observation of the cosmic microwave background. This paper reports the status of the development of the data acquisition system. We have already achieved simultaneous readout through 120 channels using a direct down-conversion method to decode the signal. A variety of software has been developed and tested using the functionalities of the system and actual detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗