Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “double pulse test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection efficiency, wavelength response and communication performance data for these detectors. We successfully measured real-time communication performance using both the 2 detected-photon threshold and AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects. The HgCdTe APD array routinely demonstrated photon detection efficiencies of greater than 50% across 5 arrays, with one array reaching a maximum PDE of 70%. We performed high-resolution pixel-surface spot scans and measured the junction diameters of its diodes. We found that decreasing the junction diameter from 31 micrometers to 25 micrometers doubled the e- APD gain from 470 for an array produced in the year 2010 to a gain of 1100 on an array delivered to NASA GSFC recently. The mean single-photon SNR was over 12 and the excess noise factors measurements were 1.2-1.3. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output.

Photons↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three Three-Year Aging of Prototype Flight Laser at 10 kHz and 1 ns Pulses With External Frequency Doubler for ICESat-2 Mission

We present the results of three year life-aging of a specially designed prototype flight source laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and external frequency doubler. The Fibertek-designed, slightly pressurized air, enclosed-container source laser operated at 1064 nm in active Q-switching mode. The external frequency doubler was set in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm discreetly. The external frequency doubler consisted of a Lithium triborate, LiB3O5, crystal operated at non-critical phase-matching. Due to 1064 nm diagnostic needs, the amount of fundamental frequency power available for doubling was 13.7W. The power generated at 532 nm was between 8.5W and 10W, depending on the level of stress and degradation. The life-aging consisted of double stress-step operation for doubler crystal, at 0.35 Jcm2 for almost 1 year, corresponding to normal conditions, and then at 0.93 Jcm2 for the rest of the experiment, corresponding to accelerated testing. We observed no degradation at the first step and linear degradation at the second step. The linear degradation at the second stress-step was related to doubler crystal output surface changes and linked to laser-assisted contamination. We discuss degradation model and estimate the expected lifetime for the flight laser at 532 nm. This work was done within the laser testing for NASAs Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.

Lidar↗

Three Year Aging of Prototype Flight Laser at 10 Khz and 1 Ns Pulses with External Frequency Doubler for the Icesat-2 Mission

We present the results of three year life-aging of a specially designed prototype flight source laser operating at 1064 nm, 10 kHz, 1ns, 15W average power and external frequency doubler. The Fibertek-designed, slightly pressurized air, enclosed-container source laser operated at 1064 nm in active Q-switching mode. The external frequency doubler was set in a clean room at a normal air pressure. The goal of the experiment was to measure degradation modes at 1064 and 532 nm discreetly. The external frequency doubler consisted of a Lithium triborate, LiB3O5, crystal operated at non-critical phase-matching. Due to 1064 nm diagnostic needs, the amount of fundamental frequency power available for doubling was 13.7W. The power generated at 532 nm was between 8.5W and 10W, depending on the level of stress and degradation. The life-aging consisted of double stress-step operation for doubler crystal, at 0.35 J/cm2 for almost 1 year, corresponding to normal conditions, and then at 0.93 J/cm2 for the rest of the experiment, corresponding to accelerated testing. We observed no degradation at the first step and linear degradation at the second step. The linear degradation at the second stress-step was related to doubler crystal output surface changes and linked to laser-assisted contamination. We discuss degradation model and estimate the expected lifetime for the flight laser at 532 nm. This work was done within the laser testing for NASA's Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) LIDAR at Goddard Space Flight Center in Greenbelt, MD with the goal of 1 trillion shots lifetime.

Frequency Doubling↗

Solar Array in Simulated LEO Plasma Environment

Six different types of solar arrays have been tested in large vacuum chambers. The low earth orbit plasma environment was simulated in plasma vacuum chambers, where the parameters could be controlled precisely. Diagnostic equipment included spherical Langmuir probes, mass spectrometer, low-noise CCD camera with optical spectrometer, video camera, very sensitive current probe to measure arc current, and a voltage probe to register variations in a conductor potential. All data (except video) were obtained in digital form that allowed us to study the correlation between external parameters (plasma density, additional capacitance, bias voltage, etc) and arc characteristics (arc rate, arc current pulse width and amplitude, gas species partial pressures, and intensities of spectral lines). Arc inception voltages, arc rates, and current selections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness cases the increase in arc inception voltage. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 micron coverglass thickness and 60 V for the sample with 150 micron coverglass thickness. Installation of cryogenic pump in large vacuum chamber provided the possibility of considerable outgassing of array surfaces which resulted in significant decrease of arc rate. Arc sites were determined by employing a video-camera, and it is shown that the most probable sites for arc inception are triple-junctions, even though some arcs were initiated in gaps between cells. It is also shown that the arc rate increases with increasing of ion collection current. The analysis of optical spectra (240-800 nm) reveals intensive narrow atomic lines (Ag, H) and wide molecular bands (OH, CH, SiH, SiN) that confirms a complicated mechanism of arc plasma generation. The results obtained seem to be important for the understanding of the arc inception mechanism, which is absolutely essential for progress toward the design of high-voltage solar array for space application.

Vayner, Boris↗

Solar Array in Simulated LEO Plasma Environment

Six different types of solar arrays have been tested in large vacuum chambers. The low Earth orbit plasma environment was simulated in plasma vacuum chambers, where the parameters could be controlled precisely. Diagnostic equipment included spherical Langmuir probes, mass spectrometer, low-noise CCD camera with optical spectrometer, video camera, very sensitive current probe to measure arc current, and a voltage probe to register variations in a conductor potential. All data (except video) were obtained in digital form that allowed us to study the correlation between external parameters (plasma density, additional capacitance, bias voltage, etc) and arc characteristics (arc rate, arc current pulse width and amplitude, gas species partial pressures, and intensities of spectral lines). Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness causes the increase in arc inception voltage. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 m coverglass thickness and 60 V for the sample with 150 m coverglass thickness. Installation of cryogenic pump in large vacuum chamber provided the possibility of considerable outgassing of array surfaces which resulted in significant decrease of arc rate. Arc sites were determined by employing a video-camera, and it is shown that the most probable sites for arc inception are triple-junctions, even though some arcs were initiated in gaps between cells. It is also shown that the arc rate increases with increasing of ion collection current. The analysis of optical spectra (240-800 nm) reveals intensive narrow atomic lines (Ag, H) and wide molecular bands (OH, CH, SiH, SiN) that confirms a complicated mechanism of arc plasma generation. The results obtained seem to be important for the understanding of the arc inception mechanism, which is absolutely essential for progress toward the design of high-voltage solar array for space application.

Vayner, Boris↗

Spallation Neutron Source Proton Power Upgrade (PPU) Project: Lessons Learned for CD-4

The SNS PPU project goals were to design, build, install and test the equipment necessary to double the accelerator power from 1.4 MW to 2.8 MW and to deliver a 2.0 MW qualified target. PPU also included the provision of a stub-out in the SNS accumulator-ring-to-target tunnel to facilitate a rapid connection to a new proton beamline for the Second Target Station (STS) project. The power capability was doubled by increasing the proton beam energy by 33% and the peak beam current by 50%, relative to pre-PPU accelerator performance. The project also included modifications to some buildings and services. The PPU project accomplished the energy upgrade by fabricating and installing new superconducting radiofrequency (RF) cryomodules, with supporting RF equipment, in the existing linac tunnel and klystron gallery, respectively. The High Voltage Converter Modulators (HVCM) and klystrons for some of the existing installed RF equipment were upgraded to handle the higher beam current. The increased beam power of 2 MW on the First Target Station (FTS) was enabled by the addition of a new high-volume gas injection system for pressure pulse and cavitation mitigation in the mercury target and a redesigned mercury target vessel.

43 PARTICLE ACCELERATORS↗

Enhancing corrosion resistance of lightweight metal alloys through laser shock peening

In this study, we investigated the effects of laser shock peening (LSP) on the corrosion resistance of lightweight metal alloys, specifically AA6061 and AZ31. LSP was performed underwater, using a nanosecond pulse laser and without using a protective coating or layer on the workpiece. The corrosion behaviors of these alloys were analyzed through electrochemical tests, including open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization measurements. The results demonstrated that LSP significantly improved the polarization resistance, and higher laser power intensities led to increased corrosion resistance and reduced corrosion rates. This enhancement in anti-corrosion performance is attributed to the formation of a protective oxide layer on the surface, acting as a barrier against corrosion. In conclusion, the findings underscore the potential of laser surface treatment as a viable technique for enhancing the corrosion resistance of lightweight metal alloys.

36 MATERIALS SCIENCE↗

Contrasting the characteristics of atmospheric pressure plasma jets operated with single and double dielectric material: physicochemical characteristics and application to bacterial killing

Abstract This study reports an experimental comparison of two types of atmospheric pressure plasma jets in terms of their fundamental plasma characteristics and efficacy in bacterial sterilization. The plasma jets are fabricated by inserting a high voltage electrode inside a one-end closed (double DBD plasma jet) or both ends open (single DBD plasma jet) quartz tubes which are further enclosed inside a second quartz tube containing a ground electrode. Both plasma jets are operated in contact with water surface by using a unipolar pulsed DC power supply with helium as the working gas. Results from electrical and time-resolved imaging show that the single DBD configuration induces 3–4 times higher accumulation of charges onto the water surface with significantly faster propagation of plasma bullets. These results are accompanied by the higher discharge intensity as well as stronger emissions from short-lived reactive species which were analyzed through optical emission spectroscopy at the plasma-water interface. The rotational temperature for the single DBD configuration was observed to be higher making it unsafe for direct treatments of sensitive biological targets. These characteristics of the single DBD configuration result in the production of more than two times higher concentration of H 2 O 2 in plasma activated water. Shielding of the HV electrode reduces the plasma potential which in turn reduces the electric field & electron energy at the plasma-water interface. The reduced electric field for the double DBD configuration was lower by ≈463 Td than the single DBD configuration. The bactericidal efficacy of the two configurations of the plasma jets were tested against Escherichia coli , a well studied Gram-negative bacterium that can be commensal and pathogenic in human body. Our results demonstrate that although single DBD plasma jet result in stronger antibacterial effects, the double DBD configuration could be safer.

Physics↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Stability and Heat Transfer Characteristics of Condensing Films

The overall objective of this research is to investigate the fundamental physics of film condensation in reduced gravity. The condensation of vapor on a cool surface is important in many engineering problems,including spacecraft thermal control and also the behavior of condensate films that may form on the interior surfaces of spacecraft. To examine the effects of body force on condensing films, two different geometries have been tested in the laboratory: (1) a stabilizing gravitational body force (+1g, or condensing surface facing 'upwards') and (2) de-stabilizing gravitational body force (-1g, or 'downwards'). For each geometry, different fluid configurations are employed to help isolate the fluid mechanical and thermal mechanisms operative in condensing films. The fluid configurations are (a) a condensing film, and (b) a non-condensing film with film growth by mass addition by through the plate surface. Condensation experiments are conducted in a test cell containing a cooled copper or brass plate with an exposed diameter of 12.7 cm. The metal surface is polished to allow for double-pass shadowgraph imaging, and the test surface is instrumented with imbedded heat transfer gauges and thermocouples. Representative shadowgraph images of a condensing, unstable (-1g) n-pentane film are shown. The interfacial disturbances associated with the de-stabilizing body force leading to droplet formation and break-off can be clearly seen. The heat transfer coefficient associated with the condensing film is shown. The heat transfer coefficient is seen to initially decrease, consistent with the increased thermal resistance due to layer growth. For sufficiently long time, a steady value of heat transfer is observed, accompanied by continuous droplet formation and break-off. The non-condensing cell consists of a stack of thin stainless steel disks 10 cm in diameter mounted in a brass enclosure. The disks are perforated with a regular pattern of 361 holes each 0.25 mm in diameter. Non-condensing experiments in -1g have employed 50 cSt and 125 cSt silicone oil pumped through the perforated disks at a specified rate by a syringe micropump. The time to droplet break-off and the disturbance wavelengths appear to decrease with increasing pumping rate. The ability to reliably perform multi-point, ultrasonic measurements of the film thickness has been demonstrated. A linear array of eight transducers of 6 mm diameter (with a beam footprint of comparable size) are pulsed with a square-wave signal at a frequency of 5 MHz and a pulse duration of approximately 0.3 s. For thin films (60 m to 2-3 mm in thickness) the layer thickness is determined by frequency analysis, where the received ultrasound pulse is Fourier transformed and the spacing between the peaks in the frequency spectrum is analyzed. For thicker layers (up to at least 1 cm in thickness), time-domain analysis is performed of the received ultrasound pulses to generate directly the layer thickness. A time-trace of the film thickness at a point using a single transducer in the linear array is shown for the case of an unstable (-1g) n-pentane film. The oscillations in film thickness are evidently due to the passage and/or shedding of droplets from the cooled plate surface. The entire transducer array was used to measure the changes in film thickness resulting from the passage of gravity waves generated either by an oscillating wall or the impact of a single droplet on the free surface of a film. The enclosure in both cases was 14 cm square and the transducer spacing was 12 mm. Best results were obtained using as test fluid a mixture of 50% glycerol and 50% water with a fluid layer thickness of 3-5 mm. In both cases the measured wavelengths and wave propagation speeds using the ultrasound technique compared reasonably well with those observed by optical imaging. Additional information can be found in the original extended abstract.

Hermanson, J. C.↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of an Ozone DIAL Receiver for Operation on an Unpiloted Atmospheric Vehicle

Laser remote sensing from aircraft has become a very important technique for observing ozone in the environment. NASA Langley has an active aircraft based research program which presently uses Nd:YAG-pumped dye lasers that are then doubled into the UV to probe both the stratosphere and troposphere for ozone using the differential absorption lidar (DIAL) technique. This large system can only fly on large (NASA DC-8, Electra) aircraft and has been deployed on many missions throughout the world. In the future it will be desirable to fly autonomous, lightweight, compact ozone DIAL instruments on unpiloted atmospheric vehicles (UAV) aircraft. Such aircraft could fly at high altitudes for extended times collecting science data without risk to the operator. Cost for such missions may be substantially reduced over present large aircraft based missions. Presently there are no ozone DIAL systems capable of flying on an UAV aircraft. In order to facilitate UAV missions, small more efficient laser transmitters need to be developed that emit approximately 25mJ near 300nm for each of the DIAL 'on' and 'off' line pulses. Also lightweight, compact DIAL receiver systems need to be built and demonstrated. Such receiver systems may incorporate fiber optic coupled telescopes for maximum light gathering capability per unit area, high quantum efficiency gated photomultiplier tubes with reasonable gain and very narrow-band filters for background light rejection with high light throughput. A compact high-performance 16-bit digitizer and a data storage system are also required. A conceptional design of such a UAV DIAL instrument is presented. Here a pulsed UV laser emits pulses into the atmosphere where elastic scattering occurs which results in light being scattered into the receiver telescope. The subject of this paper is the design, construction and testing of a robust, compact ozone DIAL receiver system that would be a prototype for eventual use in a UAV aircraft.

Goldschmidt, Soenke↗

Laser diagnostics for microgravity droplet studies

An instrument has been designed, built, and tested for performing laser diagnostic measurements of droplet combustion in low-gravity-flight aircraft. Nonintrusive measurements are of particular importance for droplet combustion (the simplest example of non-premixed combustion) and transport in microgravity environments, where physical contact would introduce an unacceptable level of perturbations. The resolution of these diagnostics can also isolate transport to length scales much smaller than the droplet diameter. These techniques can be configured to instantaneously map an entire flow field in two and three dimensions, providing either qualitative or quantitative information on the distribution of a desired scalar or vector quantity. Detailing the gas-phase flow field and position of the flame front can be achieved using planar laser-induced fluorescence (PLIF) of OH or another flame front marker. An alternative approach is to obtain LIF from a diagnostic seed included in the liquid phase fuel; it would be consumed at the flame front. The main advantage to this approach is that it is easier to choose the wavelength of the molecular absorption which coincides with convenient laser wavelengths rather than finding lasers which can be configured to access OH. Our present method uses a nitrogen-pumped dye laser tuned to a sodium absorption and addition of small concentrations of NaCl to the fuel. Particle image velocimetry (PIV) is a laser-based technique which has recently had its practicality greatly enhanced by the development of high-resolution CCD cameras and the increase in speed and capacity of computer systems. With this technique, a seeded flow is illuminated with a double-pulsed laser sheet to generate a double exposure image on a film or CCD camera. Computer analysis of the image is used to determine the particle velocity vectors and, thus, the gas velocity within the plane of the laser sheet. Our current experiment uses PIV for measuring relative droplet gas-phase velocities in a parabolic flight environment. The results show successful application of PLIF relative to luminosity and radical emission near 308 nm. PIV results are less successful due to gas thermal expansion deflecting the seed particles away from the measurement volume. PIV is applicable for measurements in the absence of combustion.

Winter, Michael↗

Small Orbital Debris Mitigation Mission Architecture

Small orbital debris in LEO (1-10 cm in size) presents a clear and present danger to operational LEO spacecraft. This debris field has dramatically increased (nearly doubled) in recent years following the Chinese ASAT Test in 2007 and the Iridium/Cosmos collision in 2009. Estimates of the number of small debris have grown to 500,000 objects after these two events; previously the population was 300,000 objects. These small, untracked debris objects (appproximately 500,000) outnumber the larger and tracked objects (appproximately 20,000) by a factor 25 to 1. Therefore, the risk of the small untracked debris objects to operational spacecraft is much greater than the risk posed by the larger and tracked LEO debris objects. A recent study by The Aerospace Corporation found that the debris environment will increase the costs of maintaining a constellation of government satellites by 5%, a constellation of large commercial satellites by 11%, and a constellation of factory built satellites by 26% from $7.6 billion to $9.57 billion. Based upon these facts, the NASA Marshall Space Flight Center (MSFC) Advanced Concepts Office (ACO) performed an architecture study on Small Orbital Debris Active Removal (SODAR) using a space-based nonweapons- class laser satellite for LEO debris removal. The goal of the SODAR study was to determine the ability of a space-based laser system to remove the most pieces of debris (1 cm to 10 cm, locations unknown), in the shortest amount of time, with the fewest number of spacecraft. The ESA developed MASTER2005 orbital debris model was used to probabilistically classify the future debris environment including impact velocity, magnitude, and directionality. The study ground rules and assumptions placed the spacecraft into a high inclination Low Earth Orbit at 800 km as an initial reference point. The architecture study results found that a spacecraft with an integrated forward-firing laser is capable of reducing the small orbital debris flux within a 60 to 100 km orbital shell by a significant amount within the one spacecraft's operational lifetime. The technology developments required for such an architecture to be successfully employed are: 1) A pico-pulsed, space qualified laser and 2) The ability to detect and track a small LEO small debris object from a space based platform. Therefore, a conceptual design for a demonstration satellite to showcase the ability to detect and track small orbital debris was completed

Wiegmann, Bruce M.↗

Study of the Mu2e sensitivity to the $\mu^-\rightarrow e^+$ conversion process

The Mu2e experiment at Fermilab (Batavia, IL) will search for the coherent neutrinoless conversion of a muon into an electron in the electric field of an aluminum atom. The conversion process results in a monochromatic electron with energy slightly below the muon rest mass ($E_e= 104.97$ MeV). The experiment goal is to improve the previous measurement by four orders of magnitude and reach a single event sensitivity of $3 \times 10^{-17} $ on the conversion rate with respect to the muon capture rate. \\ The experiment will deliver a very intense pulsed negative muon beam to an aluminum target to achieve a total number of $10^{18}$ stopped muons in three years of running. Production and transport of the muons are accomplished with a sophisticated magnetic system comprised of a Production, a Transport and a Detector solenoid, with the last one hosting a Straw-tube Tracker and a Crystal Calorimeter. The entire detector region is surrounded by a Cosmic Ray Veto system. Mu2e is und er construction at the Muon Campus of Fermilab. \\ The INFN italian group is responsible for the design and construction of the crystal calorimeter, which plays a crucial role in the Mu2e measurement, providing particle identification capabilities fundamental for the rejection of the different background sources that can mimic a conversion electron. The calorimeter information allows also to improve the tracking performances it provides a fast standalone trigger for the experiment.\\ After a long R\&D phase, the final drawings see a calorimeter comprised of 1348 pure CsI crystals arranged in two annular disks. Each crystal is readout by two custom UV-extended Silicon Photomultipliers (SiPMs). Performances of the selected components were verified with an electron beam test, carried out in 2017 at the Beam Test Facility (BTF) at the National Laboratories of Frascati, on a large size prototype of 51 crystals and 102 SiPMs, confirming excellent energy ($\sigma_{E}/E = \mathcal{O }(10\%)$) and timing ($\sigma_{T} <500$ ps) resolutions in a! greement with the Mu2e specifications.\\ In the first chapters of this thesis, I describe my involvement in the calorimeter activities, with particular emphasis on the data analysis of the prototype energy response and resolution, that I was personally leading. Moreover, a description of the tuning of the simulation and the careful data-MC comparison is also reported.\\ An auxiliary measurement that can be performed with Mu2e is the search for a Lepton Number Violation (LNV) process where the negatively charged muon converts, without neutrinos, into a positron, $\mu ^{-} +N(A,Z) \rightarrow $ e$^+ +N(A,Z-2)$. At the moment of writing, Neutrinoless Double Beta Decay (0$\nu \beta \beta$) has set the most stringent limit on the LNV processes (T$^{0\nu \beta \beta}_{1/2} > 1.1 \times 10^{26} $ yr at 90$\%$ CL) with the GERDA experiment. In 0$\nu \beta \beta$ a pair of free electrons is created in the transformation from a nucleus $(A, Z)$ into its daughter $(A, Z + 2)$, namely: $(A,Z)\rightarrow (A, Z+2) =2 e^-$. Similar transitions could proceed through the emission of a pair of positrons, double electron capture (EC), or EC and single emission of a positron, with the nucleus changing from $(A, Z)$ to $(A, Z - 2)$. All these variations are equally interesting when discussing of new Physics, since they all manifest a non-conservation of the number of leptons.\\ Moreover, recent studies show that, because of flavor effect, off-diagonal processes, such as the $\mu^- -e^+$ conversion, can have their rate enhanced with respect to processes occurring in the $e-e$ sector.\\ Mu2e will search for $\mu^- + Al(27,13) \rightarrow e^+ +Na(27,11)$, only considering ground state transition, producing a conversion positron with energy $E_{e^+}= 92.32 $ MeV.\\ This thesis is focused on this search. In particular, I developed an algorithm to account for the radiative corrections to be applied to the conversion positrons that resulted in a few percent reduction in s ignal acceptance.\\ One of the most prominent background to ! this sear! ch is the Radiative Muon Capture (RMC) $ \mu+ N(Z,A)\rightarrow \gamma + \nu_{\mu} + N(Z-1,A)$. The produced photon can convert, virtually or in the detector materials (in the following referred as internal or external conversion respectively) in an electron-positron pair, producing positrons with energies approaching the expected conversion energy. Experimental results from previous experiments indicate the RMC endpoint ($\kmax$) to be of $\sim$ 90 MeV. A precise modeling of this background is relevant due to the proximity of the photon spectrum endpoint to the positron conversion energy. The calorimeter group is obviously interested to reconstruct the RMC distribution having also the opportunity to improve the current knowledge of the process. \\ A toy MC has been developed to evaluate the number of $e^+$ from external RMC background in the signal window. Knowing this value and ev...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

47 OTHER INSTRUMENTATION↗