Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “district energy modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

Optimizing Cornell’s future geothermal district heating performance through systems engineering and simulation

Cornell University’s intention to lower its carbon footprint has motivated this engineering evaluation of using low-temperature geothermal energy to supply heat to the campus district energy system. Optimal selection and operation of heat pumps can significantly improve system performance. To support this analysis, we model the quantitative relationships between heat pump configurations and source flow, supply and distribution temperatures, facility heating design options, output heat generation, and carbon abatement outcomes. A systems approach is used for analysis, troubleshooting, and improvement of the model. The result of this effort is a dynamic tool that appropriately responds to hourly thermal demand and communicates energy response for techno-economic analysis. Simulations indicate that a single well-pair in the local Basement Contact Zone reservoir can satisfy almost 68% of annual thermal demand at nearly 20 MWth average capacity while remaining financially competitive compared to conventional heating with levelized cost of heating (LCOH) as low as $4.55/MMBTU ($15.53/MWh th ). A direct-use scheme with heat pump augmentation provided more carbon abatement and 50 to 150% more annual heat supply than one without augmentation. Exploration of three and four well-pair scenarios prove the capability to achieve 50 MW th baseload heating capacity with competitive LCOH and significant carbon reductions.

15 GEOTHERMAL ENERGY↗

A Case Study on Condenser Water Supply Temperature Optimization with a District Cooling Plant

District cooling (DC) continues to proliferate due to increasing global cooling demands and economies of scale benefits; however, most district-scale modeling has focused on heating, and to the best of our knowledge, researchers have yet to model cooling plants featuring waterside economizers in DC settings. With the popular Modelica Buildings library expanding its capabilities to district scale, this study is one of the first to demonstrate how the open-source models can be used for detailed energy and control analysis of a DC plant. For a real-world case study, we developed and calibrated high-fidelity models for a DC system central plant at a college campus in Colorado, USA, and we optimized the condenser water supply temperature (CWST) setpoint for a DC plant across multiple time horizons using the Optimization library in Dymola. Results indicate that annual CWST optimization saves 4.7% annual plant energy, with less than 1% of additional energy savings gained through daily optimization. This confirms previous studies' findings that high frequency CWST optimizations are not necessary for the studied system.

chiller plant↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma: Preprint

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2022 Combined Heat and Power/District Energy System Portfolio Meeting (Summary Report)

The U.S. Department of Energy’s (DOE’s) Advanced Manufacturing Office held the 2022 Combined Heat and Power & District Energy System Portfolio Meeting on June 7–9, 2022. The meeting brought together approximately 50 researchers from industry, national laboratories, and research institutes. The purpose of the meeting was for DOE to understand the performance of the projects being sponsored through the CHP program and the status of the technology development, which informs future program planning. This report summarizes the presentations that took place at this event.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilizing GEOPHIRES-X Beyond Electricity

The GEOPHIRES tool is a techno-economic simulator for evaluating the thermal performance and cost-competitiveness of geothermal plants for electricity, heating, and/or cooling. The tool combines reservoir, wellbore, and surface plant cost and performance models to estimate overall techno-economic metrics such as net present value or levelized cost of electricity, heating, or cooling. We recently upgraded the tool to an object-oriented Python framework, presented in an accompanying paper. As part of the upgrade, we enhanced the capability to simulate the performance of geothermal plants for heating and cooling, which is the topic of this paper. Specifically, we (1) integrated absorption chillers to investigate the performance of utilizing geothermal heat for cooling, (2) integrated a heat pump module to boost the geothermal temperature and thermal output, (3) integrated a district heating module to estimate heating demand for a district based on local weather data, and simulated heat supply with geothermal energy and peaking boilers, and (4) integrated GEOPHIRES as an engine in the dGeo simulator to perform a geospatial analysis of geothermal district heating feasibility across a large region (e.g., a state or the entire United States) utilizing resource and thermal demand maps. This paper presents background information and case studies for several of these heating and cooling end-use options in GEOPHIRES.

absorption chiller↗

Modeling Thermal Interactions between Buildings in an Urban Context

Thermal interactions through longwave radiation exchange between buildings, especially in a dense urban environment, can strongly influence a building’s energy use and environmental impact. However, these interactions are either neglected or oversimplified in urban building energy modeling. We developed a new feature in EnergyPlus to explicitly consider this term in the surface heat balance calculations and developed an algorithm to batch calculating the surrounding surfaces’ view factors using a ray-tracing technique. We conducted a case study with a district in the Chicago downtown area to evaluate the longwave radiant heat exchange effects between urban buildings. Results show that the impact of the longwave radiant effects on annual energy use ranges from 0.1% to 3.3% increase for cooling and 0.3% to 3.6% decrease for heating, varying among individual buildings. At the district level, the total energy demand increases by 1.39% for cooling and decreases 0.45% for heating. We also observe the longwave radiation can increase the exterior surface temperature by up to 10 °C for certain exterior surfaces. These findings justify a detailed and accurate way to consider the thermal interactions between buildings in an urban context to inform urban planning and design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AI-Driven Frameworks for Characterizing Urban Energy Systems

We develop AI-driven frameworks to characterize urban energy systems with the goal of transforming planning by reducing the labor of model generation, scaling scenario exploration, and improving accuracy for localized analysis. The approach integrates top-down and bottom-up data to train different AI models that predict missing information and generate inputs and targeted scenarios for district-scale models. The result is a scalable framework that provides actionable insights for reliable and efficient planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design, modeling and simulation of nuclear-powered integrated energy systems with cascaded heating applications

Nuclear-renewable integrated energy systems (IES) consist of a variety of energy generation and conversion technologies and can be used to meet heterogeneous end uses (e.g., electricity, heat, and cooling demands). In addition to supply-demand balance, end-use heat demands usually require heat supply of certain temperature ranges. The effective and efficient utilization of heat produced within an IES is, therefore, a critical challenge. Here, this paper examines design options of an IES that includes heating processes of multiple temperature grades. We investigate a cascaded design configuration, where the remaining residual heat after high-grade heating processes [e.g., hydrogen production through high-temperature steam electrolysis (HTSE)] is recovered to meet the low-grade heating needs [e.g., district heating (DH)]. Additionally, a thermal energy storage system is integrated into the DH system to address the imbalance between heat supply and demand. This paper primarily focuses on the design and modeling of the proposed system and evaluates its operation with a 24-h transient process simulation using a DH demand profile with hourly resolution. The results indicate that the residual heat from the HTSE exhaust is insufficient for the DH demand, and additional topping heat directly from the reactor process steam is needed. Furthermore, the inclusion of thermal energy storage within the DH system provides the necessary balance between thermal generation and demand, thereby ensuring a consistent rated temperature of the DH supply water. This approach helps minimize the control actions needed on the reactor side.

08 HYDROGEN↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DC Solar for All: Implementation Plan to Scale Low- and Moderate- Income Community Solar + Storage Resilience Hubs in the District of Columbia

This implementation plan discusses the District of Columbia's strategy to combine low-income community solar projects with resilience technologies. Through the technical and financial support offered by the Inclusive Shared Solar Initiative and building on extensive stakeholder engagement in LMI neighborhoods around the District, the District of Columbia team expects to reduce energy burdens for LMI residents, address barriers to and streamline SfA program enrollment, and support the development of innovative benefit delivery models, including a community solar-supported climate resilience center.

14 SOLAR ENERGY↗

Raising the Bar in High Performance Laboratory Design

Laboratory facilities are expensive to build and operate, they consume energy at high rates compared to other types of buildings, and modifications are frequently required to accommodate ever-changing research activities. PNNL sought ways to address these issues in the design and construction of a 14,700 sq. ft. new laboratory building. To improve adaptability to change a high roof structure was used that allows raising the ceiling when needed with minimal disruption to installed HVAC and electrical utilities. Also, HVAC equipment was located on a mezzanine above the central corridor rather than above ceilings. This eliminates the need for maintenance personnel to routinely access lab spaces, reducing disruption to research staff and improving maintenance access. To improve the reliability of operations while reducing energy consumption, heat pipe heat recovery with evaporative cooling, zoned heating/cooling coils, high-efficiency condensing boilers, district cooling, VAV fume hoods, DDC controls, energy use monitoring, and implementation of the US Department of Energy’s Guiding Principles for Federal Leadership in Sustainable Buildings were all used. The energy model developed during design projected energy use at 2,840 MBtu/yr, a 13.5% savings over ASHRAE Standard 90.1-2010. The first full year of operation resulted in actual energy use of 2,661 MBtu, a savings of 19% over Standard 90.1. As a result of the project design’s demonstrated success, these strategies will be incorporated into a significantly larger (125,000 sq ft), $65 million lab facility to be constructed on the PNNL campus in 2020.

Scott, Jeffery M.↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Designing for Zero Energy and Zero Carbon on a Multi-Building Scale Using URBANopt: Preprint

Groundbreaking efforts are necessary to mitigate contributors increasing impacts of climate change. In parallel to inventing pioneering clean energy technologies it is even more fundamental to rethink designing energy systems within a singular facility and collectively to function as a district. Facilities should not be continuously passive by just consuming; there is a need to shift to perform more dynamically. Designing for zero energy and zero carbon on a multi-building scale can uncover opportunities for building energy efficiency, decarbonization, demand flexibility, and resiliency that are not accessible at an individual building scale. This approach can be challenging without innovative tools to evaluate the multitude of possibilities. As an investigated result, we highlight the use of a campus-scale energy modeling platform - URBANopt™ - for the expansion of the National Renewable Energy Laboratory's (NREL's) South Table Mountain campus in Golden, Colorado. Programmatic growth included the design of three new all-electric, zero-energy, and zero-carbon, mixed used buildings (a combination of research laboratories and office space). This investigation is critical to NREL reaching net-zero emissions for its operational footprint, which will occur in phases over the next decade. Leveraging URBANopt's capabilities, we evaluate 1) high-performance building energy efficiency and decarbonization measures, 2) 4th generation district heating and cooling (4th GDHC) systems, 3) optimized onsite generation and energy storage assets that meet zero-energy and zero-carbon targets at minimum life-cycle costs, and 4) cost-optimal distributed energy technology mixes, dispatch strategies, and associated capacities that increase resiliency to grid outages. This work demonstrates the use and capabilities of URBANopt through a real-world case study on a multi-building scale.

community energy model↗

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY↗