Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Q-Learning-Based Impact Assessment of Propagating Extreme Weather on Distribution Grids

The increasing number of power outage events due to extreme weather conditions is hampering us socioeconomically. Preparing in advance for the extreme weather event is critical. It can help utility operators to reduce grid damages, restore grid service quickly, allocate energy resources and repair crews strategically, and hence dramatically increase grid resilience. In this paper, we propose a method to identify the sequence of worst impact zones in the power grid caused by extreme weather events based on Q-learning (a reinforcement learning algorithm). To quantity the weather severity and its effect on the grid, we model the impact of extreme weather on the grid as a function of intensity, vulnerability, and exposure. A modified IEEE 123-node distribution feeder is presented in a mesh grid and experimented for sequences of zones identification. Finally, simulation results present the identified sequences and their associated impacts on the grid caused by extreme weather events.

distribution system↗

Q-Learning Based Impact Assessment of Propagating Extreme Weather on Distribution Grids: Preprint

Increasing number of power outage events due to extreme weather condition is hampering us socioeconomically. Preparing in advance for the extreme weather event is critical and can help utility operators to reduce grid damages, restore grid service quickly, allocate energy resources and repair crews strategically, and hence dramatically increase grid resilience. In this paper, we propose a method to identify the sequence of worst impact zones in the power grid caused by extreme weather events based on Q-learning (a reinforcement learning algorithm). To quantify weather severity and it’s effect on the grid, we model the impact of extreme weather on the grid as a function of intensity, vulnerability and exposure. A modified IEEE 123-node distribution feeder is presented in a mesh grid and experimented for sequences of zones identification. Finally, simulation results present the identified sequences and their associated impacts on the grid caused by the extreme weather events.

distribution system↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interconnection Standards for Combined Heat and Power (CHP) - State Standards that Impact Interconnection to the Electric Distribution Grid

This Issue Brief examines state interconnection policies that apply to CHP throughout the United States. It discusses barriers to CHP interconnection and describes elements of effective interconnection standards. The information in this document is intended to help inform state regulators, policy makers, utility personnel, electricity customers, and other stakeholders about the current status of CHP interconnection requirements, and how the interconnection process could be improved to accelerate the adoption of CHP.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing impact of $\mathrm{DER}$ on $\mathrm{FIDVR}$ - comparison of $\mathrm{EMT}$ simulation of a combined transmission and distribution grid with aggregated positive sequence models

The increase in percentage of distributed energy resources (DERs) brings in a degree of uncertainty in bulk power system planning and operations. Further, the presence of 1 - φ induction motors introduces the possibility of motor stalling and fault induced delayed voltage recovery (FIDVR). With newer versions of IEEE Std 1547™ there can be the opportunity to obtain dynamic voltage support from DERs. In this report, the impact of DERs providing dynamic voltage on the dynamic behavior of 1 - φ induction motors is examined in detail along with an exploration of the need for simulation platforms that go beyond positive sequence. The studies discussed here are carried out both in detailed electromagnetic time domain and in positive sequence domain for comparison.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Least-cost Optimal Distribution Grid Expansion (LODGE) v1

LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate new loads and behind-the-meter DERs in combination with advanced non-wire alternative (NWA) planning solutions, such as utility-owned storage and distributed PV. Working with a set of least-cost solutions per feeder/substation allows us to benchmark and compare techno-economic performance of different traditional and NWA planning solutions. An important aspect of the LODGE model is that it includes power flow operation constraints. This means that the least-cost planning solutions delivered by LODGE are technically feasible. Available projects in LODGE portfolio include: 1) feeder reconductoring; 2) transformers upgrades; 3) non-wire alternatives, such as strategic siting and sizing of storage and distributed PV; 4) voltage regulators.

Heleno, Miguel↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local and utility-wide cost allocations for a more equitable wildfire-resilient distribution grid

Climate-induced extreme weather conditions make electricity infrastructure more vulnerable. They increase the risk of power-line-ignited wildfires which can, in turn, jeopardize electric power delivery. Here, leveraging machine learning, we show that lower-income communities in California not only have lower fractions of power distribution lines undergrounded, but overhead lines and poles in their neighbourhoods are also more vulnerable to wildfires. Should they bear the cost of undergrounding fire-prone lines themselves, they would have to pay a disproportionately higher cost per household. We propose a cost allocation scheme with an income threshold below which the cost is borne by utility-wide ratepayers and above which the cost is borne locally. This scheme can not only minimize the average of undergrounding costs per household as a share of income, but also homogenize such cost–income ratios across communities. Furthermore, our research demonstrates the opportunity to appropriately integrate existing policies to make electricity infrastructure affordable, equitable and reliable amidst climate change.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Spoofing Detection for Grid Distributed Synchrophasor Using Dynamic dual-Kernel SVM

Cyber spoofing with distributed synchrophasor adversely affects the decision-making and situational awareness of the power grid. To detect the spoofing trail, this letter proposes a composite signature-based cyber spoofing detection methodology. The intrinsic principal modes are first extracted from the distributed synchrophasor data. Then, multiple signatures of different intrinsic model components are derived to quantify the spoofing. Thereafter, the dynamic dual-kernel support vector machine is proposed to identify cyber spoofing using multiple signatures. Multiple experimental results using six spoofing methods have verified the validity of the methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Controllers for Distributed Grid Support for Power Systems using Hybrid DER plants with Electrolyzers [SWR-20-06]

This software presents the design and control for a hybrid DER site with integrated dispatchable electrolyzers. It is a comprehensive solution for regulating the dispatch of electrolyzer demand to support the grid using the respective control functions. Multiple control functions (ramp control, frequency support control, dispatch prioritization) are developed to integrate the proposed site for multiple services around load, voltage and frequency control. This allows the site owners to participate in both distribution and bulk system energy markets for grid ancillary services.

Jain, Rishabh↗

A Managed Tokens Service for Securely Keeping and Distributing Grid Tokens

Fermilab is transitioning authentication and authorization for grid operations to using bearer tokens based on the WLCG Common JWT (JSON Web Token) Profile. One of the functionalities that Fermilab experimenters rely on is the ability to automate batch job submission, which in turn depends on the ability to securely refresh and distribute the necessary credentials to experiment job submit points. Thus, with the transition to using tokens for grid operations, we needed to create a service that would obtain, refresh, and distribute tokens for experimenters’ use. This service would avoid the need for experimenters to be experts in obtaining their own tokens and would better protect the most sensitive long-lived credentials. Further, the service needed to be widely scalable, as we are currently keeping credentials active for approximately 15 experiments, each with 1-3 different credentials, and distributing those credentials to 2-20 submit points per experiment, with those numbers steadily increasing. To address these issues, we created and deployed a Managed Tokens service. The service is written in Go, taking advantage of that language’s native concurrency primitives to easily be able to scale operations as we onboard experiments. The service uses as its first credentials a set of kerberos keytabs, stored on the same secure machine that the Managed Tokens service runs on. These kerberos credentials allow the service to use htgettoken via condor_vault_storer to store vault tokens in the HTCondor credential managers (credds) that run on the batch system scheduler machines (HTCondor schedds); as well as downloading a local, shorter-lived copy of the vault token. The kerberos credentials are then also used to distribute copies of the locally-stored vault tokens to experiment submit points. When experimenters schedule jobs to be submitted, these distributed vault tokens are used to access a Hashicorp Vault instance (run separately from the Managed Tokens service), and previously-stored refresh tokens there are used to obtain the bearer token that is submitted with the job. We will discuss here the design of the Managed Tokens service, including elaborating on certain choices we made with regards to concurrent operations, configuration, monitoring, and deployment.

Bhat, Shreyas↗

A Managed Tokens Service for Securely Keeping and Distributing Grid Tokens

Fermilab is transitioning authentication and authorization for grid operations to using bearer tokens based on the WLCG Common JWT (JSON Web Token) Profile. One of the functionalities that Fermilab experimenters rely on is the ability to automate batch job submission, which in turn depends on the ability to securely refresh and distribute the necessary credentials to experiment job submit points. Thus, with the transition to using tokens for grid operations, we needed to create a service that would obtain, refresh, and distribute tokens for experimenters' use. This service would avoid the need for experimenters to be experts in obtaining their own tokens and would better protect the most sensitive long-lived credentials. Further, the service needed to be widely scalable, as Fermilab hosts many experiments, each of which would need their own credentials. To address these issues, we created and deployed a Managed Tokens Service. The service is written in Go, taking advantage of that language's native concurrency primitives to easily be able to scale operations as we onboard experiments. The service uses as its first credentials a set of kerberos keytabs, stored on the same secure machine that the Managed Tokens service runs on. These kerberos credentials allow the service to use htgettoken via condor_vault_storer to store vault tokens in the HTCondor credential managers (credds) that run on the batch system scheduler machines (HTCondor schedds); as well as downloading a local, shorter-lived copy of the vault token. The kerberos credentials are then also used to distribute copies of the locally-stored vault tokens to experiment submit points.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the method of lines for solution of the Navier-Stokes equations using nonuniform grid distributions

The method of lines is investigated for the numerical solution of the stream function and velocity form of the Navier-Stokes equations on nonuniform grids. Stiffness characteristics of a linear one-dimensional model equation are examined to establish the feasibility of applying the method to the volicity equation in two dimensions. It is observed that the transformed governing equations in computational domain become stiffer with increasing the number of grid points and the differencing technique affects the stiffness characteristics. The results demonstrate that the method of lines under certain circumstances is highly suitable for the numerical solution of physical problems on domains covered with variable grids.

Tiwari, S. N.↗

Spatio-temporal impacts of a utility’s efficiency portfolio on the distribution grid

Energy Efficiency has historically focused on delivering savings to offset growth in energy supply. Today’s growing emphasis on decarbonization of the energy supply is driving renewables adoption and increased interest in electrification. As a result, energy efficiency is being assessed not just in its ability to offset load growth, but also for its ability to alleviate location-specific constraints on transmission and distribution infrastructure. This work demonstrates that advanced measurement and verification modeling techniques can be used to estimate the spatio-temporal grid impact of a portfolio of energy efficiency programs. It extends measurement-based methods to an entire Demand Side Management portfolio and uses a single model to predict annual as well as seasonal building energy use with near-zero bias. In addition, new metrics are introduced to assess grid level impacts of energy efficiency. The results show that the efficiency program portfolio delivers savings of over 12% at the territory-wide proxy level, with substation and feeder level savings ranging from 0.4% to 26%, and ~5%-42% respectively. Overall, these savings impacted 1.0%–1.4% of the energy used at these locations in the grid. This work provides a methodology with potential to connect efficiency with distribution planning, carrying implications for non-wires alternatives and targeted delivery of efficiency programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Grid Control of Flexible Loads and DERs for Optimized Provision of Synthetic Regulating Reserves

Over the course of this project, we have successfully de-risked our distributed microgrid control architecture by tightly integrating its associated control algorithms into a unified software library, installing the software library on several industrial-grade target hardware platforms, and validating the performance of the resulting microgrid controller in a real-life microgrid. Upon completion of the project, we demonstrated that our distributed control architecture is resilient against (i) failures in control devices, (ii) unreliable communication links, (iii) delays in transmitted data, and (iv) imperfect knowledge of the number of (and state of) generation and load assets in the microgrid. In this final report, we present results from all the milestones that were accomplished over the course of this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗