Comparison of Organ Dosimetry for Astronaut Phantoms: Earth-Based vs. Microgravity-Based Anthropometry and Body Positioning

The purpose of this study is to use NASA radiation transport codes to compare astronaut organ dose equivalents resulting from solar particle events (SPE), geomagnetically trapped protons, and free-space galactic cosmic rays (GCR) using phantom models representing Earth-based and microgravity-based anthropometry and positioning. Methods: The Univer sity of Florida hybrid adult phantoms were scaled to represent male and female astronauts with 5th, 50th, and 95th percentile heights and weights as measured on Earth. Another set of scaled phantoms, incorporating microgravity-induced changes, such as spinal lengthening, leg volume loss, and the assumption of the neutral body position, was also created. A ray-tracer was created and used to generate body self-shielding distributions for dose points within a voxelized phantom under isotropic irradiation conditions, which closely approximates the free-space radiation environment. Simplified external shielding consisting of an aluminum spherical shell was used to consider the influence of a spacesuit or shielding of a hull. These distributions were combined with depth dose distributions generated from the NASA radiation transport codes BRYNTRN (SPE and trapped protons) and HZETRN (GCR) to yield dose equivalent. Many points were sampled per organ. Results: The organ dos e equivalent rates were on the order of 1.5-2.5 mSv per day for GCR (1977 solar minimum) and 0.4-0.8 mSv per day for trapped proton irradiation with shielding of 2 g cm-2 aluminum equivalent. The organ dose equivalents for SPE irradiation varied considerably, with the skin and eye lens having the highest organ dose equivalents and deep-seated organs, such as the bladder, liver, and stomach having the lowest. Conclus ions: The greatest differences between the Earth-based and microgravity-based phantoms are observed for smaller ray thicknesses, since the most drastic changes involved limb repositioning and not overall phantom size. Improved self-shielding models reduce the overall uncertainty in organ dosimetry for mission-risk projections and assessments for astronauts

VanBaalen, Mary↗

A two-stage service restoration method for electric power distribution systems

Improving the reliability of power distribution systems is critically important for both utilities and customers. This calls for an efficient service restoration module within a distribution management system to support the implementation of self-healing smart grid networks. Although the emerging smart grid technologies, including distributed generators (DGs) and remote-controlled switches, enhance the self-healing capability and allow faster recovery, they still pose additional complexity to the service restoration problem, especially under cold load pickup (CLPU) conditions. Herein, a novel two-stage restoration framework is proposed to generate a restoration solutions with a sequence of control actions. The first stage generates a restoration plan that supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islanding methods. The second stage generates an optimal sequence of switching operations to bring the outaged system quickly to the final restored configuration. The problem is formulated as a mixed-integer linear program that incorporates system connectivity, operating constraints, and the CLPU models. It is demonstrated that on using a multi-feeder test case, the proposed framework is effective in utilizing all available resources to quickly restore the service and generate an optimal sequence of switching actions to be used by the operator to reach the desired optimal configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

USAID Colombia Young Leaders Workforce Training Program Action Plans: Forecasting Distributed Photovoltaic Adoption in Barranquilla, Colombia

As part of the U.S. Agency for International Development (USAID)-National Renewable Energy Laboratory (NREL) Young Leaders Workforce Training Program in Colombia, the Association of Renewable Energies Colombia (SER) participants leveraged their training and professional experience to develop an action plan for modeling the projected adoption of distributed solar photovoltaics (PV) out to 2050 for the city of Barranquilla, Colombia. This case study provides an overview of the key activities and outcomes of the Distributed Generation Market Demand Model (dGen™) Colombia project.

14 SOLAR ENERGY↗

Generation of Kappa Distributions in Solar Wind at 1 au

We examine the generation of kappa distributions in the solar wind plasma near 1 au. Several mechanisms are mentioned in the literature, each characterized by a specific relationship between the solar wind plasma features, the interplanetary magnetic field (IMF), and the kappa index-the parameter that governs the kappa distributions. This relationship serves as a signature condition that helps the identification of the mechanism in the plasma. In general, a mechanism that generates kappa distributions involves a single or a series of stochastic or physical processes that induces local correlations among particles. We identify three fundamental solar wind plasma conditions that can generate kappa distributions, noted as (i) Debye shielding, (ii) frozen IMF, and (iii) temperature fluctuations, each one prevailing in different scales of solar wind plasma and magnetic field properties. Moreover, our findings show that the kappa distributions, and thus, their generating mechanisms, vary significantly with solar wind features: (i) the kappa index has different dependence on the solar wind speed for slow and fast modes, i.e., slow wind is characterized by a quasi-constant kappa index, K (is) approx. 4.3 +/- 0.7, while fast wind exhibits kappa indices that increase with bulk speed; (ii) the dispersion of magnetosonic waves is more effective for lower kappa indices (i.e., further from thermal equilibrium); and (iii) the kappa and polytropic indices are positively correlated, as it was anticipated by the theory.

Livadiotis, G.↗

FERC Order No. 2222 and Considerations for Distributed Wind

The Federal Energy Regulatory Commission (FERC) issued Order No. 2222 in October 2020. The rule directs Regional Transmission Organizations and Independent System Operators (ISOs) to amend their tariffs and participation models to accommodate heterogeneous distributed energy resource (DER) aggregations in the wholesale energy markets that they operate, including capacity, energy, and ancillary service markets. The Commission issued the rule to better capture the benefits provided by DERs deployed in the United States, whose use has been expanding rapidly. The Commission defines DERs as “any resource located on the distribution system, any subsystem thereof or behind a customer meter,” including but not limited to “electric storage resources, distributed generation, demand response, energy efficiency, thermal storage, and electric vehicles and their supply equipment.” The rule aims to increase DER participation in wholesale markets by allowing the creation of DER aggregations, in which multiple DERs that are too small to meet minimum capacity requirements for wholesale markets individually would be able to participate in markets as a single unit. As of June 20, 2023, all ISOs have filed initial compliance plans and a number have begun implementation. Compliance dates range from 2024 to 2029, with Midcontinent ISO having the latest date of compliance proposed for 2029. Southwest Power Pool still has an outstanding date, having no final order yet from FERC, but a target date of the third quarter of calendar year 2025. The rule, which is technology agnostic and requires ISOs to create participation plans that accommodate different DERs, provides an opportunity for distributed wind market expansion. In addition, distributed wind can bring benefits to heterogenous DER aggregations. These benefits include resource diversity (i.e., a complementary generation profile to other types of distributed generation), its small footprint and ability to be co-located with load, and its potential to provide frequency response, voltage support, and black start services, among other ancillary services. This report provides a status update on FERC Order No. 2222, the current state of ISO compliance, and information relevant to the distributed wind industry as DER aggregators and other stakeholders expand their participation to wholesale energy markets.

17 WIND ENERGY↗

LA100 Equity Strategies. Chapter 8: Equitable Rooftop Solar Access and Benefits

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on analysis of customer-sited rooftop solar and storage as a means to reduce electricity bills for low- and moderate-income (LMI) households, multifamily building residents, and renters, who traditionally lack access to bill savings from rooftop solar. Specifically, NREL modeled customer-sited solar and storage adoption using the Distributed Generation Market Demand (dGen™)1 model through 2035 and developed scenarios to identify programs or policies that could support equitable access to bill savings from rooftop solar or solar-plus-storage. Scenarios tested include a direct-install program for LMI customers, net metering for LMI customers, and equitable distribution of benefits from installing solar between owners and renters of renter-occupied buildings. Research was guided by input from the community engagement process, and equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Resilience Analytics for Interdependent Power and Water Distribution Systems

The occurrence of large-scale outages in power distribution systems (PDSs) caused, for instance, by extreme weather events has raised concerns on the cascading impact of the power outages on the resilience of other critical infrastructures, including water distribution systems (WDSs), whose healthy operation highly relies on the availability of power from PDSs. Here, this paper proposes an analytics model for quantifying the interdependence between the resilience of power and water distribution systems. The proposed model first performs spatio-temporal outage analysis on the PDS and WDS to determine the PDS power serving capability and the resulting cascading impact on the WDS water serving capability during the occurrence of disruptions. The resilience interdependence is then determined by a proposed set of six metrics calculated using the power and water serving capability profiles, which trace and quantify the cascading impacts of power outages in the operation of WDSs during the degradation and recovery stages. The proposed analytics model is implemented on the IEEE 33-bus power distribution system supplying power for pumping stations of a 15-node test WDS, considering multiple cases of water storage capacity, single and multiple outage scenarios, and availability of distributed generation. The numerical results demonstrate that the proposed metrics track the temporal and spatial interdependence between the resilience of power and water distribution systems, providing a mechanism to identify weak spots, and assess options to enhance the resilience of the critical water infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Forecasting Distributed PV Adoption in Barranquilla, Colombia [Slides]

The objective of the dGen Colombia project is to provide projections to 2050 on distributed PV deployment by sector for a range of scenarios for Barranquilla, Colombia. NREL used the open-source Distributed Generation Market Demand Model (dGen) adapted for international projects for this analysis. As part of this analysis, technical potential, economic potential, and adoption projections of rooftop and groundmount PV for the city of Barranquilla are presented. Five main scenarios and their combinations were modeled to provide insight on the impact of increased demand from electric vehicles, air conditioning, and time-of-use tariffs.

14 SOLAR ENERGY↗

Community Solar and Community Solar+Storage: A Roadmap of Barriers and Solutions for Commercial Systems in NYC

Sustainable CUNY worked with decision makers and subject matter experts (SME's) to identify the barriers to and solutions for advancing commercial Community Solar (CS) and CS+Storage (CS+S) in urban areas. This roadmap captures the key challenges and solutions identified by New York City (NYC) stakeholders, including the Real Estate Board of New York (REBNY), through a collaborative process. Solar, as well as storage, are among the fastest growing energy segments in the United States, with CS, also known as Community Distributed Generation (CDG), gaining popularity with those who may not own or have access to a viable roof. Urban areas like NYC, which have a large population of renters, are particularly well suited for CS projects where credits from the power produced by a large remote installation are offered on a subscription basis to residents or businesses in the community. However, CS and CS+S projects have stalled at the doorstep of many cities. Host site owners, particularly those with large rooftops, have been slow to commit to installing CS due to competing rooftop usage and programs, limited knowledge about incentives, lack of economic data, and a complicated implementation process.

14 SOLAR ENERGY↗

Analysis of Conservation Voltage Reduction under Inverter-Based VAR-Support [Slides]

Conservation voltage reduction (CVR) is a common technique used by utilities to strategically reduce demand during peak periods. As penetration levels of distributed generation (DG) continue to rise and advanced inverter capabilities become more common, it is unclear how the effectiveness of CVR will be impacted and how CVR interacts with advanced inverter functions. In this work, we investigated the mutual impacts of CVR and DG from photovoltaic (PV) systems (with and without autonomous Volt-VAR enabled). The analysis was conducted on an actual utility dataset, including a feeder model, measurement data from smart meters and intelligent reclosers, and metadata for more than 30 CVR events triggered by the utility over the year. The installed capacity of the modeled PV systems represented 66% of peak load, but reached instantaneous penetrations reached up to 2.5x the load consumption over the year. While the objectives of CVR and autonomous Volt-VAR are opposed to one another, this study found that their interactions were mostly inconsequential since the CVR events occurred when total PV output was low.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System Modeling and Robust Stability Region Analysis for Multi-inverters Based on VSG

As the number of inverter-interfaced distributed generators (IIDGs) increases, the decrease in the inertia of the microgrid affects the stability of microgrid voltage and current. The virtual synchronous generator (VSG) control method simulates the output characteristics of the synchronous machine to improve the inertia and damping of the microgrid. However, low-frequency oscillations can occur in systems with multi-VSGs connected in parallel, primarily when operating in island mode. Therefore, this article develops the small-signal state-space model for multi-inverters based on VSG and analyses the robust stability region (RSR) of the control parameters. Firstly, an extensible small-signal state-space model is established and simplified in the dq axis, which is a necessary preprocessing for the subsequent stability analysis. Secondly, the guardian map method based on bialternate product operation is constructed, and the RSR is established through translation mapping and rotation mapping. Therefore, the solution of RSR is transformed into the problem of identifying the Hurwitz matrix. Finally, the simulations and experiments verify that the calculated region can ensure stable operation during startup and meet the requirement to suppress low-frequency oscillations. In conclusion, the method of solving RSR proposed in this paper provides a basis for selecting controller parameters in practical engineering.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PowerNet: Multi-agent Deep Reinforcement Learning for Scalable Powergrid Control

This paper develops an efficient multi-agent deep reinforcement learning algorithm for cooperative controls in powergrids. Specifically, we consider the decentralized inverter-based secondary voltage control problem in distributed generators (DGs), which is first formulated as a cooperative multi-agent reinforcement learning (MARL) problem. We then propose a novel on-policy MARL algorithm, PowerNet, in which each agent (DG) learns a control policy based on (sub-)global reward but local states and encoded communication messages from its neighbors. Motivated by the fact that a local control from one agent has limited impact on agents distant from it, we exploit a novel spatial discount factor to reduce the effect from remote agents, to expedite the training process and improve scalability. Furthermore, a differentiable, learning-based communication protocol is employed to foster the collaborations among neighboring agents. In addition, to mitigate the effects of system uncertainty and random noise introduced during on-policy learning, we utilize an action smoothing factor to stabilize the policy execution. To facilitate training and evaluation, we develop PGSim, an efficient, high-fidelity powergrid simulation platform. Here, experimental results in two microgrid setups show that the developed PowerNet outperforms the conventional model-based control method, as well as several state-of-the-art MARL algorithms. The decentralized learning scheme and high sample efficiency also make it viable to large-scale power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chapter 32 - Power Grid Resilience

The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.

anomaly detection↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.

Giraldo, Jairo↗

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy↗

SCRES Energy Quest Workshop (Technical Report)

Energy Quest: Sitka’s Path to 2050 is a game based public engagement tool developed as part of the Sitka Community Renewable Energy Strategy and the U.S. Department of Energy’s Energy Transitions Initiative Partnership Project Cohort 3. Designed for Sitka’s isolated island microgrid, which is powered primarily by hydropower and depends on imported diesel for backup, the game translated complex long term energy planning questions into an interactive format. In facilitated workshops, residents built energy roadmaps to 2050, explored tradeoffs, and expressed priorities around four themes: affordability, reliability, self sufficiency, and innovation. Across sessions, participants showed strong support for increasing local self sufficiency and resilience, even when this required balancing near term affordability with long term investments. They emphasized reducing dependence on imported diesel, making better use of existing hydropower, and considering new renewable generation such as solar, wind, and additional hydropower. Survey and game responses also highlighted interest in using surplus hydropower to support new industries, expanding electrification of heating and transportation, and exploring emerging technologies and green fuels. The report organizes these findings into four scenario themes to guide Sitka’s 2050 energy planning. Affordability focuses on managing rate impacts, efficiency, and conservation. Reliability addresses diversified generation, backup power, and energy security. Self sufficiency emphasizes distributed generation and reduced reliance on imported fuels. Innovation explores new technologies, marine based energy solutions, and low carbon fuels. By grounding future planning in these community derived themes, Energy Quest shows how a game based approach can make technical energy planning more accessible and inclusive for remote communities. For questions about the game board and piece production email Dr. Sarah Troise (sarah.troise@pnnl.gov)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Per-Phase and 3-Phase Optimal Coordination of Directional Overcurrent Relays Using Genetic Algorithm

Penetration of the power grid by renewable energy sources, distributed storage, and distributed generators is becoming increasingly common. Increased utilization of these distributed energy resources (DERs) has given rise to additional protection coordination concerns, particularly where they are utilized in an unbalanced manner or where loading among phases is unbalanced. Digital relays such as the SEL-751 (produced by Schweitzer Engineering Laboratories, Pullman, WA, USA) series have the capability of being set on a per-phase basis. This capability is underutilized in common practice. Additionally, in optimization algorithms for determining relay settings, the time-overcurrent characteristics (TOCs) of relays are generally not treated as variables and are assigned before running the optimization algorithm. In this paper, TOC options themselves are treated as discrete variables to be considered in the optimization algorithm. A mixed integer nonlinear programming problem (MINLP) is set up where the goal is to minimize relay operating times. A genetic algorithm (GA) approach is implemented in MATLAB where two cases are considered. In the first case, the TOC and Time dial setting (TDS) of each relay is set on a three-phase basis. In the second case, per-phase settings are considered. Relay TDSs and TOCs are both considered as simultaneous discrete control variables. Despite the stochastic nature of using per-phase settings for unbalanced systems is found to generally allow for shorter operating times. However, for relatively balanced systems, it is best to use three-phase settings if computation time is of importance.