Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Lightweight Magnetic Cooler With a Reversible Circulator

A design of a highly efficient and lightweight space magnetic cooler has been developed that can continuously provide remote/distributed cooling at temperatures in the range of 2 K with a heat sink at about 15 K. The innovative design uses a cryogenic circulator that enables the cooler to operate at a high cycle frequency to achieve a large cooling capacity. The ability to provide remote/distributed cooling not only allows flexible integration with a payload and spacecraft, but also reduces the mass of the magnetic shields needed. The active magnetic regenerative refrigerator (AMRR) system is shown in the figure. This design mainly consists of two identical magnetic regenerators surrounded by their superconducting magnets and a reversible circulator. Each regenerator also has a heat exchanger at its warm end to reject the magnetization heat to the heat sink, and the two regenerators share a cold-end heat exchanger to absorb heat from a cooling target. The circulator controls the flow direction, which cycles in concert with the magnetic fields, to facilitate heat transfer. Helium enters the hot end of the demagnetized column, is cooled by the refrigerant, and passes into the cold-end heat exchanger to absorb heat. The helium then enters the cold end of the magnetized column, absorbing heat from the refrigerant, and enters the hot-end heat exchanger to reject the magnetization heat. The efficient heat transfer in the AMRR allows the system to operate at a relatively short cycle period to achieve a large cooling power. The key mechanical components in the magnetic cooler are the reversible circulator and the magnetic regenerators. The circulator uses non-contacting, self-acting gas bearings and clearance seals to achieve long life and vibration- free operation. There are no valves or mechanical wear in this circulator, so the reliability is predicted to be very high. The magnetic regenerator employs a structured bed configuration. The core consists of a stack of thin GGG disks alternating with thin polymer insulating films. The structured bed reduces flow resistance in the regenerator and therefore the pumping work by the cryogenic circulator. This magnetic cooler will enable cryogenic detectors for sensing infrared, x-ray, gamma-ray, and submillimeter radiation in future science satellites, as well as the detector systems in the Constellation-X (Con-X) and the Single Aperture Far-Infrared observatory (SAFIR). Scientific ap p - lica tions for this innovation include cooling for x-ray micro calorimeter spectrometers used for microanalysis, cryogenic particle detectors, and superconducting tunnel junction de tectors for biomolecule mass spectrometry. The cooler can be scaled to provide very large cooling capacities at very low temperatures, ideal for liquid helium and liquid hydrogen productions.

Chen, Weibo↗

Heat flow experiment

The heat flow experiment conducted during the Apollo 17 flight in the Taurus-Littrow area of the moon is discussed. The concept of the experiment is based on the direct measurement of the vertical flow of heat through the regolith. The measurement is made far enough below the surface so that the time-varying heat flow resulting from the very large diurnal variations of the surface temperature is small as compared with the flow from the interior. The equipment used for the experiment is described and illustrated. Graphs are developed to present the results of heat flow and surface temperature measurements.

Langseth, M. G., Jr.↗

Giant Thermoelectric Power Factor Anisotropy in PtSb 1.4 Sn 0.6

In this work, we report on the giant anisotropy found in the thermoelectric power factor (S 2 σ) of marcasite structure-type PtSb 1.4 Sn 0.6 single crystal. PtSb 1.4 Sn 0.6 , synthesized using an ambient pressure flux growth method upon mixing Sb and Sn on the same atomic site, is a new phase different from both PtSb 2 and PtSn 2 , which crystallize in the cubic Pa$\bar{3}$ pyrite and Fm$\bar{3}$m fluorite unit cell symmetry, respectively. The large difference in S 2 σ for heat flow applied along different principal directions of the orthorhombic unit cell stems mostly from anisotropic Seebeck coefficients.

36 MATERIALS SCIENCE↗

Energy distribution in parallel plate plasma accelerators

A parallel plate accelerator operated in the quasi-steady regime of argon mass flow discharges permits, on account of its geometry, the appraisal of the initial ratio of energy disposition into the kinetic and thermal modes of the plasma while retaining the essential features of coaxial high power self-field MPD accelerators. The energy disposition ratio, calculated as the ratio of kinetic energy to enthalpy in the exhaust flow, shows reasonable agreement with the ratio of the induced emf in the accelerator to resistive voltage drop. Both these ratios indicate that the discharge imparts more energy to the flow by resistive heating than by direct body force acceleration. This is turn suggests that other acceleration mechanisms must be responsible for the high performance of conventional MPD arcs.

Dicapua, M. S.↗

A hot-wire method for high-intensity turbulent flows

A measuring technique for determing instantaneous, three-dimensional velocity vectors in highly turbulent flows by means of a 4-sensor hot-wire probe is described. As is well known, the hot-wire signal received in reversing flows cannot uniquely be interpreted. This difficulty is circumvented by tracking the thermal wake of a heated wire. Whenever the approximate flow direction is indicated by a temperature-sensitive wake detector, all components of the instantaneous velocity vector are evaluated by means of a digital data reduction method. Uniqueness of the solution derived from the triple-hot-wire response equations is examined. A first application of the proposed measuring technique in the recirculating flow downstream of a backward-facing step is described.

Mueller, U. R.↗

The materials processing research base of the Materials Processing Center

An annual report of the research activities of the Materials Processing Center of the Massachusetts Institute of Technology is given. Research on dielectrophoresis in the microgravity environment, phase separation kinetics in immiscible liquids, transport properties of droplet clusters in gravity-free fields, probes and monitors for the study of solidification of molten semiconductors, fluid mechanics and mass transfer in melt crystal growth, and heat flow control and segregation in directional solidification are discussed.

Latanision, R. M.↗

Anode power deposition in magnetoplasmadynamic thrusters

Results of anode heat-flux and anode fail measurements from a multimegawatt self-field quasi-steady magnetoplasmadynamic (MPD) thruster are presented. Measurements were obtained with argon and helium propellants for a variety of currents and mass flow rates. Anode heat flux was directly measured with thermocouples attached to the inner surface of a hollowed section. Anode falls were determined both from floating probes and through heat flux measurements. Comparison of data acquired through either method shows excellent agreement. Anode falls varied between 4-50 V with anode power fractions reaching 70 percent with helium at 150 kW, and 50 percent with argon at 1.9 MW. The anode fall was found to correlate well with electron Hall parameters calculated from triple Langmuir and magnetic probe data collected near the anode. Two possible explanations for this result are proposed: (1) the establishment of large electric fields at the anode to maintain current conduction across the strong magnetic fields; and (2) anomalous resistivity resulting from the onset of microturbulence in the plasma. To investigate the latter hypothesis, electric field, magnetic field, and current density profiles measured in the vicinity of the anode were incorporated into Ohm's law to estimate the electrical conductivity. Results of this analysis show a substantial deviation of the measured conductivity from that calculated with classical formulas. These results imply that anomalous effects are present in the plasma near the anode.

Gallimore, A. D.↗

Forced Forward Smoldering Experiments Aboard The Space Shuttle

Smoldering is a basic combustion problem that presents a fire risk because it is initiated at low temperatures and because the reaction can propagate slowly in the material interior and go undetected for long periods of time. It yields a higher conversion of fuel to toxic compounds than does flaming, and may undergo a transition to flaming. To date there have been a few minor incidents of overheated and charred cables and electrical components reported on Space Shuttle flights. With the establishment of the International Space Station, and the planning of a potential manned mission to Mars, there has been an increased interest in the study of smoldering in microgravity. The Microgravity Smoldering Combustion (MSC) experiment is part of a study of the smolder characteristics of porous combustible materials in a spacecraft environment. The aim of the experiment is to provide a better fundamental understanding of the controlling mechanisms of smoldering combustion under normal- and microgravity conditions. This in turn will aid in the prevention and control of smolder originated fires, both on earth and in spacecrafts. The microgravity smoldering experiments have to be conducted in a space-based facility because smoldering is a very slow process and consequently its study in a microgravity environment requires extended periods of time. The microgravity experiments reported here were conducted aboard the Space Shuttle. The most recent tests were conducted during the STS-105 and STS-108 missions. The results of the forward smolder experiments from these flights are reported here. In forward smolder, the reaction front propagates in the same direction as the oxidizer flow. The heat released by the heterogeneous oxidation reaction is transferred ahead of the reaction heating the unreacted fuel. The resulting increase of the virgin fuel temperature leads to the onset of the smolder reaction, and propagates through the fuel. The MSC data are compared with normal gravity data to determine the effect of gravity on smolder.

Fernandez-Pello, A. C.↗

Space shuttle base heating analysis

Work performed in support of radiation and convective base heating predictions in developing the space shuttle thermal environment is described. Topics discussed include plume radiation predictions and the development of prediction methods; convective base heating predictions due to both reversed flow and direct plume impingement; and evaluation testing of a gas temperature probe used in short-duration base heating model tests.

Source record↗

Direct heating surface combustor

The combustor utilizes a non-adiabatic flame to provide low-emission combustion for gas turbines. A fuel-air mixture is directed through a porous wall, the other side of which serves as a combustion surface. A radiant heat sink disposed adjacent to and spaced from the combustion surface controls the combustor flame temperature in order to prevent the formation of oxides of nitrogen. A secondary air flow cools the heat sink. Additionally, up to 100% of secondary air flow is mixed with the combustion products at the direct heating surface combustor to dilute such products thereby reducing exit temperature. However, if less than 100% secondary air is mixed to the combustor, the remainder may be added to the combustion products further downstream.

Beremand, D. G.↗

Thermal coupling apparatus for electroexplosive devices

This paper describes the equipment for nondestructive testing of electroexplosive devices using a thermal coupling technique. The technique utilizes a self-balancing bridge to apply a nominal amount of power to the bridge wire of the device. The bridge wire behaving as a thermal sensor detects heat flow into the device when heat is preferentially directed down the center of the explosive column toward the bridge wire. Thermal equilibrium is upset and the change in power from the self-balancing bridge is measured directly in watts. Faults such as omissions, incorrect materials, contamination, and so on, can be detected by observing the rate of heat flow to the bridge wire. The response is indicative of the thermal resistance and diffusivity of the system. The paper also presents data on electroexplosive devices loaded with inert and explosive materials.

Menichelli, V. J.↗

Heat pipe heat rejection system

A prototype of a battery heat rejection system was developed which uses heat pipes for more efficient heat removal and for temperature control of the cells. The package consists of five thermal mock-ups of 100 amp-hr prismatic cells. Highly conductive spacers fabricated from honeycomb panels into which heat pipes are embedded transport the heat generated by the cells to the edge of the battery. From there it can be either rejected directly to a cold plate or the heat flow can be controlled by means of two variable conductance heat pipes. The thermal resistance between the interior of the cells and the directly attached cold plate was measured to be 0.08 F/Watt for the 5-cell battery. Compared to a conductive aluminum spacer of equal weight the honeycomb/heat pipe spacer has approximately one-fifth of the thermal resistance. In addition, the honeycomb/heat pipe spacer virtually eliminates temperature gradients along the cells.

Kroliczek, E. J.↗

Monocoque shell and tube heat exchanger

A heat exchanger with a monocoque structure transfers heat between a first fluid and a second fluid. The heat exchanger in has a plurality of tubes through which the first fluid may flow in a direction, each of the plurality of tubes has a first mouth end, an N opposing second mouth end and a waist region between the first mouth end and the second mouth end. The heat exchanger also has one or more interconnected fluid channels through which the second fluid may flow, the one or more fluid channels lay generally in a plane, the plurality of tubes and the one or more fluid channels interleave such that heat may be transferred between the plurality of tubes and the one or more fluid channels, and the direction of flow of the first fluid is generally perpendicular to the plane of the one or more fluid channels.

Keolian, Robert M.↗

Space shuttle orbiter reentry flow field and heating analysis

The reentry flow field and thermal environment around the straight wing shuttle orbiter vehicle were determined. Both rarefied and continuum flow fields and associated heating rates on various configurations representative of the orbiter at high angle of attack were calculated. Rarefied flow fields and heating rates were computed by the Monte Carlo direct simulation technique for altitudes above 82.3 km. Continuum inviscid flow fields were calculated by 2-D unsteady and 3-D steady finite difference/artificial viscosity methods and also by a 2-D shock layer analysis technique. Viscous flow fields and heating rates in the continuum regime were computed by a boundary layer integral matrix method for laminar flow and by an aerodynamic surface heating technique for turbulent flow. Shapes considered in the study included flat plates (representing the underside of the orbiter fuselage or the wing MAC), orbiter fuselage cross sections, orbiter wing airfoils, and 3-D orbiter configurations, all at high angle of attack (40 - 60 deg). The theoretical results showed good agreement with measured pressure and heat transfer data.

Rochelle, W. C.↗

Method for Measuring Thermal Conductivity of Small Samples Having Very Low Thermal Conductivity

This paper describes the development of a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air. As with other approaches, care is taken to ensure that the heat flow through the test sample is essentially one-dimensional. However, unlike other approaches, no attempt is made to use heated guards to block the flow of heat from the hot plate to the surroundings. It is argued that since large correction factors must be applied to account for guard imperfections when sample dimensions are small, it may be preferable to simply measure and correct for the heat that flows from the heater disc to directions other than into the sample. Experimental measurements taken in a prototype apparatus, combined with extensive computational modeling of the heat transfer in the apparatus, show that sufficiently accurate measurements can be obtained to allow determination of the thermal conductivity of low thermal conductivity materials. Suggestions are made for further improvements in the method based on results from regression analyses of the generated data.

Miller, Robert A.↗

Analysis and comparison of wall cooling schemes for advanced gas turbine applications

The relative performance of (1) counterflow film cooling, (2) parallel-flow film cooling, (3) convection cooling, (4) adiabatic film cooling, (5) transpiration cooling, and (6) full-coverage film cooling was investigated for heat loading conditions expected in future gas turbine engines. Assumed in the analysis were hot-gas conditions of 2200 K (3500 F) recovery temperature, 5 to 40 atmospheres total pressure, and 0.6 gas Mach number and a cooling air supply temperature of 811 K (1000 F). The first three cooling methods involve film cooling from slots. Counterflow and parallel flow describe the direction of convection cooling air along the inside surface of the wall relative to the main gas flow direction. The importance of utilizing the heat sink available in the coolant for convection cooling prior to film injection is illustrated.

Colladay, R. S.↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.