Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct electron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Light-Matter Interaction in Ultrastable Tunneling Nanogaps

Light emission and detection through tunnel junctions have emerged as a promising platform for studying nanoscale light–matter interactions, including electroluminescence and photoassisted transport. However, controlling these interactions in the tunneling regime has been challenging due to complex underlying mechanisms that remain poorly understood. A major obstacle is the difficulty in forming stable junctions that can function reliably over extended periods. In this study, we fabricate ultrastable tunneling junctions consisting of epitaxial indium–tin-oxide, epitaxial lutetium oxide, and gold. With their stable and consistent tunneling currents, we investigate photon-assisted transport phenomena using simple direct-current detection. Our results demonstrate that optical rectification is the primary contributor to the laser-induced current, alongside thermal effects and hot-electron currents. Furthermore, owing to their epitaxial nature and high breakdown threshold, this ultrastable platform holds promise for future real-world applications, including nanoscale light sources and multifunctional photodetectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of directional muon beams generated at the Berkeley Lab Laser Accelerator

We present the detection of directional muon beams produced using a PW laser facility at the Lawrence Berkeley National Laboratory. The muon source is a multi-GeV electron beam generated in a laser-plasma accelerator interacting with a high- converter target. The GeV photons resulting from the interaction are converted into a high-flux, directional muon beam via pair production. By employing scintillators to capture delayed events, we were able to identify the produced muons and characterize the source. Using theoretical knowledge of the muon production process combined with simulations that are in excellent agreement with the experiments, we demonstrate that laser-plasma accelerators have the capability of generating electron beams with characteristics suitable to produce GeV-scale muons that offer unique advantages with respect to the cosmic background. Laser-plasma-accelerator-based muon sources can therefore enhance muon imaging applications thanks to their compactness, directionality, and high yields, which reduce the exposure time by orders of magnitude compared to cosmic ray muons. Using the eant4-based simulation code we developed to gain insight into the experimental results, we can design future experiments and applications based on LPA-generated muons.

Terzani, Davide↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

Single Entity Electrochemistry in Nanopore Electrode Arrays: Ion Transport Meets Electron Transfer in Confined Geometries

Electrochemical measurements conducted in confined volumes provide a powerful and direct means to address scientific questions at the nexus of nanoscience, biotechnology, and chemical analysis. How are electron transfer and ion transport coupled in confined volumes and how does understanding them require moving beyond macroscopic theories? Also, how do these coupled processes impact electrochemical detection and processing? We address these questions by studying a special type of confined-volume architecture, the nanopore electrode array, or NEA, which is designed to be commensurate in size with physical scaling lengths, such as the Debye length, a concordance that offers performance characteristics not available in larger scale structures. The experiments described here depend critically on carefully constructed nanoscale architectures that can usefully control molecular transport and electrochemical reactivity. We begin by considering the experimental constraints that guide the design and fabrication of zero-dimensional nanopore arrays with multiple embedded electrodes. These zero-dimensional structures are nearly ideal for exploring how permselectivity and unscreened ion migration can be combined to amplify signals and improve selectivity by enabling highly efficient redox cycling. Our studies also highlight the benefits of arrays, in that molecules escaping from a single nanopore are efficiently captured by neighboring pores and returned to the population of active redox species being measured, benefits that arise from coupling ion accumulation and migration. These tools for manipulating redox species are well-positioned to explore single molecule and single particle electron transfer events through spectroelectrochemistry, studies which are enabled by the electrochemical zero-mode waveguide (ZMW), a special hybrid nanophotonic/nanoelectronic architecture in which the lower ring electrode of an NEA nanopore functions both as a working electrode to initiate electron transfer reactions and as the optical cladding layer of a ZMW. Furthermore, while the work described here is largely exploratory and fundamental, we believe that the development of NEAs will enable important applications that emerge directly from the unique coupled transport and electron-transfer capabilities of NEAs, including in situ molecular separation and detection with external stimuli, redox-based electrochemical rectification in individually encapsulated nanopores, and coupled sorters and analyzers for nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve sub-GeV/c 2 Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionisation with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

47 OTHER INSTRUMENTATION↗

Cherenkov and Transition Radiation as Low-Energy Background Sources in SuperCDMS Detectors

The Weakly Interacting Massive Particle (WIMP) has historically been a prime candidate for dark matter due to its elegant compatibility with the Minimally Supersymmetric Standard Model (MSSM). Recent dark matter experiments have ruled out much of the GeV-TeV mass range predicted by the MSSM, however, and the newest generation of direct detection experiments, such as SuperCDMS SNOLAB, have begunto explore sub-GeV dark matter. As experiments push towards lower masses, sensitivity to eV-scale electron recoil events has become increasingly important. A variety of unexplained excesses at energy deposits of 1-100 eV have been found inmany such low-mass experiments, across different detection techniques and at different excess rates. These low-energy events are not thought to be dark matter, and they must be understood and effectively removed to further improve detector energy resolution. This thesis will outline the simulation of one possible source of low-energy excess at SuperCDMS: optical photons produced from charges in uniform motion, specifically from Cherenkov radiation (CR), transition radiation (TR), and the intermediate hybrid transition-Cherenkov radiation (HR). In the latter case, the standard formulae for HR contain divergences at certain angles in transparent media, which are an artifact of their derivation and become problematic to simulate. To rsolve this, we present a novel approach to normalize the divergent HR peaks, which allows HR to transition smoothly between TR and CR in a numerical simulation. We also add TR and CR as a physics process to the SuperCDMS Monte Carlo simulation package SuperSim, based on the Geant4 simulation toolkit. To verify the physics of our addition, we show some test simulations in comparison to theoretical predictions of optical radiation intensity. We also use the simulation to make some preliminary predictions on the contribution of TR and CR to the low energy background, with the expectation that more thorough analyses will be conducted in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternate Methods for Cleaning Zirconium Plate

The United States High Performance Research Reactor Conversion Program identified the need to transition from highly enriched uranium fuel to lowly enriched uranium fuel for high power research and civil reactors. One of the fuel configurations selected for these reactors was a uranium (U) foil alloyed with 10% molybdenum (Mo). The U-10Mo fuel foil was then covered with a zirconium (Zr) interlayer and pressed into an aluminum cladding. Idaho National Laboratory prescribed a need to remove surface oxidation on the Zr prior to bonding it with U-10Mo fuel foil. To determine the best method of oxidation removal, a variety of polishing methods, including hand polishing with a diamond paste or Scotch-Brite™ pads, mechanically wet-polishing with abrasive belts, and chemical etching with hydrofluoric/nitric acid mixtures, were investigated on pre-polished Zircaloy 702 sheets purchased directly from the manufacturer. No change in surface roughness was detected using any of these methods relative to the as-received material. In fact, scanning electron microscopy detected grit from hand polishing with Amplex Grade 30 waste soluble diamond paste and Scotch-Brite™ pads. Visible staining was found, and fluorine detected via X-ray photoelectron spectroscopy on the flash etching samples. These contaminants were not seen on the as-received material. In addition to the need to remove the oxide layer on the Zr prior to co-rolling, there are concerns that the Neolube debonding agent on the co-rolling can may contaminate the Zr surface after co-rolling. The experimental results found that zirconium in contact with Neolube coated steel plates was easily cleaning with ethanol wiping after heat treated and no carbide inclusions remained on the surface. Overall, all cleaning methods tested did not significantly change the surface roughness of the plates or reduce the oxide layer present on the zirconium. Carbon was found on all the samples, before and after cleaning, except for the flash etch samples which detected fluorine instead. The insignificant changes seen in the cleaned plates relative to the as received plates question the need for cleaning prior to rolling. Further investigation in the requirements for cleaning at this step is recommended. Current methods for cleaning the surface after hot rolling with alcohol appear sufficient. After hot rolling, if Neolube does peel off the can and onto the zirconium coated foil surface, a dry abrasive or diamond paste polish is not recommended due to the chance of abrasive being embedded into the surface. However, the ability of an etchant to lift the lubricant off the zirconium surface indicates that a spot etch method could work to clean specific spots where Neolube is present, if the need arises.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A novel silicon photomultiplier readout architecture for low-light applications

In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light applications, allows the use of a relatively high SiPM operating voltage. This maximizes photon detection efficiency and minimizes gain/efficiency voltage-dependence while eliminating direct optical cross-talk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searching for MeV-mass neutrinophilic dark matter with large scale dark matter detectors

The indirect detection of dark matter (DM) through its annihilation products is one of the primary strategies for DM detection. One of the least constrained classes of models is neutrinophilic DM, because the annihilation products, weakly interacting neutrinos, are challenging to observe. Here, we consider a scenario where MeV-mass DM exclusively annihilates to the third neutrino mass eigenstate, which is predominantly of tau and muon flavor. In such a scenario, the potential detection rate of the neutrinos originating from the DM annihilation in our Galaxy in the conventional detectors would be suppressed by up to approximately two orders of magnitude. This is because the best sensitivity of such detectors for neutrinos with energies below approximately 100 MeV is for electron neutrino flavor. In this work, we highlight the potential of large-scale DM detectors in uncovering such signals in the tens of MeV range of DM masses. In addition, we discuss how coincident signals in direct detection DM experiments and upcoming neutrino detectors such as DUNE, Hyper-Kamiokande, and JUNO could provide new perspectives on the DM problem. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observables for recoil identification in high-definition Gas Time Projection Chambers

Directional detection of nuclear recoils is broadly desirable in nuclear and particle physics. At low recoil energies, this capability may be used to confirm the cosmological origin of a dark matter signal, to penetrate the so-called neutrino floor, or to distinguish between different neutrino sources. Gas Time Projection Chambers (TPCs) can enable directional recoil detection if the readout granularity is sufficiently high, as is the case when micro-pattern gaseous detectors (MPGDs) are utilized. A key challenge in such detectors is identifying and rejecting background electron recoil events caused by gamma rays from radioactive contaminants in the detector materials and the environment. We define new observables that can distinguish electron and nuclear recoils, even at keV-scale energies, based on the simulated ionization's topology. Here we perform a simulation study that shows these observables outperform the traditionally used discriminant, dE/dx, by up to three orders of magnitude. Furthermore, these new observables work well even at ionization energies well below 10keV and remain robust even in the regime where directionality fails.

79 ASTRONOMY AND ASTROPHYSICS↗

Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients

We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.

(S2-FT-IR)↗

Mechanically flexible mid-wave infrared imagers using black phosphorus ink films

The mid-wave infrared (MWIR) spectral range (λ = 3–8 μm) enables important sensing and imaging applications, including non-invasive bioimaging, night vision, and autonomous navigation. Commercial MWIR photodetectors are limited to rigid imagers based on heteroepitaxial materials. There is an emerging need for mechanically flexible MWIR imagers to broaden their functionality and practicality. Recently, photodetectors using van der Waals (vdW) black phosphorus (BP) flakes have demonstrated highly sensitive room-temperature photodetection. Additionally, vdW materials are solution-processable, facilitating scalable processing and flexible device fabrication. In this work, we present flexible MWIR imagers consisting of photodiodes fabricated on thin plastic substrates using BP ink films. We demonstrate mechanically robust responsivity up to 2.5-mm bending radii and after 5000 bending cycles. Leveraging this flexibility, we achieve full-azimuthal imaging, detecting directional light sources with precision. These results establish a scalable approach for large-area, conformable MWIR imaging and pave the way for integration with flexible electronics.

Wijaya, Theodorus Jonathan↗

Exploring the Nucleon Structure via Deep Electroproduction Processes

Understanding the internal structure of the nucleon is a fundamental goal of modern physics, which aims at a comprehensive framework describing the internal dynamics of quarks and gluons. Among other structure functions, Generalized Parton Distributions (GPDs) offer a powerful framework for describing the nucleon dynamics by correlating the longitudinal momentum and the transverse position of its internal partons. Such a correlation provides a three-dimensional picture of the nucleon and enables access to fundamental properties, including the internal pressure distributions and the parton’s angular momentum contribution to the nucleon's total spin, thereby playing a central role in resolving the nucleon spin puzzle. At the Thomas Jefferson National Facility (JLab), polarized electron beam experiments allow for probing GPDs through the measurement of hard exclusive processes. Among the cleanest experimental channels, we find the electro-production of a real photon through the Deeply Virtual Compton Scattering (DVCS) mechanism. The first data-taking period of the CLAS12 program, taking place in 2018, allowed for unique DVCS Beam Spin Asymmetry (BSA) measurements in the phase space covered by a 10.6 GeV polarized electron beam impinging on an unpolarized liquid hydrogen target. Although detecting all final-state particles ensures exclusivity of the process, conservation laws indicate that it is not mandatory. I adopt an approach omitting the direct detection of the recoil proton, providing a simplified yet effective event selection strategy that boosts statistics and gives access to a larger phase space sensitive to the underlying GPD dynamics through BSA and cross section measurements. The Double DVCS (DDVCS) process promises a dedicated mapping of GPDs. Contributing to the electro-production of a lepton pair cross-section, the DDVCS reaction extends DVCS by allowing the final-state photon to be virtual, enriching the kinematic phase space and providing unique access to the internal correlations encoded by GPDs. A feasibility study is conducted to assess the potential of future DDVCS measurements at Jefferson Lab and the future Electron-Ion Collider (EIC). While Jefferson Lab will provide DDVCS measurements in the valence region through the SoLID$\mu$ and $\mu$CLAS12 experimental projects, in the long term, the EIC will provide complementary measurements in the sea region, both accessing unprecedented information about GPDs in a phase space region otherwise inaccessible. Taken together, these investigations demonstrate both the current capabilities and future opportunities for probing GPDs through exclusive processes. The experimental analysis of DVCS at CLAS12 provides precise measurements within an established framework, while the phenomenological study of DDVCS opens the door to richer and more comprehensive explorations with future detectors and facilities.

Alvarado, Juan [Université Paris-Saclay: Gif-sur-Y↗

Spin-dependent dark matter scattering in quasi-two-dimensional magnets

We study the prospects of detecting dark matter coupled to the spin of the electron, such that it may scatter and excite magnons—collective excitations of electronic spins. We show that materials exhibiting long-range magnetic order where the spins are coupled only along a plane may act as directional dark matter detectors. These quasi-two-dimensional materials possess anisotropic dispersion relations and structure functions which induce a sidereal modulation in the excitation rate. We calculate the expected signal rate for some candidate (anti)ferromagnets, demonstrating a possible route to the direct detection of spin-dependent dark matter in the keV to MeV mass range.

Dark matter direct detection↗

Trocylation of 3-quinuclidinol, a key marker for the chemical warfare agent 3-quinuclidinyl benzilate, for its enhanced detection at low levels in complex soil matrices by electron ionization gas chromatography–mass spectrometry

Detection of 3-quinuclidinol (3Q), a marker for the chemical warfare agent 3-quinuclidinyl benzilate, is very difficult by gas chromatography–mass spectrometry (GC/MS), providing low, broad signals even when analyzed in isolated form. Therefore, a method that can convert 3Q into a substrate with enhanced detectability by GC/MS would be an important tool for its analysis. 2,2,2-Trichloroethoxycarbonyl chloride (TrocCl) was used in the derivatization of 3Q in three different soils of varying composition and total organic content (Virginia type A soil, Nebraska EPA standard soil and Ottawa sand) when present at a 10 μg g -1 concentration in each. A direct derivatization protocol and one involving the pre-extraction of the analyte were evaluated for their individual efficiencies and subsequent analysis using electron ionization GC/MS. The practical derivatization of 3Q, when present at low levels (10 μg g -1 ) in three different soil matrices, was found to be rapid (1 h) and to take place smoothly at ambient temperature (and as low as 4°C). The method detection limit was determined to be 30 ng mL -1 for the Virginia type A soil, 49 ng mL -1 for the Nebraska EPA standard soil and 72 ng mL -1 for the Ottawa sand sample. An expedient and practical derivatization method for 3Q, a chemical warfare degradation product difficult to detect by GC/MS, has been realized using trichloroethyl chloroformate. The reaction provides 3Q-Troc, a derivative with better detectability than 3Q by electron ionization GC/MS such as peak sharpness and a unique mass spectrum for its unambiguous identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of uncompensated magnetization at the interface of an epitaxial antiferromagnetic insulator

We have probed directly the temperature and magnetic field dependence of pinned uncompensated magnetization at the interface of antiferromagnetic FeF 2 with Cu, using FeF 2 -Cu-Co spin valves. Electrons polarized by the Co layer are scattered by the pinned uncompensated moments at the FeF 2 -Cu interface giving rise to giant magnetoresistance. We determined the direction and magnitude of the pinned uncompensated magnetization at different magnetic fields and temperatures using the angular dependencies of resistance. The strong FeF 2 anisotropy pins the uncompensated magnetization along the easy axis independent of the cooling field orientation. Most interestingly, magnetic fields as high as 90 kOe cannot break the pinning at the FeF 2 -Cu interface. This proves that the pinned interfacial magnetization is strongly coupled to the antiferromagnetic order inside the bulk FeF 2 layer. Studies as a function of FeF2 crystalline orientation show that uncompensated spins are only detected in a spin valve with (110) crystal orientation, but not in valves containing FeF 2 (100) and FeF 2 (001). This observation is in agreement with symmetry-related considerations which predict the equilibrium boundary magnetization for the FeF 2 (110) layer.

36 MATERIALS SCIENCE↗

Electronic Spin Relaxation and Clustering in High-Pressure High-Temperature Synthesized Microcrystalline Diamond Particles with Reduced Nitrogen Content

The negatively charged nitrogen-vacancy (NV – ) color center in diamonds is widely studied because of numerous applications of this unique quantum system in sensing and quantum information sciences. While substitutional nitrogen is required to form the NV – centers in diamond, it also yields other paramagnetic defects─primarily the neutrally charged substitutional nitrogen centers (P1)─that decrease NV – spin coherence, which in turn degrades performance in applications. Herein, we investigate high-pressure high-temperature synthesized diamond microparticles (ca. 140–185 μm) having lower─ranging from 3 to 38 ppm─than the typical nitrogen content of type 1b diamond ( ca. 100 ppm and higher) typically used for the production of fluorescent diamond particles with NV – centers. A suite of electron paramagnetic resonance, optically detected magnetic resonance, and nuclear magnetic resonance methods are used to characterize spin properties of P1 and NV – centers in the particles. Upon decreasing the nitrogen content from 29 to 3 ppm, the ensemble NV – T 2 relaxation time increased by about 3-fold as measured directly in the Hahn Echo experiment at magnetic field of 1.2 T. Analysis of electronic relaxation of P1 centers revealed the existence of at least two distinct populations of P1 centers, consisting of fast and slower relaxing spins and allowed for an estimation of local concentrations. Even with <10 ppm nitrogen contents, the analysis indicated a highly heterogeneous distribution of P1 centers, suggesting the possibility of P1 spin clustering even at low nitrogen concentrations. The combined data demonstrate that the particles prepared from HPHT diamond with a low nitrogen content offer improved spin properties that are beneficial for NV – sensing applications.

Carbon↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗