Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

ATLAST Detector Needs for Direct Spectroscopic Biosignature Characterization in the Visible and Near-IR

Are we alone? Answering this ageless question will be a major focus for astrophysics in coming decades. Our tools will include unprecedentedly large UV-Optical-IR space telescopes working with advanced coronagraphs and starshades. Yet, these facilities will not live up to their full potential without better detectors than we have today. To inform detector development, this paper provides an overview of visible and near-IR (VISIR; lambda = 0.4 − 1.8 micrometers) detector needs for the Advanced Technology Large Aperture Space Telescope (ATLAST), specifically for spectroscopic characterization of atmospheric biosignature gasses. We also provide a brief status update on some promising detector technologies for meeting these needs in the context of a passively cooled ATLAST.

spectroscopic↗

Primary track recovery in high-definition gas time projection chambers

Abstract We develop and validate a new algorithm called primary track recovery () that effectively deconvolves known physics and detector effects from nuclear recoil tracks in gas time projection chambers (TPCs) with high-resolution readout. This gives access to the primary track charge, length, and vector direction (helping to resolve the “head-tail” ambiguity). Additionally, provides a measurement of the transverse and longitudinal diffusion widths, which can be used to determine the absolute position of tracks in the drift direction for detector fiducialization. Using simulated helium recoils in an atmospheric pressure TPC with a 70:30 mixture of $$\hbox {He:CO}_2$$ He:CO 2 we compare the performance of to traditional methods for all key track variables. We find that the algorithm reduces reconstruction errors, including those caused by charge integration, for tracks with mean length-to-width ratios 1.4 and above, corresponding to recoil energies of 20 keV and above in the studied TPCs. We show that improves on existing methods for head-tail disambiguation, particularly for highly inclined tracks, and improves the determination of the absolute position of recoils on the drift axis via transverse diffusion. We find that can partially recover charge structure integrated out by the detector in the z direction, but that its determination of energy and length have worse resolution compared to existing methods. We use experimental data to qualitatively verify these findings and discuss implications for future directional detectors at the low-energy frontier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of fast neutron direction in segmented organic detectors using deep learning

A method for reconstructing the direction of a fast neutron source using a segmented organic scintillator-based detector and deep learning model is proposed and analyzed. Here, the model is based on recurrent neural network, which can be trained by a sequence of data obtained from an event recorded in the detector and suitably pre-processed. The performance of deep learning-based model is compared with the conventional double-scatter detection algorithm in reconstructing the direction of a fast neutron source. With the deep learning model, the uncertainty in source direction of 0.301 rad is achieved with 100 neutron detection events in a segmented cubic organic scintillator detector with a side length of 46 mm. To reconstruct the source direction with the same angular resolution as the double-scatter algorithm, the deep learning method requires 75% fewer events. Application of this method could augment the operation of segmented detectors operated in the neutron scatter camera configuration for applications such as special nuclear material detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrathin and Ultrasensitive Direct X‐ray Detector Based on Heterojunction Phototransistors

Abstract Most contemporary X‐ray detectors adopt device structures with non/low‐gain energy conversion, such that a fairly thick X‐ray photoconductor or scintillator is required to generate sufficient X‐ray‐induced charges, and thus numerous merits for thin devices, such as mechanical flexibility and high spatial resolution, have to be compromised. This dilemma is overcome by adopting a new high‐gain device concept of a heterojunction X‐ray phototransistor. In contrast to conventional detectors, X‐ray phototransistors allow both electrical gating and photodoping for effective carrier‐density modulation, leading to high photoconductive gain and low noise. As a result, ultrahigh sensitivities of over 10 5 μC Gy air −1 cm −2 with low detection limit are achieved by just using an ≈50 nm thin photoconductor. The employment of ultrathin photoconductors also endows the detectors with superior flexibility and high imaging resolution. This concept offers great promise in realizing well‐balanced detection performance, mechanical flexibility, integration, and cost for next‐generation X‐ray detectors.

Gao, Yuanhong↗

Direct-Current Unbalance Detector

Short circuits to ground indicated by voltage changes. Current transducer connected in bridge circuit with floating 30-Vdc power supply measures voltage unbalance between positive and negative powerlines and ground. Detection circuit output swings higher or lower than normal balanced condition voltage to signify unbalance toward positive or negative side respectively. Circuit configuration adaptable to monitor 4- to 20-mA current loops often found in industrial controls.

Wagner, A. P.↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well-shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

End-to-End Physics Event Classification with CMS Open Data: Applying Image-Based Deep Learning to Detector Data for the Direct Classification of Collision Events at the LHC

This paper describes the construction of novel end-to-end image-based classifiers that directly leverage low-level simulated detector data to discriminate signal and background processes in pp collision events at the Large Hadron Collider at CERN. To better understand what end-to-end classifiers are capable of learning from the data and to address a number of associated challenges, we distinguish the decay of the standard model Higgs boson into two photons from its leading background sources using high-fidelity simulated CMS Open Data. We demonstrate the ability of end-to-end classifiers to learn from the angular distribution of the photons recorded as electromagnetic showers, their intrinsic shapes, and the energy of their constituent hits, even when the underlying particles are not fully resolved, delivering a clear advantage in such cases over purely kinematics-based classifiers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reactor antineutrino directionality measurement with the PROSPECT-I detector

The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. Here, in this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of φ = 40.8° ± 0.7° and θ= 98.6° ± 0.4°, the PROSPECT-I detector is able to reconstruct an average neutrino direction of φ = 39.4° ± 2.9° and θ = 97.6° ± 1.6°. This measurement is made with approximately 48 000 Inverse Beta Decay signal events and is the most precise directional reconstruction of reactor antineutrinos to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental demonstration and modeling of a robotic neutron detector with spectral and directional sensitivity for treaty verification

International safeguards and arms control agreements often require labor-intensive, intrusive onsite inspections to perform verification tasks. The ability to localize a neutron source and/or characterize a neutron field may be imperative for identifying anomalies. We are interested in the role of autonomous mobile robots, which, if designed properly, may be more effective and efficient and less intrusive than their human counterparts. Toward developing such a capability, we, for this study, have constructed the N-SpecDir Bot, comprised of three boron-coated straw detectors azimuthally-distributed within a cylinder of high-density polyethylene, which is mounted on an omni-directional robotic platform. Our N-SpecDir Bot is specifically designed to provide spectral and directional sensitivity, in addition to gross counts, by utilizing the signals from the three detectors. The detection system has been extensively characterized by MCNP modeling, which has been benchmarked to experiments conducted at the Princeton Plasma Physics Laboratory. We demonstrate the spectral and directional sensitivity experimentally and in simulation, and provide a simple yet robust method for directional measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗

Apparatus and method for stabilized phase detection for binary signal tracking loops

Apparatus and method is presented for phase detection in binary signal tracking loops wherein two bandpass detectors are alternately interchanged between electrical connection with two local code reference tracking signals in order to cancel any adverse effect of gain imbalance in the bandpass detectors and direct current offset or drift. The detectors are time shared in multiplex fashion between the two local reference signals.

Hopkins, P. M.↗

In-Flight Performance of the Soft X-Ray Spectrometer Detector System on ASTRO-H

The SXS instrument was launched aboard the Astro-H observatory on February 17, 2016. The SXS spectrometer is based on a high sensitivity x-ray calorimeter detector system that has been successfully deployed in many ground and sub-orbital spectrometers. The instrument was to provide essential diagnostics for nearly every class of x-ray emitting objects from the atmosphere of Jupiter to the outskirts of galaxy clusters, without degradation for spatially extended objects. The SXS detector system consisted of a 36-pixel cryogenic microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the detector system demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous band-pass from below 0.3 keV to above 12 keV with a timing precision better than 100 microsecond. In addition, a solid-state anti-coincidence detector was placed directly behind the detector array for background suppression. The detector error budget included the measured interference from the SXS cooling system and the spacecraft. Additional margin for on-orbit gain-stability, and on-orbit spacecraft interference were also included predicting an on-orbit performance that meets or exceeds the 7 eV FWHM at 6 keV requirement. The actual on-orbit spectral resolution was better than 5 eV FWHM at 6 keV, easily satisfying the instrument requirement. Here we discuss the actual on-orbit performance of the SXS detector system and compare this to performance in pre-flight testing and the on-orbit predictions. We will also discuss the on-orbit gain stability, additional on-orbit interference, and measurements of the on-orbit background.

X-ray astrophysics↗

Direct current response of a thin scCVD diamond detector under increased applied field to 14.1 MeV neutrons

An avalanche effect yielding inherent gain can be exploited in thin, single-crystal chemical vapor deposition (scCVD) diamond. It occurs when a high enough bias is applied across the diamond thickness while avoiding breakdown. This charge multiplication effect was studied previously with alpha particles and heavy ions either by using the transient current technique or by measuring the energy spectrum. The measurements we obtained to evaluate the charge multiplication performance of a 10 μm thick scCVD diamond detector used a novel approach—we employed an electrometer to characterize the response of the detector by performing directly coupled current measurements (time-averaged charge, at 1 Hz sampling) when exposed to 14.1 MeV neutrons from deuterium-tritium fusion. We measured both the dark and irradiated currents from the detector over a range of applied displacement field values from 2 to 75 V/μm. A histogram method with central mean and standard deviation width was used to determine the current over each measurement duration typically from 100 to 300 seconds. The dark-subtracted irradiated current (i.e., contrast) was used to evaluate the gain of the detector at each applied displacement field. The contrast at an applied displacement field between 15 and 20 V/μm was higher than the expected linear increase in contrast proportional to the increased applied bias, indicating the possible presence of avalanche events in the diamond. The detector response also indicated possible polarization and charge depletion effects. These results provide an opportunity to further explore the use of thin scCVD diamond as a fast neutron current mode detector with inherent gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding Formation of Irradiation-Induced Defects through 4D-STEM, Electron Tomography, and WBDF-STEM

A major challenge in advancing nuclear materials for next-generation fission and proposed fusion reactors is to comprehensively understand the formation of irradiation-induced defects. Here it is essential to correlate the evolution of irradiation-induced defects and the degradation of mechanical properties, as they collectively dictate the material's lifespan and ensure nuclear safety. Scanning transmission electron microscopy (STEM) based techniques have emerged as indispensable tools for irradiation-induced defect characterization, offering high spatial resolution imaging and chemical analysis, such as electron energy loss spectroscopy (EELS) and energy dispersive X-ray spectroscopy (EDXS). These techniques have been effectively used to obtain an atomic-scale view of the defect structure. Recent advances in electron microscopy, particularly in 4D-STEM, offer detailed insight into microstructural evolution by capturing full 2D diffraction patterns at every pixel position. Using high-speed direct electron detectors, this technology generates a four-dimensional dataset, overcoming the limitations of traditional STEM imaging.

36 MATERIALS SCIENCE↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Direct-Write Printing on Three-Dimensional Geometries for Miniaturized Detector and Electronic Assemblies

Direct-write printing techniques will enable new detector assemblies that were not previously possible with traditional assembly processes. Detector concepts were manufactured using this technology to validate repeatability. Additional detector applications and printed wires on a 3-dimensional magnetometer bobbin will be designed for print. This effort focuses on evaluating performance for direct-write manufacturing techniques on 3-dimensional surfaces. Direct-write manufacturing has the potential to reduce mass and volume for fabrication and assembly of advanced detector concepts by reducing trace widths down to 10 microns, printing on complex geometries, allowing new electronic concept production, and reduced production times of complex those electronics.

Direct-write printing↗