Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digitized waveform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

ASIC Scoping Study Final Report

This report documents the results and findings of a one-year scoping study investigating multichannel readout application specific integrated circuits (ASICs) for interfacing to, and processing data from, silicon photomultiplier (SiPM) arrays. We document ASIC desired and required specifications for four applications supporting national security mission areas: neutron radiography, associated particle imaging, and two versions of kinematic neutron imaging cameras. While each application has a few unique requirements that stress capability, there is generally good agreement among most. Two recently developed ASIC devices were evaluated in a system-like configuration by interfacing these to scintillator crystals exposed to gamma and neutron sources. The 64-channel ORNL device delivered functional capability while meeting most mission requirements for neutron radiography. The Nalu Scientific device, a 32-channel full waveform digitizer, did not demonstrate reliable neutron / gamma separation but it is unclear if this was an ASIC issue or problems with test setup or firmware. A literature survey of other commercial and academic ASICs was undertaken to with the conclusion that existing devices do not meet all requirements.

42 ENGINEERING↗

Neutron Emission Characteristics of Two Mixed-Oxide Fuels: Simulations and Initial Experiments

Simulations and experiments have been carried out to investigate the neutron emission characteristics of two mixed-oxide (MOX) fuels at Idaho National Laboratory (INL). These activities are part of a project studying advanced instrumentation techniques in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and it's Materials Protection, Accounting, and Control for Transmutation (MPACT) campaign. This analysis used the MCNP-PoliMi Monte Carlo simulation tool to determine the relative strength and energy spectra of the different neutron source terms within these fuels, and then used this data to simulate the detection and measurement of these emissions using an array of liquid scintillator neutron spectrometers. These calculations accounted for neutrons generated from the spontaneous fission of the actinides in the MOX fuel as well as neutrons created via (alpha,n) reactions with oxygen in the MOX fuel. The analysis was carried out to allow for characterization of both neutron energy as well as neutron coincidences between multiple detectors. Coincidences between prompt gamma rays and neutrons were also analyzed. Experiments were performed at INL with the same materials used in the simulations to benchmark and begin validation tests of the simulations. Data was collected in these experiments using an array of four liquid scintillators and a high-speed waveform digitizer. Advanced digital pulse-shape discrimination algorithms were developed and used to collect this data. Results of the simulation and modeling studies are presented together with preliminary results from the experimental campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital modulator

Digital modulator for reshaping partially degraded digital waveforms

Winkelstein, R.↗

One way Doppler Extractor. Volume 2: Digital VCO technique

A feasibility analysis and trade-offs for a one-way Doppler extractor using digital VCO techniques is presented. The method of Doppler measurement involves the use of a digital phase lock loop; once this loop is locked to the incoming signal, the precise frequency and hence the Doppler component can be determined directly from the contents of the digital control register. The only serious error source is due to internally generated noise. Techniques are presented for minimizing this error source and achieving an accuracy of 0.01 Hz in a one second averaging period. A number of digitally controlled oscillators were analyzed from a performance and complexity point of view. The most promising technique uses an arithmetic synthesizer as a digital waveform generator.

Nossen, E. J.↗

Pulsed multiwavelength laser ranging system

A pulsed multiwavelength laser ranging system for measuring atmospheric delay was built and tested, and its theoretical performance limits were calculated. The system uses a dye modelocked ND:YAG laser, which transmits 70 psec wide pulses simultaneously at 1064, 532, and 355 nm. The differential delay of the 1064 and 355 nm pulses is measured by a specially calibrated waveform digitizer to estimate the dry atmospheric delay. The delay time of the 532 nm pulse is used to measure the target distance. Static crossed field photomultipliers are used as detectors for all wavelengths. Theoretical analysis shows that path curvature and atmospheric turbulence are fundamental limits to the ranging accuracy of both single and multicolor systems operating over horizontal paths. For two color systems, an additional error is caused by the uncertainty in the path averaged water vapor. The standard deviation of the multicolor instrument's timing measurements is directly proportional to the laser pulse width plus photomultiplier jitter divided by the square root of the received photoelectron number. The prototype system's maximum range is km, which is limited by atmospheric and system transmission losses at 355 nm. System signal detection and false alarm calculations are also presented.

Abshire, J. B.↗

Multicolor laser altimeter for barometric measurements over the ocean - Experimental

Measurement theory and results from testing a breadboard multiwavelength (355-, 532- and 1064-nm) laser altimeter over horizontal paths are presented. They show that pressure accuracies of 3 mbar can be achieved when ranging at nadir to cube corner targets when using a 500-psec resolution waveform digitizer and utilizing new calibration techniques. Streak camera-based receivers will be required for the same or higher accuracies when ranging to the ocean surface. System design calculations for aircraft and spaceborne experiments are presented.

Abshire, J. B.↗

Embedded gage impact study

Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.

Schramm, S. W.↗

Monopole search below the Parker limit with the MACRO detector at Gran Sasso

The MACRO detector approved for the Gran Sasso Underground Laboratory in Italy will be the first capable of performing a definitive search for super-massive grand unified theory (GUT) monopoles at a level significantly below the Parker flux limit of 10 to the minus 15th power square centimeters Sr(-1) 5(-1). GUT monopoles will move at very low velocities (V approx. 0.001 c) relative to the Earth and a multifaceted detection technique is required to assume their unambiguous identification. Calculations of scintillator response to slow monopoles and measurements of scintillation efficiency for low energy protons have shown that bare monopoles and electrically charged monopoles moving at velocities as low as 5 x .0001 c will produce detectable scintillation signals. The time-of-flight between two thick (25 cm) liquid scintillation layers separated by 4.3m will be used in conjunction with waveform digitization of signals of extended duration in each thick scintillator to provide a redundant signature for slow penetrating particles. Limited streamer tubes filled with He and n-pentane will detect bare monopoles with velocities as low as 1 x 0.0001 c by exploiting monopole induced level mixing and the Penning effect.

Tarle, G.↗

Measuring the Interlaminar Shear Strengths of Composites

Acousto-ultrasonic technique utilizing computer and waveform digitizer developed for nondestructive evaluation (NDE) of composite materials. Technique employed on filament-wound composite (FWC) specimens cut from sample segments of graphite/epoxy cylinders. Developed for use on large composite structures to verify integrity and assure reusability. Similar applications of technique anticipated for variety of composite structures, such as pipelines and storage tanks.

Kautz, Harold E.↗

The Geoscience Laser Altimetry/Ranging System (GLARS)

The Geoscience Laser Altimetry Ranging System (GLARS) is a highly precise distance measurement system to be used for making extremely accurate geodetic observations from a space platform. It combines the attributes of a pointable laser ranging system making observations to cube corner retroreflectors placed on the ground with those of a nadir looking laser altimeter making height observations to ground, ice sheet, and oceanic surfaces. In the ranging mode, centimeter-level precise baseline and station coordinate determinations will be made on grids consisting of 100 to 200 targets separated by distances from a few tens of kilometers to about 1000 km. These measurements will be used for studies of seismic zone crustal deformations and tectonic plate motions. Ranging measurements will also be made to a coarser, but globally distributed array of retroreflectors for both precise geodetic and orbit determination applications. In the altimetric mode, relative height determinations will be obtained with approximately decimeter vertical precision and 70 to 100 meter horizontal resolution. The height data will be used to study surface topography and roughness, ice sheet and lava flow thickness, and ocean dynamics. Waveform digitization will provide a measure of the vertical extent of topography within each footprint. The planned Earth Observing System is an attractive candidate platform for GLARS since the GLAR data can be used both for direct analyses and for highly precise orbit determination needed in the reduction of data from other sensors on the multi-instrument platform. (1064, 532, and 355 nm)Nd:YAG laser meets the performance specifications for the system.

Cohen, S. C.↗

Fast Data Acquisition For Mass Spectrometer

New equipment has speed and capacity to process time-of-flight data. System relies on fast, compact waveform digitizer with 32-k memory coupled to personal computer. With digitizer, system captures all mass peaks on each 25- to 35-microseconds cycle of spectrometer.

Lincoln, K. A.↗

High-resolution measurements of surface topography with airborne laser altimetry and the global positioning system

Recently, an airborne lidar system that measures laser pulse time-of-flight and the distortion of the pulse waveform upon reflection from earth surface terrain features was developed and is now operational. This instrument is combined with Global Positioning System (GPS) receivers and a two-axis gyroscope for accurate recovery of aircraft position and pointing attitude. The laser altimeter system is mounted on a high-altitude aircraft platform and operated in a repetitively-pulsed mode for measurements of surface elevation profiles at nadir. The laser transmitter makes use of recently developed short-pulse diode-pumped solid-state laser technology in Q-switched Nd:YAG operating at its fundamental wavelength of 1064 nm. A reflector telescope and silicon avalanche photodiode are the basis of the optical receiver. A high-speed time-interval unit and a separate high-bandwidth waveform digitizer under microcomputer control are used to process the backscattered pulses for measurements of terrain. Other aspects of the lidar system are briefly discussed.

Garvin, James B.↗

Ranging performance of satellite laser altimeters

Topographic mapping of the earth, moon and planets can be accomplished with high resolution and accuracy using satellite laser altimeters. These systems employ nanosecond laser pulses and microradian beam divergences to achieve submeter vertical range resolution from orbital altitudes of several hundred kilometers. Here, we develop detailed expressions for the range and pulse width measurement accuracies and use the results to evaluate the ranging performances of several satellite laser altimeters currently under development by NASA for launch during the next decade. Our analysis includes the effects of the target surface characteristics, spacecraft pointing jitter and waveform digitizer characteristics. The results show that ranging accuracy is critically dependent on the pointing accuracy and stability of the altimeter especially over high relief terrain where surface slopes are large. At typical orbital altitudes of several hundred kilometers, single-shot accuracies of a few centimeters can be achieved only when the pointing jitter is on the order of 10 mu rad or less.

Gardner, Chester S.↗

Parameterization of asymmetry in magnetoacoustic emission by numerical processes

Two methods for processing the digitized waveform data obtained from magnetoacoustic emission measurements on a high-strength steel are investigated. Two different techniques to obtain an asymmetry parameter are presented. It is shown that the variation in this asymmetry parameter from five embrittled samples and one unembrittled steel sample can be related to the impact toughness and is not dependent on the magnetic field strength. This technique is nondestructive and is shown to determine the normalized impact toughness of a high-strength steel to better than 14 percent in the decade of interest. A comparison of a magnetoacoustic emission burst and pickup coil output from an unembrittled steel sample and an embrittled sample is illustrated.

Birt, E. A.↗

Ranging performance of satellite laser altimeters

Detailed expressions for the range and pulse width measurement accuracies are developed and used to evaluate the ranging performances of several satellite laser altimeters currently under development by NASA for launch during the next decade. The analysis includes the effects of the target surface characteristics, spacecraft pointing jitter, and waveform digitizer characteristics. The results show that ranging accuracy is critically dependent on the pointing accuracy and stability of the altimeter especially over high relief terrain where surface slopes are large. At typical orbital altitudes of several hundred kilometers, single-shot accuracies of a few centimeters can be achieved only when the pointing jitter is on the order of 10 microrad or less.

Gardner, Chester S.↗

Two color satellite laser ranging upgrades at Goddard's 1.2m telescope facility

The ranging laboratory at Goddard's 1.2 m telescope tracking facility has recently been upgraded to include a single photoelectron sensitive Hamamatsu streak camera-based range receiver which uses doubled and tripled Nd:YAG frequencies for satellite laser ranging. Other ranging system upgrades include a new continuum laser, which will deliver up to 30 millijoules (mJ) at both 532 and 355 nm at a pulsewidth of 30 picoseconds (FWHM), and replacement of both ranging and tracking computers with COMPAQ 386 based systems. Preliminary results using a photomultiplier-tube based receiver and waveform digitizer indicate agreement within the accuracy of the measurement with the theoretical Marini and Murray model for atmospheric refraction. Two color streak camera measurements are used to further analyze the accuracy of these and other atmospheric refraction models.

Zagwodzki, Thomas W.↗

Laser altimetry simulator. Version 3.0: User's guide

A numerical simulator of a pulsed, direct detection laser altimeter has been developed to investigate the performance of space-based laser altimeters operating over surfaces with various height profiles. The simulator calculates the laser's optical intensity waveform as it propagates to and is reflected from the terrain surface and is collected by the receiver telescope. It also calculates the signal and noise waveforms output from the receiver's optical detector and waveform digitizer. Both avalanche photodiode and photomultiplier detectors may be selected. Parameters of the detected signal, including energy, the 50 percent rise-time point, the mean timing point, and the centroid, can be collected into histograms and statistics calculated after a number of laser firings. The laser altimeter can be selected to be fixed over the terrain at any altitude. Alternatively, it can move between laser shots to simulate the terrain profile measured with the laser altimeter.

Abshire, James B.↗

PSIDD: A Post-Scan Interactive Data Display System for Ultrasonic Scans

An ultrasonic data display system was developed at NASA Lewis Research Center that allows the user to interactively examine digitized waveforms and processed information associated with any specific scan location of an ultrasonic contact scan. This information is displayed on a video display monitor and includes acquired time-domain waveforms, frequency-domain magnitude and phase spectra, and ultrasonic properties (pulse velocity, phase velocity, reflection coefficient, attenuation coefficient, attenuation coefficient error) as a function of frequency for a material. This report describes the system features and illustrates the system's usefulness for nondestructive materials characterization.

Roth, Don J.↗