Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

103 records · Page 6

Localized phase contrast imaging at the Wendelstein 7-X stellarator

In its basic form, phase contrast imaging (PCI) provides line-integrated measurements of electron density fluctuations in plasmas. As turbulent fluctuations in magnetically confined plasmas have wave vectors almost perpendicular to the background magnetic field, the signals scattered by fluctuations from different parts of the PCI line-of-sight (LoS) are spatially separated in focal planes of the plasma. This allows localized PCI measurements by placing a mask in such a plane, to only permit signals from specific parts of the LoS to reach the PCI detectors. The present paper describes modeling and design of localization masks for the PCI system at the Wendelstein 7-X (W7-X) stellarator as well as the first results obtained using the masks in the recent long-pulse W7-X experimental campaign. During this project, we have extended the theory describing the mask response within the Fraunhofer diffraction model. As a novel development, we show from first principles that the mask response is determined by the fraction of power of the scattered beam spots that passes the mask. These insights have been used to select the W7-X mask design, consisting of a circular cutout, allowing the unscattered beam spot to pass the mask, with wedges covering a fixed angular range outside the central cutout. In the recent W7-X experimental campaign, the masks have verified the location of the main turbulence features observed by the PCI system and provided new information about the location of short-wavelength magnetohydrodynamic modes.

Physics↗

Time-reversed Young’s experiment: Deterministic, diffractionless second-order interference effect

The classic Young’s double-slit experiment exhibits first-order interference, producing alternating bright and dark fringes shaped by the diffraction effect of the slits. In contrast, here we demonstrate that its time-reversed configuration generates an ideal, deterministic second-order ‘ghost’ interference pattern free from diffraction and first-order effects with the use of only a position-fixed detector. The pattern’s size is governed by the dimensions of the ‘effectively extended light source’ formed by point emitter(s). Beyond highlighting the nonreciprocal physics between the two configurations, this system unlocks a range of novel phenomena inaccessible in traditional double-slit experiments. These include fully programmable, digitized interference fringe formations and the ability to align the pattern plane with the source plane on the same side of the setup. Remarkably, our proposed experiment achieves these outcomes without relying on nonclassical correlations or quantum entanglement. Here, by restoring time-reversal symmetry and eliminating diffraction, our theoretical analysis reveals that this approach offers exciting potential for advancing optical imaging and sensing technologies with improved transverse and longitudinal phase-shift sensitivity and resolution limit beyond current limitations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Deep learning of interface structures from simulated 4D STEM data: cation intermixing vs. roughening ∗

Abstract Interface structures in complex oxides remain an active area of condensed matter physics research, largely enabled by recent advances in scanning transmission electron microscopy (STEM). Yet the nature of the STEM contrast in which the structure is projected along the given direction precludes separation of possible structural models. Here, we utilize deep convolutional neural networks (DCNN) trained on simulated 4D STEM datasets to predict structural descriptors of interfaces. We focus on the widely studied interface between LaAlO 3 and SrTiO 3 , using dynamical diffraction theory and leveraging high performance computing to simulate thousands of possible 4D STEM datasets to train the DCNN to learn properties of the underlying structures on which the simulations are based. We test the DCNN on simulated data and show that it is possible (with >95% accuracy) to identify a physically rough from a chemically diffuse interface and create a DCNN regression model to predict step positions. We quantify the applicability of the model to different thicknesses and the transferability of the approach. The method shown here is general and can be applied for any inverse imaging problem where forward models are present.

42 ENGINEERING↗

Pulsed laser synthesis of mesoporous metal chalcogenide thin films

Mesoporous films of the metal chalcogenide B-FeSe were grown on MgO substrates by KrF pulsed laser deposition (PLD) in an argon background. At 100 mTorr, gated intensified charge-coupled device imaging and ion probe measurements showed that the plasma plume responsible for crystal growth initially comprised three components, with distinct expansion velocities. Plume interactions with the substrate heater and ablation target gave rise to complex dynamics, including collisions between the charged leading edge—rebounding between the substrate and the target—and slower-moving species in the plume interior. Film growth was dominated by species with kinetic energies ≤0.5 eV/atom. X-ray reflectivity revealed that films grown in this environment—with a substrate temperature of 350 ° C, a laser fluence of 1.0 J cm −2 , and a 7.5 mm 2 spot area—formed a porous framework with 15% porosity. Atomic force microscopy showed surface features that suggest pore sizes below 100 nm. X-ray diffraction indicated that the porous films were epitaxial with respect to the substrate and likely grew by oriented-attachment of gas-phase molecular clusters or very small nanoparticles, in contrast to the conventional epitaxy of vacuum films from atomic constituents. The in-plane orientation of the mesoporous films was B-FeSe [100]||[110] MgO, attributed to the soft landing of pre-formed crystallites on the MgO substrates, where protruding Se rows of B-FeSe aligned with corrugations of the MgO surface. In conclusion, this work implies that growth of candidate electrocatalyst materials by PLD in inert gas background may allow mesoporous frameworks with a single crystallographic orientation that expose specific crystal facets for electrochemical reactions and active site engineering.

cluster epitaxy↗

Scalable ultrafast epitaxy of large-grain and single-crystal II-VI semiconductors

A general problem for semiconductor applications is that very slow deposition on expensive single-crystal substrates yields high crystalline quality with excellent electro-optical properties, but at prohibitive costs and throughput for many applications. In contrast, rapid deposition on inexpensive substrates or nanocrystalline films yields low costs, but comparatively inferior crystallinity, carrier transport, and recombination. Here, we present methods to deposit single-crystal material at rates 2-3 orders of magnitude faster than state-of-the-art epitaxy with low-cost methods without compromising crystalline or electro-optical quality. For example, single-crystal CdTe and CdZnTe films that would take several days to grow by molecular-beam epitaxy are deposited in 8 minutes by close-spaced sublimation, yet retain the same crystalline quality measured by X-ray diffraction rocking curves. The fast deposition is coupled with effective n- and p-type in-situ doping by In, P, and As. The epitaxy can be extended to nanocrystalline substrates. For example, we recrystallize thin CdTe films on glass to deposit large grains with low defect density. The results provide new research paths for photovoltaics, detectors, infrared imaging, flexible electronics, and other applications.

14 SOLAR ENERGY↗

Increased spatial coherence length from an asymmetric crystal reflection at grazing exit

Coherent X-ray imaging is an active field at synchrotron sources. The images rely on the available coherent flux over a limited field of view. At many synchrotron beamlines a double-crystal monochromator (DCM) is employed in a standard nondispersive arrangement. For coherent diffraction imaging it is advantageous to increase the available field of view by increasing the spatial coherence length (SCL) of a beam exiting such a DCM. Here, Talbot interferometry data together with ray-tracing simulations for a (+ − − +) four-reflection experimental arrangement are presented, wherein the first two reflections are in the DCM and the final fourth reflection is asymmetric at grazing exit. Analyses of the interferometry data combined with the simulations show that compared with the beam exiting the DCM a gain of 76% in the SCL was achieved, albeit with a factor of 20 reduction in flux density, which may not be a severe penalty at a synchrotron beamline. Previous efforts reported in the literature to increase the SCL that employed asymmetric crystal diffraction at grazing incidence are also discussed. A much reduced SCL is found presently in simulations wherein the same asymmetric crystal is set for grazing incidence instead of grazing exit. In addition, the present study is compared and contrasted with two other means of increasing the SCL. These are (i) focusing the beam onto an aperture to act as a secondary source, and (ii) allowing the beam to propagate in vacuum an additional distance along the beamline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hints of Growth Mechanism Left in Supercrystals

Supercrystals of DNA-functionalized nanoparticles arevisualizedin three dimensions using X-ray ptychographic tomography, and theirreciprocal spaces are mapped with small-angle X-ray scattering inorder to better understand their internal defect structures. X-rayptychographic tomography reveals various types of defects in an assemblythat otherwise exhibits a single crystalline diffraction pattern.On average, supercrystals composed of smaller nanoparticles are smallerin size than supercrystals composed of larger particles. Additionally,supercrystals composed of small nanoparticles are typically aggregatedinto larger "necklace-like" structures. Within theselarger structures, some but not all pairs of connected domains arecoherent in their relative orientations. In contrast, supercrystalscomposed of larger nanoparticles with longer DNA ligands typicallyform faceted crystals. The combination of these two complementaryX-ray techniques reveals that the crystalline assemblies grow by aggregationof smaller assemblies followed by rearrangement of nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase retrieval for refraction-enhanced x-ray radiography using a deep neural network

X-ray refraction-enhanced radiography (RER) or phase contrast imaging is widely used to study internal discontinuities within materials. The resulting radiograph captures both the decrease in intensity caused by material absorption along the x-ray path, as well as the phase shift, which is highly sensitive to gradients in density. A significant challenge lies in effectively analyzing the radiographs to decouple the intensity and phase information and accurately ascertain the density profile. Conventional algorithms often yield ambiguous and unrealistic results due to difficulties in including physical constraints and other relevant information. We have developed an algorithm that uses a deep neural network to address these issues and applied it to extract the detailed density profile from an experimental RER. To generalize the applicability of our algorithm, we have developed a technique that quantitatively evaluates the complexity of the phase retrieval process based on the characteristics of the sample and the configuration of the experiment. Accordingly, this evaluation aids in the selection of the neural network architecture for each specific case. Beyond RER, the model has potential applications for other diagnostics where phase retrieval analysis is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SCExAO/MEC and CHARIS Discovery of a Low-mass, 6 au Separation Companion to HIP 109427 Using Stochastic Speckle Discrimination and High-contrast Spectroscopy

We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the Microwave Kinetic Inductance Detector Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star point spread function (PSF) subtraction yield 1.1–2.4 μm spectra. MEC reveals the companion in Y and J band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up L {sub p} photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4–M5.5, 3000–3200 K, and log{sub 10}(L/L{sub ⊙})=−2.28{sub −0.04}{sup +0.04}, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia–Hipparcos absolute astrometry of the primary favor a semimajor axis of 6.55{sup +3.0} {sub −0.48} au, an eccentricity of 0.54{sub −0.15}{sup +0.28}, an inclination of 66.7{sub −14}{sup +8.5} degrees, and a dynamical mass of 0.280{sub −0.059}{sup +0.18} M {sub ⊙}. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely used postprocessing methods to directly image faint companions to nearby stars near the telescope diffraction limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3013 Baseline Inner Container Report: Description, Imaging, and Analysis

This report presents consolidated findings from three microscopy studies of baseline Bagless Transfer Containers (BTCs), which are the inner containers used in DOE Standard 3013-compliant plutonium storage packages. The studies were conducted by Los Alamos National Laboratory (LANL), Savannah River National Laboratory (SRNL), and DNV, a subcontractor specializing in corrosion science. The baseline BTCs examined had not been exposed to corrosive environments, serving as control samples for comparison with destructively examined (DE) containers. Additionally, the Background section provides an overview of the BTC design, including manufacturing methods, material properties, and container configurations that may influence corrosion behavior. The primary objective of the LANL and SRNL studies was to establish reference characteristics of BTCs to distinguish manufacturing artifacts from corrosion-induced features observed in DE containers. Both laboratories used advanced microscopy techniques, including Wide Area Microscopy (WAMS), Laser Confocal Microscopy (LCM), Scanning Electron Microscopy (SEM), and Focused Ion Beam (FIB), to reveal that most surface anomalies were shallow and attributable to flow-forming processes, not corrosion. Subsurface impurities, identified as non-metallic inclusions, were also observed. DNV’s investigation focused on characterizing the mechanical and chemical properties of the BTC material to support crack growth modeling. Their findings indicate higher hardness and strength but reduced ductility—consistent with flow-formed 304L stainless steel and a higher-than-expected martensite content, in contrast to manufacturer claims. Ongoing and future studies, including Electron Backscatter Diffraction (EBSD), aim to further understand the microstructural factors influencing crack initiation and propagation. The combined studies provide a crucial baseline for distinguishing corrosion effects in DE containers, contributing to the safe and reliable long-term storage of plutonium-bearing materials.

36 MATERIALS SCIENCE↗

A high-pressure flow through test vessel for neutron imaging and neutron diffraction-based strain measurement of geological materials

Neutron scattering and neutron imaging have emerged as powerful methods for experimentally investigating material deformation and fluid flow in the interior of otherwise inaccessible or opaque structures. This paper describes the design and provides example uses of a pressure cell developed for investigating such behaviors within geological materials. The cell can accommodate cylindrical samples with diameters up to 38.1 mm and lengths up to 154 mm. Additionally, ports in the cell and a pressure isolating sleeve around the sample allow the independent application of confining pressure up to 69 MPa and axial pressure up to 34.5 MPa. Furthermore, two material versions of the cell have been manufactured and used to date. An aluminum version is typically used for temperatures below 40 °C, because of its relative transparency to neutrons, while a titanium version, which is comparatively more neutron attenuating, is used for experiments requiring triaxial pressurization under conditions up to 350 °C. The pressure cells were commissioned at the VULCAN engineering diffractometer at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source, and have since been used at the ORNL high flux isotope reactor CG1-D imaging beamline, National Institute of Standard and Technology (NIST) BT-2, and NIST NG6 imaging beamlines.

47 OTHER INSTRUMENTATION↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗