Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “differential sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effect of Temperature on Thrombogenicity Testing of Biomaterials in an In Vitro Dynamic Flow Loop System

To develop and standardize a reliable in vitro dynamic thrombogenicity test protocol, the key test parameters that could impact thrombus formation need to be investigated and understood. In this study, we evaluated the effect of temperature on the thrombogenic responses (thrombus surface coverage, thrombus weight, and platelet count reduction) of various materials using an in vitro blood flow loop test system. Whole blood from live sheep and cow donors was used to assess four materials with varying thrombogenic potentials: negative-control polytetrafluoroethylene (PTFE), positive-control latex, silicone, and high-density polyethylene (HDPE). Blood, heparinized to a donor-specific concentration, was recirculated through a polyvinyl chloride tubing loop containing the test material at room temperature (22–24°C) for 1 hour, or at 37°C for 1 or 2 hours. The flow loop system could effectively differentiate a thrombogenic material (latex) from the other materials for both test temperatures and blood species ( p < 0.05). However, compared with 37°C, testing at room temperature appeared to have slightly better sensitivity in differentiating silicone (intermediate thrombogenic potential) from the relatively thromboresistant materials (PTFE and HDPE, p < 0.05). These data suggest that testing at room temperature may be a viable option for dynamic thrombogenicity assessment of biomaterials and medical devices.

Engineering↗

An ultraviolet light induced bacteriophage in Beneckea gazogenes

The effects of UV and high intensity irradiation on microorganisms growing under conditions prevalent during the early Precambrian Aeon are examined. The study employed the anaerobic red pigmented marine vibrio, Beneckea gazogenes (Harwood, 1978), using an extreme UV sensitivity of 2537 A, extensive cell lysis, and commitant production of bacteriophage induced by the UV light. Three types of white mutant, pink colony mutant, and red wild type isolates of B gazogenes were grown showing differential irradiation sensitivity and phage particles from all three lysates were collected and examined.

Rambler, M.↗

Ionic Peltier effect in Li-ion electrolytes

The coupled transport of charge and heat provide fundamental insights into the microscopic thermodynamics and kinetics of materials. We describe a sensitive ac differential resistance bridge that enables measurements of the temperature difference on two sides of a coin cell with a resolution of better than 10 μK. We use this temperature difference metrology to determine the ionic Peltier coefficients of symmetric Li-ion electrochemical cells as a function of Li salt concentration, solvent composition, electrode material, and temperature. The Peltier coefficients Π are negative, i.e., heat flows in the direction opposite to the drift of Li ions in the applied electric field, large, –Π > 30 kJ mol –1 , and increase with increasing temperature at T > 300 K. The Peltier coefficient is approximately constant on time scales that span the characteristic time for mass diffusion across the thickness of the electrolyte, suggesting that heat of transport plays a minor role in comparison to the changes in partial molar entropy of Li at the interface between the electrode and electrolyte. Here, our work demonstrates a new platform for studying the non-equilibrium thermodynamics of electrochemical cells and provides a window into the transport properties of electrochemical materials through measurements of temperature differences and heat currents that complement traditional measurements of voltages and charge currents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗

A generalist–specialist trade-off between switchgrass cytotypes impacts climate adaptation and geographic range

Polyploidy results from whole-genome duplication and is a unique form of heritable variation with pronounced evolutionary implications. Different ploidy levels, or cytotypes, can exist within a single species, and such systems provide an opportunity to assess how ploidy variation alters phenotypic novelty, adaptability, and fitness, which can, in turn, drive the development of unique ecological niches that promote the coexistence of multiple cytotypes. Switchgrass, Panicum virgatum, is a widespread, perennial C4 grass in North America with multiple naturally occurring cytotypes, primarily tetraploids (4×) and octoploids (8×). Using a combination of genomic, quantitative genetic, landscape, and niche modeling approaches, we detect divergent levels of genetic admixture, evidence of niche differentiation, and differential environmental sensitivity between switchgrass cytotypes. Taken together, these findings support a generalist (8×)–specialist (4×) trade-off. Our results indicate that the 8× represent a unique combination of genetic variation that has allowed the expansion of switchgrass’ ecological niche and thus putatively represents a valuable breeding resource.

09 BIOMASS FUELS↗

QTL × environment interactions underlie ionome divergence in switchgrass

Abstract Ionomics measures elemental concentrations in biological organisms and provides a snapshot of physiology under different conditions. In this study, we evaluate genetic variation of the ionome in outbred, perennial switchgrass in three environments across the species’ native range, and explore patterns of genotype-by-environment interactions. We grew 725 clonally replicated genotypes of a large full sib family from a four-way linkage mapping population, created from deeply diverged upland and lowland switchgrass ecotypes, at three common gardens. Concentrations of 18 mineral elements were determined in whole post-anthesis tillers using ion coupled plasma mass spectrometry (ICP-MS). These measurements were used to identify quantitative trait loci (QTL) with and without QTL-by-environment interactions (QTLxE) using a multi-environment QTL mapping approach. We found that element concentrations varied significantly both within and between switchgrass ecotypes, and GxE was present at both the trait and QTL level. Concentrations of 14 of the 18 elements were under some genetic control, and 77 QTL were detected for these elements. Seventy-four percent of QTL colocalized multiple elements, half of QTL exhibited significant QTLxE, and roughly equal numbers of QTL had significant differences in magnitude and sign of their effects across environments. The switchgrass ionome is under moderate genetic control and by loci with highly variable effects across environments.

59 BASIC BIOLOGICAL SCIENCES↗

CONCURRENT, CONDENSED STEIN VARIATIONAL GRADIENT DESCENT FOR UNCERTAINTY QUANTIFICATION OF NEURAL NETWORKS

In this work, we propose a Stein variational gradient descent (SVGD) method to concurrently sparsify, train, and provide uncertainty quantification (UQ) of a complexly parameterized model, such as a neural network (NN). It employs a graph reconciliation and condensation process to reduce complexity and increase similarity in the Stein ensemble of parameterizations. Therefore, the proposed concurrent, condensed SVGD (ccSVGD) method can provide UQ on parameters, not just outputs. Furthermore, the parameter reduction speeds up the convergence of the Stein gradient descent as it reduces the combinatorial complexity by aligning and differentiating the sensitivity to parameters. These properties are demonstrated with an illustrative example and an application to a mechanical response representation problem in solid mechanics.

42 ENGINEERING↗

Pyrotechnic hazards classification and evaluation program. Phase 3, segments 1-4: Investigation of sensitivity test methods and procedures for pyrotechnic hazards evaluation and classification, part A

The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.

Source record↗

Digital halftoning methods for selectively partitioning error into achromatic and chromatic channels

A method is described for reducing the visibility of artifacts arising in the display of quantized color images on CRT displays. The method is based on the differential spatial sensitivity of the human visual system to chromatic and achromatic modulations. Because the visual system has the highest spatial and temporal acuity for the luminance component of an image, a technique which will reduce luminance artifacts at the expense of introducing high-frequency chromatic errors is sought. A method based on controlling the correlations between the quantization errors in the individual phosphor images is explored. The luminance component is greatest when the phosphor errors are positively correlated, and is minimized when the phosphor errors are negatively correlated. The greatest effect of the correlation is obtained when the intensity quantization step sizes of the individual phosphors have equal luminances. For the ordered dither algorithm, a version of the method can be implemented by simply inverting the matrix of thresholds for one of the color components.

Mulligan, Jeffrey B.↗

Sensitivity of a GCM climate simulation to differences in continental versus maritime cloud drop size

Extensive observations indicate a distinct difference between maritime and continental effective drop size, r(sub e), for warm clouds. The latest version of the National Center for Atmospheric Research (NCAR) Community Climate Model (CCM2) is used to explore the sensitivity of differentiating between continental and maritime r(sub e) on the simulated climate. The results of this study indicate that the smaller drop size over continents leads to a reduction of surface-absorbed solar radiation from 20 to 60 W/sq m. This reduction in surface solar flux leads to a cooling of the continents by up to -3.5 K. The reduction in surface solar flux and temperature also leads to a reduction in latent heat flux and precipitation over land. In the January simulation, there is a significant shift in tropical precipitation associated with the Australian monsoon. This shift leads to a response in the extra tropical geopotential height field over the western United States. All of these changes reduce biases in the current version of CCM2.

Kiehl, J. T.↗

Resolved resonance region evaluations of n+ 206,207,208 Pb for fast spectrum applications

Resolved resonance region evaluations of the major isotopes of natural lead, 206 Pb, 207 Pb, 208 Pb, have been per formed to support the development of Generation IV reactors. In this study, validation of nuclear data for lead fast reactors was performed with simulations of shielding benchmarks, integral critical benchmarks, and quasi-differential scattering measurements. Sensitivity analyses of these systems showed that elastic scattering reactions above 100 keV were the dominant reactions driving system performance. The resolved resonance regions (RRRs) of the lead isotopes extend past 100 keV, making the RRR an ideal starting point to evaluate lead cross sections. Since the R-matrix requires knowledge of bound, distant, and observed resonances, it was necessary to evaluate from 10 -5 eV up to the respective limit of the RRR. The 208 Pb RRR evaluation was extended to 1.5 MeV in order to obtain resonance parameters used to calculate new elastic scattering angular distributions up to 1.5 MeV. Resonance parameter uncertainties and covariance were generated using the R-matrix code SAMMY. The new RRR parameters show a direct improvement to the scattering kernel below 1.5 MeV which in turn greatly improves fast critical experiments over ENDF/B-VIII.0.

206Pb↗

Variability in Galactic Cosmic Radiation- Induced DNA Damage Response in Inbred Mice Is Modulated by Genetics

In radiation biology, the ability to predict cancer risk associated with exposure to low doses of high-LET (Linear Energy Transfer) ionizing radiation remains a challenge. Epidemiological methods lack the sensitivity and power to provide detailed risk estimates for cancer and ignore individual sensitivity. We have hypothesized that DNA repair capacity is the primary factor differentiating peoples radiation sensitivity. We previously showed in immortalized human cell lines that characterizing the dose and time dependence of p53-binding protein 1 (53BP1) foci formation in the nucleus following X-rays exposure is sufficient to predict DNA repair response to any other LET in the same cell line. We now tested this hypothesis across a population of mice with different genetic background. Fibroblast cells were extracted and cultivated from 76 individual mice from 15 different strains and exposed to HZE (high (H) atomic number (Z) and energy (E) galactic cosmic ray particles) particles and X-rays. Individual radiation sensitivities were investigated by high throughput measurement of DNA repair kinetics that evaluated 53bp1 foci numbers as a surrogate for DNA double-strand breaks at various times post-irradiation. Instead of just counting foci which can be hard to distinguish for high-LET or high doses, we also took into account the track structure of high-LET particles to compute the remaining number of unrepaired tracks as a function of time post-irradiation. As expected, the percentage of unrepaired track over a 48 hours follow-up period increased with LET. In addition, repair rate was modulated by genetics, with animals from the same strain showing small variance while large rate differences were observed between strains. Radiation strain sensitivity ranking was estimated based on repair rates from exposure to each LET evaluated in this work, and ranking for high-LET correlated better with ranking from high dose of X-ray, not low dose. At the in-vivo level, drops in T-cells and B-cells number measured 24 hours after 0.1 Gy (Gray) X-ray exposure, correlated with slower DNA repair kinetic in fibroblast cells of the same strains of mice. At the genomic level, mouse genome wide association (GWA) analysis identified seven significant genetic loci on chromosomes 2, 3, 7, 10, 11, 13 and 19 with different significance depending on the LET. Interestingly, for the two highest LET, a common locus on Chromosome 10 was identified with high enrichment for DNA repair associated genes.Overall, this work suggests that repair kinetics of primary skin fibroblasts is a good surrogate marker for in-vivo radiation sensitivities in other tissues and that this response is modulated by genetics. Our study also confirms that DNA repair kinetics following high doses of X-ray can be used to predict radiation sensitivity to high-LET.

High-LET Radiation↗

Evaluation of Methods for Molecular Dynamics Simulation of Ionic Liquid Electric Double Layers

We investigate how systematically increasing the accuracy of various molecular dynamics modeling techniques influences the structure and capacitance of ionic liquid electric double layers (EDLs). The techniques probed concern long-range electrostatic interactions, electrode charging (constant charge versus constant potential conditions), and electrolyte polarizability. Our simulations are performed on a quasi-two-dimensional, or slab-like, model capacitor, which is composed of a polarizable ionic liquid electrolyte, [EMIM][BF4], interfaced between two graphite electrodes. To ensure an accurate representation of EDL differential capacitance, we derive new fluctuation formulas that resolve the differential capacitance as a function of electrode charge or electrode potential. The magnitude of differential capacitance shows sensitivity to different long-range electrostatic summation techniques, while the shape of differential capacitance is affected by charging technique and the polarizability of the electrolyte. For long-range summation techniques, errors in magnitude can be mitigated by employing two-dimensional or corrected three dimensional electrostatic summations, which lead to electric fields that conform to those of a classical electrostatic parallel plate capacitor. With respect to charging, the changes in shape are a result of ions in the Stern layer (i.e. ions at the electrode surface) having a higher electrostatic affinity to constant potential electrodes than to constant charge electrodes. For electrolyte polarizability, shape changes originate from induced dipoles that soften the interaction of Stern layer ions with the electrode. The softening is traced to ion correlations vertical to the electrode surface that induce dipoles that oppose double layer formation. In general, our analysis indicates an accuracy dependent differential capacitance profile that transitions from the characteristic camel shape with coarser representations to a more diffuse profile with finer representations.

Haskins, Justin B.↗

(U) Using the MCNP6 Perturbation Capability for Source Nuclide Density Sensitivities

The Taylor series (differential operator) perturbation method, as implemented in the PERT capability in MCNP6 (Ref. 1), can be used for first- and second-order sensitivity analyses in fixed-source problems. Unfortunately, the PERT capability does not yet work with point-detector (F5) or pulse-height (F8) tallies. Also, the second-order Taylor series term lacks the cross terms that would allow the calculation of mixed sensitivities. Finally, the PERT capability does not compute any sensitivities involving the source in a fixed-source problem. When neutrons or gamma rays are emitted due to radioactive decay, the source rate density depends intrinsically on the nuclide densities in the source material. When the PERT capability in MCNP6 is used to compute sensitivities of a response to nuclide and material densities, those sensitivities do not include the effect of the source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting Cancer Risk from Ionizing Radiation

The ability to predict cancer risk associated with exposure to low doses of high-LET ionizing radiation (IR) remains a challenge. Epidemiological methods lack the sensitivity and power to provide detailed risk estimates for cancer and ignore individual variance in IR sensitivity. We have hypothesized that DNA repair capacity can be used as a marker to evaluate and differentiate individual radiation sensitivity. More specifically, this work is based on the concept that the combined time-dose dependence of radiation-induced foci (RIF) of p53-binding protein 1 (53BP1) following low-LET exposure contains sufficient information to infer sensitivity to any other LET. Our hypothesis was tested in 15 different mouse strains as well as in primary human immune cells. We first approached individual ionizing radiation sensitivity in a mouse model by culturing primary skin fibroblasts extracted from 76 mice of 15 different genetic backgrounds and exposing them to HZE particles and X-rays. This work is one of the most extensive studies on the kinetics and possible genetic underpinnings of radiation-induced DNA damage and repair. Our results is in agreement with a DNA repair model we previously postulated, where nearby DNA double strand breaks (DSB) in the nucleus are brought together for more efficient repair, leading to RIF clustering. Such mechanism was evidenced by a specific dose and LET dependence of RIF numbers. Briefly, RIF quantification after low-LET X-ray exposure showed an asymptotic saturation for doses between 1 Gy and 4 Gy 4 hours post-irradiation across all 15 strains. The clustering of DSB across all strains also led to more RIF/Gy for lower LET (X-ray and 350 MeV/n Ar) than for higher LET (600 MeV/n Fe) 4 hours post-exposure. Considering the fact that the number of DSB/Gy should be independent of LET, our data suggest there are more DSB in individual RIF as the LET increases. RIF numbers for 24 and 48 hours post-exposure led to the inverse trend, with more remaining RIF/Gy for higher LET (by 600 MeV/n Fe). This result suggests cells have more difficulty resolving RIF from higher LET as they the number DSB/RIF increases. Note that for most conditions, the variance of RIF/Gy was small within individual animals of the same strain and large between strains, suggesting a strong genetics component. Furthermore, we present our preliminary data from an ongoing study on human genetic associations with IR sensitivity. To address the human variability in responses to HZE particle irradiation in a maximally comprehensive manner, we are in the process of collecting and isolating primary blood mononuclear cells from 768 healthy subjects of European descent, 18-75 years of age, 50/50 male/female distribution. We have analyzed 53BP1+ RIF formation as well as oxidative stress and cell death in primary cells from 192 subjects in response to the same HZE particles as used in mice: 600 MeV/n Fe, 350 MeV/n Ar and 350 MeV/n Si, 1.1 and 3 particles/100m2, 4 and 24 hours after irradiation. We will next complete the quantification of HZE particle-induced DNA and cellular damage in the remaining subjects and compare it to their responses to low-LET irradiation. Finally, we will perform GWAS analysis to identify human genomic associations with IR sensitivity and potential targets for biomarker development.

High-LET radiation↗

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗