Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

New Physics Search in Dijet Mass Spectrum with Compact Muon Solenoid

Many extensions of the SM predict the existence of new massive objects that couple to quarks and gluons and result in resonances in the dijet mass spectrum. In this thesis we present a search for narrow resonances in the dijet mass spectrum using data corresponding to an integrated luminosity of 1 fb$^{-1}$ collected by the CMS experiment at the LHC, at a proton-proton collision energy of $\sqrt{s}=7$ $TeV$. %This dijet analysis is searching for new particles in the dijet mass spectrum decaying to dijets. These new particles are predicted by new physics beyond Standard Model. This thesis presents a dijet analysis performed at the Compact Muon Solenoid (CMS) in pp collisions at $\sqrt{s}=7$ $TeV$ for an integrated luminosities of 1.0 fb$^{-1}$. The dijet mass distribution of two leading jets is measured and compared to QCD predictions, simulated by PYTHIA with the CMS detector simulation. We select events which have two leading jets with $\mid \Delta\eta \mid < 1.3$ and $\mid \eta \mid < 2.5$. We fit the dijet mass spectrum with QCD parameters. Since no evidence of new physics was found, we set upper limits at 95\% CL on the resonance cross section and compare to the theoretical prediction for several models of new particles: string resonances, axigluons, colorons, excited quarks, $E_{6}$ diquarks, Randall-Sundrum gravitons, W' and Z'. We exclude at 95\% CL string resonances in the mass range $1.0 < M(S) < 4.00$ TeV, excited quarks in the mass range $1.0<M(q*)<2.49$ TeV, axigluons and colorons in the mass range $1.0<M(A)<2.47$ TeV, $E_6$ diquarks in the mass range $1.0<M(D)<3.52$ TeV, and W' bosons in the mass range $1.0<M(W')<1.51$ TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast and accurate simulations of calorimeter showers with normalizing flows

In this study, we introduce caloflow, a fast detector simulation framework based on normalizing flows. For the first time, we demonstrate that normalizing flows can reproduce many-channel calorimeter showers with extremely high fidelity, providing a fresh alternative to computationally expensive geant4 simulations, as well as other state-of-the-art fast simulation frameworks based on generative adversarial networks (GANs) or variational autoencoders (VAEs). In addition to the usual histograms of physical features and images of calorimeter showers, we introduce a new metric for judging the quality of generative modeling: the performance of a classifier trained to differentiate real from generated images. We show that GAN-generated images can be identified by the classifier with nearly 100% accuracy, while images generated from caloflow are better able to fool the classifier. More broadly, normalizing flows offer several advantages compared to other state-of-the-art approaches (GANs and VAEs), including tractable likelihoods, stable and convergent training, and principled model selection. Normalizing flows also provide a bijective mapping between data and the latent space, which could have other applications beyond simulation, for example, to detector unfolding.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Elimination LArTPC Simulation Uncertainty With Modifcations to TPC Wire Waveforms

This paper introduces a novel approach to reducing systematic uncertainties in LArTPC detector simulations, which arise from known detector effects that are challenging and computationally intensive to model. The proposed method involves modifying simulated waveforms based on observed discrepancies in ionization signals from the TPC between actual data and simulations. This approach reduces the sensitivity to detailed detector modeling and decreases the computational resources required for accurate simulations.

Mktchyan, Karen↗

DUNE – Simulation Validation of Fermilab Detector Reconstruction

DUNE (Deep Underground Neutrino Experiment) is Fermilab’s flagship international experiment designed to study neutrinos by sending an intense beam from Illinois to detectors located 1,300 kilometers away at the Sanford Underground Research Facility (SURF) in South Dakota. To prepare for such a large-scale experiment, physicists develop detailed simulations to produce mock data sets which are analyzed by the CAFAna framework. During my internship, I developed software using the CAFAna framework to analyze simulated detector data and generated plots to make data trends easier to interpret and identify patterns. My analysis has uncovered inconsistencies in reconstructed neutrino tracks, duplicated reconstructed tracks causing sporadic spikes in the data, and unnatural differences in energy levels between interaction types. These analyses help verify that the improvements to detector simulations do not introduce unintended resolution errors and ensure proper reconstruction performance, supporting DUNE’s goal of making precise neutrino measurements and advancing the Department of Energy’s mission of fundamental scientific discovery.

Vershaw, Andre [Unlisted, US, IL; Fermilab] (ORCID↗

Celeritas: Accelerating Geant4 with GPUs

Celeritas [1] is a new Monte Carlo (MC) detector simulation code designed for computationally intensive applications (specifically, High Lumi- nosity Large Hadron Collider (HL-LHC) simulation) on high-performance heterogeneous architectures. In the past two years Celeritas has advanced from prototyping a GPU-based single physics model in infinite medium to implementing a full set of electromagnetic (EM) physics processes in complex geometries. The current release of Celeritas, version 0.3, has incorporated full device-based navigation, an event loop in the presence of magnetic fields, and detector hit scoring. New functionality incorporates a scheduler to offload electromagnetic physics to the GPU within a Geant4-driven simulation, enabling integration of Celeritas into high energy physics (HEP) experimental frameworks such as CMSSW. On the Summit supercomputer, Celeritas performs EM physics between 6 and 32 faster using the machine’s Nvidia GPUs compared to using only CPUs. When running a multithreaded Geant4 ATLAS test beam application with full hadronic physics, using Celeritas to accelerate the EM physics results in an overall simulation speedup of 1.8–2.3× on GPU and 1.2× on CPU.

Johnson, Seth R.↗

Upgrades for the CMS simulation

Over the past several years, the CMS experiment has made significant changes to its detector simulation application. The geometry has been generalized to include modifications being made to the CMS detector for 2015 operations, as well as model improvements to the simulation geometry of the current CMS detector and the implementation of a number of approved and possible future detector configurations. These include both completely new tracker and calorimetry systems. We have completed the transition to Geant4 version 10, we have made significant progress in reducing the CPU resources required to run our Geant4 simulation. These have been achieved through both technical improvements and through numerical techniques. Substantial speed improvements have been achieved without changing the physics validation benchmarks that the experiment uses to validate our simulation application for use in production. As a result, we will discuss the methods that we implemented and the corresponding demonstrated performance improvements deployed for our 2015 simulation application.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulating the Phonon Collection Efficiency in KIPMDs

Kinetic inductance phonon-mediated (KIPM) detectors use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the substrate. They are a promising class of detectors to be used in light dark matter (DM) searches due to their potential eV-scale sensitivity and native frequency-domain multiplexability. In order to improve upon the design of these detectors, simulations are needed to understand the effects of detector design on measurable physical parameters including the phonon collection efficiency, $\eta_{ph}$, which is defined as the ratio of phonon energy detected by the sensitive target element to the incident energy deposited in the substrate. This work simulates the phonon collection efficiency for a KIPMD currently operated at the Northwestern EXperimental Underground Site (NEXUS).

Dang, Stella Q.↗

A comprehensive simulation framework for imaging single particles and biomolecules at the European X-ray Free-Electron Laser

The advent of newer, brighter, and more coherent X-ray sources, such as X-ray Free-Electron Lasers (XFELs), represents a tremendous growth in the potential to apply coherent X-rays to determine the structure of materials from the micron-scale down to the Angstrom-scale. There is a significant need for a multi-physics simulation framework to perform source-to-detector simulations for a single particle imaging experiment, including (i) the multidimensional simulation of the X-ray source; (ii) simulation of the wave-optics propagation of the coherent XFEL beams; (iii) atomistic modelling of photon-material interactions; (iv) simulation of the time-dependent diffraction process, including incoherent scattering; (v) assembling noisy and incomplete diffraction intensities into a three-dimensional data set using the Expansion-Maximisation-Compression (EMC) algorithm and (vi) phase retrieval to obtain structural information. Furthermore, we demonstrate the framework by simulating a single-particle experiment for a nitrogenase iron protein using parameters of the SPB/SFX instrument of the European XFEL. This exercise demonstrably yields interpretable consequences for structure determination that are crucial yet currently unavailable for experiment design.

42 ENGINEERING↗

A statistically defined anthropomorphic software breast phantom

Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm){sup 3} voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise ({beta} = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 Multiplication-Sign 3 boxcar kernel and up-sampled to (0.1 mm){sup 3} voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent {beta} from 25.6 Multiplication-Sign 25.6 mm{sup 2} regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for {beta} (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. {beta} values for this new phantom are comparable with published values for breast tissue in x-ray projection modalities. The combination of conspicuous linear structures and binarized power-law noise added to a limited area of the phantom qualitatively improves its realism.

60 APPLIED LIFE SCIENCES↗

Muon Reconstruction and Identification in CMS

We present the design strategies and status of the CMS muon reconstruction and identification identification software. Muon reconstruction and identification is accomplished through a variety of complementary algorithms. The CMS muon reconstruction software is based on a Kalman filter technique and reconstructs muons in the standalone muon system, using information from all three types of muon detectors, and links the resulting muon tracks with tracks reconstructed in the silicon tracker. In addition, a muon identification algorithm has been developed which tries to identify muons with high efficiency while maintaining a low probability of misidentification. The muon identification algorithm is complementary by design to the muon reconstruction algorithm that starts track reconstruction in the muon detectors. The identification algorithm accepts reconstructed tracks from the inner tracker and attempts to quantify the muon compatibility for each track using associated calorimeter and muon detector hit information. The performance status is based on detailed detector simulations as well as initial studies using cosmic muon data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector requirements and simulation results for the EIC exclusive, diffractive and tagging physics program using the ECCE detector concept

This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC’s exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark–gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detector system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirm the proposed technology and design satisfy the requirements. Further, the projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb -1 of integrated luminosity. Additionally, insights related to a potential second EIC detector are documented, which could serve as a guidepost for future development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hybrid 3D/2D field response calculation for liquid argon detectors with PCB based anode plane

Liquid Argon Time Projection Chamber (LArTPC) technology is commonly utilized in neutrino detector designs. It enables detailed reconstruction of neutrino events with high spatial precision and low energy threshold. Its field response (FR) model describes the time-dependent electric currents induced in the anode-plane electrodes when ionization electrons drift nearby. An accurate and precise FR is a crucial input to LArTPC detector simulations and charge reconstruction. Established LArTPC designs have been based on parallel wire planes. It allows accurate and computationally economic two-dimensional (2D) FR models utilizing the translational symmetry along the direction of the wires. Recently, novel LArTPC designs utilize electrodes formed on printed circuit board (PCB) in the shape of strips with through holes. The translational symmetry is no longer a good approximation near the electrodes and a new FR calculation that employs regions with three dimensions (3D) has been developed. Extending the 2D models to 3D would be computationally expensive. Fortuitously, the nature of strips with through holes allows for a computationally economic approach based on the finite-difference method (FDM). In this paper, we present a new software package pochoir that calculates LArTPC field response for these new strip-based anode designs. This package combines 3D calculations in the volume near the electrodes with 2D far-field solutions to achieve fast and precise field response computation. We apply the resulting FR to simulate and reconstruct samples of cosmic-ray muons and 39 Ar decays from a Vertical Drift (VD) detector prototype operated at CERN. We find the difference between real and simulated data within 5%. Current state-of-the-art LArTPC software requires a 2D FR which we provide by averaging over one dimension and estimate that variations lost in this average are smaller than 7%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibrating Bayesian generative machine learning for Bayesiamplification

Recently, combinations of generative and Bayesian deep learning have been introduced in particle physics for both fast detector simulation and inference tasks. These neural networks aim to quantify the uncertainty on the generated distribution originating from limited training statistics. The interpretation of a distribution-wide uncertainty however remains ill-defined. We show a clear scheme for quantifying the calibration of Bayesian generative machine learning models. For a Continuous Normalizing Flow applied to a low-dimensional toy example, we evaluate the calibration of Bayesian uncertainties from either a mean-field Gaussian weight posterior, or Monte Carlo sampling network weights, to gauge their behaviour on unsteady distribution edges. Well calibrated uncertainties can then be used to roughly estimate the number of uncorrelated truth samples that are equivalent to the generated sample and clearly indicate data amplification for smooth features of the distribution.

97 MATHEMATICS AND COMPUTING↗

RadSim: Math, Utility & RTK

This package includes three parts, (1) gov.llnl.math, (2)gov.llnl.utility and (3)gov.llnl.rtk, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The techniques and implementation will be entirely transparent, which will allow for improvements and boutique modifications by future researchers beyond the lifespan of this specific project. The first tool of the package, gov.llnl.math, includes classes and functions to define and perform basic math operations. Some of the example features available in the package include defining statistical distributions and performing algebra and matrix operations, all of which are already accessible on publicly available software packages such as MATLAB and ROOT. The second package gov.llnl.utility includes tools commonly used to enable optimization and readability of various data structures such as Java lists and external xml files. Lastly, the gov.llnl.rtk package includes classes and functions to implement methods commonly used in radiation physics, such as data structures to represent and characterize photon spectra and tools to apply well-defined and published methods to calibrate a given spectra.

Cheung, Hoi Sing↗

RadSim: ENSDF, Xray and N42

This package includes three parts, (1) gov.bnl.nndc.ensdf, (2) gov.nist.xray and (3) gov.nist.physics.n42, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The first tool of the package, gov.bnl.nndc.ensdf, includes functionality to parse and split publicly available decay records in ENSDF format, and pull the relevant information from ENSDF libraries. The second tool, gov.nist.xray, provides Xray information using the public NIST database. Lastly, gov.nist.physics.n42, is a tool used to convert an N42 xml file into a Java object that can be interfaced within a Java program.

Hangal, DnaushA↗

A Toolkit to Study Sensitivity of the Geant4 Predictions to the Variations of the Physics Model Parameters

Geant4 is the leading detector simulation toolkit used in high energy physics to design detectors and to optimize calibration and reconstruction software. It employs a set of carefully validated physics models to simulate interactions of particles with matter across a wide range of interaction energies. These models, especially the hadronic ones, rely largely on directly measured cross-sections and phenomenological predictions with physically motivated parameters estimated by theoretical calculation or measurement. Because these models are tuned to cover a very wide range of possible simulation tasks, they may not always be optimized for a given process or a given material. This raises several critical questions, e.g. how sensitive Geant4 predictions are to the variations of the model parameters, or what uncertainties are associated with a particular tune of a Geant4 physics model, or a group of models, or how to consistently derive guidance for Geant4 model development and improvement from a wide range of available experimental data. We have designed and implemented a comprehensive, modular, user-friendly software toolkit to study and address such questions. It allows one to easily modify parameters of one or several Geant4 physics models involved in the simulation, and to perform collective analysis of multiple variants of the resulting physics observables of interest and comparison against a variety of corresponding experimental data. Based on modern event-processing infrastructure software, the toolkit offers a variety of attractive features, e.g. flexible run-time configurable workflow, comprehensive bookkeeping, easy to expand collection of analytical components. Design, implementation technology, and key functionalities of the toolkit are presented and illustrated with results obtained with Geant4 key hadronic models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Examining ICARUS Cosmic Muon Signal Shapes

In the search for new physics, such as sterile neutrinos, we must compare our experimental data to the case where this new physics does not exist, which is provided by simulations. However, our detectors and simulations are not perfect, so we need to be able to differentiate imperfections in our simulations, detector effects, and unknown unknowns from new physics. Thus, we need to quantify ICARUS detector systematic uncertainties; in other words, we need to know how much difference between experiment and simulation we can expect due to only detector systematics, so when we see differences greater than this, we can be confident they are due to new physics. To calculate this uncertainty, we study the signals produced in ICARUS by cosmic muons, since these muons are well understood. Ideally, we want to fit these waveforms as Gaussians and compare the fits from experimental data to fits from simulations to calculate the uncertainties, but first, we need to know how accurately these curve s can be described by Gaussians. We examined the peak and the full width at half maximum (FHWM) of signals from simulations, and we produced plots of the distribution of peaks and FHWMs for these signals. We further studied how the peaks and FHWMs varied depending on where the signal came from in the detector. Ultimately, by comparing the actual distribution of peaks and FHWMs to the distribution predicted by the Gaussian fits, we hope to determine how well these signals can be described as Gaussians.

Patino, Nicolas↗

Maximum Likelihood Estimation of the Broken Power Law Spectral Parameters with Detector Design Applications

The method of Maximum Likelihood (ML) is used to estimate the spectral parameters of an assumed broken power law energy spectrum from simulated detector responses. This methodology, which requires the complete specificity of all cosmic-ray detector design parameters, is shown to provide approximately unbiased, minimum variance, and normally distributed spectra information for events detected by an instrument having a wide range of commonly used detector response functions. The ML procedure, coupled with the simulated performance of a proposed space-based detector and its planned life cycle, has proved to be of significant value in the design phase of a new science instrument. The procedure helped make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope. This ML methodology is then generalized to estimate broken power law spectral parameters from real cosmic-ray data sets.

Howell, Leonard W.↗