Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “design and dispatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A comparison of price-taker and production cost models for determining system value, revenue, and scheduling of concentrating solar power plants

Concentrating solar power (CSP) plants convert solar energy into electricity and can be coupled with low-cost thermal energy storage to provide a dispatchable renewable resource. Maximizing the economic benefits of CSP systems requires deliberate selection of the timing of thermal energy dispatch to coincide with high-price or high-value periods. The performance and value of CSP systems have traditionally been evaluated using two distinct approaches: (1) production cost models (PCMs), which optimize commitment and dispatch schedules for an entire fleet of generators to minimize the cost of satisfying electricity demand; and (2) price-taker (PT) models, which optimize dispatch of the CSP system against historical or forecasted electricity prices to maximize revenue available to the CSP operator. The PCM approach is, in principle, superior because of the ability to capture system-level details such as transmission pathways and associated constraints, and feedback between CSP dispatch schedules and operation of other generators. The computationally simpler PT technique cannot explicitly address these concerns, but the comparative reduction in solution time is attractive for sensitivity analysis and rigorous optimization of CSP plant design and operation. In this work, we directly compare the dispatch profiles, net revenue, and operational value of CSP systems using implementations of each technique to assess how closely the solutions from the PT technique can approach those from the PCM for a specific market scenario. The PT implementation produced characteristically similar dispatch profiles as the PCM for both a large solar-multiple configuration and a small solar-multiple peaking configuration, while requiring only 1% of the computational time of the PCM. In addition, dispatching the CSP plant according to the self-scheduled PT solution - as opposed to the system-optimized PCM solution - only reduced the total CSP operational value by 1-5%, with consistent trends across CSP configurations and locations. This analysis validates the ability of the PT approach to substantially capture the economic benefits of CSP systems when pricing profiles are available, and indicates that the PT approach is suitable for initial design and optimization of CSP technologies.

14 SOLAR ENERGY↗

Optimal Strategies for Hybrid Battery‐Storage Systems Design

As stationary hybrid energy‐storage systems (HESS) for power systems applications have recently drawn interest due to their enhanced performance and decreasing cost, developing systematic approaches for HESS design while considering controls is gaining traction. Herein, a method is presented to optimally design hybrid battery storage by proposing a mathematical modeling framework, formulated as a mixed integer linear programming model. The optimization is capable of handling multiple subsystems of batteries, considering their economic and technological performance. Decisions involve sizing of the batteries, optimal temporal and strategic dispatch to end uses, and energy sources for charging each battery. The applicability of the model is tested on four case studies for three battery chemistries representing distinct objectives: high‐power, high‐energy, and second life. Compared to traditionally designed battery storage with a homogeneous battery, optimally designed hybrid systems can save 12%–26% of system costs, depending on the nature of the dispatch profile. Findings point to design preference toward the second life battery supplemented with some high‐power or high‐energy battery capacity, or both. With the utilized electricity price structure, customers can experience approximately 10%–35% reduction in their bills.

Koleva, Mariya↗

Dispatch optimization of electric thermal energy storage within System Advisor Model

A stand-alone electric thermal energy storage (ETES) system converts low-value electricity into heat using resistance heating elements. During periods of high-value electricity, an ETES system uses a thermodynamic power cycle to convert stored thermal energy back to electricity. These dispatchable systems derive value from their ability to store energy when prices are low and generate electricity when prices are favorable, i.e., energy arbitrage. Consequently, dispatch optimization of system operations, through maximizing revenue subject to system constraints, is essential to evaluate the economic value of a particular system design. While stand-alone ETES systems offer potential advantages as dispatchable grid storage technologies, there is a lack of a neutral third-party, publicly available, open-source model to evaluate the performance, dispatch, and financial viability of these systems. To address this problem, we have developed a techno-economic model for stand-alone ETES systems, within National Renewable Energy Laboratory's (NREL's) System Advisor Model (SAM). We implement a mixed-integer linear program to determine an ETES optimal operating schedule that maximizes electricity sales less maintenance costs caused by operation and cycling given temporal-varying grid electricity prices. Our contributions include a mixed-integer linear program for energy arbitrage of an ETES system, an ETES performance model through a publicly-available software (i.e., SAM), and an exercise of our model through case studies that compare ETES operational strategies and annual financial metrics. With our dispatch optimization model, we were able to improve revenue by 20% compared to a myopic heuristic while reducing the operational cost of the ETES system through decreases in cycle starts, cycles per day, and heater starts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Dispatch Strategies and Forecast Errors on the Economics of Behind-the-Meter PV-Battery Systems

To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncer- tainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.

batteries↗

Impacts of Dispatch Strategies and Forecast Errors on the Economics of Behind-the-Meter PV-Battery Systems

To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncertainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.

batteries↗

Impacts of Dispatch Strategies and Forecast Errors on the Economics of Behind-the-Meter PV-Battery Systems: Preprint

To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncertainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.

batteries↗

Technical assistance for law-enforcement communications: Case study report two

Two case histories are presented. In one study the feasibility of consolidating dispatch center operations for small agencies is considered. System load measurements were taken and queueing analysis applied to determine numbers of personnel required for each separate agency and for a consolidated dispatch center. Functional requirements were developed and a cost model was designed to compare relative costs of various alternatives including continuation of the present system, consolidation of a manual system, and consolidated computer-aided dispatching. The second case history deals with the consideration of a multi-regional, intrastate radio frequency for improved interregional communications. Sample standards and specifications for radio equipment are provided.

Reilly, N. B.↗

Urban Air Mobility Fleet Manager Gap Analysis and System Design

NASA's Urban Air Mobility (UAM) Sub-Project is engaged in research to support the introduction of air taxis into the National Airspace System. Such operations will require a range of communication, navigation, and surveillance systems. Air vehicles for UAM are under development and will initially have human pilots. Separation from other aircraft, obstacles, and weather may be a pilot responsibility or provided by an operator's ground-based systems. Eventually, air taxis may be flown from the ground or fly autonomously. There will be a need for dispatch services for UAM. This report presents a gap analysis, data and capability requirements, and workstation design concepts for the UAM dispatcher or Fleet Manager (FM) position.

Mogford, Richard↗

Fault-tolerant software for the FIMP

The work reported here provides protection against software failures in the task dispatcher of the FTMP, a particularly critical portion of the system software. Faults in other system modules and application programs can be handled by similar techniques but are not covered in this effort. Goals of the work reported here are: (1) to develop provisions in the software design that will detect and mitigate software failures in the dispatcher portion of the FTMP Executive and, (2) to propose the implementation of specific software reliability measures in other parts of the system. Beyond the specific support to the FTMP project, the work reported here represents a considerable advance in the practical application of the recovery block methodology for fault tolerant software design.

Hecht, H.↗

Market-Integrated Optimization of Wind-Battery-Hydrogen Hybrids for Peaking Capacity via Storage

As Integrated Energy Systems (IES) combine multiple energy and storage technologies to provide potentially more value and less risk via resource diversification, complementary overbuild, increased flexibility, and revenue-stacking, IES value is dependent on electricity market dispatch and grid interactions should play an important role in IES design and operation. This study hybridizes and retrofits wind and combustion turbine plants to study the impacts of replacing gas generation capacity with wind, battery, PEM electrolysis, hydrogen tanks and hydrogen turbines. The optimized design is co-simulated in a production cost model with different bidding strategies in order to compare performance and highlight the importance of grid-interactions. We analyze the revenue and dispatch changes as well as the price and cost implications of wind-battery-hydrogen IESs.

electrolysis↗

A land mobile satellite data system

The Telesat Mobile Incorporated (TMI) Mobile Data System (MDS) was developed to apply satellite technology to the transportation industry's requirement for a fleet management system. It will provide two-way messaging and automatic position reporting capabilities between dispatch centers and customers' fleets of trucks. The design was based on the Inmarsat L-Band space segment with system link parameters and margins adjusted to meet the land mobile satellite channel characteristics. The system interfaces with the Teleglobe Des Laurentides earth station at Weir, Quebec. The signaling protocols were derived from the Inmarsat Standard C packet signalling system with unique trucking requirements incorporated where necessary.

Kent, John D. B.↗

Developing a General Framework for Human Autonomy Teaming

Automation has entered nearly every aspect of our lives, but it often remains hard to understand. Why is this? Automation is often brittle, requiring constant human oversight to assure it operates as intended. This oversight has become harder as automation has become more complicated. To resolve this problem, Human-Autonomy Teaming (HAT) has been proposed. HAT looks to make automation act as more of a teammate, by having it communicate with human operators in a more human, goal-directed, manner which provides transparency into the reasoning behind automated recommendations and actions. This, in turn, permits more trust in the automation when it is appropriate, and less when it is not, allowing a more targeted supervision of automated functions. This paper proposes a framework for HAT, incorporating two key tenets: bi-directional communication, and operator directed authority. We have successfully applied these tenets to integrating the autonomous constrained flight planner (an aide for planning diverts) into a dispatch station. We propose the development of general design patterns that may allow these results to be generalized to domains such as photography and automotive navigation. While these domains are very different, we find application of our HAT tenets provides a number of opportunities for improving interaction between human operators and automation.

human factors↗

Significance of Dynamic and Transient Analysis in the Design and Operation of Hybrid Energy Systems

Energy systems were historically designed and operated with a specific energy conversion objective, while managing loads and resources. In the recent years, the increased utilization of non-dispatchable renewable sources such as wind and solar has played a role in power quality and the reliability of power systems. In order to mitigate the risk associated with the non-dispatchable resources an integrated approach, such as Hybrid Energy Systems (HES), has to be taken, integrating the loads and resource management between the traditional thermal power plants and the non-dispatchable resources. As our electric energy becomes more diverse in its generation resources, the HES with its operational control system, its real-time view and its dynamic decisions making will become an essential part of the integrated energy systems and improve the overall grid reliability. The operational constraints of the energy sources on both the thermal power plants and the non-dispatchable resources in HES, plays a vital role in the planning and design stage. It is an established fact that the choice of energy source depends on the available natural resources and possible infrastructure. A critical component of decision-making depends on the complementary nature and controllability of the energy sources to supply the load demands with high reliability. Controllability of complex HES to achieve desired performance and flexibility is implemented via coordinated control systems while simultaneously generating electricity and other useful products such as useful heat or hydrogen. These systems are based on instrumentation, signal processing, control theory, and engineering system design. The entire HES along with the control systems are characterized by widely varying time constants. Hence, for a well-coordinated control and operation, we propose physics based modeling of the subsystems to assist in a dynamic and transient analysis. Dynamic and transient analysis in real and non-real time domain of the potential sources is capable of providing satisfactory results at the feasibility analysis stage. A simplified HES consisting of complementary energy sources is used to demonstrate the proposed approach. Suitable real time simulations to perform dynamic and transient analysis will be performed to verify results from the non-real time analysis. The role of such analyses, especially the real time dynamic and transient analysis for manual controls is elaborated. It is also discussed that faster than real time simulation will pave the future for controller rooms and hence manual control procedures. Multiple tools such as Real Time Simulator, Matlab®, Simulink®, PSCAD®, MOOSE, etc. are expected to be used for the HES analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review and Future Perspective of Central Receiver Design and Performance

Concentrating solar power (CSP) technology provides a commercial solar option to the utility-scale electricity market. CSP is unique in its ability to include low-cost thermal storage; thus, it can generate electricity when the sun is not available and dispatch electricity to meet varying load requirements. Within the suite of CSP technologies, the central receiver design represents the state-of-the-art technology, promising low cost, high performance, and dispatchable energy production. Current total capacity of central receiver plants worldwide is about 1.0 gigawatt (electric) with operating plants in Spain and the United States, as well as projects under construction in Asia, the Middle East, and North Africa. Central receiver technology has been under development since the 1950s, and a variety of central receiver designs have been explored. A distinguishing feature is the heat transfer medium. Central receiver designs exist that use dense fluids, gases, and solid particles in this role. Water/steam and molten salt receivers have been adopted in current commercial plants and are often coupled with a steam-Rankine power cycle with an operating temperature of less than 600 degrees C. Many new central receiver concepts, such as the volumetric air, supercritical carbon dioxide (sCO2), solid particle, and liquid-metal receiver designs, are under active research and development (R&D). New designs target operating temperatures generally higher than 700 degrees C-800 degrees C -- and even above 1000 degrees C -- so that higher-performance power cycles such as the sCO2-Brayton cycle or air-Brayton/steam-Rankine combined cycle can be used to promote greater overall system efficiency. Central receiver thermal storage provides dispatchability unavailable from variable-output renewables such as solar photovoltaic and wind power. Case study analysis of the California grid shows that there is a limit on the amount of non-dispatchable renewable generation that the grid can accommodate, beyond which overgeneration, spillage, and instability may occur. Energy storage may well become a necessity in some areas in order to maintain reliability. Next-generation central receiver technologies will have higher operating temperatures and additional features that allow higher-efficiency power generation and deliver other cost-performance advantages. The underlying innovations will come from areas such as multi-physics modeling, high-temperature materials, novel power cycles and heat exchanger designs, and collector field sensing and performance monitoring technologies. Technology innovation is expected to improve the cost and performance of central receiver designs. To deliver value as a generation and storage option, central receiver technology must also be supported by flexible and robust financial models and comprehensive energy and ancillary service markets justifying the capital-intensive investment. Progress in these areas will position CSP central receiver technology for future deployment.

14 SOLAR ENERGY↗

Feasible Actuator Range Modifier (FARM), a Tool Aiding the Solution of Unit Dispatch Problems for Advanced Energy Systems

Integrated energy systems (IESs) seek to minimize power generating costs in future power grids through the coupling of different energy technologies. To accommodate fluctuations in load demand due to the penetration of renewable energy sources, flexible operation capabilities must be fully exploited, and even power plants that are traditionally considered as base-load units need to be operated according to unconventional paradigms. Thermomechanical loads induced by frequent power adjustments can accelerate the wear and tear. If a unit is flexibly operated without respecting limits on materials, the risk of failures of expensive components will eventually increase, nullifying the additional profits ensured by flexible operation. In addition to the bounds on power variations (explicit constraints),the solution of the unit dispatch problem needs to meet the limits on the variation of key process variables, including temperature, pressure and flow rate (implicit constraints).The FARM (Feasible Actuator Range Modifier) module was developed to enable existing optimization algorithms to identify solutions to the unit dispatch problem that are both economically favorable and technologically sustainable. Thanks to the iterative dispatcher–validator scheme, FARM permits addressing all the imposed constraints without excessively increasing the computational costs. In this work, the algorithms constituting the module are described, and the performance was assessed by solving the unit dispatch problem for an IES composed of three units, i.e., balance of plant, gas turbine, and high-temperature steam electrolysis. Finally, the FARM module provides dedicated tools for visualizing the response of the constrained variables of interest during operational transients and a tool aiding the operator at making decisions. These techniques might represent the first step towards the deployment of an ecological interface design (EID) for IES units.

47 OTHER INSTRUMENTATION↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A novel means to flexibly operate a hybrid concentrated solar power plant and improve operation during non-ideal direct normal irradiation conditions

Hybridization of concentrated solar power (CSP) with other energy sources can drastically increase how much solar energy is harnessed and potentially expand the current geographical deployment of CSP installlations. In this study, a novel operation strategy referred to as flexible heat integration (FHI), is proposed and applied to a hybrid CSP-natural gas power plant. The proposed plant, modeled in Simulink, employs a solar central receiver (SCR) and dual-source gas boiler to drive a steam Rankine power cycle. FHI involves collecting and dispatching solar energy at modified temperatures during off-design direct normal irradiance (DNI). During low-grade (<100 W/m 2 ) and medium-grade (100–500 W/m 2 ) levels of DNI, molten salt is used for steam boiling and feedwater preheating, respectively, rather than superheating usually seen in SCR steam plants. Hybrid gas-firing supplies energy to bypassed systems. FHI is applied to a hybrid plant over the course of a day from each season for a plant located in Salt Lake City, Utah, an unconventional location due to off-design DNI variability. A spring day exhibiting variable DNI is used as the main case study to demonstrate the dynamics and robust operation under the FHI framework. The operation of the plant over the winter day shows the largest improvement in solar-to-electric (STE) efficiency whereas the summer day exhibits the smallest improvement. Monthly results follow a similar trend with FHI improving STE from 15.3% and 16.3% to 17.0% and 16.7% in January and July, respectively. Yearly results show FHI improving STE efficiency from 16.1% to 17.1% relative to standard hybrid operation. Altogether, the proposed concept expands the current understanding of energy management in hybrid SCR-natural power plants under non-ideal DNI conditions and locations that have lower DNI by applying FHI.

14 SOLAR ENERGY↗