Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “degradation diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fault Diagnosis in HVAC Chillers

Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

Choi, Kihoon↗

Autonomous System for Monitoring the Integrity of Composite Fan Housings

A low-cost and reliable system assesses the integrity of composite fan-containment structures. The system utilizes a network of miniature sensors integrated with the structure to scan the entire structural area for any impact events and resulting structural damage, and to monitor degradation due to usage. This system can be used to monitor all types of composite structures on aircraft and spacecraft, as well as automatically monitor in real time the location and extent of damage in the containment structures. This diagnostic information is passed to prognostic modeling that is being developed to utilize the information and provide input on the residual strength of the structure, and maintain a history of structural degradation during usage. The structural health-monitoring system would consist of three major components: (1) sensors and a sensor network, which is permanently bonded onto the structure being monitored; (2) integrated hardware; and (3) software to monitor in-situ the health condition of in-service structures.

Qing, Xinlin P.↗

Long-term photothermal/humidity testing of photovoltaic module polymer insulations and cover films

The life expectancies of Tedlar and other polymer films considered for use as cover materials in terrestrial photovoltaic (PV) modules were investigated by exposing them for more than 13,000 h on an outdoor test stand and for up to 10,000 h in several accelerated multistress environments. Visual observations and diagnostic analyses of weight and mechanical strength losses were periodically conducted to assess the nature and rate of degradation of mechanical properties and to assess the effects of film thickness and UV stabilizer content. Spectroscopic analyses of pristine and degraded materials linked weight and mechanical property losses to the underlying photothermal/photooxidation chemistry. It is shown that heavy doses of UV stabilizers prolong, while elevated temperatures shorten, the useful life of these materials; humidity plays only a minor role. The most heavily UV-stabilized films are expected to operate usefully in a PV module front-cover application for only five to ten years. The performance of none of the tested films appears consistent with the 20-30 year life goals of the PV industry.

Mon, G.↗

Diagnostics for measuring 4D beam matrix [Slides]

Detailed knowledge on the particle distribution in accelerators can strongly benefit machine tuning and understanding of deleterious effects, which degrade beam quality. Properties of the beam downstream the beamline (i.e. 4D beam matrix) depend on beam properties upstream and parameters of the beamline. Measuring 2D x-y beam profile downstream provides limited information about the beam. Multiple measurements at different settings of the beamline (quadrupole scan) may provide enough information to recover original beam profile. Essentially, this concept is similar to tomography, when we need to reconstruct a higher dimension object from multiple low dimension projections.

43 PARTICLE ACCELERATORS↗

Aging Mechanisms of Broad Area ~800 nm Laser Diodes

Here, this work presents a comprehensive study of early aging behavior (<500 hr) in ~800 nm, phosphide-based laser diodes grown by solid-source MBE with different oxygen concentration levels incorporated into the diode epitaxial layers during growth. The data indicate that lasing characteristics prior to aging are degraded by oxygen introduction, but the gradual power degradation rate after the onset of aging is not a strong function of oxygen at these concentration levels. Devices with oxygen concentrations of ~2.5 × 10 15 cm -3 showed significantly longer delay before the onset of aging (incubation time) than devices with less than 1 × 10 15 cm -3 oxygen. Generation-Recombination current and Laser Beam Induced Current measurements indicate that defect densities and aggregation are suppressed at the facets by oxygen, which can explain longer incubation times. Diagnostic data and parametric fits to diode simulation models show that increased cavity optical loss and defect density are primarily responsible for gradual power degradation during aging, rather than changes in nonradiative recombination. Mechanisms are proposed that explain this behavior, based on density functional theory (DFT) simulations and known recombination-enhanced defect generation phenomena.

47 OTHER INSTRUMENTATION↗

Advanced Monitoring and Control in the ANL METL Facility Using an Engineering Digital Twin

The potential benefits of using an engineering digital twin to achieve greater autonomy for monitoring and control functions in advanced reactors was investigated for the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The METL sodium purification system served as a representative system as it requires significant human in-the-loop interaction to accomplish its design function. The objective was to demonstrate how real-time operation could be automated while preserving oversight of the operator for ensuring that the system design functions are met. A digital twin model of the purification system was developed for both the cold trap purification loop and plugging meter diagnostic loop using information from the METL piping and instrumentation diagram (P&ID). Automated monitoring and diagnosis of component degradation in the METL facility was demonstrated in tests using the PRO-AID health monitoring software with the digital twin model incorporated in the library of components. Component failures were introduced and were successfully diagnosed in real time. These tests serve to demonstrate an advanced monitoring capability able to differentiate sensor degradation from component degradation, to generate a rank ordering of probabilities of different failure mechanisms that serves to circumvent the false alarm problem with current anomaly detection methods, and how facility monitoring can be transformed from anomaly detection to identification of a specific fault. Automated control of the purification system was demonstrated through simulations that exercised a model predictive controller designed using the digital twin model. Results of these simulations compared favorably with experimental data showing very good reference tracking response with negligible overshoot. In conclusion, these pilot tests and simulations successfully demonstrated the use of a digital twin for improved automation of monitoring and control. It was shown how the digital twin enables switching between control modes from cold trap operation where impurities are removed to plugging meter operation where impurity concentrations are measured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SAVANT: Solar Array Verification and Analysis Tool Demonstrated

The photovoltaics (PV) industry is now being held to strict specifications, such as end-oflife power requirements, that force them to overengineer their products to avoid contractual penalties. Such overengineering has been the only reliable way to meet such specifications. Unfortunately, it also results in a more costly process than is probably necessary. In our conversations with the PV industry, the issue of cost has been raised again and again. Consequently, the Photovoltaics and Space Environment Effects branch at the NASA Glenn Research Center at Lewis Field has been developing a software tool to address this problem. SAVANT, Glenn's tool for solar array verification and analysis is in the technology demonstration phase. Ongoing work has proven that more efficient and less costly PV designs should be possible by using SAVANT to predict the on-orbit life-cycle performance. The ultimate goal of the SAVANT project is to provide a user-friendly computer tool to predict PV on-orbit life-cycle performance. This should greatly simplify the tasks of scaling and designing the PV power component of any given flight or mission. By being able to predict how a particular PV article will perform, designers will be able to balance mission power requirements (both beginning-of-life and end-of-life) with survivability concerns such as power degradation due to radiation and/or contamination. Recent comparisons with actual flight data from the Photovoltaic Array Space Power Plus Diagnostics (PASP Plus) mission validate this approach.

Chock, Ricaurte↗

Vehicle Integrated Prognostic Reasoner (VIPR) Metric Report

This document outlines a set of metrics for evaluating the diagnostic and prognostic schemes developed for the Vehicle Integrated Prognostic Reasoner (VIPR), a system-level reasoner that encompasses the multiple levels of large, complex systems such as those for aircraft and spacecraft. VIPR health managers are organized hierarchically and operate together to derive diagnostic and prognostic inferences from symptoms and conditions reported by a set of diagnostic and prognostic monitors. For layered reasoners such as VIPR, the overall performance cannot be evaluated by metrics solely directed toward timely detection and accuracy of estimation of the faults in individual components. Among other factors, overall vehicle reasoner performance is governed by the effectiveness of the communication schemes between monitors and reasoners in the architecture, and the ability to propagate and fuse relevant information to make accurate, consistent, and timely predictions at different levels of the reasoner hierarchy. We outline an extended set of diagnostic and prognostics metrics that can be broadly categorized as evaluation measures for diagnostic coverage, prognostic coverage, accuracy of inferences, latency in making inferences, computational cost, and sensitivity to different fault and degradation conditions. We report metrics from Monte Carlo experiments using two variations of an aircraft reference model that supported both flat and hierarchical reasoning.

Cornhill, Dennis↗

Radiation Aging of Cable Insulation Systems to Support Extension of Cable Electrical Assessment Techniques - CRADA 562 (Final Report)

Radiation aging (primarily gamma radiation) affects a small subset of the LV cable population based on a 40-year operation. Increasing plant operating life to 60 or 80 years will result in additional cables experiencing degradation, either from radiation or from combined thermal and radiation effects. Previous research work done by EPRI and other researchers focuses on electrical diagnostics of thermal effects. However, the electrical diagnostic response of the cable system to radiation aging is minimally understood. In order to study the electrical responses from XLPE and EPR cabling and correlate these responses with radiation dose and level of thermal exposure, gamma radiation testing was performed at Pacific Northwest National Laboratory (PNNL). This report covers the radiation testing performed at PNNL, which involved irradiation of 30-foot long cables and short witness samples. The cabling was irradiated, at room temperature, using cobalt-60 gamma-rays to intervals of 10 million rads (10 Mrads), for a maximum of 70 Mrads. The results can be used to determine cable conditions (extent of damage) more accurately and localize where the degradation exists along the length of the cable (axial location). These insights can provide operators with the options to focus repair, mitigation, or replacement efforts locally.

36 MATERIALS SCIENCE↗

Mechanical Properties of Carbon Fiber Reinforced Composites Exposed to Cryogenic Conditions and Space Radiation via Simulation and Testing

As NASA missions extend beyond low Earth orbit, increasing reliance is placed on carbon fiber reinforced polymer (CFRP) composites for spacecraft structures where mass efficiency, durability, and long-term reliability are critical. In service, these materials are subjected to a combination of ultraviolet radiation, vacuum, ionizing radiation, atomic oxygen, and extreme thermal excursions under sustained mechanical loading. Flight systems such as the Boeing Starliner and SpaceX Dragon employ external composite structures that will experience these environments for extended durations. Although prior spaceflight and ground studies have reported limited changes in bulk mechanical properties, the synergistic effects of these environments on composite microstructure, particularly at the fiber matrix interphase, remain insufficiently characterized and represent a potential qualification and reliability risk. This study investigates the effects of short-term cryogenic exposure on a radiation shielding carbon epoxy composite, SC2020, as a ground-based analog for space relevant thermal extremes. The SC2020 material system has previously flown on the International Space Station under the Materials International Space Station Experiment (MISSE) program. Composite specimens were exposed to liquid nitrogen for 6 and 24 hours and evaluated using a multiscale characterization framework that combined ASTM D3039 tensile testing, Atomic Force Microscopy (AFM) based interphase analysis, and helium gas permeability measurements. Tensile testing showed no statistically significant or permanent degradation in global strength or modulus following cryogenic exposure. In contrast, AFM measurements revealed reductions in interphase modulus, weakened adhesion, and increased nanoscale heterogeneity, indicating localized degradation mechanisms not captured by conventional bulk testing. Gas permeability measurements showed a progressive increase in helium diffusion with exposure duration, consistent with micro-void formation or partial interfacial debonding. The results indicate that cryogenic exposure initiates degradation at the fiber matrix interphase while leaving global mechanical properties largely unchanged over short durations. These findings underscore the importance of multiscale diagnostics for identifying early-stage damage mechanisms that may influence long term performance and qualification margins for spaceflight composite structures. The data presented establish a cryogenic baseline for comparison with forthcoming MISSE flight exposure results and support ongoing NASA Established Program to Stimulate Competitive Research (EPSCoR) efforts aimed at improving composite qualification methodologies, risk assessment, and reliability prediction for space environments.

composite reliability↗

MDPCT1 Quench Data and Performance Analysis

MDPCT1 is a four-layer cos-theta Nb3Sn dipole demonstrator developed and tested at FNAL in the framework of the U.S. Magnet Development Program. The magnet reached record fields for accelerator magnets of 14.1 T at 4.5 K in the first test and 14.5 T at 1.9 K in the second test and then showed large degradation. While its inner coils performed exceptionally well with only two quenches up to 14.5 T and no evidence of degradation, the outer coils degraded over the course of testing. By adopting new measurement and analysis techniques at FNAL we are discussing in detail what happened. Both success and failure in our diagnostics are discussed. The evolution of techniques over the course of two tests (and three thermal cycles) shows the path to address challenges brought by the first four-layer magnet tested at FNAL. This paper presents the analysis of quench data along with diagnostic features and complementary measurements taken in support of the magnet performance analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic Visual Acuity: a Functionally Relevant Research Tool

Coordinated movements between the eyes and head are required to maintain a stable retinal image during head and body motion. The vestibulo-ocular reflex (VOR) plays a significant role in this gaze control system that functions well for most daily activities. However, certain environmental conditions or interruptions in normal VOR function can lead to inadequate ocular compensation, resulting in oscillopsia, or blurred vision. It is therefore possible to use acuity to determine when the environmental conditions, VOR function, or the combination of the two is not conductive for maintaining clear vision. Over several years we have designed and tested several tests of dynamic visual acuity (DVA). Early tests used the difference between standing and walking acuity to assess decrements in the gaze stabilization system after spaceflight. Supporting ground-based studies measured the responses from patients with bilateral vestibular dysfunction and explored the effects of visual target viewing distance and gait cycle events on walking acuity. Results from these studies show that DVA is affected by spaceflight, is degraded in patients with vestibular dysfunction, changes with target distance, and is not consistent across the gait cycle. We have recently expanded our research to include studies in which seated subjects are translated or rotated passively. Preliminary results from this work indicate that gaze stabilization ability may differ between similar active and passive conditions, may change with age, and can be affected by the location of the visual target with respect to the axis of motion. Use of DVA as a diagnostic tool is becoming more popular but the functional nature of the acuity outcome measure also makes it ideal for identifying conditions that could lead to degraded vision. By doing so, steps can be taken to alter the problematic environments to improve the man-machine interface and optimize performance.

Peters, Brian T.↗

Detection of Anatoxins in Human Urine by Liquid Chromatography Triple Quadrupole Mass Spectrometry and ELISA

Harmful cyanobacterial blooms are becoming more common and persistent around the world. When in bloom, various cyanobacterial strains can produce anatoxins in high concentrations, which, unlike other cyanobacterial toxins, may be present in clear water. Potential human and animal exposures to anatoxins occur mainly through unintentional ingestion of contaminated algal mats and water. To address this public health threat, we developed and validated an LC-MS/MS method to detect anatoxins in human urine to confirm exposures. Pooled urine was fortified with anatoxin-a and dihydroanatoxin at concentrations from 10.0 to 500 ng/mL to create calibrators and quality control samples. Samples were diluted with isotopically labeled anatoxin and solvent prior to LC-MS/MS analysis. This method can accurately quantitate anatoxin-a with inter- and intraday accuracies ranging from 98.5 to 103% and relative standard deviations < 15%, which is within analytical guidelines for mass spectrometry methods. Additionally, this method qualitatively detects a common degradation product of anatoxin, dihydroanatoxin, above 10 ng/mL. We also evaluated a commercial anatoxin-a ELISA kit for potential diagnostic use; however, numerous false positives were detected from unexposed individual human urine samples. In conclusion, we have developed a method to detect anatoxins precisely and accurately in urine samples, addressing a public health area of concern, which can be applied to future exposure events.

urine↗

The global Cretaceous-Tertiary fire: Biomass or fossil carbon

The global soot layer at the K-T boundary indicates a major fire triggered by meteorite impact. However, it is not clear whether the principal fuel was biomass or fossil carbon. Forests are favored by delta value of C-13, which is close to the average for trees, but the total amount of elemental C is approximately 10 percent of the present living carbon, and thus requires very efficient conversion to soot. The PAH was analyzed at Woodside Creek, in the hope of finding a diagnostic molecular marker. A promising candidate is 1-methyl-7-isopropyl phenanthrene (retene,), which is probably derived by low temperature degradation of abietic acid. Unlike other PAH that form by pyrosynthesis at higher temperatures, retene has retained the characteristic side chains of its parent molecule. A total of 11 PAH compounds were identified in the boundary clay. Retene is present in substantial abundance. The identification was confirmed by analysis of a retene standard. Retene is characteristic of the combustion of resinous higher plants. Its formation depends on both temperature and oxygen access, and is apparently highest in oxygen-poor fires. Such fires would also produce soot more efficiently which may explain the high soot abundance. The relatively high level of coronene is not typical of a wood combustion source, however, though it can be produced during high temperature pyrolysis of methane, and presumably other H, C-containing materials. This would require large, hot, low O2 zones, which may occur only in very large fires. The presence of retene indicates that biomass was a significant fuel source for the soot at the Cretaceous-Tertiary boundary. The total amount of elemental C produced requires a greater than 3 percent soot yield, which is higher than typically observed for wildfires. However, retene and presumably coronene imply limited access of O2 and hence high soot yield.

Gilmour, Iain↗

Periodic Application of Concurrent Error Detection in Processor Array Architectures

Processor arrays can provide an attractive architecture for some applications. Featuring modularity, regular interconnection and high parallelism, such arrays are well-suited for VLSI/WSI implementations, and applications with high computational requirements, such as real-time signal processing. Preserving the integrity of results can be of paramount importance for certain applications. In these cases, fault tolerance should be used to ensure reliable delivery of a system's service. One aspect of fault tolerance is the detection of errors caused by faults. Concurrent error detection (CED) techniques offer the advantage that transient and intermittent faults may be detected with greater probability than with off-line diagnostic tests. Applying time-redundant CED techniques can reduce hardware redundancy costs. However, most time-redundant CED techniques degrade a system's performance.

Chen, Paul Peichuan↗

Examining the Role of IMU Health Characterization and Monitoring in UAS Safety

Inertial measurement units (IMUs) can be vital for vehicle attitude and position estimation in unmanned aerial vehicles (UAVs). Degradation in these units could result in incorrect position estimates that are utilized in vehicle control, trajectory prediction, and other critical systems; however, the modes and effects of degradation in these IMUs are not well understood. In order to quantify the risk posed by degradation in these sensors, a study was conducted on the types of IMUs prevalent in the commercial market, their known failure modes, and the applicability to health monitoring methods for risk reduction and increased safety in an increasingly autonomous airspace. First, use cases and failure modes of the various types and reliability of commercially available IMUs were reviewed, and knowledge gaps and issues in the field were identified. Noting that inexpensive and lightweight MEMS (Microelectromechanical Systems) IMUs are some of the most commonly used but least reliable sensors in sUAS (small Unmanned Aerial Systems), five inexpensive MEMS IMUs were chosen for a performance evaluation study, selected from the Pixhawk autopilot systems, hobby sUAS, and prior NASA experimental studies. For each of these IMUs, a 10-minute bias test and a 12-hour drift test were performed for the accelerometers in a benchtop setting, using a BeagleBone Black for data collection. Using these results, the sensors’ performance is compared to their reported specifications, and the utility of implementing diagnostic methods for MEMS IMUs for research and commercial applications is evaluated. The paper concludes with a planned study for the evaluation of vibration-induced degradation for the selected sensors.

IMUs↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗

Degradation of Fuel Cell Membrane Electrode Assemblies from Buses Operated More than 25,000 h

This study investigates the performance losses and degradation of proton-exchange-membrane fuel-cell stacks taken from the Alameda Contra Costa Transit District (AC Transit) bus system (Alameda and Contra Costa counties, California, United States) that were operated for over 25,000 h. Here, we focus on the origin of differences in electrochemical performance between beginning-of-life (BOL) and end-of-life states as well as diagnostic data acquired during the lifetime of the buses. In doing so, we employ in- and ex- situ characterization methods such as polarization curves, electrochemical impedance spectroscopy, electron microscopy, and X-ray characterization. Uniform degradation of the catalyst layer including Pt agglomeration/migration and electrode thinning was observed in all of the post-teardown measurements compared to BOL materials resulting from years of field operation. Despite these changes, the measured post-teardown performance suggests a sufficient output for the expected load, which indicate factors other than degradation of the membrane-electrode assemblies (MEAs) are likely responsible for the decommissioning of the stacks. The findings indicate that these MEA materials can enable long lifetime in fuel-cell vehicles, if the MEAs are not subjected to adverse operating conditions. The results also highlight the need for more in-vehicle diagnostics to maximize the lifetime of fuel cell vehicle (FCV) powerplants.

25 ENERGY STORAGE↗