Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “degradable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Multiscale Characterization of Electrode-Induced Degradation in Perovskite Solar Cells

The stability of metal-halide-perovskite (MHP) solar cells must be understood and improved for the commercial viability of MHP technologies. Here, we apply multiscale characterization methods to study degradation modes, specifically electrode corrosion, for p-i-n MHP partial device stacks and full devices that are stored in the dark under an inert atmosphere. Our multiscale characterization approaches include full-device electro-optical performance using current-voltage (JV) curves and spatial imaging with electroluminescence (EL) and photoluminescence (PL). We further correlate interface properties using cross-sectional Kelvin probe force microscopy, which maps the nanoscale electric field properties, and electron microscopy, which demonstrates structural and chemical features. Devices stored as a full device stack degrade primarily by metal (Ag) electrode diffusion into the absorber, with formation of AgI byproducts and Ag accumulation near the indium tin oxide (ITO) contact. This causes decomposition of the perovskite absorber domains, loss of the potential drop at the electron transport layer (ETL)/perovskite interface near the metal contact, and increased equivalent resistance at the perovskite/hole transport layer (HTL) interface near the ITO contact. The devices stored without metal show a different degradation pathway dominated by corrosion of the ITO, creating voids at the ITO electrode surface with diffusion of In and Sn into the absorber. We conclude that metal electrode-induced degradation is the most severe degradation pathway under dark storage, but that ITO corrosion and absorber instability must also be mitigated. We further demonstrate mitigation of these degradation pathways by changes to the device stack, including a SnO x blocking layer at the ETL side and replacing ITO with FTO at the HTL side. These results provide a useful demonstration of specific dark degradation pathways at each electrode interface, as well as a unique multiscale example that links degradation of chemical, structural, and electrical interface properties to the full-device electro-optical characteristics.

14 SOLAR ENERGY↗

Degradation and deforestation increase the sensitivity of the Amazon Forest to climate extremes

About 40% of the Brazilian Amazon has been deforested or suffered changes in forest structure through degradation (selective logging, fires, and fragmentation). The impact of forest degradation on the forest’s sensitivity to climate extremes has not been fully explored because of a lack of data and the complex interplay of forest structure and climate drivers. Here, we combined forest structure data from 545 airborne lidar transects (375 ha each) across the Brazilian Amazon with the Ecosystem Demography Model (ED2). We explore the forest’s functional response to near-present (1981–2019) climate extremes under observed forest structure from lidar ( Control ) and two forest structure change scenarios: (1) forest recovery by excluding all future deforestation and degradation ( Recovery ) and (2) expansion of selective logging and deforestation ( Degradation ). Using the Control simulation, we found a close and positive association between local forest aboveground biomass and the predicted gross primary productivity (GPP) and evapotranspiration (ET). Moreover, both GPP and ET respond negatively to extremes in vapor pressure deficit and downwelling shortwave irradiance in degraded forests in Eastern and Southern Amazon, indicating high sensitivity to droughts. Locally high-biomass forest patches showed little or no negative response of GPP and ET to extreme drought conditions whereas low-biomass forest patches in the same locations—typically degraded forest canopies—responded negatively to higher moisture stress. The results from the Recovery scenario showed similar results to simulations with observed structure; however, under the Degradation scenario, low-biomass forest patches became more abundant, resulting in more regions where GPP and ET are negatively impacted by hot drought conditions according to the ED2 model. Our results suggest that local forest structure is a critical determinant of an ecosystem’s response to climate variability, and that the loss of canopy trees in the Amazon through forest degradation could increase and expand forest vulnerability to droughts.

54 ENVIRONMENTAL SCIENCES↗

Influence of Tabula Rasa on Process- and Light-Induced Degradation of Solar Cells Fabricated From Czochralski Silicon

Monocrystalline Si solar cells are fabricated from Czochralski (Cz) Si, which contains 10 17 –10 18 cm -3 oxygen atoms. Cz Si undergoes degradation during high-temperature thermal processing steps, such as dopant diffusion to form the p - n junction. This degradation in the bulk minority carrier lifetime can be related to the formation of oxygen precipitates. We found that a high-temperature annealing process known as tabula rasa (TR) not only mitigates process-induced degradation via oxygen precipitate nuclei dissolution, but also modifies subsequent light-induced degradation. We report on the bulk carrier lifetime of n - and p -type Cz Si after TR, which homogenizes the interstitial oxygen in the bulk Si to its monoatomic form in either an N 2 or O 2 environment. A control sample, which was not subjected to a TR processing step, experienced severe process-induced degradation during a boron emitter thermal budget as oxygen precipitates were formed in the Si bulk. These precipitates could be imaged using photoluminescence. Additionally, samples that underwent a TR processing step prior to the boron emitter thermal budget show efficient gettering of metallic impurities compared to the control sample, which showed a decline in the implied open-circuit voltage after the gettering step. Furthermore, modification of the interstitial oxygen bonding by TR had a strong effect on the light-induced degradation kinetics. Instead of a typically observed monotonic decrease, minority carrier lifetime increases first, followed by a nonmonotonic decrease over a ~20 h period. Finally, we conclude that by modifying the interstitial oxygen bonding via TR pretreatment, p -type Cz Si wafers become substantially resistant to harsh solar cell processes and strongly modified light-induced degradation, which would open alternative ways to mitigate this degradation mechanism.

14 SOLAR ENERGY↗

Investigating the Crosslinking, Degradation, and Adhesion Behavior of Photovoltaic Encapsulants Under Thermal Accelerated Aging

Degradation of photovoltaic (PV) module encapsulant characteristics that lead to mechanical embrittlement and delamination remains a cause of failure in solar installations. A multiscale reliability model connecting the encapsulant mechanical and fracture properties to the degraded molecular structure and interfacial bonding to adjacent solar cell and glass substrates was previously published. The model, developed primarily for poly(ethylene-co-vinyl acetate) acetate (EVA) encapsulants, remains to be experimentally validated. Determining the degradation and crosslinking kinetics of alternative encapsulants, such as polyolefin elastomer (POE) and EVA/POE/EVA composites (EPE), can generalize the model. In this work, we subject fully cured EVA, POE, and EPE encapsulants to accelerated thermal aging to determine how high temperatures impact reaction kinetics. An increase in gel content (crosslinking) and decrease in crystallinity of the encapsulants under hot-aerobic (90 degrees C, 22% RH) and hot-anaerobic (90 degrees C, sealed in N 2 air) aging were observed, even in the absence of UV and crosslinking initiators. Fourier transform infrared spectroscopy (FTIR)-attenuated total reflectance analysis showed insignificant encapsulant degradation, demonstrating the critical role of UV and moisture in accelerating degradation. Adhesion testing performed on coupon-level specimens (cell/encapsulant/glass laminates) showed decreases in adhesion energy, Gc , from 5000 h of hot-dry (90 degrees C, ~1% RH) and hot-humid (90 degrees C, 60% RH) aging. POE coupons demonstrated the best stability, followed by EPE then EVA. For EVA and POE, hot-humid aged coupons experienced a larger decrease in Gc due to enhanced hydrolytic degradation. Hot-dry aging condition demonstrated that thermal degradation of the interface could be significant even if the encapsulant experiences negligible degradation in the absence of UV and elevated humidity.

accelerated aging↗

Modeling Synergistic Fuel Cell Membrane Degradation with Mitigating Effects of Cerium

During operation, polymer-electrolyte-membrane (PEM) fuel cells undergo mechanical and chemical degradation mechanisms, which behave synergistically and lead to accelerated membrane degradation over time. This study builds upon previous modeling work on mechanical degradation as described by a pinhole in the membrane and the effects of cerium on chemical degradation.1 By combining these two models, analysis can be carried out on the coupled degradation methods and how the mitigation effects of cerium disrupt the degradation cycle. The mechanical model represents a pinhole in the membrane using an effective void fraction, which allows for increased gas crossover through the membrane and impacts the membrane transport and mechanical properties. A microkinetic model for the chemical degradation is included in the model, including attack of the membrane polymer by hydroxyl radicals as well as the mitigation reaction for quenching of hydroxyl radicals with cerium. A concentrated solution theory approach is used to model the transport of cerium ions throughout the cell.2 The model results show how the location of cerium in the cell can be used to prevent chemical degradation. In addition, the model shows how cerium slows down the rate of pinhole growth by reducing the gas crossover and membrane thinning rate. Finally, the model can be used to optimize the distribution of cerium in the membrane and catalyst layers by balancing trade-offs between lowering degradation rates and decreasing fuel cell performance.

25 ENERGY STORAGE↗

Industry Facing PV Degradation Prediction Tool and Database to Enable a 50-Year Life Module

The Photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 years. Furthermore, research efforts aim for up to 50 years of service life while keeping performance degradation at a minimum for decades of outdoor weathering - putting additional pressure on improving the accuracy of long-term durability and reliability assessments. Here there is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. A graphical user interface will aid in the understanding of the results. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. We use an integration pipeline approach that allows us to leverage weather data from the National Solar Radiation Database to perform geospatial degradation analysis in the US and worldwide. Our repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors. We hope to become a repository that can be used for weathering and degradation analysis for various applications beyond the PV industry.

degradation↗

Ultrasonic degradation of GenX (HFPO-DA) – Performance comparison to PFOA and PFOS at high frequencies

Sonolytic degradation kinetics of hexafluoropropylene oxide-dimer acid (HFPO-DA or GenX) were studied for the first time at four high ultrasonic frequencies (375, 580, 860 and 1,140kHz) and three power densities (200, 300 and 400W/L), and compared to the degradation of previously studied perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS). The frequency of 580kHz displayed the highest degradation of all three PFAS tested. Within each frequency, the degradation performance increased consistently with increasing power density. Degradation rates were highest for GenX over PFOA to PFOS (k GenX = 0.0501 min -1 , k PFOA = 0.0444 min -1 , k PFOS 0.0153 min -1 ), which is in direct agreement with their reported thermal stability (PFOS > PFOA > GenX). No known by-product formation as expected from the literature on truncation mechanism was detected in the samples (i.e. shorter chain carboxylic acid PFAS). Further, fluorine mass balance experiments at 580kHz and 400W/ L confirmed that GenX defluorinated fastest among the three tested PFAS and had lowest loss of fluorine in the mass balance. Degradation experiments with a mixture of all three PFAS displayed lower degradation rates than the individual experiments, where PFOA exhibited the largest reduction in degradation rate (by 31%), followed by GenX (by 19%), and finally by PFOS (by 17%). Overall, our study demonstrates that ultrasound can provide effective destruction of different PFAS (70-90% fluorine from mitigated PFAS was detected as inorganic fluoride) with a similar energy demand to alternative PFAS treatment methods reported in literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bisphenol A degradation by manganese oxides at circumneutral pH: Quantitative evaluation of dissolved Mn(III) species with pyrophosphate

Although trivalent manganese (Mn(III)) species have been recognized as crucial intermediates in the degradation of organic contaminants by Mn oxides, quantitative research on their specific roles remains scarce. Here, our study investigated the degradation processes of an organic pollutant, Bisphenol A (BPA), by dissolved Mn(III) and Mn(III)-bearing oxides, and elucidated the differences of the underlying mechanisms and reaction pathways between several Mn oxides and dissolved Mn(III). Our results indicated that BPA degradation rates with Mn(III)-bearing oxides alone follow the order: δ-MnO 2 >> γ-MnOOH > Mn 3 O 4 . Adding pyrophosphate (PP) significantly enhanced BPA degradation by promoting the formation of Mn(III)-PP complexes and exposing more reactive sites, achieved through destabilizing the crystal structure and mitigating of Mn(II) readsorption, particularly in γ-MnOOH and Mn 3 O 4 . Our kinetic model revealed that heterogeneous degradation by Mn oxides is the predominant reaction pathway, accounting for 61.4 %, 87.8 %, and 73.8 % of the total degraded BPA for δ-MnO 2 , γ-MnOOH, and Mn 3 O 4 , respectively, even in the presence of significant amount of dissolved Mn(III) intermediates due to high PP concentrations. These results offer mechanistic details on BPA degradation by Mn oxides and the influence of ligand concentration, providing helpful insights for optimizing degradation strategies of organic pollutants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Degradation on Water, Energy, and Carbon Cycling of the Amazon Tropical Forests

Selective logging, fragmentation, and understory fires directly degrade forest structure and composition. However, studies addressing the effects of forest degradation on carbon, water, and energy cycles are scarce. Here, we integrate field observations and high-resolution remote sensing from airborne lidar to provide realistic initial conditions to the Ecosystem Demography Model (ED-2.2) and investigate how disturbances from forest degradation affect gross primary production (GPP), evapotranspiration (ET), and sensible heat flux (H). We used forest structural information retrieved from airborne lidar samples (13,500 ha) and calibrated with 817 inventory plots (0.25 ha) across precipitation and degradation gradients in the eastern Amazon as initial conditions to ED-2.2 model. Our results show that the magnitude and seasonality of fluxes were modulated by changes in forest structure caused by degradation. During the dry season and under typical conditions, severely degraded forests (biomass loss ≥66%) experienced water stress with declines in ET (up to 34%) and GPP (up to 35%) and increases of H (up to 43%) and daily mean ground temperatures (up to 6.5°C) relative to intact forests. In contrast, the relative impact of forest degradation on energy, water, and carbon cycles markedly diminishes under extreme, multiyear droughts, as a consequence of severe stress experienced by intact forests. Our results highlight that the water and energy cycles in the Amazon are driven by not only climate and deforestation but also the past disturbance and changes of forest structure from degradation, suggesting a much broader influence of human land use activities on the tropical ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Mechanistic insights into a heterobifunctional degrader-induced PTPN2/N1 complex

PTPN2 (protein tyrosine phosphatase non-receptor type 2, or TC-PTP) and PTPN1 are attractive immuno-oncology targets, with the deletion of Ptpn1 and Ptpn2 improving response to immunotherapy in disease models. Targeted protein degradation has emerged as a promising approach to drug challenging targets including phosphatases. We developed potent PTPN2/N1 dual heterobifunctional degraders (Cmpd-1 and Cmpd-2) which facilitate efficient complex assembly with E3 ubiquitin ligase CRL4 CRBN , and mediate potent PTPN2/N1 degradation in cells and mice. To provide mechanistic insights into the cooperative complex formation introduced by degraders, we employed a combination of structural approaches. Our crystal structure reveals how PTPN2 is recognized by the tri-substituted thiophene moiety of the degrader. We further determined a high-resolution structure of DDB1-CRBN/Cmpd-1/PTPN2 using single-particle cryo-electron microscopy (cryo-EM). This structure reveals that the degrader induces proximity between CRBN and PTPN2, albeit the large conformational heterogeneity of this ternary complex. The molecular dynamic (MD)-simulations constructed based on the cryo-EM structure exhibited a large rigid body movement of PTPN2 and illustrated the dynamic interactions between PTPN2 and CRBN. Together, our study demonstrates the development of PTPN2/N1 heterobifunctional degraders with potential applications in cancer immunotherapy. Furthermore, the developed structural workflow could help to understand the dynamic nature of degrader-induced cooperative ternary complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resiliency of Degraded Built Infrastructure

Infrastructure resiliency depends on the ability of infrastructure systems to withstand, adapt, and recover from chronic and extreme stresses. In this white paper, we address the resiliency of infrastructure assets and discuss improving infrastructure stability through development of our understanding of cement and concrete degradation. The resiliency of infrastructure during extreme events relies on the condition, adaptability, and recoverability of built infrastructure (roads, bridges, dams), which serves as the backbone of existing infrastructure systems. Much of the built infrastructure in the US has consistently been rated D+ by the American Society of Civil Engineers (ASCE). Aged infrastructure introduces risk to the system, since unreliable infrastructure increases the likelihood of failures under chronic and extreme stress and are particularly concerning when extreme events occur. To understand and account for this added risk from poor infrastructure quality, more research is needed on (i) how the changing environment alters the aging of new and existing built infrastructure and (ii) how degradation causes unique failure mechanisms. The aging of built infrastructure is based on degradation of the structural materials, such as concrete and steel supports, which causes failure. Current work in cement/concrete degradation is based on (i) the development of high strength and degradation resistance concrete mixtures, (ii) methods of assessing the age and reliability of existing structures, and (3) modeling of structural stability and the microstructural evolution of concrete/cement from degradation mechanisms (sulfide attack, carbonation, decalcification). Sandia National Laboratories (SNL) has made several investments in studying the durability and degradation of cement based materials, including using SNL-developed codes and methodologies (peridynamics, PFLOTRAN) to focus on chemo-mechanical fracture of cement for energy applications. Additionally, a recent collaboration with the University of Colorado Boulder has included fracture of concrete gravity dams, scaling the existing work to applications in full sized infrastructure problems. Ultimately, SNL has the experience in degradation of cementitious materials to extend the current research portfolio and answer concerns about the resilience of aging built infrastructure.

36 MATERIALS SCIENCE↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Packages in KAC (2021 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 16 years. The aging environments include elevated temperature up to 250 ºF (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 and non3013 containers in storage from 15 years to 20 years. These calculations addressed the potential for degraded fiberboard properties following 20 years in storage using degradation models developed previously. The updated degradation models developed in this report have been compared to the assumptions in these calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 ºF, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 20 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 20 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of nonconforming conditions such as the presence of excess moisture and mold or beetle infestations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiberboard Properties and Degradation Rates for Storage of 9975 Shipping Package in KAC (2022 Status Report)

Thermal, mechanical, and physical properties have been measured on fiberboard samples following accelerated aging for up to 17 years. The aging environments include elevated temperature up to 250 °F (the maximum allowed service temperature for fiberboard in 9975 packages) and elevated humidity. Accelerated aging results have been analyzed and used to build aging models. Correlations relating several properties (thermal conductivity, energy absorption, weight, dimensions, and density) to their rate of change in potential storage environments have been developed. Combined with an estimate of the actual conditions the fiberboard experiences in K-Area Complex (KAC), these models allow development of service life predictions. KAC completed calculations that supported extending the service life of 9975 packages with 3013 containers in storage from 20 years to 40 years. These calculations addressed the potential for degraded fiberboard properties following 40 years in storage using degradation models developed previously. Due to differences in containers, 9975 packages with non-3013 containers are only approved for 20 years of storage. The updated degradation models developed in this report have been compared to the assumptions in those calculations, and the current results for fiberboard dimensions, density, radial thermal conductivity, and energy absorption remain consistent with those calculations. The axial thermal conductivity degradation rate slightly exceeds calculations estimate of 0.5% per year between 130 and 160 °F. Additional data will continue to be collected to permit future refinements to the models and assumptions. Some of the predicted degradation rates presented in this report are extreme. However, these relate to environments that do not exist within KAC or would be postulated only as upset conditions that would not likely persist for an extended period. For a typical package stored in KAC with approximately 10-12 watts internal heat load or less, and ambient temperatures below 90 °F, the fiberboard assemblies experience storage conditions less severe than any of the aging environments. Fiberboard in conforming packages with lower internal heat loads should experience little or no degradation and is expected to provide a service life beyond the currently approved 40 year storage period. Packages with higher internal heat loads may not continue to perform their required safety functions beyond 40 years. Ultimately, service life will be determined by the cumulative effect of degradation from all the conditions these packages might encounter. The results and model predictions presented in this report are applicable to 9975 packages with cane or softwood fiberboard overpack assemblies. These degradation models do not address the effects of non-conforming conditions such as the presence of excess moisture and mold or beetle infestations.

36 MATERIALS SCIENCE↗

Impacts of the Angular Dependence of the Solar Diffuser BRDF Degradation Factor on the SNPP VIIRS Reflective Solar Band On-Orbit Radiometric Calibration

Using an onboard sunlit solar diffuser (SD) as the primary radiance source, the visible infrared imaging radiometer suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly performs radiometric calibration of its reflective solar bands (RSBs). The SD bidirectional reflectance distribution function (BRDF) value decreases over time. A numerical degradation factor is used to quantify the degradation and is determined by an onboard SD stability monitor (SDSM), which observes the sun and the sunlit SD at almost the same time. We had shown previously that the BRDF degradation factor was angle-dependent. Consequently, due to that the SDSM and the RSB view the SD at very different angles relative to both the solar and the SD surface normal vectors, directly applying the BRDF degradation factor determined by the SDSM to the VIIRS RSB calibration can result in large systematic errors. We develop a phenomenological model to calculate the BRDF degradation factor for the RSB SD view from the degradation factor for the SDSM SD view. Using the yearly undulations observed in the VIIRS detector gains for the M1-M4 bands calculated with the SD BRDF degradation factor for the SDSM SD view and the difference between the VIIRS detector gains calculated from the SD and the lunar observations, we obtain the model parameter values and thus establish the relation between the BRDF degradation factors for the RSB and the SDSM SD view directions.

Lei, Ning↗

Towards Designing Graceful Degradation into Trajectory Based Operations: A Human-Systems Integration Approach

One of the most fundamental changes to the air traffic management system in NextGen is the concept of trajectory based operations (TBO). With the introduction of such change, system safety and resilience is a critical concern, in particular, the ability of systems to gracefully degrade. In order to design graceful degradation into a TBO envrionment, knowledge of the potential causes of degradation, and appropriate solutions, is required. In addition, previous research has predominantly explored the technological contribution to graceful degradation, frequently neglecting to consider the role of the human operator, specifically, air traffic controllers (ATCOs). This is out of step with real-world operations, and potentially limits an ecologically valid understanding of achieving graceful degradation in an air traffic control (ATC) environment. The following literature review aims to identify and summarize the literature to date on the potential causes of degradation in ATC and the solutions that may be applied within a TBO context, with a specific focus on the contribution of the air traffic controller. A framework of graceful degradation, developed from the literature, is presented. It is argued that in order to achieve graceful degradation within TBO, a human-system integration approach must be applied.

human-system integration↗

Towards Designing Graceful Degradation into Trajectory Based Operations: A Human-Machine System Integration Approach

One of the most fundamental changes to the air traffic management system in NextGen is the concept of trajectory based operations (TBO). With the introduction of such change, system safety and resilience is a critical concern, in particular, the ability of systems to gracefully degrade. In order to design graceful degradation into a TBO envrionment, knowledge of the potential causes of degradation, and appropriate solutions, is required. In addition, previous research has predominantly explored the technological contribution to graceful degradation, frequently neglecting to consider the role of the human operator, specifically, air traffic controllers (ATCOs). This is out of step with real-world operations, and potentially limits an ecologically valid understanding of achieving graceful degradation in an air traffic control (ATC) environment. The following literature review aims to identify and summarize the literature to date on the potential causes of degradation in ATC and the solutions that may be applied within a TBO context, with a specific focus on the contribution of the air traffic controller. A framework of graceful degradation, developed from the literature, is presented. It is argued that in order to achieve graceful degradation within TBO, a human-system integration approach must be applied.

human-system integration↗

Quantifying Long-Term Changes in Carbon Stocks and Forest Structure from Amazon Forest Degradation

Despite sustained declines in Amazon deforestation, forest degradation from logging and firecontinues to threaten carbon stocks, habitat, and biodiversity in frontier forests along the Amazon arcof deforestation. Limited data on the magnitude of carbon losses and rates of carbon recoveryfollowing forest degradation have hindered carbon accounting efforts and contributed to incompletenational reporting to reduce emissions from deforestation and forest degradation (REDD+). Wecombined annual time series of Landsat imagery and high-density airborne lidar data to characterizethe variability, magnitude, and persistence of Amazon forest degradation impacts on abovegroundcarbon density (ACD) and canopy structure. On average, degraded forests contained 45.1% of thecarbon stocks in intact forests, and differences persisted even after 15 years of regrowth. Incomparison to logging, understory fires resulted in the largest and longest-lasting differences in ACD.Heterogeneity in burned forest structure varied by fire severity and frequency. Forests with a historyof one, two, and three or more fires retained only 54.4%, 25.2%, and 7.6% of intact ACD,respectively, when measured after a year of regrowth. Unlike the additive impact of successive fires,selective logging before burning did not explain additional variability in modeled ACD loss andrecovery of burned forests. Airborne lidar also provides quantitative measures of habitat structure thatcan aid the estimation of co-benefits of avoided degradation. Notably, forest carbon stocks recoveredfaster than attributes of canopy structure that are critical for biodiversity in tropical forests, includingthe abundance of tall trees. We provide the first comprehensive look-up table of emissions factors forspecific degradation pathways at standard reporting intervals in the Amazon. Estimated carbon lossand recovery trajectories provide an important foundation for assessing the long-term contributionsfrom forest degradation to regional carbon cycling and advance our understanding of the currentstate of frontier forests.

Rappaport, Danielle I.↗

Towards Designing Graceful Degradation into Trajectory Based Operations: A Human-Machine System Integration Approach

One of the most fundamental changes to the air traffic management system in NextGen is the concept of trajectory based operations (TBO). With the introduction of such change, system safety and resilience is a critical concern, in particular, the ability of systems to gracefully degrade. In order to design graceful degradation into a TBO envrionment, knowledge of the potential causes of degradation, and appropriate solutions, is required. In addition, previous research has predominantly explored the technological contribution to graceful degradation, frequently neglecting to consider the role of the human operator, specifically, air traffic controllers (ATCOs). This is out of step with real-world operations, and potentially limits an ecologically valid understanding of achieving graceful degradation in an air traffic control (ATC) environment. The following literature review aims to identify and summarize the literature to date on the potential causes of degradation in ATC and the solutions that may be applied within a TBO context, with a specific focus on the contribution of the air traffic controller. A framework of graceful degradation, developed from the literature, is presented. It is argued that in order to achieve graceful degradation within TBO, a human-system integration approach must be applied.

trajectory based operations↗