Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deformation estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effect of Lumpectomy Cavity Volume Change on the Clinical Target Volume for Accelerated Partial Breast Irradiation: A Deformable Registration Study

Purpose: Previous studies have shown that lumpectomy cavity volumes can change significantly in the weeks following surgery. The effect of this volume change on the surrounding tissue that constitutes the clinical target volume (CTV) for accelerated partial breast irradiation and boost treatment after whole breast irradiation has not been previously studied. In the present study, we used deformable registration to estimate the effect of lumpectomy cavity volume changes on the CTV for accelerated partial breast irradiation and discuss the implications for target construction. Methods and Materials: The data from 13 accelerated partial breast irradiation patients were retrospectively analyzed. Deformable registration was used to propagate contours from the initial planning computed tomography scan to a later computed tomography scan acquired at the start of treatment. The changes in cavity volume and CTV, distance between cavity and CTV contours (i.e., CTV margin), and CTV localization error after cavity registration were determined. Results: The mean {+-} standard deviation change in cavity volume and CTV between the two computed tomography scans was -35% {+-} 23% and -14% {+-} 12%, respectively. An increase in the cavity-to-CTV margin of 2 {+-} 2 mm was required to encompass the CTV, and this increase correlated with the cavity volume change. Because changes in the cavity and CTV were not identical, a localization error of 2-3 mm in the CTV center of mass occurred when the cavity was used as the reference for image guidance. Conclusion: Deformable registration suggested that CTV margins do not remain constant as the cavity volume changes. This finding has implications for planning target volume and CTV construction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Theoretical Operational Model for Complex Experiments and its Invariance Theorems

We develop and systematize the Theoretical–Operational Model (TOM), a framework that treats preparation and measurement —including their operational residues— as intrinsic structures of physical theory. The central contribution is a principled geometric–algebraic organization of admissible operational deformations, formulated using quantum channels, renormalization-style flows, and information-geometric tools. Within this structure, operational residues and background processes are represented as effective morphisms attached to these operational components, whose invariants yield constraints on how theoretical parameters vary under specified classes of deformations. Illustrations drawn from muon–electron conversion, long-baseline neutrino oscillations, and quark–gluon-plasma phenomenology show how TOM maps operational effects into inferences about theoretical parameters, enables systematic cross-experimental comparisons, and stabilizes parameter estimation against defined deformation families. By embedding the operational layer—together with its residues—within a structured theoretical setting, TOM supports both theory testing and theory development, clarifying the conceptual relation between experimental realization and the physical quantities represented by the theory.

Pronskikh, Vitaly [Fermilab] (ORCID:00000002518174↗

Vertical deformation at western part of Sumatra

This research tries to make advancement in GPS signal processing to estimate the interseismic vertical deformation field at western part of Sumatra Island. The data derived by Continuous Global Positioning System (CGPS) from Badan Informasi Geospasial (BIG) between 2010 and 2012. GPS Analyze at Massachusetts Institute of Technology (GAMIT) software and Global Kalman Filter (GLOBK) software are used to process the GPS signal to estimate the vertical velocities of the CGPS station. In order to minimize noise due to atmospheric delay, Vienna Mapping Function 1 (VMF1) is used as atmospheric parameter model and include daily IONEX file provided by the Center for Orbit Determination in Europe (CODE) as well. It improves GAMIT daily position accuracy up to 0.8 mm. In a second step of processing, the GLOBK is used in order to estimate site positions and velocities in the ITRF08 reference frame. The result shows that the uncertainties of estimated displacement velocity at all CGPS stations are smaller than 1.5 mm/yr. The subsided deformation patterns are seen at the northern and southern part of west Sumatra. The vertical deformation at northern part of west Sumatra indicates postseismic phase associated with the 2010 and 2012 Northern Sumatra earthquakes and also the long-term postseismic associated with the 2004 and 2005 Northern Sumatra earthquakes. The uplifted deformation patterns are seen from Bukit Tinggi to Seblat which indicate a long-term interseismic phase after the 2007 Bengkulu earthquake and 2010 Mentawai earthquake. GANO station shows a subsidence at rate 12.25 mm/yr, indicating the overriding Indo-Australia Plate which is dragged down by the subducting Southeast Asian Plate.

58 GEOSCIENCES↗

Stochastic formulation of patient positioning using linac-mounted cone beam imaging with prior knowledge

Purpose: In this work, a novel stochastic framework for patient positioning based on linac-mounted CB projections is introduced. Based on this formulation, the most probable shifts and rotations of the patient are estimated, incorporating interfractional deformations of patient anatomy and other uncertainties associated with patient setup. Methods: The target position is assumed to be defined by and is stochastically determined from positions of various features such as anatomical landmarks or markers in CB projections, i.e., radiographs acquired with a CB-CT system. The patient positioning problem of finding the target location from CB projections is posed as an inverse problem with prior knowledge and is solved using a Bayesian maximum a posteriori (MAP) approach. The prior knowledge is three-fold and includes the accuracy of an initial patient setup (such as in-room laser and skin marks), the plasticity of the body (relative shifts between target and features), and the feature detection error in CB projections (which may vary depending on specific detection algorithm and feature type). For this purpose, MAP estimators are derived and a procedure of using them in clinical practice is outlined. Furthermore, a rule of thumb is theoretically derived, relating basic parameters of the prior knowledge (initial setup accuracy, plasticity of the body, and number of features) and the parameters of CB data acquisition (number of projections and accuracy of feature detection) to the expected estimation accuracy. Results: MAP estimation can be applied to arbitrary features and detection algorithms. However, to experimentally demonstrate its applicability and to perform the validation of the algorithm, a water-equivalent, deformable phantom with features represented by six 1 mm chrome balls were utilized. These features were detected in the cone beam projections (XVI, Elekta Synergy) by a local threshold method for demonstration purposes only. The accuracy of estimation (strongly varying for different plasticity parameters of the body) agreed with the rule of thumb formula. Moreover, based on this rule of thumb formula, about 20 projections for 6 detectable features seem to be sufficient for a target estimation accuracy of 0.2 cm, even for relatively large feature detection errors with standard deviation of 0.5 cm and spatial displacements of the features with standard deviation of 0.5 cm. Conclusions: The authors have introduced a general MAP-based patient setup algorithm accounting for different sources of uncertainties, which are utilized as the prior knowledge in a transparent way. This new framework can be further utilized for different clinical sites, as well as theoretical developments in the field of patient positioning for radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron decay width of one-particle resonant levels in deformed nuclei

The neutron partial decay width of one-particle resonant levels that are the bandhead states in odd-N deformed nuclei is estimated in the formalism with a real-energy variable, using the width of one-particle resonance calculated in terms of eigenphase. It is shown that because of the presence of various (lj) components in a given one-particle resonant level of deformed nuclei, the neutron decay width can be quite different from the one obtained from assuming a spherically symmetric nuclear shape. As a numerical example, the formalism is applied to the case of the nucleus {sub 4}{sup 13}Be{sub 9}, which lies outside the neutron drip line by 100-200 keV. Considering that the core of the nucleus consisting of four protons and eight neutrons is most likely prolately deformed, we point out the possibility that two lowest lying levels have I{sup {pi}}=1/2{sup +} for the N=9 nucleus, and the higher lying one may have a neutron decay width that is much narrower than the one expected for an s{sub 1/2} level at the same resonance energy. The structure of some {omega}{sup {pi}}=1/2{sup +} one-particle resonant levels, which are smoothly connected to weakly bound one-particle levels as the potential strength becomes stronger, is also analyzed using the present formalism.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Localization of deformable tumors from short-arc projections using Bayesian estimation

Purpose: The authors present a stochastic framework for radiotherapy patient positioning directly utilizing radiographic projections. This framework is developed to be robust against anatomical nonrigid deformations and to cope with challenging imaging scenarios, involving only a few cone beam CT projections from short arcs. Methods: Specifically, a Bayesian estimator (BE) is explicitly derived for the given scanning geometry. This estimator is compared to reference methods such as chamfer matching (CM) and the minimization of the median absolute error adapted as tools of robust image processing and statistics. In order to show the performance of the stochastic short-arc patient positioning method, a CIRS IMRT thorax phantom study is presented with movable markers and the utilization of an Elekta Synergy{sup Registered-Sign} XVI system. Furthermore, a clinical prostate CBCT scan of a Varian{sup Registered-Sign} On-Board Imager{sup Registered-Sign} system is utilized to investigate the robustness of the method for large variations of image quality (anterior-posterior vs lateral views). Results: The results show that the BE shifts reduce the initial setup error of up to 3 cm down to 3 mm at maximum for an imaging arc as short as 10 Degree-Sign while CM achieves residual errors of 7 mm at maximum only for arcs longer than 40 Degree-Sign . Furthermore, the BE can compensate robustly for low image qualities using several low quality projections simultaneously. Conclusions: In conclusion, an estimation method for marker-based patient positioning for short imaging arcs is presented and shown to be robust and accurate for deformable anatomies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformation mechanism in nanolaminate FeCrAl alloys by ,em>in situ micromechanical strain rate jump tests at elevated temperatures

FeCrAl alloys have attracted extensive attention as one of the potential cladding materials for the commercial light water reactors. Although the creep behaviors of coarse-grain FeCrAl alloys have been investigated at elevated temperatures, little is known on the deformation mechanism of fine-grain FeCrAl alloys. We performed surface mechanical grinding treatment to fabricate nanolaminated ferritic FeCrAl alloys. In situ micropillar compression tests were applied to determine the underlying deformation mechanism of nanolaminated FeCrAl alloys at elevated temperatures. The strain rate sensitivity and activation energy for the dominant deformation mechanism were estimated considering the presence of a threshold stress.

36 MATERIALS SCIENCE↗

Photoinduced Reversible Local Deformation of the Surface Relief in Bulk Single Crystals of TlInSe{sub 2}, TlGaTe{sub 2}, and TlSe

Giant macroscopic expansion of the surface relief, localized within a laser spot size, has been observed in bulk single crystals of TlInSe{sub 2}, TlGaTe{sub 2}, and TlSe at room temperature and laser radiation densities lower by at least two orders of magnitude than the material optical damage threshold. Quantitative estimations of the deformation magnitude in this local region were obtained using an interference dilatometer. The photon absorption length was determined with the aid of spectroscopic ellipsometry. It is established that the surface deformation amounts to 2.6 × 10{sup –3} at a laser radiation intensity of 19 mW/mm{sup 2}. The observed phenomenon has a thermal nature and is probably related to a low thermal conductivity of the materials studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying the effect of late bombardment on terrestrial zircons

The first 500 million years of Earth history is thought to be a period of intense planetary bombardment, but the timing and flux of this meteorite bombardment is poorly understood. In particular, on the basis of an inferred lunar impact history, some workers have hypothesized a ~3.9 Ga terminal cataclysm (TC) in which there was marked increase in the impact flux affecting the Moon, the Earth and possibly other terrestrial planets. Minerals that survived this enigmatic period offer a way to test early planetary bombardment models as they may contain telltale micro- to nanoscale shock features. Here, we present results from a numerical modeling calculation that assesses the probability that a zircon residing in the crust would escape shock melting or shock deformation during a TC bombardment event. Even with conservative pressure estimates for zircon shock deformation and intermediate bombardment intensities, we find that only ~6% of ≥4.0 Ga crust would be expected to survive a 3.9 Ga cataclysm without experiencing either complete melting or zircon shock metamorphism. In this study, we couple this modeling with a search for shock effects in the oldest zircons from the Acasta Gneiss Complex, which would have been present in the Earth's crust during a putative 3.9 Ga TC. Spatially correlated electron and NanoSIMS ion microscopy of 4.02 Ga igneous zircons from Acasta reveals no evidence of ancient shock. These data, together with similar results from other Hadean zircon suites, confirm that a post-Hadean TC is unlikely to have occurred. We suggest that the dearth of pre-3.9 Ga terrestrial crust and zircons is instead best explained by endogenic processes related to the mechanisms of early crust formation. Our modeling allows us to evaluate bombardment scenarios from the terrestrial zircon record by applying probabilistic interpretations to zircon shock deformation data. This approach will be valuable for other planetary bodies, allowing broader conclusions to be drawn from geographically limited datasets.

58 GEOSCIENCES↗

SU-E-J-44: A Novel Approach to Quantify Patient Setup and Target Motion for Real-Time Image-Guided Radiotherapy (IGRT)

Purpose Isocenter shifts and rotations to correct patient setup errors and organ motion cannot remedy some shape changes of large targets. We are investigating new methods in quantification of target deformation for realtime IGRT of breast and chest wall cancer. Methods Ninety-five patients of breast or chest wall cancer were accrued in an IRB-approved clinical trial of IGRT using 3D surface images acquired at daily setup and beam-on time via an in-room camera. Shifts and rotations relating to the planned reference surface were determined using iterative-closest-point alignment. Local surface displacements and target deformation are measured via a ray-surface intersection and principal component analysis (PCA) of external surface, respectively. Isocenter shift, upper-abdominal displacement, and vectors of the surface projected onto the two principal components, PC1 and PC2, were evaluated for sensitivity and accuracy in detection of target deformation. Setup errors for some deformed targets were estimated by superlatively registering target volume, inner surface, or external surface in weekly CBCT or these outlines on weekly EPI. Results Setup difference according to the inner-surface, external surface, or target volume could be 1.5 cm. Video surface-guided setup agreed with EPI results to within < 0.5 cm while CBCT results were sometimes (∼20%) different from that of EPI (>0.5 cm) due to target deformation for some large breasts and some chest walls undergoing deep-breath-hold irradiation. Square root of PC1 and PC2 is very sensitive to external surface deformation and irregular breathing. Conclusion PCA of external surfaces is quick and simple way to detect target deformation in IGRT of breast and chest wall cancer. Setup corrections based on the target volume, inner surface, and external surface could be significant different. Thus, checking of target shape changes is essential for accurate image-guided patient setup and motion tracking of large deformable targets. NIH grant for the first author as cionsultant and the last author as the PI.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-11: Implanted Brachytherapy Seed Movement Due to Transrectal Ultrasound Probe-Induced Prostate Deformation

Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogate urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset of peripheral seeds involved, but lateral shearing movement can have greater consequences for local dose coverage.

60 APPLIED LIFE SCIENCES↗

A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map

We developed a novel digital tomosynthesis (DTS) reconstruction method using a deformation field map to optimally estimate volumetric information in DTS images. The deformation field map is solved by using prior information, a deformation model, and new projection data. Patients' previous cone-beam CT (CBCT) or planning CT data are used as the prior information, and the new patient volume to be reconstructed is considered as a deformation of the prior patient volume. The deformation field is solved by minimizing bending energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. The new patient DTS volume is then obtained by deforming the prior patient CBCT or CT volume according to the solution to the deformation field. This method is novel because it is the first method to combine deformable registration with limited angle image reconstruction. The method was tested in 2D cases using simulated projections of a Shepp-Logan phantom, liver, and head-and-neck patient data. The accuracy of the reconstruction was evaluated by comparing both organ volume and pixel value differences between DTS and CBCT images. In the Shepp-Logan phantom study, the reconstructed pixel signal-to-noise ratio (PSNR) for the 60 deg. DTS image reached 34.3 dB. In the liver patient study, the relative error of the liver volume reconstructed using 60 deg. projections was 3.4%. The reconstructed PSNR for the 60 deg. DTS image reached 23.5 dB. In the head-and-neck patient study, the new method using 60 deg. projections was able to reconstruct the 8.1 deg. rotation of the bony structure with 0.0 deg. error. The reconstructed PSNR for the 60 deg. DTS image reached 24.2 dB. In summary, the new reconstruction method can optimally estimate the volumetric information in DTS images using 60 deg. projections. Preliminary validation of the algorithm showed that it is both technically and clinically feasible for image guidance in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-92: Validating Dose Uncertainty Estimates Produced by AUTODIRECT, An Automated Program to Evaluate Deformable Image Registration Accuracy

Purpose: Deformable image registration (DIR) is a powerful tool with the potential to deformably map dose from one computed-tomography (CT) image to another. Errors in the DIR, however, will produce errors in the transferred dose distribution. We have proposed a software tool, called AUTODIRECT (automated DIR evaluation of confidence tool), which predicts voxel-specific dose mapping errors on a patient-by-patient basis. This work validates the effectiveness of AUTODIRECT to predict dose mapping errors with virtual and physical phantom datasets. Methods: AUTODIRECT requires 4 inputs: moving and fixed CT images and two noise scans of a water phantom (for noise characterization). Then, AUTODIRECT uses algorithms to generate test deformations and applies them to the moving and fixed images (along with processing) to digitally create sets of test images, with known ground-truth deformations that are similar to the actual one. The clinical DIR algorithm is then applied to these test image sets (currently 4) . From these tests, AUTODIRECT generates spatial and dose uncertainty estimates for each image voxel based on a Student’s t distribution. This work compares these uncertainty estimates to the actual errors made by the Velocity Deformable Multi Pass algorithm on 11 virtual and 1 physical phantom datasets. Results: For 11 of the 12 tests, the predicted dose error distributions from AUTODIRECT are well matched to the actual error distributions within 1–6% for 10 virtual phantoms, and 9% for the physical phantom. For one of the cases though, the predictions underestimated the errors in the tail of the distribution. Conclusion: Overall, the AUTODIRECT algorithm performed well on the 12 phantom cases for Velocity and was shown to generate accurate estimates of dose warping uncertainty. AUTODIRECT is able to automatically generate patient-, organ- , and voxel-specific DIR uncertainty estimates. This ability would be useful for patient-specific DIR quality assurance.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Pair-Wise, Deformable Mirror, Image Plane-Based Diversity Electric Field Estimation for High Contrast Coronagraphy

In this paper we describe the complex electric field reconstruction from image plane intensity measurements for high contrast coronagraphic imaging. A deformable mirror (DM) surface is modied with pairs of complementary shapes to create diversity in the image plane of the science camera where the intensity of the light is measured. Along with the Electric Field Conjugation correction algorithm, this estimation method has been used in various high contrast imaging testbeds to achieve the best contrasts to date both in narrow and in broad band light. We present the basic methodology of estimation in easy to follow list of steps, present results from HCIT and raise several open quations we are confronted with using this method.

coronagraphy↗

Are Neutron Stars with Crystalline Color-Superconducting Cores Relevant for the LIGO Experiment?

We estimate the maximal deformation that can be sustained by a rotating neutron star with a crystalline color-superconducting quark core. Our results suggest that current gravitational-wave data from the Laser Interferometer Gravitational-Wave Observatory have already reached the level where a detection would have been possible over a wide range of the poorly constrained QCD parameters. This leads to the nontrivial conclusion that compact objects do not contain maximally strained color crystalline cores drawn from this range of parameter space. We discuss the uncertainties associated with our simple model and how it can be improved in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-AB-303-09: Rapid Projection Computations for On-Board Digital Tomosynthesis in Radiation Therapy

Purpose: To facilitate fast and accurate iterative volumetric image reconstruction from limited-angle on-board projections. Methods: Intrafraction motion hinders the clinical applicability of modern radiotherapy techniques, such as lung stereotactic body radiation therapy (SBRT). The LIVE system may impact clinical practice by recovering volumetric information via Digital Tomosynthesis (DTS), thus entailing low time and radiation dose for image acquisition during treatment. The DTS is estimated as a deformation of prior CT via iterative registration with on-board images; this shifts the challenge to the computational domain, owing largely to repeated projection computations across iterations. We address this issue by composing efficient digital projection operators from their constituent parts. This allows us to separate the static (projection geometry) and dynamic (volume/image data) parts of projection operations by means of pre-computations, enabling fast on-board processing, while also relaxing constraints on underlying numerical models (e.g. regridding interpolation kernels). Further decoupling the projectors into simpler ones ensures the incurred memory overhead remains low, within the capacity of a single GPU. These operators depend only on the treatment plan and may be reused across iterations and patients. The dynamic processing load is kept to a minimum and maps well to the GPU computational model. Results: We have integrated efficient, pre-computable modules for volumetric ray-casting and FDK-based back-projection with the LIVE processing pipeline. Our results show a 60x acceleration of the DTS computations, compared to the previous version, using a single GPU; presently, reconstruction is attained within a couple of minutes. The present implementation allows for significant flexibility in terms of the numerical and operational projection model; we are investigating the benefit of further optimizations and accurate digital projection sub-kernels. Conclusion: Composable projection operators constitute a versatile research tool which can greatly accelerate iterative registration algorithms and may be conducive to the clinical applicability of LIVE. National Institutes of Health Grant No. R01-CA184173; GPU donation by NVIDIA Corporation.

60 APPLIED LIFE SCIENCES↗