Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data depth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-E-T-790: Validation of 4D Measurement-Guided Dose Reconstruction (MGDR) with OCTAVIUS 4D System

Purpose: To validate the MGDR of OCTAVIUS 4D system (PTW, Freiburg, Germany) for quality assurance (QA) of volumetric-modulated arc radiotherapy (VMAT). Methods: 4D-MGDR measurements were divided into two parts: 1) square fields from 2×2 to 25×25 cm{sup 2} at 0°, 10° and 45° gantry, and 2) 8 VMAT plans (5 nasopharyngeal and 3 prostate) collapsed to gantry 40° in QA mode in Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on the OCTAVIUS 4D phantom with the OCTAVIUS 1500 detector plane perpendicular to either the incident beam to obtain the reconstructed dose (OCTA4D) or the 0° gantry axis to obtain the raw doses (OCTA3D) in Verisoft 6.1 (PTW, Freiburg, Germany). Raw measurements of OCTA3D were limited to < 45° gantry to avoid >0.5% variation of detector angular response with respect to 0° gantry as determined previously. Reconstructed OCTA4D and raw OCTA3D doses for all plans were compared at the same detector plane using γ criteria of 2% (local dose)/2mm and 3%/3mm criteria. Results: At gantry 0° and 10°, the γ results for all OCTA4D on detector plane coinciding with OCTA3D were over 90% at 2%/2mm except for the largest field (25×25 cm{sup 2} ) showing >88%. For square field at 45° gantry, γ passing rate is > 90% for fields smaller than 15x 15cm2 but < 80% for field size of 20 x20 cm{sup 2} upward. For VMAT, γ results showed 94% and 99% passing rate at 2%/2mm and 3%/3mm, respectively. Conclusion: OCTAVIUS 4D system has compromised accuracy in reconstructing dose away from the central beam axis, possibly due to the off-axis softening correction and errors of the percent depth dose data necessary as input for MGDR. Good results in VMAT delivery suggested that the system is relatively reliable for VMAT with small segments.

60 APPLIED LIFE SCIENCES↗

Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams

Purpose: There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for flattening filter free (FFF) beams, the relationship between the beam-quality specifier TPR{sub 20,10} and the Spencer–Attix restricted water-to-air mass collision stopping-power ratios, (L{sup -}/ρ){sub air}{sup water}, may have to be refined in order to be used with equivalent accuracy as for beams with a flattening filter. The purpose of this work was twofold. First, to study the relationship between TPR{sub 20,10} and (L{sup -}/ρ){sub air}{sup water} for FFF beams, where the flattening filter has been replaced by a metal plate as in most clinical FFF beams. Second, to investigate the potential of increasing the accuracy in determining (L{sup -}/ρ){sub air}{sup water} by adding another beam-quality metric, TPR{sub 10,5}. The relationship between (L{sup -}/ρ){sub air}{sup water} and %dd(10){sub x} for beams with and without a flattening filter was also included in this study. Methods: A total of 24 realistic photon beams (10 with and 14 without a flattening filter) from three different treatment units have been used to calculate (L{sup -}/ρ){sub air}{sup water}, TPR{sub 20,10}, and TPR{sub 10,5} using the EGSnrc Monte Carlo package. The relationship between (L{sup -}/ρ){sub air}{sup water} and the dual beam-quality specifier TPR{sub 20,10} and TPR{sub 10,5} was described by a simple bilinear equation. The relationship between the photon beam-quality specifier %dd(10){sub x} used in the AAPM’s TG-51 dosimetry protocol and (L{sup -}/ρ){sub air}{sup water} was also investigated for the beams used in this study, by calculating the photon component of the percentage depth dose at 10 cm depth with SSD 100 cm. Results: The calculated (L{sup -}/ρ){sub air}{sup water} for beams without a flattening filter was 0.3% lower, on average, than for beams with a flattening filter and comparable TPR{sub 20,10}. Using the relationship in IAEA, TRS-398 resulted in a root mean square deviation (RMSD) of 0.0028 with a maximum deviation of 0.0043 (0.39%) from Monte Carlo calculated values. For all beams in this study, the RMSD between the proposed model and the Monte Carlo calculated values was 0.0006 with a maximum deviation of 0.0013 (0.1%). Using an earlier proposed relationship [Xiong and Rogers, Med. Phys. 35, 2104–2109 (2008)] between %dd(10){sub x} and (L{sup -}/ρ){sub air}{sup water} gave a RMSD of 0.0018 with a maximum deviation of 0.0029 (0.26%) for all beams in this study (compared to RMSD 0.0015 and a maximum deviation of 0.0048 (0.47%) for the relationship used in AAPM TG-51 published by Almond et al. [Med. Phys. 26, 1847–1870 (1999)]). Conclusions: Using TPR{sub 20,10} as a beam-quality specifier, for the flattening filter free beams used in this study, gave a maximum difference of 0.39% between (L{sup -}/ρ){sub air}{sup water} predicted using IAEA TRS-398 and Monte Carlo calculations. An additional parameter for determining (L{sup -}/ρ){sub air}{sup water} has been presented. This parameter is easy to measure; it requires only an additional dose measurement at 5 cm depth with SSD 95 cm, and provides information for accurate determination of the (L{sup -}/ρ){sub air}{sup water} ratio for beams both with and without a flattening filter at the investigated energies.

07 ISOTOPE AND RADIATION SOURCES↗

EGS Collab Experiment 1: 4850L Downhole Camera Surveys During Injection

This package includes data and footage from two rounds of downhole camera surveys performed at the Sanford Underground Research Facility (SURF) on the 4850 level. The exercise was performed once on 25 May 2018 and once on 21 December 2018. On May 25th, the first round was done during fluid injection at the 164-ft stimulation zone in the injection well (E1-I). On December 21st, the second round was carried out during fluid injection at the 142-ft stimulation zone. Prior to the injections, downhole instrumentation was removed from the production well (E1-P) to allow room for the downhole camera system. The water within E1-P was then lifted out by the application of air pressure and the downhole camera system was conveyed into the production well. Finally, the water was injected into E1-I and the camera was used to scan for jetting points, or fluid entry, in E1-P. There is a survey description in this package that further describes the procedure of the survey and the overall results. Additionally, there is a detailed analysis of the surveys in the form of a PowerPoint, which includes animations/visualizations from the camera footage, presents interpretations in detail, and provides some general conclusions. Three animations, along with the two video segments that show the jetting into E1-P, are also provided. The video footage was collected using a GeoVISION Dual-Scan Micro Video Camera, the specs of which are also included in this package as a resource.

15 GEOTHERMAL ENERGY↗

SU-E-T-191: Commissioning and Dosimetric Characteristics of Elekta Agility for Total Skin Electron Beam (TSEB) Therapy

Purpose The purpose of this work is to publish beam data from Elekta Synergy(R) linear accelerators with Agility(TM) MLC for total skin electron beam (TSEB) therapy using the HDRE1 (High Dose Rate Electron 6MeV) energy. Method & Materials The optimal gantry angles for TSEB were determined using ion chamber measurements along a vertical profile at 450cm SSD. After gantry angles were chosen, field uniformity was measured over the entire treatment area. Uniformity was measured with and without the patient support device, allowing the dosimetric effect of the support device to be determined. Beam output and PDD were measured at the calibration point (450cm SSD) for a dual beam using a parallel plate chamber in solid water. These measurements were repeated with the chamber and phantom rotated about the patient isocenter at various angles, in order to measure the contribution from oblique beams. This technique provides a precise measurement of the treatment skin dose (TSD). Lastly, ion chamber measurements were verified by film and diodes. Results The optimal gantry angle for 450 cm SSD was determined to be 90±16°. This achieved uniformity better than 96% on the vertical axis, and 92% along the horizontal axis. HDRE1 was calibrated to deliver 10 cGy/MU at standard geometry (100 cm SSD, 1.2 cm depth). Thus at TSEB geometry (450 cm SSD, 0.1 cm depth) the output of the AP dual field was measured to be 0.35 cGy/MU. The TSD of a 20 cm radius cylinder for six (equally, 60° spaced) dual fields was measured to be 1.19 cGy/MU. Percent Depth Dose data for the AP dual field and TSD are shown in Figure 2. Conclusion This paper provides a modern procedure for commissioning TSEB therapy on a linear accelerator, and clinical beam data for the Elekta Synergy(R) with Agility(TM) MLC.

60 APPLIED LIFE SCIENCES↗

Dissolved pyrogenic carbon leaching in soil: Effects of soil depth and pyrolysis temperature

We report Pyrogenic organic carbon (PyC) is found in soils as a heterogeneous mixture of thermally altered plant residues that range in their susceptibility to losses via mineralization, leaching, and erosion. Leaching of PyC as DOC (DPyC) within the soil profile is likely influenced by the chemical composition of solid PyC and the dominant soil processes and properties at a particular depth. Here we report the results of a 2-year laboratory decomposition and leaching study designed to investigate the interactive effects of pyrolysis temperature levels (no pyrolysis, 300 °C, and 450 °C) and soil depth (surface soil, 0–10 cm depth; subsurface soil, 50–70 cm depth) on losses of 13 C-labeled jack pine (Pinus banksiana) wood, wood pyrolyzed at 300 °C (PyC300) and wood pyrolyzed at 450 °C (PyC450) as dissolved organic carbon (DOC). Losses of wood and PyC in the 13 C- DOC pool were measured in leachates drained from soils once a month over the course of 1 year, and at one single leaching event after 2 years. We found that pyrolysis temperature levels interacted with time and soil depth to affect losses of wood and PyC as DOC throughout the 1-year incubation and leaching study, with greater DOC losses from wood in surface soil (0.73 ± 0.076% of added C) than in subsurface soil (0.40 ± 0.063% of added C) averaged across sampling time. Monthly DOC losses from PyC were not affected by soil depth. Cumulative data indicated a small contribution of wood (2.86 ± 0.07%), PyC300 (0.40 ± 0.04%), and PyC450 (0.16 ± 0.01%) to total DOC leached from soils. DOC losses from wood and PyC300 (as a proportion of added C) were greater in surface soil than in subsurface soil, whereas DOC losses from PyC450 were unaffected by differences between surface and subsurface soil. Losses of DOC were greater from PyC300 than from PyC450 in surface soil, with no significant differences in DOC losses between PyC300 and PyC450 in subsurface soil. One single leaching event at the end of the 2-year decomposition study resulted in higher DOC losses from wood in subsurface soil than in surface soil likely due to desorption, and no differences in DOC losses between PyC300 and PyC450 regardless of soil depth. Our results suggest strong interactions between the initial physicochemical composition of organic C inputs and soil properties (soil depth as a proxy) that control the mobility and transport of PyC and should be better represented in Earth system models.

54 ENVIRONMENTAL SCIENCES↗

16s Amplicon Analysis of Soil Data for Interactive effects of depth and differential irrigation on soil microbiome composition and functioning

Genomic DNA was isolated from soil and rhizosphere samples using the Zymo Quick-DNA fecal/soil microbe miniprep kit (catalog no. D6010) according to the manufacturer’s instructions (Zymo Research; Irvine, CA) with the modification of eluting in 100 uL elution buffer. Sample concentrations were quantified using the Qubit dsDNA HS assay kit (Thermo Fisher). For rhizosphere samples only, DNA was subsequently purified using Zymo’s ZR-96 DNA Clean & Concentrator kit (catalog no. D4024) to account for low DNA concentrations of these samples. . In each replicate block, there were five drip irrigation treatments (T1 = 100% normal irrigation, T2 = 56.25%, T3 = 37.5%, T4 = 18.75% and T5=no irrigation. On July 20, the strength of the drought treatments was increased: T1 remained at 100%, whereas T2 changed from 75% to 56.25%, T2 changed from 50% to 37.5%, and T4 changed from 25% to 18.75%. Sequencing was performed as described previously (Naylor, Fansler, et al. 2020). Sequences were amplified on the MiSeq platform (Illumina, San Diego, CA) using 16S primers (515F and 806R) specific to the V4 region. Raw sequence data was processed with the pipeline Hundo for amplicon quality control and annotation. Downstream statistical analyses on 16S datasets were performed using the program R and the packages ‘phyloseq’ and ‘vegan’.

Soil microbiome, metatranscriptomics↗

SPRUCE Climate Warming and Elevated CO2 Rapidly Alter Peatland Soil Carbon Sources and Stability: Supporting Data

This data set reports a suite of complementary biogeochemical analyses of peat samples from the SPRUCE (Spruce and Peatland Responses Under Changing Environments) experiment. Results were collected using quantitative molecular analysis of bulk soil carbon to assess the stability of soil organic carbon following whole-ecosystem warming and exposure to elevated carbon dioxide concentrations (eCO2). Targeted soil organic carbon components include solvent-extractable compounds (alkanoic acids, alkanols, alkanes, steroids, and terpenoids), ester-bound hydrolysable biopolymers (cutin and suberin markers), lignin phenols, and pyrogenic carbon. Bulk peat samples were analysed by Soxhlet extraction and solid phase separation for solvent-extractable compounds, alkaline hydrolysis to extract hydrolysable biopolymers, copper (II) oxide oxidation to extract lignin phenols and benzene polycarboxylic acids (BPCAs) as an approximation of pyrogenic carbon. Samples were analysed by gas chromatography (GC) equipped with a flame ionization detector (GC-FID) and compound identification was performed on GC coupled to mass selective detector (MS) for solvent-extractable compounds, ester-bound hydrolysable biopolymers and lignin phenols, and high-performance liquid chromatograph (HPLC) for pyrogenic carbon. Results are presented in Ofiti et al. (accepted). The experimental work was conducted on samples collected in August 2018 at the SPRUCE climate manipulation experiment in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF). Samples were collected and later analysed in a 10 cm increments over 0 to 50 cm depth and 25 cm intervals from 50 to 75 cm. Samples were analyzed for lignin phenols over 0 to 30 cm depth. This data set contains one file in comma separate (*.csv) format. This dataset contains data used to produce: Ofiti, N.O.E., Schmidt, M.W.I., Abiven, S., Hanson, P.J., Iversen, C.M., Wilson, R.M., Kostka, J.E., Wiesenberg, G.L.B., Malhotra, A. 2023. Climate warming and elevated CO2 rapidly alter peatland soil carbon sources and stability. Nat Commun 14, 7533. https://doi.org/10.1038/s41467-023-43410-z.

SPRUCE experiment, Marcell Experimental Forest, so↗

Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRE-02: Characterization of a New Commercial Single Crystal Diamond Detector in Photon, Electron and Proton Beams

Purpose: Diamond detectors even with superior characteristics have become obsolete due to poor design, selection of crystal and cost. Recently, microDiamond using synthetic single crystal diamond detector (SCDD) is commercially available which is characterized in various radiation beams in this study. Methods: The characteristics of a commercial SCDD model 60019 (PTW) to a 6- and 15-MV photon beams, 6- and 20-MeV electron beams, and 208 MeV proton beams were investigated and compared to the pre-characterized detectors: TN31010 (0.125 cm{sup 3}) and TN30006 (pinpoint) ionization chambers (PTW), EDGE detector (Sun Nuclear Corp), and SFD Stereotactic Dosimetry Diode Detector (IBA). The depth-dose and profiles data were collected for various field sizes and depths. The dose linearity and dose rate dependency were also evaluated. To evaluate the effects of the preirradiation, the diamond detector which had not been irradiated on the day was set up in the water tank and the response to 100 MU was measured every 20 s. The temperature dependency was tested for the range of 4–60 °C. Angular dependency was evaluated in water phantom by rotating the SCDD. Results: For all radiation types and field sizes, the depth-dose data of the diamond chamber showed identical curve to those of ionization chambers. The profile of the diamond detector was very similar to those of the Edge and SFD detectors, although the 0.125 cm{sup 3} and pinpoint chambers showed averaging effects in the penumbrae region. The temperature dependency was within 0.7% in the range of 4–41°C. A dose of 900 cGy and 1200 cGy were needed to stabilize the chamber to the level within 0.5% and 0.2%, respectively. Conclusion: The type 60019 SCDD detector showed suitable characteristics for depth-dose and profile measurements for wide range of field sizes. However, at least 1000 cGy of pre-irradiation is needed for accurate measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Assembly and comparative genome analysis of a Patagonian Aureobasidium pullulans isolate reveals unexpected intraspecific variation

Aureobasidium pullulans is a yeast-like fungus with remarkable phenotypic plasticity widely studied for its importance for the pharmaceutical and food industries. So far, genomic studies with strains from all over the world suggest they constitute a genetically unstructured population, with no association by habitat. However, the mechanisms by which this genome supports so many phenotypic permutations are still poorly understood. Recent works have shown the importance of sequencing yeast genomes from extreme environments to increase the repertoire of phenotypic diversity of unconventional yeasts. In this study, we present the genomic draft of A. pullulans strain from a Patagonian yeast diversity hotspot, re-evaluate its taxonomic classification based on taxogenomic approaches, and annotate its genome with high-depth transcriptomic data. Here, our analysis suggests this isolate could be considered a novel variant at an early stage of the speciation process. The discovery of divergent strains in a genomically homogeneous group, such as A. pullulans, can be valuable in understanding the evolution of the species. The identification and characterization of new variants will not only allow finding unique traits of biotechnological importance, but also optimize the choice of strains whose phenotypes will be characterized, providing new elements to explore questions about plasticity and adaptation.

59 BASIC BIOLOGICAL SCIENCES↗

Overview of SIMS-Based Experimental Studies of Tracer Diffusion in Solids and Application to Mg Self-Diffusion

Tracer diffusivities provide the most fundamental information on diffusion in materials and are the foundation of robust diffusion databases. Compared to traditional radiotracer techniques that utilize radioactive isotopes, the secondary ion mass spectrometry (SIMS) based thin-film technique for tracer diffusion is based on the use of enriched stable isotopes that can be accurately profiled using SIMS. Experimental procedures & techniques that are utilized for the measurement of tracer diffusion coefficients are presented for pure magnesium, which presents some unique challenges due to the ease of oxidation. The development of a modified Shewmon-Rhines diffusion capsule for annealing Mg and an ultra-high vacuum (UHV) system for sputter deposition of Mg isotopes are discussed. Optimized conditions for accurate SIMS depth profiling in polycrystalline Mg are provided. An automated procedure for the correction of heat-up and cool-down times during tracer diffusion annealing is discussed. The non-linear fitting of a SIMS depth profile data using the thin film Gaussian solution to obtain the tracer diffusivity along with the background tracer concentration and tracer film thickness is discussed. An Arrhenius fit of the Mg self-diffusion data obtained using the low-temperature SIMS measurements from this study and the high-temperature radiotracer measurements of Shewmon and Rhines (1954) was found to be a good representation of both types of diffusion data that cover a broad range of temperatures between 250 - 627° C (523 900 K).

36 MATERIALS SCIENCE↗

Using gap-filled MAIAC AOD and WRF-Chem to estimate daily PM 2.5 concentrations at 1 km resolution in the Eastern United States

To link short-term exposures of air pollutants to health outcomes, scientists must use high temporal and spatial resolution estimates of PM 2.5 concentrations. We develop a daily PM 2.5 product at 1 × 1 km 2 spatial resolution across the eastern United States (east of 90° W) with the aid of 1 × 1 km 2 MAIAC aerosol optical depth (AOD) data, 36 × 36 km 2 WRF-Chem output, 1 × 1 km 2 land-use type from the National Land Cover Database, and 0.125° × 0.125° ERA-Interim re-analysis meteorology. A gap-filling technique is applied to MAIAC AOD data to construct robust daily estimates of AOD when the satellite data are missing (e.g., areas obstructed by clouds or snow cover). The input data are incorporated into a multiple-linear regression model trained to surface observations of PM 2.5 from the EPA Air Quality System (AQS) monitoring network. The model generates a high-fidelity estimate (r 2 = 0.75 using a 10-fold random cross-validation) of daily PM 2.5 throughout the eastern United States. Of the inputs to the statistical model, WRF-Chem output (r 2 = 0.66) is the most important contributor to the skill of the model. MAIAC AOD is also a strong contributor (r 2 = 0.52). Daily PM 2.5 output from our statistical model can be easily integrated into county-level epidemiological studies. The novelty of this project is that we are able to simulate PM 2.5 in a computationally efficient manner that is constrained to ground monitors, satellite data, and chemical transport model output at high spatial resolution (1 × 1 km 2 ) without sacrificing the temporal resolution (daily) or spatial coverage (>2,000,000 km 2 ).

47 OTHER INSTRUMENTATION↗

Irradiation-induced swelling of pure chromium with 5 MeV Fe ions in the temperature range 450–650 °C

A surface coating using pure chromium has been proposed to increase the accident tolerance of Zircaloy cladding in pressurized water reactors. However, there is not much irradiation experience with Cr alloys and especially pure Cr. In the present study, pure chromium was irradiated with 5 MeV Fe ions to 50 peak dpa (displacements per atom) at temperatures of 450, 500, 550, 600 and 650 °C. Then irradiation at the peak swelling temperature of 550 °C was conducted to 50, 100, 150 peak dpa. Swelling at 50 dpa was observed over the entire temperature range studied, 450–650 °C, but appeared to be decreasing strongly at the temperature boundaries of the experiment. After an initial transient of rapid swelling, chromium was observed to swell at a rate of ~0.03–0.04%/dpa (up to 120 local dpa), which is much lower than pure Fe at 0.2%/dpa. This low swelling rate was found to be relatively insensitive to dpa rate, which varied by a factor of ~2 over the depth of data collection. Here, swelling was observed to begin quickly with an incubation period less than 10 dpa. Self-organization in the form of void ordering was observed to be developing at 50 dpa, becoming better defined with increasing dose. The void alignment direction is determined to be the $\langle$111$\rangle$ axial direction.

36 MATERIALS SCIENCE↗

Verifying and assessing the performance of the perturbation strategy in polynomial chaos ensemble forecasts of the circulation in the Gulf of Mexico

Here we present an analysis of two recent efforts aimed at quantifying the uncertainties in a 30-day HYbrid Coordinate Ocean Model forecast of the circulation in the Gulf of Mexico, with particular emphasis on the separation of Loop Current Eddy Franklin, using Polynomial Chaos methods. The analysis herein explores whether the model perturbations lead to realistic representation of the uncertainty in the Gulf Circulation. Comparisons of model output with Sea Surface Height and current mooring data show that the observational data generally falls within the envelope of the ensemble and that the modal decomposition delivers “realistic” perturbations in the Loop Current region. We use information theory metrics to quantify the information gain and the computational trade-offs between different wind and initial conditions perturbation modes. The relative entropy measures indicate that two modes for initial condition perturbations are enough, in our model configuration, to represent the uncertainty in the Loop Current region; while two modes for wind forcing perturbations are necessary in order to estimate the uncertainty in the coastal zone. The ensemble statistics are then explored using the Polynomial Chaos surrogate and the newly developed contour boxplot methods.

54 ENVIRONMENTAL SCIENCES↗

Subduction, Underplating, and Return Flow Recorded in the Cycladic Blueschist Unit Exposed on Syros, Greece

Exhumed high-pressure/low-temperature (HP/LT) metamorphic rocks provide insights into deep (~20–70 km) subduction interface dynamics. On Syros Island (Cyclades, Greece), the Cycladic Blueschist Unit preserves blueschist-to-eclogite facies oceanic- and continental-affinity rocks that record the structural and thermal evolution linked to Eocene subduction. Despite decades of research, the metamorphic and deformation history (P-T-D) and timing of subduction and exhumation are matters of ongoing discussion. We suggest that Syros comprises three coherent tectonic slices and that each slice underwent subduction, underplating, and syn-subduction return flow along similar P-T trajectories, but at progressively younger times. Subduction and exhumation are distinguished by lineations and ductile fold axis orientations, and are kinematically consistent with previous studies that document top-to-the-S-SW shear (prograde-to-peak subduction), top-to-the-NE shear (blueschist facies exhumation), and then E-W coaxial stretching (greenschist facies exhumation). Amphibole zonations record cooling during decompression, indicating return flow above a cold slab. Multi-mineral Rb-Sr isochrons and compiled metamorphic geochronology show that the three slices record distinct stages of peak subduction (53–52, ~50, and 45 Ma) that young with structural depth. Retrograde blueschist and greenschist facies fabrics span ~50–40 and ~43–20 Ma, respectively, and also young with structural depth. Synthesized data sets support a revised tectonic framework for Syros, involving subduction of structurally distinct coherent slices and simultaneous return flow of previously accreted tectonic slices in the subduction channel shear zone. Distributed, ductile, dominantly coaxial return flow in an Eocene-Oligocene subduction channel proceeded at rates of ~1.5–5 mm/yr and accommodated ~80% of the total exhumation of this HP/LT complex.

58 GEOSCIENCES↗

Comparison of Mg-based liquid metal ion sources for scalable focused-ion-implantation doping of GaN

We compare the suitability of various magnesium-based liquid metal alloy ion sources (LMAISs) for scalable focused-ion-beam (FIB) implantation doping of GaN. We consider GaMg, MgSO 4 $\bullet$7H 2 O, MgZn, AlMg, and AuMgSi alloys. Although issues of oxidation (GaMg), decomposition (MgSO 4 $\bullet$7H 2 O), and excessive vapor pressure (MgZn and AlMg) were encountered, the AuMgSi alloy LMAIS operating in a Wien-filtered FIB column emits all Mg isotopes in singly and doubly charged ionization states. We discuss the operating conditions to achieve <20 nm spot size Mg FIB implantation and present Mg depth profile data from time-of-flight secondary ion mass spectrometry. We also provide insight into implantation damage and recovery based on cathodoluminescence spectroscopy before and after rapid thermal processing. Prospects for incorporating the Mg LMAIS into high-power electronic device fabrication are also discussed.

36 MATERIALS SCIENCE↗

Gallium-Doped Poly-Si:Ga/SiO 2 Passivated Emitters to n-Cz Wafers With iV oc >730 mV

Here, we form gallium-doped poly-Si:Ga/SiO 2 passivated contacts on n-type Czochralski (n-Cz) wafers using ion implantation of Ga and Ga-containing spin-on dopants. After annealing and passivation with Al 2 O 3 , the contacts exhibit i Voc values of >730 mV with corresponding Joe values of <5 fA/cm 2 . These are among the best-reported values for p-type poly-Si/SiO 2 contacts. Secondary ion mass spectroscopic depth profile data show that, in contrast to B, Ga does not pileup at the SiO 2 interface in agreement with its known high diffusivity in SiO 2 . This lack of Ga pileup may imply fewer dopant-related defects in the SiO 2 , compared with B dopants, and account for the excellent passivation.

14 SOLAR ENERGY↗

Coaxial laser absorption and optical emission spectroscopy of high-pressure aluminum monoxide

This work advances laser absorption spectroscopy with measurements of aluminum monoxide (AlO) temperature and column density in extreme pressure ( P > 60 bar) and temperature ( T > 4000 K) environments. Measurements of the AlO A 2 Π i – X 2 Σ + transition are made using a microelectromechanical system, tunable vertical cavity surface emitting laser (MEMS-VCSEL). Simultaneous emission measurements of the AlO B 2 Σ + – X 2 Σ + transition are made along a line of sight that is coaxial with the laser absorption. Absorption temperature fits agree with emission spectra for a T = 3200 K, P = 9 bar case. In cases with T > 4000 K, P > 60 bar, absorption fits match the ambient temperature while emission fits over-estimate it, owing to high optical depths. These data juxtapose passive and active spectroscopic methods and demonstrate the versatility of AlO laser absorption in high-pressure and high-temperature environments where experimental data remain scarce, and engineering models will benefit from refined measurements.

Daniel, K. A.↗