Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data center design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Optimization of Pressurized Oxy-Combustion with Flameless Reactor

Pressurized OxyECombustion is one of the most promising technologies for utility-scale power generation plants. Benefits include the ability to burn low rank coal and capture CO 2 . By increasing the flue gas pressure during this process, greater efficiencies are derived from increased quantity and quality of thermal energy recovery. UPA with modeling support from MIT and testing and data verification by Georgia Tech’s Research Center designed and built a 100 kW system capable of demonstrating pressurized oxyEcombustion using a flameless combustor. Wyoming PRB coal was run at 15 and 32 bar. Additional tests were not completed but sampled data demonstrated the viability of the technology over a broader range of operating pressures, Modeling results illustrated a flat efficiency curve over 20 bar, with optimum efficiency achieved at 29 bar. This resulted in a 33% (HHV) efficiency, a 5 points increase in efficiency versus atmospheric oxy-combustion, and a competitive cost of electricity plus greater CO 2 avoidance costs then prior study’s presented. UPA’s operation of the bench-scale system provided evidence that key performance targets were achieved: flue gas sampled at the combustor outlet had non-detectable residual fly ashes, and low levels of SO3 and heavy-metal. These results correspond to prior pressurized oxy-combustion testing completed by IteaEEnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EnDEVR: An Environment for Data Engineering in VR

Organizations within the public and private sectors are looking to improve their data science operations for research, development, and operational purposes. As this interest in data science grows, so too does interest in tools and programs that facilitating such operations. This paper presents EnDEVR, the Environment for Data Engineering in Virtual Reality, a user-extensible system that allows for the execution of custom data science functions. We describe the user-centered design process for the EnDEVR system, based on the needs of subject matter experts within the aerospace and aviation industries. Fundamental to this design is a method for users to integrate their existing analysis code (that may leverage third-party vendors) as usable objects in the virtual environment; this allows organizations to operate without the price tag and lifetime obligations associated with commercial data science toolkits, a concept known as “vendor lock-in”. We then present our system design with iterative implementations, and conclude with lessons learned. The presented work may provide insight into future user-centered design processes for VR applications, particularly for digital transformation stakeholders to circumvent vendor lock-in.

Human-centered computing↗

Design Concepts for an Outage Control Center Information Dashboard

The nuclear industry, and the business world in general, is facing a rapidly increasing amount of data to be dealt with on a daily basis. In the last two decades, the steady improvement of data storage devices and means to create and collect data along the way influenced the manner in which we deal with information. Most data is still stored without filtering and refinement for later use. Many functions at a nuclear power plant generate vast amounts of data, with scheduled and unscheduled outages being a prime example of a source of some of the most complex data sets at the plant. To make matters worse, modern information and communications technology is making it possible to collect and store data faster than our ability to use it for making decisions. However, in most applications, especially outages, raw data has no value in itself; instead, managers, engineers and other specialists want to extract the information contained in it. The complexity and sheer volume of data could lead to information overload, resulting in getting lost in data that may be irrelevant to the task at hand, processed in an inappropriate way, or presented in an ineffective way. To prevent information overload, many data sources are ignored so production opportunities are lost because utilities lack the ability to deal with the enormous data volumes properly. Decision-makers are often confronted with large amounts of disparate, conflicting and dynamic information, which are available from multiple heterogeneous sources. Information and communication technologies alone will not solve this problem. Utilities need effective methods to exploit and use the hidden opportunities and knowledge residing in unexplored data resources. Superior performance before, during and after outages depends upon the right information being available at the right time to the right people. Acquisition of raw data is the easy part; instead, it is the ability to use advanced analytical, data processing and data visualization methods to turn the data into reliable information and comprehensible, actionable information. Techniques like data mining, filtering and analysis only work reliably for well-defined and well-understood problems. The path from data to decision is more complex. The ability to communicate knowledge during outages and emergent issues is crucial. This paper presents an approach to turn the unused data into an opportunity: applying principles from semiotics, human factors and visual analytics to transform the traditional way of processing outage data into media that will improve the collective situation awareness, knowledge, decisions, actions and overall performance of the entire outage team, and also support the reliability, quality and overall effectiveness of maintenance work. The application of the proposed visualization methods will become the medium of a semi-automated analytical process where humans and machines cooperate using their respective, distinct capabilities for the most effective results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Exploring DAOS as a Burst Buffer for a 100 Gbps DAQ Real-Time Streaming System

We present an experimental evaluation of a burst buffer for a real-time DAQ streaming system designed to transmit instrument data to remote data centers. The system is based on EJ-FAT, a load balancing system capable of Nx 100Gbps streams, distributing data from event sources to processing nodes. We explore applying the DAOS system as a burst buffer to serve a number of purposes: improve resiliency, elasticity and add new functions into the processing pipeline. In the evaluation a sender transmits events over a 100Gbps network to a receiver integrated with DAOS to store the reassembled events using DAOS APIs. We evaluate the system for possible bottlenecks and provide end-to-end evaluation with a burst buffer using DAOS storage abstractions. We show that a receiver node can support 38.1 Gbps. This proves the viability of our approach and allows us to extend this work to investigate scale-out properties and new streaming optimizations.

Mei, Xinxin↗

Bar-Chart-Monitor System For Wind Tunnels

Real-time monitor system provides bar-chart displays of significant operating parameters developed for National Full-Scale Aerodynamic Complex at Ames Research Center. Designed to gather and process sensory data on operating conditions of wind tunnels and models, and displays data for test engineers and technicians concerned with safety and validation of operating conditions. Bar-chart video monitor displays data in as many as 50 channels at maximum update rate of 2 Hz in format facilitating quick interpretation.

Jung, Oscar↗

The Geostationary Operational Environmental Satellite (GOES) Product Generation System

The Geostationary Operational Environmental Satellite (GOES) Product Generation System (GPGS) is introduced and described. GPGS is a set of computer programs developed and maintained at the Global Hydrology and Climate Center and is designed to generate meteorological data products using visible and infrared measurements from the GOES-East Imager and Sounder instruments. The products that are produced by GPGS are skin temperature, total precipitable water, cloud top pressure, cloud albedo, surface albedo, and surface insolation. A robust cloud mask is also generated. The retrieval methodology for each product is described to include algorithm descriptions and required inputs and outputs for the programs. Validation is supplied where applicable.

Haines, S. L.↗

Progress Status of Skutterudite-Based Segmented Thermoelectric Technology Development

Young's modulus, bulk density, fracture strength, and fracture toughness of alpha silicon carbide manufactured by extrusion and by isopressing were measured at room and elevated temperature in order to determine material feasibility as augers for the Tile Overlay Repair attachment. The measured properties of extruded and isopressed materials differ significantly, with the extruded material exhibiting marked strength anisotropy and lower density. The measurements were made between July and September 2006 at Glenn Research Center (GRC), in order to obtain design data for use in structural and thermal mathematical models.

Seqmented Thermoelectric Technoloqy (STE)↗

CIM's bridge from CADD to CAM: Data management requirements for manufacturing engineering

Manufacturing engineering represents the crossroads of technical data management in a Computer Integrated Manufacturing (CIM) environment. Process planning, numerical control programming and tool design are the key functions which translate information from as engineered to as assembled. In order to transition data from engineering to manufacturing, it is necessary to introduce a series of product interpretations which contain an interim introduction of technical parameters. The current automation of the product definition and the production process places manufacturing engineering in the center of CAD/CAM with the responsibility of communicating design data to the factory floor via a manufacturing model of the data. A close look at data management requirements for manufacturing engineering is necessary in order to establish the overall specifications for CADD output, CAM input, and CIM integration. The functions and issues associated with the orderly evolution of computer aided engineering and manufacturing are examined.

Ford, S. J.↗

CTAS data analysis program

The analysis program (AN) is specifically designed to produce graphic and tabular information to aid in the design and checkout of the Center TRACON Automation System (CTAS). To best reveal CTAS operation and possible problems, data are plotted in many different ways both in detail and summary form. AN has been designed to analyze both radar surveillance data and output data from CTAS. AN has been extensively used to debug and refine CTAS. It is also being used in the field to monitor and assess CTAS performance. AN is continuously refined to keep up with changing needs. The present version of AN grew out of analysis of Denver Center data. However, the AN software has been written to be adaptable to any other facility Center or TRACON. Presently, one can select Denver Stapleton, Denver International, Dallas/Fort Worth International Airport, and Dallas Love Field.

Neuman, Frank↗

Ultra-low thermal resistance and pressure drop copper and copper-tungsten diamond-shaped pin fin cold plates for liquid cooling of electronics

Modern and future data centers face increasing cooling challenges due to increasing chip thermal design power and die size, along with the need to reduce energy consumption used for cooling. High performance cooling solutions that maintain a low chip junction temperature are needed to ensure electronics reliability. This work develops an ultra-low thermal resistance and low pressure drop 75 mm × 75 mm cold plate, intended for next-generation electronics cooling. The cold plate features an array of diamond-shaped pin fins and integrated copper tungsten heat spreader, selected for its low coefficient of thermal expansion which reduces thermomechanical deformation and allows for closer integration of the cold plate with silicon dies. Starting with 300 candidate designs, three-dimensional computational fluid dynamics simulations predict the thermal-hydraulic performance of cold plate subsections. The highest performing geometries are evaluated with high fidelity simulations. Four cold plates are manufactured for experiments: three with diamond-shaped pin fins and one with straights fins for comparison purposes. The cold plates are fabricated from copper-tungsten (CuW), copper (Cu), or aluminum-silicon-magnesium alloy (AlSi10Mg). The diamond-shaped pin fins achieve a roughly 15 % lower thermal resistance compared to the conventional straight fin microchannel. The highest performing design achieves a chip-to-coolant (including thermal interface material) thermal resistance of 9.0 K/kW in CuW and 6.9 K/kW in Cu under a 1 kW heat load with an inlet-to-outlet pressure drop of 9.0 kPa and water as the working fluid. This work demonstrates ultra-low thermal resistance and pressure drop cold plates for large die, high heat load applications, and shows that CuW is an attractive cold plate material for improved reliability in next generation data center cooling.

Coefficient of thermal expansion↗

Mission Operations and Ground Systems 101

The purpose of this tutorial is to provide an introduction to various space mission types, link together the various mission systems engineering concepts which go into the design and development of a space mission with the ground system architecture. Attendees will learn about: Types of satellite missions and characteristics of them, Types of satellite orbits and why a particular mission is in a particular orbit, Characteristics of different satellite operators (commercial, DoD, civil), Mission drivers, Mission operations concepts and how various challenges have been addressed, Space mission data standards, How to deliver data, General ground system and Mission Operations Center design.

Theresa Beech↗

Predictions of entry heating for lower surface of shuttle orbiter

A broad base of thermocouple and phase change paint data was assembled and correlated to the nominal design 14414.1 and proposed STS-1 (first flight of the space transportation system) entry trajectories. Averaged data from phase change paint tests compared favorably with thermocouple data for predicting heating rates. Laminar and turbulent radiation equilibrium heating rates were computed on the lower surface of the Shuttle orbiter for both trajectories, and the lower surface center line results were compared both with aerodynamic heating design data and with flight values from the STS-1 and STS-2 trajectories. The peak laminar heating values from the aerodynamic heating design data book were generally 40 to 60 percent higher than the laminar estimates of this study, except at the 55 percent location of maximum span where the design data book values were less than 10 percent higher. Estimates of both laminar and turbulent heating rates compared favorably with flight data.

Edwards, C. L. W.↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UH-60A Airloads Catalog

As a part of the NASA-Army UH-60A Airloads Program, instrumented rotor blades were designed and built for the UH-60A helicopter that included 241 pressure transducers on one blade and a suite of strain gauges and accelerometers on a second blade. These blades were then installed on a UH-60A at NASA Ames Research Center and a special purpose data acquisition system was designed and built to acquire the rotating system measurements. The aircraft was also instrumented with conventional aircraft state measurements as well as a suite of fuselage accelerometers. Test flights of the highly-instrumented UH-60A were flown from August 1993 to February 1994 and an extensive data base was acquired. A total of 31 research flights were made with the majority of the flights flown out of Moffett Field, California. The test data, in general, were acquired in isolated airspace over the San Joaquin Valley. An exception to this procedure is that nine flights were made in cooperation with NASA Langley Research Center, and for these tests the aircraft was flown out of the Modesto airport and the data were acquired at the Crows Landing Naval Auxiliary Air Field, also within the San Joaquin Valley. Over 900 different test conditions, or counters, were recorded, processed, and stored in an electronic data base as a part of this test program. The electronic data base, currently at NASA Ames Research Center, includes approximately 30 GBytes of data obtained from the test program. This Technical Memorandum summarizes the kinds of data that are in the data base to assist interested users. Each set of test conditions is presented in a table which contains a unique identifying number that is termed the counter number, the written description of the counter that is within the database, and the duration of the counter in seconds. Within each table the counters are listed in chronological order, and in some cases counters may be included within two or more tables if they meet different criteria.

UH-60A↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-design Center for Exascale Machine Learning Technologies (ExaLearn)

We report rapid growth in data, computational methods, and computing power is driving a remarkable revolution in what variously is termed machine learning (ML), statistical learning, computational learning, and artificial intelligence. In addition to highly visible successes in machine-based natural language translation, playing the game Go, and self-driving cars, these new technologies also have profound implications for computational and experimental science and engineering, as well as for the exascale computing systems that the Department of Energy (DOE) is developing to support those disciplines. Not only do these learning technologies open up exciting opportunities for scientific discovery on exascale systems, they also appear poised to have important implications for the design and use of exascale computers themselves, including high-performance computing (HPC) for ML and ML for HPC. The overarching goal of the ExaLearn co-design project is to provide exascale ML software for use by Exascale Computing Project (ECP) applications, other ECP co-design centers, and DOE experimental facilities and leadership class computing facilities.

97 MATHEMATICS AND COMPUTING↗