Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cybersecurity recommendations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Recommendations for Trust and Encryption in DER Interoperability Standards

Recently developed Distributed Energy Resource (DER) interoperability standards include communication and cyber security requirements. In 2018, the US national interconnection standard, IEEE 1547, was revised to require DER to include a Sun Spec Modbus, IEEE 2030.5 (Smart Energy Profile, SEP 2.0), or IEEE 1815 (DNP3) communication interface but does not include any normative overarching cybersecurity requirements. IEEE 2030.5 and associated implementation requirements for California, known as the California Smart Inverter Profile (CSIP), prescribe the greatest security features - including encryption, authentication, and key management requirements. Sun Spec Modbus and IEEE 1815 security requirements are not as comprehensive, leading to implementation questions throughout the industry. Further, while the security features in IEEE 2030.5 are commonly used in computing platforms, there are still questions of how well the technologies will scale in highly-distributed, computationally-limited inverter environments. In this paper, (a) the elements of IEEE 2030.5 encryption, authentication, and key management guidelines are analyzed, (b) potential scalability gaps are identified, and (c) alternative technologies are explored for possible inclusion in DER interoperability or cyber security standards.

42 ENGINEERING↗

Countering Weapons of Mass Destruction (CWMD) Zero Trust Framework: CWMD Zero Trust Principles Model

The research focuses on the critical need for enhanced cybersecurity within the Countering Weapons of Mass Destruction (CWMD) Office, specifically targeting Chemical, Biological, Radiological, and Nuclear devices. Traditional perimeter-based security models are insufficient against modern cyber threats, prompting a shift toward Zero Trust principles (ZTP) that emphasize continuous verification and stringent security for all devices. Federal directives mandate the adoption of Zero Trust (ZT) across agencies, supported by guidelines from National Institute of Standards and Technology (NIST), U.S. Department of Homeland Security (DHS) Cybersecurity and Infrastructure Security Agency (CISA), U.S. Department of Defense (DoD) and National Security Agency (NSA). The research involved mapping ZT guidance from these agencies to develop tailored CWMD ZTP. The study identified gaps and areas for improvement, including clear transitional guidance from traditional to ZT architectures and the focus on explicit cross cutting capabilities. Design improvements are recommended to ensure increased comprehensive protection and resilience against sophisticated cyber threats for Chemical, Biological, Radiological, and Nuclear (CBRN) devices. Collaborative efforts among federal agencies are essential for the successful deployment of an optimized ZT guidance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

eGridGPT: Trustworthy AI in the Control Room

This report outlines the synergy between human decision making and generative artificial intelligence (GenAI), where GenAI supports power system operators by analyzing procedures, suggesting actions, simulating scenarios with physics-based digital twins, and recommending optimal decisions. This report is the first research effort to apply large language models (LLMs), a type of GenAI, in the power grid control room. The authors describe the Electric Grid Generative Pretrained Transformer (eGridGPT), an LLM that virtually assists system operators. Developed with cybersecurity and regulatory requirements in mind, eGridGPT represents an opportunity to responsibly evolve control room technologies to meet the needs of a rapidly changing grid. As an innovative concept, eGridGPT seeks to spearhead productive discussions about the advanced technologies in the control room of the future amid the transition to clean energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Women in Science: Fermilab cybersecurity analyst Jeny Teheran

With 11 February marking the International Day of Women and Girls in Science, female physicists, engineers and computer scientists from CERN and from Fermilab share their experiences of building a career in science. Jeny Teheran is a security analyst and cybersecurity researcher at Fermi National Accelerator Laboratory. That means keeping up with and taking care of hardware and software vulnerabilities so that the experiments can carry out their science in a secure manner. It's a fast-paced job where you have to come with the best solution you can put in place, right in the moment. "I would recommend this job because it challenges you. It pushes you to be on top of your game. You have to improve your analytical skills; you have to react fast; you have to communicate better." - Jeny says. Jeny came to Fermilab from the Caribbean coast of Colombia. She grew up in a house with few toys but lots of books, and says she has always felt close to science. With a degree in systems and computing engineering, she arrived at Fermilab four years ago as an intern to work on the offline production team for neutrino experiments. A year later, she was hired as a security analyst. "And I'm loving it," she says. Credits: Video production - Fermilab Creative Services Music Copyright: Universal Production Music Astral Light Chevalier Idea originally conceived by Tanya Levshina, Fermilab and Maria Dimou, CERN.

99 GENERAL AND MISCELLANEOUS↗

A Literature Review: Smart Grids Impacts on Nuclear Power Plants Task 4: Project Final Report

This report describes the results of a literature review performed to study the current state of electric power industry efforts and research work regarding Smart Grid technologies, renewable energy integration, grid reliability standards, and USNRC electric grid regulations and guidance. The information gathered in the literature review is intended to: (1) Develop a better understanding of the impacts that Smart Grid implementation and the integration of renewable energy sources can have on the availability and reliability of the electric grid as a source of offsite power, (2) Provide an understand of the present grid reliability standards and how they will address the challenges of Smart Grid implementation, (3) Identify electrical system vulnerabilities and failure modes that may result from the implementation of Smart Grid technologies and cybersecurity threats, (4) Provide an understand of the actions being taken by FERC, NERC and others to identify, understand and address potential impacts, (5) Provide an understand of existing NRC regulation and guidance addressing requirements of grid design, operation and reliability supporting NPP design requirements, and (6) Recommend any additional actions or studies that should be undertaken by the NRC to ensure compliance of NPPs to GDC 17 and any other applicable regulations and guidance as the electric grid evolves into the Smart Grid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Midwest Industrial Assessment Center (Final Technical Report)

The Midwest IAC’s prime center was at the University of Missouri (MU) and the satellite center was at Wichita State University, Kansas. During the 5-year period we conducted at least 96 energy assessments, with recommended energy cost savings of $10.3 million of which $6.5 million was implemented savings. The implemented energy savings were 0.63 Terra BTU and CO2 emissions reduction was 400,000 tons. Thirty-five students completed requirements for a certificate of completion from DOE. IAC students received training in cybersecurity basics and application to manufacturing, fundamentals of energy efficiency, ISO50001, smart manufacturing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity concerns for the energy sector in the maritime domain

The world has seen a number of high-profile maritime disasters in recent months and years, and has felt the impact of them. At the same time, the world has also seen a number of high-profile cyberattacks. It has felt their impact, as well. And, likely no sector has been more affected by the maritime and cyber incidents than the energy sector, as fuel prices often spike or trough, and access to energy resources can become an instant source of concern, tension, or even conflict. As energy sectors—in all their forms—continue to rely on the maritime domain or even increase that reliance, they must be mindful that traditional maritime threats—like piracy, theft, and weather events—are not the only threats they face today. Maritime cybersecurity concerns are among the most potentially disruptive to energy-sector interests and, yet, are among the least understood and least addressed. This paper identifies nine areas in which the energy sector faces harmful cyber vulnerabilities in the maritime domain, to provide enough insight and examples to allow for action to be taken to reduce the risk of harm from these different vulnerabilities. The paper develops the example of offshore wind energy to model how to assess cyber considerations more fully. Ultimately, it concludes with a series of recommendations that offer policymakers, energy-sector actors, and security and law-enforcement professionals steps to minimize the exposure of the maritime energy sector to harmful cyberattacks.

99 GENERAL AND MISCELLANEOUS↗

PLC Vulnerabilities and Mitigations

Programmable Logic Controllers (PLCs) are used extensively in many high-importance industrial and nonindustrial settings including controlling elevators, manufacturing machines, and utility facilities such as power and natural gas, however cybersecurity protection for them has been neglected. Within recent years, PLCs have been put under more security scrutiny and experts have advocated for changes from the addition of protocol encryption and network segmentation to intrusion detection systems on the PLCs themselves. While PLC security is critical, a large portion of the PLCs available today will never receive these changes due to being legacy or the difficulty of overhauling the security on existing systems. Due to the infeasibility of applying many recommended security measures towards currently available machines, we aim to provide realistic and affordable best practices for hardening PLCs. We will first conduct security analysis and consider attack vectors within our target PLC. Once we’ve analyzed the device’s security, we will evaluate a variety of mitigation methods and create guidelines to effectively reduce the threat posed by PLC attacks with minimal disruption to operations.

42 ENGINEERING↗

Overview and Recommendations for Cyber Risk Assessment in Nuclear Power Plants

Digital instrumentation and control (I&C) systems are being deployed in nuclear power plants (NPPs) for both existing and advanced reactor designs. As I&C systems become more digitized to allow features like near autonomous control and remote operation, they introduce greater cyber risk to NPPs. Cyberattacks targeting industrial control systems (ICSs) are growing in both qualities and capabilities, which indicates that cybersecurity needs to be an integral part of risk assessment in the industry. Although there are some risk assessment methods in traditional information technology (IT) cybersecurity, the differences between IT and ICS cybersecurity make it infeasible to apply these risk assessment methods directly to ICSs. Some research has focused on risk assessment methods for ICSs, but few studies focus on applications to NPPs. Ideal risk frameworks for the nuclear industry are dynamic and account for system dependencies; this survey review focuses on such risk assessment methods both in and outside the nuclear field. In this article, the major challenges in cybersecurity risk assessment research are pointed out, and further research suggestions and considerations for cyber risk assessment in I&C systems are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cybersecurity Assessment Methodology for International Safeguards

International nuclear safeguards are technical measures implemented by the International Atomic Energy Agency (IAEA) to verify the correctness and completeness of declarations made by States about their nuclear activities. The systems used to verify such activities include electronic and digital hardware and software components capable of data collection, processing, analysis, storage and transmission. Despite increasing efforts to protect digital systems against unauthorized access or attack through cybersecurity measures, these systems are not immune to cyber exploitation that could compromise their integrity or reliability. Previous versions of these systems did not include capabilities that exist today, such as BluetoothTM and GPS. The inclusion of these new capabilities, as well as new data processing and storage mechanisms, adds new attack vectors and opportunities for adversaries to exploit the devices that did not previously exist. As mentioned in the above referenced Cybersecurity for Safeguards study, cyber-domain vulnerabilities present risks to the equipment used to perform the international nuclear safeguards mission. The IAEA has produced guidance on the protection of nuclear facilities and their computer systems against cyber threats, but these documents do not specifically address the risks to safeguards or safeguards equipment. In response, the U.S. Department of Energy National Nuclear Security Administration (DOE/NNSA) Office of International Nuclear Safeguards/Safeguards Technology Development (NA-241) sponsored Sandia National Laboratories (Sandia, SNL) and the Idaho National Laboratory (Idaho, INL) to conduct a one-year study to evaluate cyber related vulnerabilities in safeguards equipment and develop recommendations for the mitigation of any identified risks.

97 MATHEMATICS AND COMPUTING↗

Security Architecture for Microgrid Integration

The purpose of this document is to present cyber security risk considerations and mitigations for community microgrids. The mitigations discussed herein specifically focus on cyber security technical requirements for the De-centralized Autonomous Community Controller (DAC) as part of the SECURE project’s technology development effort. These requirements also consider the associated security implementation challenges involved with the decentralized characteristics of microgrids where upstream communications to utility security management functions are lost. These security recommendations and technical requirements may be used by microgrid implementers and technology vendors to specify the security design of the microgrid systems and their components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Named Data Networking for DER Cybersecurity

We present our research findings on the novel NDN protocol. In this work, we defined key attack scenarios for possible exploitation and detail software security testing procedures to evaluate the security of the NDN software. This work was done in the context of distributed energy resources (DER). The software security testing included an execution of unit tests and static code analyses to better understand the software rigor and the security that has been implemented. The results from the penetration testing are presented. Recommendations are discussed to provide additional defense for secure end-to-end NDN communications.

97 MATHEMATICS AND COMPUTING↗

A National Secure-by-Design Strategy

The US National Cybersecurity Strategy published March 2, 2023 uses plain language to communicate that the US is calling for a major change in how we prioritize the security of software systems used in critical infrastructure. It acknowledges that our current approach, which is essentially, “let the buyer beware,” leaves entities who are least able to assess or defend vulnerable software responsible for the impacts of designed-in weaknesses while the makers of the technology bear no liability. The strategy recommends a security-by-design approach, recommending that software vendors be held liable to uphold a “duty of care” to consumers and for systems to be designed to “fail safely and recover quickly” . For energy infrastructure, the strategy calls out the need to implement the National Cyber-Informed Engineering Strategy to achieve higher confidence security for energy infrastructures. The Idaho National Laboratory, a pioneer in cyber-informed engineering concepts, is at the forefront of organizations educating others in industry, academia, and government on how to apply these concepts to real-world challenges. In this brief, we'll outline some of the basic principles of security-by-design and offer examples of how, in a water sector context, they're being put into successful practice.

42 ENGINEERING↗

IMPLEMENTING CYBERSECURITY INTO AN EXISTING NATIONAL NUCLEAR NON-PROLIFERATION PROGRAMME – A CASE STUDY

Cyber threat profiling and risk mitigation is critical to any nuclear state organization and should be considered as part of any comprehensive nuclear security programme. Defining and evaluating the impact of the cyber threat to mission can be challenging. An existing national nuclear non-proliferation organization undertook an effort to incorporate computer security activities into its programme to address cyber risk. One of the primary goals of this endeavour was to develop a set of prioritised recommendations for organizational follow-through. The organization dedicated subject matter expert resources in the form of a cyber task force to support this goal. Opportunities were identified where computer security could be built into each programme including office-level strategies and tools. Of course, no new identified threat vector is easily considered and incorporated into existing programmes without impact. There are many obstacles to be overcome. Technically literate subject matter experts are difficult to find, management has comparatively less experience applying computer security into its programmes, and trying to change the culture to consider computer security risk at policy and programmatic levels takes time and management attention. As an outcome of this process, a roadmap for program integration was developed, including the establishment of a cyber support team. This paper will discuss the challenges and successes associated with establishing such a team.

Cyber Security, Nuclear, Non-proliferation↗

Cyber Labeling for Energy Industrial IoT

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security and Emergency Response (CESER), at the request of the Deputy National Security Advisor for Cyber and Emerging Technologies, Anne Neuberger, initiated research in 2023 to develop a cybersecurity labeling proof-of-concept for energy products to expand on the Federal Communications Commission’s (FCC) proposed U.S. Cyber Trust Mark program. DOE mobilized researchers from six National Laboratories to develop and gather feedback on a proof-of concept label for solar inverters and smart meters, which serve as representative products for market-facing energy sector Industrial Internet of Things (IIoT). This report details the research team’s process across two phases and the resulting findings, which include challenges facing cyber labeling programs and recommendations to implement an expanded IIoT cyber labeling program in the U.S.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state, and to rapidly recover operational capabilities for essential functions after a successful attack. The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.” As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state,1 and to rapidly recover operational capabilities for essential functions after a successful attack.2 The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.”3 As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗