Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyber resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Deep Learning Approach for In-Network Synchrophasor Missing Data Recovery Using Programmable Network Switches

Phasor measurement unit (PMU) networks deliver accurate and timely measurements, which is essential for managing today’s electric power systems. To ensure data quality and enhance the cyber-resilience of PMU networks against malicious attacks and data errors, this study presents an online PMU missing data recovery scheme by leveraging P4 programmable switches. The data plane incorporates a customized PMU protocol parser that abstracts the necessary payload data for recovery. Recovery processes are executed in the control plane using a pre-trained machine learning model. Both traditional and advanced ML models, such as transformer and TimeGPT, are explicitly employed for data prediction. This approach ensures rapid and precise data recovery. Performance evaluations focus on recovery speed and accuracy, using a real dataset from a campus microgrid. With 20% missing PMU data, the mean absolute percentage error for voltage magnitude is 0.0384%, and the phase angle error discrepancy is approximately 0.4064%.

Phasor Measurement Unit, Machine Learning, Program↗

Cybersecurity for Energy Delivery Systems

The Cyber Resilient Energy Delivery Consortium (CREDC) started operations on October 1, 2015. The original period of performance ended September 30, 2020. During this span, CREDC developed projects with significant and measurable sector impact, achieved by involving industry partners (asset owners, equipment vendors, and technology providers) early and often, from helping us to identify critical sector needs, to performing pilot deployment and technology adoption. The central project goal was to create a research and development ecosystem where research results lead directly to development of applications and methodologies which are then validated in realistic contexts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

ARCADE Analysis Methods & Validation Pathway

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) provides an automated analysis system which supports risk-informed performance based (RIPB) evaluations of nuclear control systems. Every possible cyber threat which could lead to consequence is identified by simulating the unsafe control action sequences which transform digital harm into physical harm. Eliminating the simulation of complex digital cyber attack chains cuts out unnecessary computational overhead and focuses directly on the physics of cyber-physical attacks. This focus enables designers to make informed decisions which can entirely eliminate categories of cyber threats against advanced reactors through the physical nature of the plant design. This narrowing of cyber threat against nuclear power plants through the physics of the system is intended to make any remaining threat management and cost efficient. This is the goal of the Tiered Cyber Analysis (TCA) outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors. ARCADE has been custom developed to meet the demands of the rigorous analysis required in Tier 1 of the TCA, which forms the foundation of the TCA process. Currently, ARCADE is still under development, but has made significant leaps in capability. A pilot analysis on the opensource Asherah simulator was performed which demonstrated key functionality goals. The next stage of ARCADE development involves improvements to the applications which support the analysis system, and enabling the analysis system to utilize the full suite of unsafe control action simulations. Since the analysis method’s core functions are complete, validation of the analysis method will be started concurrent to the next development stages. The automated analysis ARCADE will provide can radically change the cybersecurity design process for advanced reactors, reducing the cost of security implementation while enhancing cyber resilience. The pathway for ARCADE’s development to this goal has become much clearer. The majority of technical hurdles have been cleared, and the remaining development needs have been solidified. ARCADE is now capable of assisting the advanced reactor design process and directly support advanced reactor industry RIPB practices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

5G integrated edge computing platform for efficient component monitoring in coal-fired power plants

This project developed a cutting-edge 5G-integrated edge computing framework to enhance operational efficiency and reliability in coal-fired power plants through real-time component monitoring and anomaly detection. The initiative focused on leveraging distributed machine learning, federated learning, and 5G-based dynamic network slicing to support scalable, fault-tolerant monitoring environments to meet the operational requirements in industrial control systems. With a Distributed Edge Computing Service (DECS) orchestration, this project enabled federated learning at edge for condition monitoring and introduced adaptive client selection strategies to minimize communication overhead. Scalable distributed training was achieved using the Horovod framework, thus enhancing performance across edge nodes. In the realm of 5G networking, the project designed and deployed reconfigurable, QoS-aware network slicing tailored for operational technology (OT) environments, integrating software-defined networks to bolster cyber-resilience and enabling dynamic slicing for federated learning workloads. A significant milestone was the development of a virtualized ICS environment with 5G core integration—which allowed elastic and fault tolerant distributed training on real-world datasets such as NASA Bearings, Hydraulic Systems, and TEP. To broaden the impact of the project, a TRL-3 virtualized ICS testbed for research and education was designed. This project engaged several graduate and undergraduate students to conduct research on the cutting-edge technology, and it resulted in one PhD dissertation, one MS thesis, and over 14 peer-reviewed publications. With the support of this project students also participated in national cybersecurity competitions to improve their professional development skills.

20 FOSSIL-FUELED POWER PLANTS↗

Firmware Tampering Detection in Heavy-Duty Vehicles through J1939 CAN Analysis

Modern heavy-duty vehicles rely on complex networks of Electronic Control Units (ECUs) that communicate using the J1939 protocol. While this system makes it easier to update and configure vehicle components, it also opens the door to serious cybersecurity risks if not properly secured. This work investigates the potential for firmware tampering through the J1939 communication protocol, which enables ECU configuration and reprogramming over the Controller Area Network (CAN) bus. By monitoring CAN traffic during legitimate maintenance operations and reverse-engineering OEM diagnostic software, we identified common and proprietary J1939 message identifiers, authentication patterns, and vulnerabilities within Unified Diagnostic Services (UDS). These findings demonstrate that inadequate authentication mechanisms can allow malicious actors to alter ECU firmware or disable safety functions, posing severe operational and safety risks. Our analysis contributes to the development of vehicle intrusion detection systems capable of recognizing abnormal reprogramming activity and future firmware fingerprinting methods to verify software integrity across ECUs. This work highlights the importance of standardizing secure firmware authentication across manufacturers to strengthen cyber resilience in heavy-duty vehicle systems.

33 ADVANCED PROPULSION SYSTEMS↗

Cybersecurity Center for Offshore Wind Energy (Final Project Report)

This project establishes a Cybersecurity Center for Offshore Wind Energy with the objective of designing and operating a cyber-physical testbed for wind energy farms (WEFs) that enables comprehensive cybersecurity research. The testbed incorporates a Supervisory Control and Data Acquisition (SCADA) system connected to turbine models via industrial-grade programmable logic controllers (PLCs) and remote terminal units (RTUs). It supports side-channel data acquisition, implementation and analysis of various cyberattack scenarios, and development of attack detection, mitigation, and best-practice guidance tailored to wind energy systems. During the project, the team expanded the number and fidelity of mathematical turbine models (MTMs), integrated these models with SCADA infrastructure, and deployed a scaled physical turbine and associated sensors. High-resolution operational and side-channel data streams were collected and used to refine machine-learning (ML)-based attack detection systems and to extend the WindCRAFT framework to multi-turbine threat scenarios. The project demonstrated a realistic, scalable environment for evaluating cyber threats, validated attack detection approaches using enriched datasets, and identified new multi-turbine and inter-turbine communication attack vectors. The resulting testbed, models, and security mechanisms provide a foundation for ongoing R&D and deployment of cyber-resilient offshore wind energy systems.

17 WIND ENERGY↗

2021 Annual Report Laboratory Directed Research & Development

The Department of Energy’s (DOE) Laboratory Directed Research and Development (LDRD) program is an essential pathway for innovation, capability growth, and research staff development at Idaho National Laboratory (INL). This program enables timely and agile response to national security, energy, and environmental challenges that motivate INL’s mission to discover and demonstrate innovative nuclear energy solutions and other clean energy options as well as securing our critical infrastructure. This report highlights INL’s LDRD projects concluding in fiscal year (FY) 2021 which included innovative research and development (R&D) across INL’s five science and technology initiatives: nuclear reactor sustainment and expanded deployment, integrated fuel cycle solutions, integrated energy systems, advanced design and manufacturing for extreme environments, and secure and resilient cyber-physical systems.

99 GENERAL AND MISCELLANEOUS↗

Achieving American Leadership in Cybersecurity and Digital Components Factsheet

The Biden Administration’s efforts to meet 100% clean electricity by 2035 and net-zero greenhouse gas emissions by 2050 has created opportunities to rebuild American supply chains create new jobs, strengthen community engagement, and spur U.S. economic growth. DOE’s strategy for success in the transition to a clean energy economy hinges on building and maintaining technology supply chains that are advanced, secure, and resilient to cyber threats. As the energy sector grows increasingly globalized, complex, and digitized, the supply chain for digital components of energy systems – including software, virtual platforms and services, and data – is facing greater threats. Nearly all digital components of U.S. energy sector systems are vulnerable to cyber supply chain instability, stemming from a variety of causes and shared among a broad set of interdependent stakeholders. Overall, supply chain risks for digital components in energy sector systems will continue to evolve and likely increase as these systems are increasingly interconnected, digitized, and remotely operated.

CCE↗

Disrupting EV Charging Sessions and Gaining Remote Code Execution with DoS, MITM, and Code Injection Exploits using OCPP 1.6

Open Charge Point Protocol (OCPP) 1.6 is widely used in the electric vehicle (EV) charging industry to communicate between Charging System Management Services (CSMSs) and Electric Vehicle Supply Equipment (EVSE). Unlike OCPP 2.0.1, OCPP 1.6 uses unencrypted websocket communications to exchange information between EVSE devices and an onpremise or cloud-based CSMS. In this work, we demonstrate two machine-in-the-middle (MITM) attacks on OCPP sessions to terminate charging sessions and gain root access to the EVSE equipment via remote code execution (RCE). Second, we demonstrate a malicious firmware update with a code injection payload to compromise an EVSE. Lastly, we demonstrate two methods to prevent availability of the EVSE or CSMS. One of these, originally reported by SaiFlow, prevents traffic to legitimate EVSE equipment using a DoS-like attack on CSMSs by repeatedly connecting and authenticating several CPs with the same identities as the legitimate CP. These vulnerabilities were demonstrated with proof-of-concept exploits in a virtualized Cyber Range at Wright State University and/or with a 350 kW Direct Current Fast Charger (DCFC) at Idaho National Laboratory. The team found that OCPP 1.6 could be protected from these attacks by adding secure shell (SSH) tunnels to the protocol, if upgrading to OCPP 2.0.1 was not an option. Index Terms—Electric vehicle charging, cybersecurity, OCPP, cyberattack, cyber-resilience. INSPEC Accession Number: 23981565

99 GENERAL AND MISCELLANEOUS↗

Efficient Hybrid Attack Graph Generation for Cyber-Physical System Resilience Experimentation (Final Project Report)

HAGEN project has developed theory, algorithms, and capabilities to assist cyber physical system modelers and operators to perform system and device-level vulnerability assessment, risk assessment, impact assessment, and mitigation planning. The project generates hybrid attack graphs for Cyber-Physical System (CPS) resilience experimentation at desired scale and speed. The project will produce composite attack datasets, algorithms, and demonstrable prototypical tools, and a library of high-impact attack sequences for a given CPS of interest. This report provided overall summary of research and development performed between FY22-24.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Cyber State Awareness For Resilience

Characterization of cyber-physical attacks requires a holistic understanding of cyber and physical behavior in a system. Machine Learning Anomaly Detection provides a compelling solution for continuously identifying suspicious behavior within these complex systems. In our software, we present an approach for holistic characterization of cyber-physical systems based on cyber and physical anomaly correlation. The approach consists of three main components: 1) an architecture for real-time data acquisition, management, and analysis of both cyber and physical data; 2) cyber and physical data driven anomaly detection systems (ADSs), 3) a metric that combines cyber and physical ADSs to provide a holistic characterization of the system..

Rieger, CraigG.↗

Enhancing the distribution grid resilience using cyber-physical oriented islanding strategy

The increasing penetration of distributed generations enables an innovative operation paradigm that allows islanded operation to enhance the resilience of the distribution grid. In this study, a cyber-physical oriented islanding strategy is proposed by coordinating centralised and distributed control to achieve seamless islanding transition and operational flexibility in emergency conditions. A cyber-physical control structure is developed to mitigate various disturbances (e.g. emergencies or fluctuations) according to different operation conditions. Specifically, the distributed fault isolation and seamless islanding transition are coordinated to mitigate the outage caused by unplanned islanding, while a secondary control is proposed to support primary control by reducing the power fluctuations during islanded operation. With a rapid response speed, the local cyber-physical devices are coordinated to accomplish islanding separation by selecting a feasible islanded area even under an unplanned islanding situation. A field test was conducted on a practical distribution network in China, and the results demonstrated the effectiveness and feasibility of the proposed islanding strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration and Validation of Multi-Layer Mitigation Strategies for Cyber Physical Systems Resilience (RD2C Capstone I Project) (Technical Report)

This project demonstrated the effectiveness of RD2C-developed, resilience-driven control strategies on high-fidelity system models with high penetrations of inverter-based resources, under the impacts of unexpected natural events and cyber-physical attacks. Controller performance and overall system resilience were quantified using data from a comprehensive suite of scenarios, and provided a clear understanding on how to operate and deploy these mitigation strategies.

42 ENGINEERING↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state, and to rapidly recover operational capabilities for essential functions after a successful attack. The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.” As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Countering Weapons of Mass Destruction (CWMD) Device Cybersecurity Characterization Process and Profile

Countering Weapons of Mass Destruction (CWMD) recognizes that threats in the cyberspace domain continue to grow, which requires CWMD devices and supporting systems to be both cybersecure (ability to protect or defend from cyber-attacks) and resilient (ability to maintain required capability in the face of adversity) to cyber threats. The CWMD cybersecurity characterization approach in this document supports existing cyber resilience activities within the Acquisition Lifecycle Framework. Similarly, this process supports existing Department of Homeland Security Cyber Resilience Test and Evaluation activities, which consist of iterative processes, starting at the initiation of system acquisition and continuing throughout the entire device and system life cycle. Cyber resilience is the ability of an information system to continue to operate while under attack, even if in a degraded or debilitated state,1 and to rapidly recover operational capabilities for essential functions after a successful attack.2 The goal of the security characterization task for CWMD is to support the development of a CBRN device-dependent profile that aligns with device network capabilities and maps to recommended security controls to create a characterization security profile impact levels. The impact levels for CWMD devices should be characterized as Low (L), Moderate (M), High (H) to align with the low, moderate, high control baselines. To estimate the impact levels, the device’s security-related attributes are translated into the security objectives: Confidentiality (C), Integrity (I), and Availability (A), known as the CIA triad. The potential impact for each device can be L, M, H, for devices that connect and transmit different types of data and may have different impact levels. National Institute of Standards and Technology Federal Information Processing Standards Publication 199 states, “the potential impact values assigned to the respective security objectives shall be the highest value from among those security categories that have been determined for each type of information resident on the information system.”3 As CWMD is determining the cybersecurity impact levels of CBRN devices based on network connections and data transfers, the impact levels are aligned with the associated attributes of network connections and communications. For example, if the device system is connected to a wireless network and transmits different data types based on the confidentiality of the data, the highest impact value for each security objective should represent the device’s CIA impact level. This document is intended to be used by test managers, test team, and program managers.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗