Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “custom devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Mechanical Properties of 2D LiInP 2 Se 6 : Implication for Semiconductor Applications

Metal phosphorus trichalcogenides (MPTCs) are emerging 2D semiconductor materials with unique functional properties that set them apart from other 2D systems. Despite the importance of their mechanical properties for improving the semiconductor device’s durability and performance, as well as for utilizing strain effects to customize material properties and create new functionality, our current understanding of MPTCs’ mechanical behavior is lacking and lags behind our knowledge of their other properties. Here, we use LiInP 2 Se 6 as a model example of MPTCs and report the first experimental measurements of the elastic and plastic (fracture) properties along both in-plane and out-of-plane directions by atomic force microscopy and nanoindentation. Being a 2D material that is entirely inorganic, LiInP 2 Se 6 surprisingly exhibits mechanical properties that resemble those of hybrid organic–inorganic materials rather than pure inorganic 2D materials. It has a soft crystal structure with low elastic moduli, a low difference in in-plane vs out-of-plane mechanical properties, and a combination of elastic and plastic characteristics of hybrid organic–inorganic materials. Furthermore, our work provides the mechanical information critically needed to mitigate and/or harness the strain effects in LiInP 2 Se 6 -based semiconductor devices and sheds light on the mechanical behaviors of MPTCs with indispensable insights.

2D semiconductor↗

Correlating Oxidation State and Surface Area to Activity from Operando Studies of Copper CO Electroreduction Catalysts in a Gas-Fed Device

Copyright © 2020 American Chemical Society. The rational design of high-performance electrocatalysts requires a detailed understanding of dynamic changes in catalyst properties, including oxidation states, surface area, and morphology under realistic working conditions. Oxide-derived Cu catalysts exhibit a remarkable selectivity toward multicarbon products for the electrochemical CO reduction reaction (CORR), but the exact role of the oxide remains elusive for explaining the performance enhancements. Here, we used operando X-ray absorption spectroscopy (XAS) coupled with simultaneous measurements of the catalyst activity and selectivity by gas chromatography (GC) to study the relationship between oxidation states of Cu-based catalysts and the activity for ethylene (C2H4) production in a CO gas-fed cell. By utilizing a custom-built XAS cell, oxidation states of Cu catalysts can be probed in device-relevant settings and under high current densities (>80 mA cm-2) for the CORR. By employing an electrochemical oxidation process, we found that the Cu oxidation states and specific ion species do not correlate with C2H4 production. The difference in the CORR activity is also investigated in relation to electrochemical surface area (ECSA) changes. While the hydrogen evolution reaction (HER) activity is positively correlated to the ECSA changes, the increased C2H4 activity is not proportional to the ECSA. Ex situ characterization from microscopic techniques suggests that the changes in the C2H4 activity and selectivity may arise from a morphological transformation that evolves into a more active structure. These comprehensive results give rise to the development of a cell regeneration method that can restore the performance of the Cu catalyst without cell disassembly. Our study establishes a basis for the rational design of highly active electrocatalysts for broad-range reactions in a gas-fed device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grid Modernization of Cooperatives and Municipal Utilities via Breakthrough System Monitoring, Control and Optimization (CRADA Final Report)

This project aims at developing and demonstrating successful implementation of breakthrough approaches in real-time data visualization as well as real-time distributed DER control and optimization to provide ample benefits to both utilities and end users. The National Renewable Energy Laboratory (NREL), Holy Cross Energy (HCE), National Rural Electric Cooperative Association (NRECA) and Survalent are collaborating to enable Cooperative and Municipal utilities to fully leverage DERs as part of their strategies for providing safe, reliable, and affordable electric services to their customers and help meet DOE Grid modernization goal of achieving at least 10% active devices to provide grid flexibility by 2035. This project will use novel real-time control algorithms and approaches for distributed control recently developed under DOE-funded projects, using the date from the Survalent’s basic SCADA engine, GIS and AMI engines deployed at HCE combined with NRECA’s globally-used MultiSpeak(R) software interoperability specification for seamless and real-time communications between electric utility enterprise software to embrace DER as part of their strategies for providing safe, reliable and affordable electric service to their customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of a Wave Powered Water Pump Performance by Ocean Field Testing and WEC-Sim Modeling

This submission from AMEC (the Atlantic Marine Energy Center) includes data from an ocean field deployment of a wave powered water pump in March 2023. The wave pump is an upweller device, designed to enhance macroalgal aquaculture. The wave pump device was deployed off the coast of Isles of Shoals Appledore Island in Maine, USA. The data were collected using a custom-built DAQ module comprised of Arduino Unos. GPS time stamp accompanies the data. The data are volumetric flow rate from the wave pump, and relative motion of the device between float and spar buoys. Flow rate is measured by flow meter, and relative motion is measured by lidar. Calibration data for the lidar and flow meter sensors are included. This data set also includes synchronous Sofar Spotter buoy data from a mooring approximately 300 feet away from the wave pump mooring. Video data from the deployment are included from both on-board the device sporadically throughout the deployment, and from a webcam for a short duration of the deployment. Hydrophone data were also taken co-currently, and are available by contacting Martin Wosnik at the University of New Hampshire. The Matlab code used to process the field data is incorporated. A biological assessment is included which aided the NEPA consultation process, prior to conducting the field deployment. A WEC-Sim numerical model of the wave pump, and a re-design effort are part of this work. Code used to validate the WEC-Sim model from the field data are also included.

16 TIDAL AND WAVE POWER↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an Unmanned Mobile Current Turbine Platform: Preprint

The design and development of a prototype unmanned mobile floating platform, equipped with a custom low-flow marine current turbine for autonomously seeking and harnessing tidal/coastal currents is described. The platform is an unmanned surface vehicle in the form of a catamaran with two electric outboard motors and capabilities for autonomous navigation. An undershot water wheel, aided by a custom flow concentrator, has been selected as the basic design for the marine current turbine, which is mounted on the stern of the unmanned surface vehicle platform. The concept of operation is that the platform would navigate to a designated marine current resource, autonomously anchor at the location, align itself in the current and deploy the current turbine using a custom cable-lift deployment mechanism. As the turbine harnesses the local current, an onboard power-take-off device converts the harnessed mechanical energy to electricity which is stored in onboard batteries. Considerations of deployment in tidal and coastal waters required obtaining the necessary environmental permits for conducting in-water testing; developing required mitigation measures in protecting local wildlife and their habitats; and identifying potential in-water test sites and surveying them for their suitability in terms of the current resource, bottom type, water depth, and local boat traffic. The design and development of the turbine and the results of initial in-water testing are discussed. The potential for scaling up the system for extended capacity is presented.

ENGINEERING,TIDAL AND WAVE POWER↗

Dual-polarization O-band silicon photonics transmitter with an integrated tunable laser, Mach-Zehnder modulators, and SOAs

Presented is an O-band silicon photonics dual-polarization coherent/IMDD modulator integrated with semiconductor optical amplifiers and tunable laser to enhance the short-reach link budget. The laser demonstrated output power >6 dBm and a <250 kHz linewidth over a 14 nm tuning range. Modulators paired with custom 64 Gbaud QPSK drivers exhibited improved analog link sensitivity compared to similar devices without integrated gain sections. They also demonstrated 53 Gbaud dual-polarization PAM4 operation when characterized with a linear driver and MaxLinear 100G/lane DSP board. Both optical links achieved BERs at the KP4-FEC threshold and overall transmitter assembly energy consumption <6.9 pJ/bit without any thermal control when at steady room temperatures.

Liu, Junqian (ORCID:0000000167337650)↗

Distributed Temperature Profiles of Silicon Carbide Catalyst Bed in a Microwave Reactor using Fiber-optic Sensor

Microwave heating is of great interest for reducing greenhouse gas emissions of catalytic chemical conversion processes because it can heat up the reactants rapidly and efficiently and accelerate reaction rates. In microwave-assisted catalytic thermochemical conversion processes, accurate internal temperature measurement would help facilitate effective process control. Metallic thermocouples interfere and spark in the microwave heating environment, so they are not an option. Infrared pyrometers typically provide a single temperature value by averaging over a finite surface area of the catalyst bed. In this work, we use fiber-optic sensors passing through the catalyst bed to provide more accurate temperatures along the height of the catalyst bed. The fiber optic sensors are immune to the electromagnetic microwave radiation and provide temperature profiles along their length. Here, custom fiber-optic sensors were coupled to the optical distributed temperature sensing devices to measure the temperature profiles along the height of the catalyst bed at high temperatures with ~1 mm spatial resolution. The sensing devices use optical frequency domain reflectometry (OFDR) technique for distributed temperature measurement. This work shows the temperature profiles along the height of the silicon carbide powder catalyst bed in the variable and fixed frequency microwave reactors.

Thapa, Juddha↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Architecting the Grid Edge: Ensuring Reliability and Resilience

Changes in technology, customer expectations, and business and regulatory environments are rapidly evolving causing fundamental changes in the nation’s electrical infrastructure. Nowhere is this more apparent that at the “grid edge”, where there is an increasing number of new devices and systems, as well as complex new interactions between them. This is leading to the traditional relationship between the end-use customers and their utilities being expanded by an increasing number of stakeholders, each with their own operational and financial objectives, governed by regulatory policy. While there are concerns about the rapidly increasing complexity negatively impacting reliable and resilience of the electrical infrastructure, these changes are also bringing new resources and opportunities that hold great potential if they can be properly coordinated. This white paper outlines the considerations for the coordination of multi-stakeholder objectives with electric utility requirements using the concept of grid services. Describing a framework that enables new stakeholders to achieve their local technical and economic objectives, while simultaneously delivering operational benefits to the electrical infrastructure. The concepts of grid architecture are presented as a tool to evaluate how stakeholders might participate in, and benefit from, services, and how utilities can make decision on the reliance on services to ensure reliability and resilience, translating abstract concepts into actionable information for utilities and grid edge stakeholders. The end result of proper coordination, informed by grid architecture, will be a range of new devices and systems, operated by new stakeholders, achieving their local objectives while also increasing the reliability, resilience, security, and affordability of the nation’s critical electrical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Architecting the Grid Edge: Ensuring Reliability and Resilience

Changes in technology, customer expectations, and business and regulatory environments are rapidly evolving causing fundamental changes in the nation’s electrical infrastructure. Nowhere is this more apparent that at the “grid edge”, where there is an increasing number of new devices and systems, as well as complex new interactions between them. This is leading to the traditional relationship between the end-use customers and their utilities being expanded by an increasing number of stakeholders, each with their own operational and financial objectives, governed by regulatory policy. While there are concerns about the rapidly increasing complexity negatively impacting reliable and resilience of the electrical infrastructure, these changes are also bringing new resources and opportunities that hold great potential if they can be properly coordinated. This white paper outlines the considerations for the coordination of multi-stakeholder objectives with electric utility requirements using the concept of grid services. Describing a framework that enables new stakeholders to achieve their local technical and economic objectives, while simultaneously delivering operational benefits to the electrical infrastructure. The concepts of grid architecture are presented as a tool to evaluate how stakeholders might participate in, and benefit from, services, and how utilities can make decision on the reliance on services to ensure reliability and resilience, translating abstract concepts into actionable information for utilities and grid edge stakeholders. The end result of proper coordination, informed by grid architecture, will be a range of new devices and systems, operated by new stakeholders, achieving their local objectives while also increasing the reliability, resilience, security, and affordability of the nation’s critical electrical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery Equivalent Model for Residential HVAC

Flexible loads, especially heating, ventilation, and air-conditioning (HVAC) systems can be used to provide a battery-like service to the power grid by varying their demand up and down over a baseline. Recent work has reported that the round-trip efficiency for providing grid services with HVAC systems can be close to 1. Inspired by this promising result, in this work, we rigorously develop a battery equivalent model (BEM) for residential HVAC systems. Relying only on typically available data, the proposed BEM will bridge the observability and controllability gaps between utility companies and customers. The proposed BEM will enable the utility companies to manage the flexible HVAC devices as easy as charging/discharging the conventional energy storage devices. Validated physics-based models are used to train the BEM, whose prediction accuracy is illustrated through a simulation study.

Dong, Jin↗

A Case Study in NREL DERMS Asset Management Implementation

The National Renewable Energy Laboratory (NREL) and Smarter Grid Solutions (SGS) plan to present a case study on their implementation of SGS' Strata Grid Distributed Energy Resource Management System at NREL's Energy Systems Integration Facility (ESIF). The ESIF is one of the nation's premier energy systems integration laboratory facilities focused on development and deployment of clean energy technologies and resilient delivery systems. NREL looked for a DERMS to install at the ESIF that is capable of replicating real world scenarios to control and monitor distributed devices from small residential scale to the grid substation level. The DERMS system demonstrates the use cases of beneficial operation and coordination of modern grid devices, leverage DERs for improved grid planning and operation, demand-side management and customer engagement through bidirectional communication with utilities and energy market operations. The presentation will cover the delivery strategy of NREL and SGS, how the use cases help NREL's research, and NREL and SGS plan to expand the system and use cases.

ARIES↗

Low-Flow Marine Hydrokinetic Turbine for Small Autonomous Unmanned Mobile Recharge Stations

A prototype low-flow marine current turbine for deployment from a small unmanned mobile floating platform has been developed for autonomously seeking and harnessing tidal/coastal currents. The support platform is an unmanned surface vehicle (USV), in the form of a catamaran with two electric outboard motors and with capabilities for autonomous navigation. The USV utilized is a WAM-V 16 vehicle that has been developed separately with support from the Office of Naval Research (ONR) [1]. The marine current turbine is based on a freestream waterwheel (FSWW), also known as an undershot waterwheel (FSWW), mounted on the stern of the USV. The concept of operation involves the USV autonomously navigating to a designated marine current resource. Upon arrival, the USV anchors itself, aligns with the current, and deploys the FSWW turbine using a custom cable-lift mechanism. The turbine harnesses the local current, and an onboard power-take-off (PTO) device converts the mechanical energy into electricity, which is stored in an onboard battery bank. When energy harvesting is completed, the turbine and the anchor are retrieved and the USV navigates to a selected location. These unmanned at-sea platforms can provide power to other unmanned maritime systems. Specifically, in this project, the power generated onboard can be used to charge aerial drones via a custom flight deck that has been developed for the USV. The recharging capabilities offered by a fleet of such strategically placed recharging stations can significantly benefit aerial drones operating in the maritime domain by eliminating the need to travel back and forth to land or ship based charging stations. The project has resulted in the development of subcomponents, including the FSWW turbine, a novel PTO, an automated anchoring system for the USV, an automated turbine deployment system, and a flight deck with capabilities onboard the USV for landing, direct-contact charging and takeoff of aerial drones. The design and development of these subsystems have culminated in the overall prototype marine hydrokinetic platform (MHK Platform, Fig. 1). Comprehensive lab and field testing have been conducted to validate the functionality and performance of the platform and its components. The project demonstrates the potential for autonomous, unmanned systems to harness renewable energy from marine currents, and provide sustainable power solutions for maritime applications such as coastal surveillance and environmental monitoring; shoreline mapping; search and rescue; oceanographic research; inspection and maintenance of offshore energy installations like wind turbines and oil rigs; oil spill response; maritime disaster response; and aerial surveys, as well as facilitation of data transfer drones and shore stations.

16 TIDAL AND WAVE POWER↗

Switching Characteristics of a 1.2 kV, 50 mΩ SiC Monolithic Bidirectional Field Effect Transistor (BiDFET) with Integrated JBS Diodes

—The switching performance of large area (1cm x 1cm) monolithic 1.2 kV 50 mΩ 4H-SiC bidirectional field effect transistor (BiDFET) with integrated JBS diodes is reported for the first time. The devices were fabricated in a 6-inch commercial foundry and then packaged in a custom-designed four-terminal module. The switching performance of the BiDFET has been observed to be 1.4x better than that of its internal JBSFETs. Dynamic characterization was performed at 800 V with different gate resistances, current levels and case temperatures. An increase in switching losses was observed for the BiDFET with increasing gate resistance and current level as observed for SiC power MOSFETs. The BiDFET showed a 9% reduction in total switching loss from 25 °C to 150 °C with a current of 10 A.

Silicon Carbide, Monolithic, Bidirectional, FourQu↗

A Task Based Approach for Co-Scheduling Ensemble Workloads on Heterogeneous Nodes

Scientific workflows consist of multiple, connected applications, with data and results flowing from one to another in a pipeline. Traditionally, such workflows are executed in sequential order, storing intermediate data in storage disks. Co-scheduling application workflows concurrently on the same compute nodes would greatly reduce the cost of moving data to/from storage and allow real-time analysis of intermediate results. Nevertheless, most parallel programming runtimes do not allow seamless integration of various applications in a scientific workflow, in part due to the complexity of managing data and resources. The situation is even more complicated for heterogeneous systems. In this work we extend the Minos Computing Library (MCL) runtime to accelerate pipe-lined and parallel workloads where multiple applications are running in the same system. MCL’s asynchronous task library and runtime dynamically manages resources to allow co-scheduling of multiple processes sharing heterogeneous resources. In addition, we design a custom ex- tension of the Open Compute Language (OpenCL) to enable multiple processes to share device memory. We enable MCL to coordinate these shared buffers to allow for easy, fast data sharing between applications. Using malleable micro-benchmarks and two application workflows that combine scientific simulation and AI-based analysis, we show that our method outperforms traditional approaches.

Index Terms—Parallel systems, Scheduling and Task ↗