Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “custom devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Nanosecond Gated CMOS Camera (NSGCC) ICD (Rev. 2.1)

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time-gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and LLNL’s National Ignition Facility (NIF). Several cameras have been designed over the length of the program; one of the most recent is the Icarus, which is an improvement on past imagers (Furi and Hippogriff). A second sensor that can be connected is the Daedalus sensor. The Icarus is a 1024 × 512-pixel array with either 25 μm or 8 µm spatial resolution containing four frames of storage per pixel and has improved timing generation and distribution components while achieved 2 ns time gating. The Daedalus sensor is also a 1024 x 512-pixel array with 25 µm special resolution containing three frames of storage per pixel and has an increased set of features for a wider variety of applications from interlacing of rows in each frame to configurability of all shutters. See Section 14 for details regarding the Icarus implementation of the firmware and Section 15 for details regarding the Daedalus implementation. Due to the unique test environments UXI sensors are targeted for, full custom hardware was required to physically mount an Icarus or Daedalus sensor, manage its various functions, and read out pixel data for transfer to a host computer. Beyond experimental functionality, the hardware also needed to accommodate sensor characterization requirements. Lawrence Livermore National Laboratory’s ‘Version 4.0 Board’ was the result of these efforts. It mounts all the components required to fully utilize the Icarus and Daedalus sensors including analog to digital converters to convert pixel data and various system voltages to digital form for readout and analysis, DAC channels for remote configuration of critical bias voltages, static random-access memories to buffer pixel data, RS422 and Gigabit Ethernet communications for remote access, and an FPGA to tie these components together. This document describes the FPGA electrical interfaces in detail to allow the reader a greater understanding of the device, and to facilitate implementation of custom software to control and manage it. The Version 4.0 Board is a continuation of the Nano-second Gated CMOS hardware design that retains much of the functionality of the Version 1.0 Board while adding features including a DAC instead of digital potentiometers, as well as sensors for pressure and radiation. The Version 4.0 board is intended for applications requiring tight form-factor enclosures. It is composed of two stacking boards; one holds the FPGA and regulators to power the various components of the board while the other contains the mating connector to the sensor, image-readoff ADCs, the DAC, and other components.

42 ENGINEERING↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal mapping of microscopic strains and defects to reveal Li-dendrite-induced failure in all-solid-state batteries

Solid-state electrolytes (SSEs) are key to the success and reliability of all-solid-state lithium batteries, potentially enabling improvements in terms of safety and energy density over state-of-the-art lithium-ion batteries. However, there are several critical challenges to their implementation, including the interfacial instability stemming from the dynamic interaction of as-formed dendritic lithium during cycling. Here, we emphasize the importance of studying the spatial distribution and temporal evolution of strains and defects in crystalline solid-state electrolytes at the micro-scale, and how this affects dendrite growth. A proof-of-principle study is demonstrated using the synchrotron radiation based micro Laue X-ray diffraction method, and a custom-developed in-situ cycling device. Defects and residual strains are mapped, and the evolution of intragranular misorientation is observed. The feasibility of using this technique is discussed, and recommendations for micro-strain engineering to address the Li/SSEs interfacial issues are given. Additionally, work directions are pointed out with the consideration of combining multi-techniques for “poly-therapy”.

36 MATERIALS SCIENCE↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

Simple, passive design for large optical trap arrays for single atoms

We present an approach for trapping cold atoms in a two-dimensional (2D) optical trap array generated with a 4f filtering scheme and custom transmission mask without any active device. The approach can be used to generate arrays of bright or dark traps, or both simultaneously with a single wavelength for forming two-species traps. We demonstrate the design by creating a 2D array of 1225 dark trap sites, where single Cs atoms are loaded into regions of near-zero intensity in an approximately Gaussian profile trap. Moreover, we demonstrate a simple solution to the problem of out-of-focus trapped atoms, which occurs due to the Talbot effect in periodic optical lattices. Using a high power yet low cost spectrally and spatially broadband laser, out-of-focus interference is mitigated, leading to near perfect removal of Talbot plane traps.

74 ATOMIC AND MOLECULAR PHYSICS↗

CRADA Number NFE-20-08283 with Actinic LLC (CRADA Final Report)

Significant advances have been made in the additive manufacturing (AM) of thermoplastics and optically cured thermosets; however, AM of thermally cured thermosets has lagged. Materials belonging to this class of thermosets, such as silicone rubbers and polyurethanes, are not well represented in the AM space despite their widespread use in medical, defense, and other fields. Ideally, a solution would enable AM of current commercially viable thermally cured thermosets with a speed that is comparable to those already realized for thermoplastics and optically cured thermosets. Realizing this goal will provide several benefits, including: 1. Make thermally cured thermoset designs impossible via casting. 2. Iteration of part designs without investment in new molds. 3. Devices and personal protection equipment, custom-fit to the end-user. 4. Ability to print multifunctional composite materials. 5. Rapid production ability for DoD personnel deployed at forward locations. 6. Simplify supply chains and replace multiple parts with a single raw material. These benefits motivate the development of a commercially viable 3D printer for thermally cured thermosets, based on the technique of photothermal curing. This project further developed a printer capable of printing composites containing commercially available thermally cured polydimethylsiloxane (PDMS), directly yielding cured parts such as boxes, walls, and free-standing overhangs.

36 MATERIALS SCIENCE↗

Identification and Reduction of Interactional Noise of a Quadcopter in Hover and Forward Flight Conditions

Advanced Air Mobility is a vision for a safe, accessible, and sustainable aviation system to transport people and cargo between places not served by traditional aviation. With this emerging transportation industry, there is motivation to characterize the noise of vehicles to determine their potential impacts on the community. An experimental testing campaign was conducted on a representative model of a small unmanned aircraft system in the NASA Langley Low Speed Aeroacoustic Wind Tunnel as a continuation of a previous testing campaign. The goals of the current test are to identify sources of interactional noise as well as to test custom-designed rotors and noise reduction devices. The tested noise reduction methods involve increasing the vertical distances between the rotors and the vehicle airframe as well as between the forward and aft rotor disk planes. These methods are intended to reduce rotor-airframe interaction noise in hover and fore-aft rotor wake ingestion noise in forward flight. A phased microphone array is also utilized to identify the locations of prominent noise generation for the different vehicle configurations in forward flight. Elevation of the rotors from the vehicle airframe yielded nearly 8 dBA overall noise reduction in forward flight, while yielding up to 4 dB reduction in overall tonal levels for one of the rotors in hover.

Nikolas S Zawodny↗

Custom Integration of Multiple Medical Functionalities

INTRODUCTION: Previous spaceflight experience and results from probabilistic risk assessment of spaceflight medical risk have highlighted the need for vital sign measurements, medical scopes, and clinical imaging tools for managing medical conditions during spaceflight. The Human Research Program’s Exploration Medical Capability (ExMC) Element and the Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) have performed ground-based evaluations of two Commercial-off-the-Shelf (COTS) Multi-functional Integrated Medical (MIM) devices, which integrate various medical capabilities together in one device. The key findings from these evaluations are presented in a complementary presentation, leaving this presentation to focus on forward recommendations for customized integration of multiple medical functionalities. KEY COMPONENTS: The key features of a custom integration of multiple medical functionalities includes devices and capabilities that optimally reduce medical risk. The COTS MIM devices incorporated functionality for best supporting Earth-based, emergency, pre-hospital care. Our custom integration will use probabilistic risk assessment tools, such as the Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT), to determine the optimal functionality to include based on medical risk minimization. An additional feature of custom integration includes the ability to adapt to different requirements within different vehicles and/or missions. The COTS MIM devices store data in patient specific records, however, the format of the records is not modifiable, and data are not easily transferred from the MIM device to a central data architecture outside of the manufacturer’s established system. Our concept for custom integration will use devices that have an open application programming interface, which can easily connect to independent data architectures and third-party visualization software. The ultrasound capabilities included within the COTS MIM devices did not satisfy many of the Artemis Research and Operations Working Group’s ultrasound functional needs, and therefore, incorporation of higher quality ultrasound capabilities within a customized integration will be beneficial. The COTS MIM devices included minimal procedural guidance and clinical decision support tools. Supplemental tools of this type would need to be supplied along with the COTS MIM devices if they were to be used operationally, so another advantage of customization is the ability to integrate these support tools along with the medical functionality, for a more streamlined user experience. CONCLUSION: Investigation of a customized integration of medical functionality provides a method for further understanding the needs of a long-term exploration spaceflight medical system. The crew members of these exploration missions will need to operate more and more independently from Earth-based ground support. Therefore, having an optimized, streamlined medical system, which contains the functionality and supporting information needed, while remaining within mission and vehicle constraints, will help to maintain crew health and performance, which is necessary for achieving high levels of mission success.

B E Lewandowski↗

Quantum state preparation by adiabatic evolution with custom gates

Quantum state preparation by adiabatic evolution is currently rendered ineffective by the long implementation times of the underlying quantum circuits, comparable to the decoherence time of present and near-term quantum devices. These implementation times can be significantly reduced by realizing these circuits with custom gates. Using classical computing, we model the output of a realistic two-qubit processor implementing the adiabatic evolution of a two-spin system by means of custom gates. This modeled output is then compared with the results of quantum simulations solving the same problem on IBM Quantum (IBMQ) systems. Additionally, when used to emulate the behavior of the IBMQ quantum circuit, our realistic model yields state fidelities ranging from 65% to 85%, similar to the actual performance of a diverse set of IBMQ devices. When we reduced the implementation time by using custom gates, however, the loss of fidelity was reduced by at least a factor of 4, allowing us to accurately extract the energy of the target state. This improvement is enough to render adiabatic evolution useful for quantum state preparation for small systems or as a preconditioner for other state preparation methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Control optimization for parametric Hamiltonians by pulse reconstruction

Optimal control techniques provide a means to tailor the control pulses required to generate customized quantum gates, which helps to improve the resilience of quantum simulations to gate errors and device noise. However, the significant amount of (classical) computation required to generate customized gates can quickly undermine the effectiveness of this approach, especially when pulse optimization needs to be iterated. We propose a method to reduce the computational time required to generate the control pulse for a Hamiltonian that is parametrically dependent on a time-varying quantity. We use simple interpolation schemes to accurately reconstruct the control pulses from a set of pulses obtained in advance for a discrete set of predetermined parameter values. We obtain a reconstruction with very high fidelity and a significant reduction in computational effort. We report the results of the application of the proposed method to device-level quantum simulations of the unitary (real) time evolution of two interacting neutrons based on superconducting qubits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Harvesting Wave Energy to Power Acoustic Transmitters Using Triboelectric Nanogenerator

Wave energy has the largest reserves and widest distribution among blue energy sources. However, the conversion and utilization of ocean wave energy are challenging. In this work, we developed a contact-separation mode triboelectric nanogenerator (TENG) with a simple structure for harvesting wave energy and powering marine sensors and transmitters and performed detailed electrical characterization under controlled laboratory conditions. A prototype power management circuit (PMC) was implemented to improve the output performance of the TENG. The output from the PMC could charge up a storage capacitor for powering sensors and electronics. Eventually, the TENG was integrated within a water-proof enclosure and tested using a custom-built wave simulator to evaluate the device performance in a more representative scenario. The device sustainably powered up an array of 27 LEDs and was able to charge up a capacitor up to 1.8 V for driving an acoustic transmitter. The results demonstrate that TENG technology shows great promise in harvesting low-frequency ocean wave energy.

Yang, Yang↗

Distribution Network Capacity Market Design: Marginal Distribution Capacity Pricing Mechanism for Efficient Investment and Cost Allocation

As electricity markets begin to shift from reliance on large, centralized power plants and towards distributed energy resources (DERs), there is a growing acknowledgement that more efficient planning, operations, and oversight is needed in the distribution system. This paper addresses one step in that direction by proposing an auction mechanism that uses a detailed distribution system planning model that allocates permits to end-used customers who request capacity to install new devices at their location and network upgrade contracts to utilities or 3rd-party companies who offer to upgrade system components. The resulting plan maximizes market surplus, that is, maximizes the total benefit to consumers minus the cost of network upgrades. We apply a marginal pricing scheme to the auction’s results such that the cost of each permits or contracts is differentiated by time and location, based on the Lagrangian multipliers of binding network constraints. These prices are shown to be no greater than the bid price of any awarded contract and no less than the offered cost of any awarded upgrade contract. Furthermore, the nonlinearity of power flows in the planning model result in an additional surplus that would be collected by the entity that hosts the auction, which could then be refunded to market participants or used to cover overhead costs of running the market. We provide four example auction results in a simple three-node distribution feeder to demonstrate the properties of the design. Results suggest that larger or more realistic case studies could be a promising next step.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Solar Thermophotovoltaic Electric Generator for Remote Power Applications

We have successfully demonstrated that a solar thermophotovoltaic (TPV) system with a SiC graybody emitter and the monolithic interconnected module device technology can be realized. A custom-designed solar cavity was made to house the SiC emitter and the Monolithic Integrated Module (MIM) strings for testing in a Stirling dish solar concentrator. Five 1x1-cm MIMs, with a bandgap of 0.74 eV, were mounted on a specially designed water-cooled heatsink and were electrically connected in series to form a string. Two such strings were fabricated and tested, as well as high-performance 2x2-cm MIMs with a bandgap of 0.74 eV. Very high output power density values between 0.82 and 0.90 W/ square cm were observed for an average emitter temperature of 1501 K.

Fatemi, Navid S.↗

A Solar Thermophotovoltaic Electric Generator for Remote Power Applications

We have successfully demonstrated that a solar thermophotovoltaic (TPV) system with a SiC graybody emitter and the monolithic interconnected module device technology can be realized. A custom-designed solar cavity was made to house the SiC emitter and the MIM strings for testing in a Stirling dish solar concentrator. Five 1x1-cm MIMs, with a bandgap of 0.74 eV,were mounted on a specially designed water-cooled heatsink and were electrically connected in series to form a string. Two such strings were fabricated and tested, as well as high-performance 2x2-cm MIMs with a bandgap of 0.74 eV. Very high output power density values between 0.82 and 0.90 W/sq cm were observed for an average emitter temperature of 1501 K.

Fatemi, Navid S.↗

Conformance Testing: Measurement Decision Rules

The goal of a Quality Management System (QMS) as specified in ISO 9001 and AS9100 is to provide assurance to the customer that end products meet specifications. Measuring devices, often called measuring and test equipment (MTE), are used to provide the evidence of product conformity to specified requirements. Unfortunately, processes that employ MTE can become a weak link to the overall QMS if proper attention is not given to the measurement process design, capability, and implementation. Documented "decision rules" establish the requirements to ensure measurement processes provide the measurement data that supports the needs of the QMS. Measurement data are used to make the decisions that impact all areas of technology. Whether measurements support research, design, production, or maintenance, ensuring the data supports the decision is crucial. Measurement data quality can be critical to the resulting consequences of measurement-based decisions. Historically, most industries required simplistic, one-size-fits-all decision rules for measurements. One-size-fits-all rules in some cases are not rigorous enough to provide adequate measurement results, while in other cases are overly conservative and too costly to implement. Ideally, decision rules should be rigorous enough to match the criticality of the parameter being measured, while being flexible enough to be cost effective. The goal of a decision rule is to ensure that measurement processes provide data with a sufficient level of quality to support the decisions being made - no more, no less. This paper discusses the basic concepts of providing measurement-based evidence that end products meet specifications. Although relevant to all measurement-based conformance tests, the target audience is the MTE end-user, which is anyone using MTE other than calibration service providers. Topics include measurement fundamentals, the associated decision risks, verifying conformance to specifications, and basic measurement decisions rules.

Mimbs, Scott M.↗

PCB-Based Break-Out Box

Break-out boxes (BOBs) are necessary for all electrical integration/cable checkouts and troubleshooting. Because the price of a BOB is high, and no work can be done without one, often the procedure stops, simply waiting for a BOB. A less expensive BOB would take less time in the integration, testing, and troubleshooting process. The PCB-based BOB works and looks the same as a standard JPL BOB, called Gold Boxes. The only differences between the old BOB and the new PCB-based BOB is that the new one has 80 percent of its circuitry in a printed circuit board. This process reduces the time for fabrication, thus making the BOBs less expensive. Moreover, because of its unique design, the new BOBs can be easily assembled and fixed. About 80 percent of the new PCB-based BOB is in a $22 (at the time of this reporting) custom-designed, yet commercially available PCB. This device has been used successfully to verify that BOB cables were properly made. Also, upon completion, the BOB was beeped out via a multimeter to ensure that all sockets on the connectors were properly connected to the respective banana jack. When compared to the Gold Box BOBs, the new BOB has many advantages. It is much more cost efficient, it delivers equal usability at substantially lower cost of the BOB, and the Gold Box is much heavier when compared to the new BOB. The new BOB is also a bit longer and much more versatile in that connectors are easily changeable and if a banana jack is broken, it can be replaced instead of throwing away an entire BOB.

Lee, Jason H.↗

Experimental Durability Testing of 4H SiC JFET Integrated Circuit Technology at 727 C

We have reported SiC integrated circuits (IC's) with two levels of metal interconnect that have demonstrated prolonged operation for thousands of hours at their intended peak ambient operational temperature of 500 C [1, 2]. However, it is recognized that testing of semiconductor microelectronics at temperatures above their designed operating envelope is vital to qualification. Towards this end, we previously reported operation of a 4H-SiC JFET IC ring oscillator on an initial fast thermal ramp test through 727 C [3]. However, this thermal ramp was not ended until a peak temperature of 880 C (well beyond failure) was attained. Further experiments are necessary to better understand failure mechanisms and upper temperature limit of this extreme-temperature capable 4H-SiC IC technology. Here we report on additional experimental testing of custom-packaged 4H-SiC JFET IC devices at temperatures above 500 C. In one test, the temperature was ramped and then held at 727 C, and the devices were periodically measured until electrical failure was observed. A 4H-SiC JFET on this chip electrically functioned with little change for around 25 hours at 727 C before rapid increases in device resistance caused failure. In a second test, devices from our next generation 4H-SiC JFET ICs were ramped up and then held at 700 C (which is below the maximum deposition temperature of the dielectrics). Three ring oscillators functioned for 8 hours at this temperature before degradation. In a third experiment, an alternative die attach of gold paste and package lid was used, and logic circuit operation was demonstrated for 143.5 hours at 700 C.

JFET↗

Experimental Durability Testing of 4H SiC JFET Integrated Circuit Technology at 727 Degrees Centigrade

We have reported SiC integrated circuits (ICs) with two levels of metal interconnect that have demonstrated prolonged operation for thousands of hours at their intended peak ambient operational temperature of 500 degrees Centigrade. However, it is recognized that testing of semiconductor microelectronics at temperatures above their designed operating envelope is vital to qualification. Towards this end, we previously reported operation of a 4H-SiC JFET IC ring oscillator on an initial fast thermal ramp test through 727 degrees Centigrade. However, this thermal ramp was not ended until a peak temperature of 880 degrees Centigrade (well beyond failure) was attained. Further experiments are necessary to better understand failure mechanisms and upper temperature limit of this extreme-temperature capable 4H-SiC IC technology.Here we report on additional experimental testing of custom-packaged 4H-SiC JFET IC devices at temperatures above 500 degrees Centigrade. In one test, the temperature was ramped and then held at 727 degrees Centigrade, and the devices were periodically measured until electrical failure was observed. A 4H-SiC JFET on this chip electrically functioned with little change for around 25 hours at 727 degrees Centigrade before rapid increases in device resistance caused failure. In a second test, devices from our next generation 4H-SiC JFET ICs were ramped up and then held at 700 degrees Centigrade (which is below the maximum deposition temperature of the dielectrics). Three ring oscillators functioned for 8 hours at this temperature before degradation. In a third experiment, an alternative die attach of gold paste and package lid was used, and logic circuit operation was demonstrated for 143.5 hours at 700 degrees Centigrade.

Silicon Carbide↗